Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-36731354

RESUMO

Pyridoxal-5'-phosphate (PLP), the active form of vitamin B6, is required for numerous enzymatic reactions. Vitamin B6 deficiency or exceptionally high levels of PLP have negative implications, making measurements of PLP imperative for diagnoses and monitoring in many clinical scenarios. Traditional assays are enzymatic, ELISA based, or employ HPLC with various detection modalities; all of these are prone to interferences and crossreactivity with other compounds. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been increasingly used to overcome these issues, but the high polarity of PLP raises chromatographic challenges. Using ion pairing reagents in the mobile phases is a possible solution, but these reagents often have deleterious effects on instrumentation. An alternative strategy is the addition of an ion pairing reagent after extraction, but prior to injection. To prove this, we used 1-octanesulfonic acid (OSA) without changing the LC method or column. With this technique, we observed a 2-4 fold increase in signal-to-noise ratio. Intraday and interday precision of replicate measurements also improved drastically compared to analyses without OSA, while also yielding a dramatic improvement in column life compared to our previous approach and to this point no deleterious effects on instrument hardware commonly associated with traditional ion pairing reagent techniques have been observed.


Assuntos
Cromatografia Líquida , Fosfato de Piridoxal , Espectrometria de Massas em Tandem , Cromatografia Líquida/métodos , Fosfatos , Fosfato de Piridoxal/análise , Espectrometria de Massas em Tandem/métodos
2.
Steroids ; 99(Pt A): 39-44, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25159104

RESUMO

Estradiol quantitation is useful in the clinical assessment of diseases like hypogonadism, hirsutism, polycystic ovary syndrome (PCOS), amenorrhea, ovarian tumors and for monitoring response in women receiving aromatase inhibitor therapy. Physiologically relevant serum estradiol concentration in women can span across four orders of magnitude. For example, in women undergoing ovulation induction serum estradiol concentration can range between 250-2000 pg/mL whereas aromatase inhibitor therapy can decrease serum estradiol concentration to <5 pg/mL. While high-through-put automated un-extracted (direct) immunoassays accommodate the growing clinical need for estradiol quantitation, are amenable to implementation by most hospital clinical laboratories, they display a significant loss of specificity and accuracy at low concentrations. Most clinical scenarios (example: estradiol monitoring in fertility treatments) place a modest demand on accuracy and precision of the assay in use but accurate quantitation of estradiol in certain clinical scenarios (pediatric and male patients and for monitoring aromatase inhibitor therapy) can be challenging using currently available immunoassays since the direct immunoassays are prone to issues with sub-optimal accuracy and specificity due to cross reactivity with estradiol conjugates and metabolites. In this review we discuss the bases for the evolution of estradiol assays from extracted (indirect) radio-immunoassays to direct immunoassays to liquid-chromatography tandem mass spectrometry (LC-MS/MS) based assays, discuss technical factors relevant for development and optimization of a LC-MS/MS assay for estradiol and present the details and performance characteristics of an ultra-sensitive LC-MS/MS estradiol assay with a limit of quantitation of 0.2 pg/mL.


Assuntos
Cromatografia Líquida/métodos , Estradiol/análise , Imunoensaio/métodos , Espectrometria de Massas em Tandem/métodos , Estradiol/sangue , Estradiol/metabolismo , Feminino , Humanos , Radioimunoensaio , Sensibilidade e Especificidade
3.
Clin Gastroenterol Hepatol ; 11(10): 1270-1275.e1, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23639599

