Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
Radiol Med ; 121(11): 828-833, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27372707

RESUMO

Mammography is the gold standard for detection of early breast cancer and it is still the only diagnostic tool which shows reduction of the mortality from that. Despite that, there is a high chance of false negatives that can lead to diagnostic errors resulting in delays of treatment and worsening of prognosis. The aim of this study is to analyze the rate of false negative in mammography and assess the source of diagnostic errors. Two radiologists have retrospectively evaluated 500 mammograms performed between January 2008 and December 2011 in Breast Imaging Clinic. 250 patients (Group A) had been operated for breast cancer and 250 patients (Group B) were healthy woman submitted to mammography according to the guideline for early detection of breast cancer. In Group A, 138 patients (55.2 %) were true missed cancer, 61 had minimal sign (24.4 %) and 53 were false negative (FN) (20.4 %). The source of errors amongst the FN were in 42 % of cases due to perception, in 15 % to interpretation, in 10 % to subtle/unusual lesion characteristics, in 9 % error for satisfaction of search, in 7 % to inherent limitations of mammography, in 4 % to poor technique and 13 % for inadequate clinical management. The diagnostic errors in breast clinic services are not negligible. The largest number of FN results from perception errors, misinterpretation and inadequate clinical management. These can be related to factors such as inattention, fatigue or lack of experience. To reduce it, it is necessary to have a dedicated multidisciplinary staff and adequate equipment and workloads.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Erros de Diagnóstico/estatística & dados numéricos , Mamografia/estatística & dados numéricos , Reações Falso-Negativas , Feminino , Humanos , Programas de Rastreamento , Estudos Retrospectivos
2.
Eur J Radiol ; 81(8): 1834-8, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20138722

RESUMO

OBJECTIVES: To evaluate the presence of blood flow by colour Doppler ultrasonography (CDUS) in the wrist and finger joints of rheumatoid arthritis (RA) patients and healthy subjects and to define a cut-off value of CDUS resistive index (RI). METHODS: Forty-three patients with RA and 43 healthy controls were examined by CDUS. The wrists, second and third metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints were evaluated in each patient and healthy subject. Spectral Doppler analysis was performed in order to characterize the type of flow and a mean RI was measured to define a cut-off level. The area under receiver operating characteristic curve was used to evaluate the screening method's performance. RESULTS: Flow was detected in 219 of the 430 total joints (50.9%) of RA patients (111 in the wrists, 49 in the MCP and 30 in the PIP joints). Healthy subjects had a quantifiable flow in 45 of the 430 joints (10.5%) and, in particular, 39 (86.4%) in the wrist, 5 (11.14%) in the MCP and 1 (2.2%) in the PIP joints. The intra- and inter-reader agreements for the detection of Doppler signal were very good (kappa 0.82 and 0.89, respectively). Mean RI values were 0.72±0.06 in RA patients and 0.86±0.06 in healthy subjects (p<0.01). At cut-off point of RI<0.79 the sensitivity was 89.6% and the specificity was 78.8% (positive likelihood ratio 4.22). CONCLUSION: DUS is a useful tool for the detection of abnormal blood flow in inflammatory joints of RA patients.


Assuntos
Artrite Reumatoide/diagnóstico por imagem , Artrite Reumatoide/fisiopatologia , Articulações dos Dedos/diagnóstico por imagem , Articulações dos Dedos/fisiopatologia , Ultrassonografia Doppler em Cores/métodos , Velocidade do Fluxo Sanguíneo , Feminino , Articulações dos Dedos/irrigação sanguínea , Humanos , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Pathologica ; 103(5): 294-8, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22393685

RESUMO

Primary systemic therapy (PST) adds some practical problems to the pathologic examination of neoplastic breast tissue obtained from patients before and after chemotherapy. Pathologists, oncologists, breast surgeons, radiotherapists and radiologists in the Marche Region held a Consensus Meeting in Ancona on May 13, 2010, in which 15 statements dealing with neoadjuvant chemotherapy were approved by all participants. The first two statements are related to the pre-PST phase and concern the technical procedures and the histological report of the core biopsy. The other statements deal with similar issues of the post-PST surgical specimen.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/tratamento farmacológico , Mastectomia/métodos , Terapia Neoadjuvante/métodos , Relatório de Pesquisa/normas , Neoplasias da Mama/classificação , Feminino , Humanos , Metástase Linfática , Gradação de Tumores
4.
Radiol Med ; 115(4): 563-70, 2010 Jun.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-20082226