RESUMO

BACKGROUND & AIMS: There is an unclear relationship among bowel symptoms, excretion of unconjugated fecal bile acid (UBA), and colonic transit in irritable bowel syndrome (IBS). We measured total and main individual UBA in fecal samples of patients with IBS and assessed relationships among stool frequency or consistency, fecal UBA (total and individual), and colonic transit. METHODS: In this study 30 healthy volunteers (controls), 31 subjects with IBS with diarrhea (IBS-D), and 30 with IBS with constipation (IBS-C) were placed on 4-day diets containing 100 g fat; we measured stool characteristics, total fecal UBA and fat levels, and overall colonic transit. We assessed univariate associations of total and individual levels of fecal UBA with phenotype (controls, IBS-D, IBS-C) by using the Kruskal-Wallis test; associations between end points were assessed by using Spearman correlations. With response surface regression models, we assessed relationships between stool, colonic transit, and fecal total and secretory UBA. RESULTS: There was a significant association between total fecal UBA and phenotype (P = .029); the association was greater for IBS-D than IBS-C, compared with controls. Fecal levels of primary UBAs (cholic and chenodeoxycholic acids) were higher in subjects with IBS-D, compared with controls (both P < .01). Levels of fecal secretory UBAs (chenodeoxycholic acid, P = .019; deoxycholic acid, P = .025) were lower in subjects with IBS-C compared with controls, whereas levels of the nonsecretory UBA, lithocholic acid, were higher (P = .020). There were significant univariate associations between stool number and form and total fecal UBA (including percentages of lithocholic acid, chenodeoxycholic acid and cholic acid), fecal fat, and colonic transit at 24 and 48 hours after eating. In the regression models, the relative contribution of colonic transit was consistently greater and largely independent of the contribution of bile acids. CONCLUSIONS: Measurements of individual UBAs identify changes associated with stool characteristics in patients with IBS; these effects are independent of the effects of colonic transit.


Assuntos
Ácidos e Sais Biliares/análise , Fezes/química , Trânsito Gastrointestinal , Intestinos/fisiopatologia , Síndrome do Intestino Irritável/fisiopatologia , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
4.
Clin Chem ; 57(3): 431-40, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21245371

RESUMO

BACKGROUND: The limits of chromatographic speed and mechanical frontend capabilities have been reached for many high-volume liquid chromatography-tandem mass spectrometry (LC-MS/MS) tests, curtailing the maximal achievable sample throughput. To overcome these boundaries, we developed and validated a derivatization-based sample-multiplex LC-MS/MS assay for detection of 25-hydroxyvitamins D2 and D3 [25(OH)D2 and 25(OH)D3], which increased sample throughput 5-fold. METHODS: After separate derivatization with 1 of 5 different triazoline-diones (TADs), 5 calibrators, controls, or patient specimens were combined and injected together into an LC-MS/MS. On the basis of mass differences between TADs, the MS/MS quantified analyte and stable isotope internal standards for 25(OH)D2 and 25(OH)D3 for each respective multiplexed sample within the injection. Limits of detection and quantification, spiked recovery, linearity, imprecision, and patient results were determined and compared against our standard LC-MS/MS assay. RESULTS: TAD multiplexing increased throughput on an LC-quadruplexed LC-MS/MS system from 60 samples/h to 300 samples/h. Limits of detection and quantification were 4.9 nmol/L [2 µg/L, 25(OH)D2], 2.2 nmol/L [0.9 µg/L, 25(OH)D3], and 10 nmol/L [4 µg/L, 25(OH)D2], 5 nmol/L [2 µg/L, 25(OH)D3], respectively. The assay was linear to 250 nmol/L (100 µg/L). Interassay CVs across the reportable range were 3.7%-15.2%. Spiked recoveries were 94%-119%. The method comparison with the standard LC-MS/MS method showed slopes of 0.96 and 0.97 (Deming regression) for 25(OH)D2 (n=1733) and 25(OH)D3 (n=7614) (R2=0.96 and 0.97), respectively. CONCLUSIONS: Multiplexing samples by differential mass tagging in LC-MS/MS measurement of 25(OH)D2 and 25(OH)D3 allows for reliable quantification, with throughput increased over standard methods by the multiplexing factor.


Assuntos
25-Hidroxivitamina D 2/sangue , Calcifediol/sangue , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , 25-Hidroxivitamina D 2/química , Automação , Calcifediol/química , Calibragem , Cromatografia Líquida/instrumentação , Cromatografia Líquida/normas , Humanos , Estrutura Molecular , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/instrumentação , Espectrometria de Massas em Tandem/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...