RESUMO

Computer-aided diagnosis (CAD) has been extensively reported to increase sensitivity by about 10% when added to a single reading while increasing recall rate by 12%, and its current use can be safely recommended in clinical practice. CAD has been suggested as a possible alternative to conventional double reading in screening. Uncontrolled comparison is consistent and suggests that CAD is comparable to double reading in incremental cancer detection rate (CAD +10.6%, double reading +9.1%) and possibly better in recall rate (CAD +12.5%, double reading +28.8%). However, controlled studies comparing single reading + CAD to conventional double reading are not consistent and on average suggest a lower cancer detection rate (-5.1%) and a lower recall rate (-9.8%) for CAD. Scientific evidence is not sufficient for a safe recommendation of single reading + CAD as a current alternative to conventional double reading.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Diagnóstico por Computador , Mamografia/métodos , Feminino , Humanos
5.
Radiol Med ; 113(8): 1085-95, 2008 Dec.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-18953635

RESUMO

The clinical use of breast magnetic resonance (MR) imaging is increasing, especially for applications requiring paramagnetic contrast-agent injection. This document presents a synthetic list of acceptable indications with potential advantages for women according to evidence from the literature and the expert opinion of the panel that developed this statement. We generally recommend that breast MR imaging be performed in centres with experience in conventional breast imaging [mammography and ultrasonography (US)] and needle-biopsy procedures (under stereotactic or US guidance) as well as in breast MR imaging and second-look US for findings not revealed by conventional imaging performed before MR imaging. In our opinion, there is no evidence in favour of breast MR imaging as a diagnostic tool to characterise equivocal findings at conventional imaging when needle-biopsy procedures can be performed, nor for the study of asymptomatic, non-high-risk women with negative conventional imaging. After a description of technical and methodological requirements, we define the indications and limitations of breast MR imaging for surveillance of high-risk women, local staging before surgery, evaluation of the effect of neoadjuvant chemotherapy, breast previously treated for carcinoma, carcinoma of unknown primary syndrome, nipple discharge and breast implants.


Assuntos
Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética , Feminino , Humanos
6.
Rheumatology (Oxford) ; 47(8): 1244-9, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18565986

RESUMO

OBJECTIVE: To compare ultrasonography (US) of salivary glands with contrast sialography and scintigraphy, in order to evaluate the diagnostic value of this method in primary SS (pSS). METHODS: The diagnostic value of parotid gland US was studied in 77 patients with pSS (male/female ratio 3/74; mean age 54 yrs) and in 79 with sicca symptoms but without SS. The two groups were matched for sex and age. Imaging findings of US were graded using an ultrasonographic score ranging from 0 to 16, which was obtained by the sum of the scores for each parotid and submandibular gland. The sialographic and scintigraphic patterns were classified in four different stages. The area under receiver operating characteristic curve (AUC-ROC) was employed to evaluate the screening method's performance. RESULTS: Of the 77 patients with pSS, 66 had abnormal US findings. Mean US score in pSS patients was 9.0 (range from 3 to 16). Subjects without confirmed pSS had the mean US score 3.9 (range from 0 to 9) (P < 0.0001). Results of sialography showed that 59 pSS patients had abnormal findings at Stage 1 (n = 4), Stage 2 (n = 8), Stage 3 (n = 33) or Stage 4 (n = 14), and 58 patients had abnormal scintigraphic findings at Stage 1 (n = 11), Stage 2 (n = 18), Stage 3 (n = 25) or Stage 4 (n = 4). Through ROC curves US arose as the best performer (AUC = 0.863 +/- 0.030), followed by sialography (AUC = 0.804 +/- 0.035) and by salivary gland scintigraphy (AUC = 0.783 +/- 0.037). The difference between AUC-ROC curve of salivary gland US and scintigraphy was significant (P = 0.034). Setting the cut-off score >6 US resulted in the best ratio of sensitivity (75.3%) to specificity (83.5%), with a likelihood ratio of 4.58. If a threshold >8.0 was applied the test gained specificity, at the cost of a serious loss of sensitivity (sensitivity 54.5%, specificity 97.5%, likelihood ratio 21.5). CONCLUSIONS: Salivary gland US is a useful method in visualizing glandular structural changes in patients suspected of having pSS and it may represent a good option as a first-line imaging tool in the diagnostics of the disease.


Assuntos
Glândula Parótida/diagnóstico por imagem , Síndrome de Sjogren/diagnóstico por imagem , Glândula Submandibular/diagnóstico por imagem , Adulto , Idoso , Meios de Contraste , Métodos Epidemiológicos , Feminino , Humanos , Iopamidol , Masculino , Pessoa de Meia-Idade , Cintilografia , Sialografia/métodos , Ultrassonografia
7.
Radiol Med ; 113(3): 439-51, 2008 Apr.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-18414812

RESUMO

PURPOSE: Our purpose was to compare mammography and dynamic contrast-enhanced magnetic resonance imaging (MRI) in the detection of ductal carcinoma in situ (DCIS). MATERIALS AND METHODS: Ninety patients (aged 58.6+/-16.1 years) who were candidates for unilateral (n=81) or bilateral (n=9) mastectomy underwent mammography and dynamic contrast-enhanced breast MRI using a coronal three-dimensional gradient-echo sequence with slice thickness < or =3 mm before and after intravenous injection of gadoteridol (0.1 mmol/kg). Mammographic and MR images were evaluated by two offsite readers working in consensus. Pathological examination performed on 5-mm sections covering the whole breast was used as a reference standard. RESULTS: Out of 99 breasts, pathology revealed 26 DCIS in 14 breasts of 14 patients, aged 52.0 +/- 9.6 years. Lesion diameter at pathology was <5 mm (n=4); > or =5 and <10 mm (n=7); > or =10 and <20 mm (n=3); > or =20 mm (n=2); not assessed (n=10). Sensitivity was 35% (9/26) for mammography and 38% (10/26) for MRI (not significant difference, McNemar test). Both mammography and MRI provided a true positive result in seven cases (four of them measured at pathology, with a diameter of 20.0+/-12.9 mm; median 20 mm) and a false negative result in 14 cases (10 of them measured at pathology, with a diameter of 4.2+/-1.9 mm; median 4.6 mm) (p=0.024, Mann-Whitney U test). Only 46% (12/26) of DCIS were detected at mammography and/or MRI; the remaining 54% (14/26) were diagnosed only at pathological examination. CONCLUSIONS: When the whole breast is used as the histopathological reference standard, both mammography and MRI show low sensitivity for DCIS.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/patologia , Imageamento por Ressonância Magnética , Mamografia , Adulto , Meios de Contraste , Feminino , Gadolínio , Compostos Heterocíclicos , Humanos , Itália , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Pessoa de Meia-Idade , Compostos Organometálicos , Estudos Prospectivos , Sensibilidade e Especificidade
8.
Clin Exp Rheumatol ; 25(1): 67-74, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17417993

RESUMO

OBJECTIVE: The main objective of the present study was to test the interobserver reliability, truth, discrimination and feasibility of two scoring methods available in ankylosing spondylitis (AS) over a follow-up period of 3 years. METHODS: Two blinded trained observers scored 95 AS radiographs from a cohort of AS patients. Each radiograph was scored by two scoring methods, the modified Stoke Ankylosing Spondylitis Spine Score (mSASSS), and the Bath Ankylosing Spondylitis Radiology Index--spine (BASRI-spine). Interobserver agreement was analyzed by intraclass correlation coefficients (ICC). The construct validity was assessed by examining the correlation of the scoring methods with measures of spinal mobility (Bath Ankylosing Spondylitis Metronomy Index--BASMI), functional limitation (Bath Ankylosing Spondylitis Functional Index--BASFI) and disease duration. Bland and Altman's 95% limits of agreement method and effect size (ES) analysis were used to estimate the smallest detectable difference (SDD) of radiological progression and responsiveness. RESULTS: The BASRI-spine reached intra- and interobserver ICC of 0.755 and 0.831, respectively. The mSASSS scores were more reliable, with ICC of 0.874 and 0.941, respectively. Both scoring systems correlated significantly with BASMI (p = 0.01), while only the mSASSS showed a significant correlation (p = 0.02) with BASFI. With regards to sensitivity to change, it was found that mSASSS classified the highest percentage of patients with more changes than the BASRI-spine (mSASSS: 35.8% vs. BASRI-spine: 15.8%). The ES analysis also suggested that the mSASSS was more responsive than BASRI-spine. Concerning feasibility, the BASRI-spine takes less time for scoring. CONCLUSION: We have shown that the mSASSS offers advantages in measurement properties and is the most appropriate method by which to assess progression of structural damage in AS.


Assuntos
Vértebras Cervicais/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Articulação Sacroilíaca/diagnóstico por imagem , Índice de Gravidade de Doença , Espondilite Anquilosante/classificação , Espondilite Anquilosante/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Radiografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Reumatismo ; 59(1): 38-49, 2007.
Artigo em Italiano | MEDLINE | ID: mdl-17435841

RESUMO

BACKGROUND: Patients with rheumatoid arthritis (RA) have a reduced life expectancy and high cardiovascular morbidity and mortality as compared to the general population. A number of possible factors for the atherogenesis in this disease have been described, such as homocysteine, altered serum levels of selected lipoproteins and treatment. Recent findings indicate that the systemic inflammation may contribute to the development of atherosclerosis and confer an additional risk for cardiovascular death among patients with RA. The aim of our study was to evaluate the ability of high resolution Bmode ultrasound and color Doppler to assess the existence of subclinical atherosclerosis in RA patients, measuring the intima-media thickness (IMT) and resistance index of the common carotid arteries. METHODS: Carotid IMT and carotid plaque were measured using high-resolution B-mode ultrasound in 40 patients with RA and 40 age- and sex-matched healthy persons. We used color Doppler ultrasound to assess vascular damage of the common carotid arteries and the resistance index (RI) was determined by analysis of the spectral waveforms. Serum total cholesterol, triglycerides-density lipoprotein cholesterol, low-density lipoprotein cholesterol, rheumatoid factor, body mass index (BMI), visual analogue scale (VAS) were determined in patients and controls. C-reactive protein (CRP) and the DAS28 were used to measure systemic inflammation. RESULTS: Common carotid IMT were significantly higher (p=0.0009) in RA patients (0.83 +/- 0.23) compared with controls (0.66 +/- 0.22). In RA patients common carotid IMT was significantly correlated with serum total cholesterol (p=0.0008), low-density lipoprotein cholesterol (p=0.006), triglycerides (p=0.042), age (p=0.031) and disease duration (p=0.019). No significant correlation was found with clinical and laboratory parameters reflecting disease activity. The prevalence of plaques was higher in RA patients compared with controls (25% vs 12.5%). There was no significant difference in color Doppler findings, and in particular in RI, between patients and controls. CONCLUSIONS: Our results confirm an accelerated atherosclerosis, as shown by increased common carotid IMT, in patients with RA compared with controls and it is related mainly to lipid levels. High-resolution B-mode ultrasound may be considered a promising, sensitive and non invasive tool for assessing the existence of subclinical atherosclerosis in RA patients.


Assuntos
Artrite Reumatoide/diagnóstico por imagem , Aterosclerose/diagnóstico por imagem , Artéria Carótida Primitiva/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Túnica Íntima/diagnóstico por imagem , Túnica Média/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Adulto , Idoso , Idoso de 80 Anos ou mais , Artrite Reumatoide/sangue , Artrite Reumatoide/complicações , Aterosclerose/sangue , Aterosclerose/complicações , Biomarcadores/sangue , Índice de Massa Corporal , Proteína C-Reativa/análise , Artéria Carótida Primitiva/patologia , Estenose das Carótidas/patologia , Estudos de Casos e Controles , Colesterol/sangue , Feminino , Humanos , Lipoproteínas HDL/sangue , Lipoproteínas LDL/sangue , Masculino , Pessoa de Meia-Idade , Fator Reumatoide/sangue , Fatores de Risco , Índice de Gravidade de Doença , Triglicerídeos/sangue , Túnica Íntima/patologia , Túnica Média/patologia , Resistência Vascular
10.
Reumatismo ; 58(2): 138-56, 2006.
Artigo em Italiano | MEDLINE | ID: mdl-16829993

RESUMO

The algorithm for imaging of the salivary glands depends on the clinical scenario with which the patient presents to the clinician. Ultrasound has been increasingly used in recent years and thanks to high performance, easy to use apparatus, it can now be used for exploration of the salivary glands. This non invasive, painless and relatively inexpensive examination provides rapid visualisation of the salivary glands and is a useful adjunct to computed tomography and magnetic risonance imaging examination, particularly in tumour pathology. In recent years, publications have highlighted the potential uselfulness of salivary gland ultrasonography as a simple and non-invasive adjunctive test for the detection of gland involvement in Sjögren's syndrome (SS). SS is a chronic inflammatory disease of the salivary glands characterised by focal lymphocytic infiltrates that cause progressive destruction of the acinar structures. The findings of a previous study lead us to believe, in agreement with other examiners, that semiquantitative assessment of ultrasonographic images of the salivary glands is a sensitive and very useful means of evaluating salivary involvement in SS. Color Doppler sonography is a recently introduced method which makes it possible to evaluate intra- and perilesional vascularization and to perform a hemodynamic study of the area being explored. The color Doppler sonography can provide a useful adjunct to conventional ultrasound, increasing diagnostic accuracy in submandibular- parotid masses and to analyze physiologic changes that occur during salivary stimulation in normal subjects and the flow alterations that occur in diseased glands of SS patients. This article reviews the normal ultrasound anatomy of the salivary glands along with lithiasic, inflammatory, tumoral, and autoimmune disease such as SS.


Assuntos
Doenças das Glândulas Salivares/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Humanos , Neoplasias das Glândulas Salivares/diagnóstico por imagem , Sialadenite/diagnóstico por imagem , Síndrome de Sjogren/diagnóstico por imagem
11.
Lung Cancer ; 49(3): 371-6, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15951051

RESUMO

We hypothesised that anemia could represent an important prognostic factor and perioperative blood transfusions do not reduce the risk of relapse. In order to explore this topic, we assessed the correlation of preoperative anemia and blood transfusions with survival in patients with resected non-small cell lung cancer (NSCLC). Patients who underwent radical surgery for NSCLC at the Department of Thoracic Surgery of Università Politecnica delle Marche from January 1996 through December 2001, were included in our study. Four hundred and thirty-nine patients were eligible for our analysis. Survival appeared worse in patients with haemoglobin (Hb) < or =10 g/dl versus Hb >10 g/dl (p=0.012). Stratifying patients in three groups on their Hb level (group 1: Hb < or =10 g/dl; group 2: Hb=10-12 g/dl; group 3: Hb > or =12 g/dl), we observed a worse prognosis in patients with lower Hb levels, too (p=0.0325) and also in the transfused population (p=0.046). At multivariate analysis, only the age of patients, pathological stage and Hb levels resulted indicators of prognosis. Our results suggested that anemia could represent an important prognostic factor in resected NSCLC and correction of anemia in the perioperative setting does not reduce the risk of relapse.


Assuntos
Transfusão de Sangue , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/cirurgia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Modelos de Riscos Proporcionais , Recidiva , Fatores Sexuais , Fatores de Tempo , Resultado do Tratamento
12.
Clin Rheumatol ; 23(4): 285-90, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15293087

RESUMO

The aim of this study was to evaluate the ability of power Doppler sonography (PDS) with ultrasound contrast agent to assess the synovial perfusion changes induced by intra-articular steroid injection therapy in the knee joints of patients with rheumatoid arthritis (RA). Eighteen RA patients (16 women, 2 men) with a history and signs of active knee synovitis were studied. Tenderness was evaluated using Thompson's modified index of synovitis activity. All patients underwent joint aspiration followed by intra-articular injection of 40 mg of triamcinolone hexacetonide. Gray-scale ultrasonography and PDS with an intravenous ultrasound contrast agent (Levovist) examinations were carried out before and 3 weeks after the intra-articular steroid injection. The calculation of the time--intensity curves provided a quantitative estimation of the synovial perfusion. The median values of the index of synovitis activity decreased significantly from 7.0 (95% confidence interval (CI) 6.0-8.0) to 3.0 (95% CI 2.0-4.0) ( p<0.01) 3 weeks after the intra-articular steroid injection. All patients showed a reduction of PDS signal after intra-articular steroid therapy and the baseline and follow up median values of the area underlying time-intensity curves were 7.48 (95% CI 5.79-8.73) and 2.45 (95% CI 1.92-3.61), respectively. The comparison between baseline and follow-up median values of the area under the curves showed a statistically significant reduction of PDS findings ( p<0.01). At follow-up examinations the changes in the index score of the synovitis activity were significantly correlated to the changes in the values of the area underlying time-intensity curves ( r=0.785; p<0.01). A significant correlation was also observed between baseline values of the area underlying time-intensity curves and C-reactive protein (CRP) ( r=0.548; p=0.023). In conclusion, PDS with an intravenous ultrasound contrast agent has been shown to be able to detect changes in synovial perfusion after intra-articular steroid injection and may be an additional useful method in the evaluation of synovial inflammation and in the assessment of the therapeutic response.


Assuntos
Artrite Reumatoide/diagnóstico por imagem , Meios de Contraste/farmacologia , Articulação do Joelho/diagnóstico por imagem , Polissacarídeos/farmacologia , Membrana Sinovial/diagnóstico por imagem , Sinovite/diagnóstico por imagem , Triancinolona Acetonida/análogos & derivados , Adulto , Idoso , Anti-Inflamatórios/uso terapêutico , Antirreumáticos/administração & dosagem , Antirreumáticos/uso terapêutico , Artrite Reumatoide/complicações , Artrite Reumatoide/tratamento farmacológico , Feminino , Humanos , Aumento da Imagem/métodos , Injeções Intra-Articulares , Articulação do Joelho/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Membrana Sinovial/irrigação sanguínea , Sinovite/tratamento farmacológico , Sinovite/etiologia , Resultado do Tratamento , Triancinolona Acetonida/uso terapêutico , Ultrassonografia Doppler
13.
Eur J Radiol ; 51(1): 27-33, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15186881

RESUMO

Liver cirrhosis is associated with haemodynamic changes. Using Levovist, we measured and compared Doppler signal arrival and peak enhancement times in the hepatic vein of patients with cirrhosis (n= 12) or chronic liver disease (n= 16) and in 12 healthy subjects. There were six patients with Child stage A, one patient with B, and five patients with C. The signal was recorded starting 20 s before contrast infusion until 2 h 20 min after its end. A software of the ultrasound (US) machine automatically sampled time-intensity values. Arrival times were significantly shorter (P < 0.001) in cirrhotic than non-cirrhotic (chronic liver disease + controls) and in patients with Child stage C compared with A. Differences in peak enhancement were weakly significant between cirrhotic and chronic patients (P < 0.04) and highly significant between the former and controls (P < 0.001), whereas differences between Child stages C and A were not significant (P > 0.05). Finally, cirrhotic patients had arrival times consistently shorter than 17 s. Automatic time-intensity curve analysis made measurements objective and conceptual error systematic, thus identifiable. Analysis of the passage of Levovist at the hepatic vein can thus become a non-invasive, well-tolerated and cost-effective diagnostic and monitoring tool in a larger number of patients with liver disease.


Assuntos
Hemodinâmica , Cirrose Hepática/diagnóstico por imagem , Análise de Variância , Estudos de Casos e Controles , Doença Crônica , Meios de Contraste , Feminino , Veias Hepáticas , Humanos , Masculino , Pessoa de Meia-Idade , Polissacarídeos , Software , Estatísticas não Paramétricas , Ultrassonografia
16.
Radiol Med ; 103(4): 407-13, 2002 Apr.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-12107391

RESUMO

PURPOSE: To evaluate whether the time-intensity curve can improve characterisation of solitary thyroid nodules. MATERIAL AND METHODS: From June to December 2000 we studied 61 patients (16 men and 45 women, mean age 46 years) with solitary thyroid nodules that were not associated with any important hormonal alteration and that showed poor tracer uptake at scintigraphy. We evaluated the Power Doppler vascular pattern before and after a 60" intravenous injection of 2.5 g of Levovist (diluted in 7 ml). The study lasted 5 minutes from the beginning of the infusion. Finally, the time-intensity curves were processed. All the nodules underwent fine needle aspiration biopsy (FNAB) and excision biopsy. RESULTS: Histology revealed 43 benign lesions and 18 malignant lesions. At contrast-enhanced Power Doppler 83.4% (15/18) of the malignant nodules were found to be hypervascularized, while 16.6% (3/18) were hypovascularized. Of the benign lesions, 90.7% (39/43) were hypervascularized, 9.3% (4/43) were hypovascularized. All the nodules, both hyper- and hypovascularized, displayed rapid and intense wash-in curves. By contrast, the wash-out curves were regular and monophasic in 40/43 (93%) benign lesions (36 hypervascularized and 4 hypovascularized lesions) and irregular and polyphasic in 16/18 (89%) malignant lesions (13 hypervascularized and 3 hypovascularized lesions); 3/43 (7%) benign nodules showed polyphasic wash-out and 2/18 malignant lesions (11%) showed monophasic wash-out. DISCUSSION AND CONCLUSIONS: Time-intensity curves, and particularly wash-out curves, provide useful information for the characterisation of solitary thyroid nodules. 93% of benign nodules (with regular vascularization) showed a monophasic pattern of the wash-out curve, while 89% of malignant nodules ("anarchical" vascularization) had polyphasic wash-out curves. This behaviour was observed in both hypervascularized and hypovascularized lesions. Our method proved to have a sensitivity of 88% and a specificity of 93%. The study of time-intensity curves could therefore enable us to differentiate between benign and malignant lesions and characterise hypovascularized malignant nodules which would not be observed without contrast agent.


Assuntos
Meios de Contraste/farmacocinética , Polissacarídeos/farmacocinética , Nódulo da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia Doppler , Adulto , Idoso , Biópsia por Agulha , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Nódulo da Glândula Tireoide/patologia
17.
Eur J Radiol ; 27 Suppl 2: S254-8, 1998 May.
Artigo em Inglês | MEDLINE | ID: mdl-9652531

RESUMO

The authors report the results obtained with color Doppler sonography in the study of breast conditions. Color Doppler allows to detect the following main features in breast conditions: the presence of blood flow, vessel arrangement, vascularization extent, the number of vascular poles. To investigate slow flows, it is better to use low PRF values (not above 1 KHz) and low filters, while amplification should be set immediately above the system's noise threshold; the size of color Doppler box should be adjusted as small as possible to maximize sensitivity and minimize flash artifacts. In May 1992 to September 1997, 252 patients with solid breast masses were examined with mammography, B-mode, color Doppler and power Doppler sonography (only 57 cases). We identified histologically (176 cases) or cytologically (77 cases) 141 carcinomas and 112 benign solid lesions. The diameter of the 141 carcinomas ranged 0.4-4 cm (mean 1.7), while the diameter of benign lesions ranged 0.7-3 cm (mean 1.5). The malignancy pattern was characterized by hypervascularity (92.9%), irregular and abundant (54.2%) vascularization and more than one vascular pole. Benign lesions were avascular (43.4%) with poor and peripheral vascularity (90%) and mostly showed only one vascular pole. The avascular cancers (10 cases) were three mucoid, five in situ and two small (0.7 and 0.9 cm) invasive ductal carcinomas. The six benign lesions with irregular and abundant vascularization and more than one vascular pole were proved to be two proliferating and three juvenile fibroadenomas and one phylloid tumor. These results are encouraging and suggest that this technique can be a useful adjunct to mammography and sonography in the differential, diagnosis of breast nodules.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Ultrassonografia Mamária , Adulto , Idoso , Mama/irrigação sanguínea , Doenças Mamárias/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Sensibilidade e Especificidade
18.
Radiol Med ; 93(1-2): 61-6, 1997.
Artigo em Italiano | MEDLINE | ID: mdl-9380870

RESUMO

Graves disease is an organ-specific autoimmune disorder characterized by variable clinical and laboratory patterns and by alternating remissions and relapses. We investigated if a correlation exists between the hypervascular pattern of Graves disease, studied with color Doppler US (CDUS), and the degree of thyroid hyperfunction, estimated according to biohumoral parameters. We also investigated if CDUS can differentiate, with the help of pathologic correlations, the glandular histologic patterns recently reported in the literature in thyroidectomized patients. Forty-five patients with Graves disease were selected and submitted, in the same day, to CDUS and to a clinical biohumoral test, including hormone and antibody assays. Eight of these patients had undergone total thyroidectomy. The following variables were studied in each patient: US structure and glandular thickness, color spot distribution, VP, R1, T3, T4, TRab, Tmab, Tgab and patient's age. Thirty-three normal volunteers were also examined. CDUS demonstrated two patterns: pattern A consisted in many homogeneous and bilobed color spots all over the glandular structure; pattern B consisted in color spots areas and/or vascular bands surrounding avascular areas. Pattern A was seen in 13/45 patients (28.9%) and pattern B in 32/45 (71.1%). The subdivision into two groups showed significant differences from a statistical point of view (0.05 > p > 0.001) in relation to the following indices: Vp, T3 and gland size. Of the 8 patients submitted to total thyroidectomy, 3 had pattern A and 5 had pattern B at CDUS. Histology showed major differences between the two groups: thus, thyroidectomized patients with pattern B had thickened interlobular septa and more nodules. with reduced vascular component. Our study confirms that CDUS can diagnose hyperthyroidism; moreover, this technique seems to be capable of differentiating, with the help of color and flow velocity analyses, two different abnormal patterns, which we called A and B. The early results of this preliminary study seem to indicate that CDUS can show two distinct patterns of Graves disease, which differ from a histologic viewpoint and probably also in clinical aggressiveness.


Assuntos
Doença de Graves/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
19.
Radiol Med ; 90(6): 714-8, 1995 Dec.
Artigo em Italiano | MEDLINE | ID: mdl-8685454

RESUMO

PURPOSE: To investigate the diagnostic capabilities of the stereotaxic technique in characterizing suspicious mammographic findings for which stereotaxic FNAB is indicated. METHOD: January, 1990, through December, 1992, 871 patients underwent stereotaxic mammograms preliminary to FNAB; in 12 of them (1.4%) mammography could rule out the malignant nature of the lesions, thus making FNAB useless. MATERIAL: Stereotaxic images were acquired with a conventional mammographic unit (Senographe 500 or 600T CGR-GE). An average 34 months' mammographic follow-up confirmed the absence of malignancy in the above patients. The most common glandular structure in these patients was investigated, together with the type of nonpalpable lesions found on conventional mammograms (opacity, local distortion or scar, microcalcification without a mass) and the reasons why FNAB was unfeasible, or useless. In our patients FNAB was unfeasible mostly in fatty breasts (9/12), while lesion type was not relevant for screening. The lesions were 5/12 distortion, 5/12 small opacities and 2/12 clusters of small microcalcifications. In 9/12 patients FNAB was not performed because the image observed on conventional exams had disappeared, in 2/12 patients with microcalcifications because they were scattered on a large glandular area and in 1/12 patients because vascular sinuosity was diagnosed.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Mamografia/métodos , Técnicas Estereotáxicas , Adulto , Biópsia por Agulha , Mama/patologia , Calcinose/diagnóstico por imagem , Citodiagnóstico , Feminino , Humanos , Pessoa de Meia-Idade , Palpação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...