Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 222
Filtrar
1.
Med Phys ; 2024 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-38762909

RESUMO

BACKGROUND: Ultra-high-dose-rate (UHDR) electron beams have been commonly utilized in FLASH studies and the translation of FLASH Radiotherapy (RT) to the clinic. The EDGE diode detector has potential use for UHDR dosimetry albeit with a beam energy dependency observed. PURPOSE: The purpose is to present the electron beam response for an EDGE detector in dependence on beam energy, to characterize the EDGE detector's response under UHDR conditions, and to validate correction factors derived from the first detailed Monte Carlo model of the EDGE diode against measurements, particularly under UHDR conditions. METHODS: Percentage depth doses (PDDs) for the UHDR Mobetron were measured with both EDGE detectors and films. A detailed Monte Carlo (MC) model of the EDGE detector has been configured according to the blueprint provided by the manufacturer under an NDA agreement. Water/silicon dose ratios of EDGE detector for a series of mono-energetic electron beams have been calculated. The dependence of the water/silicon dose ratio on depth for a FLASH relevant electron beam was also studied. An analytical approach for the correction of PDD measured with EDGE detectors was established. RESULTS: Water/silicon dose ratio decreased with decreasing electron beam energy. For the Mobetron 9 MeV UHDR electron beam, the ratio decreased from 1.09 to 1.03 in the build-up region, maintained in range of 0.98-1.02 at the fall-off region and raised to a plateau in value of 1.08 at the tail. By applying the corrections, good agreement between the PDDs measured by the EDGE detector and those measured with film was achieved. CONCLUSIONS: Electron beam response of an UHDR capable EDGE detector was derived from first principles utilizing a sophisticated MC model. An analytical approach was validated for the PDDs of UHDR electron beams. The results demonstrated the capability of EDGE detector in measuring PDDs of UHDR electron beams.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38703954

RESUMO

PURPOSE: Large, rapid extracellular oxygen transients (ΔpO2) have been measured in vivo during ultra-high dose rate radiation therapy; however, it has been unclear if they match intracellular oxygen levels. Here, the endogenously produced protoporphyrin IX (PpIX) delayed fluorescence signal was measured as an intracellular in-vivo oxygen sensor to quantify these transients, with direct comparison to extracellular pO2. Intracellular ΔpO2 is closer to the cellular DNA, the site of major radiobiological damage, and therefore should help elucidate radiochemical mechanisms of the FLASH effect and potentially be translated to human tissue measurement. METHODS AND MATERIALS: PpIX was induced in mouse skin through intraperitoneal injection of 250 mg/kg of aminolevulinic acid. The animals were also administered a 50 µL intradermal injection of 10 µM oxyphor G4 (PdG4) for phosphorescence lifetime pO2 measurement. Paired oxygen transients were quantified in leg or flank tissues while delivering 10 MeV electrons in 3 µs pulses at 360 Hz for a total dose of 10 to 28 Gy. RESULTS: Transient reductions in pO2 were quantifiable in both PpIX delayed fluorescence and oxyphor phosphorescence, corresponding to intracellular and extracellular pO2 values, respectively. Reponses were quantified for 10, 22, and 28 Gy doses, with ΔpO2 found to be proportional to the dose on average. The ΔpO2 values were dependent on initial pO2 in a logistic function. The average and standard deviations in ΔpO2 per dose were 0.56 ± 0.18 mm Hg/Gy and 0.43 ± 0.06 mm Hg/Gy for PpIX and oxyphor, respectively, for initial pO2 > 20 mm Hg. Although there was large variability in the individual animal measurements of ΔpO2, the average values demonstrated a direct and proportional correlation between intracellular and extracellular pO2 changes, following a linear 1:1 relationship. CONCLUSIONS: A fundamentally new approach to measuring intracellular oxygen depletion in living tissue showed that ΔpO2 transients seen during ultra-high dose rate radiation therapy matched those quantified using extracellular oxygen measurement. This approach could be translated to humans to quantify intracellular ΔpO2. The measurement of these transients could potentially allow the estimation of intracellular reactive oxygen species production.

3.
Adv Radiat Oncol ; 9(6): 101492, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38711960

RESUMO

Purpose: Ultra High Dose-Rate (UHDR) radiation has been reported to spare normal tissue, compared with Conventional Dose-Rate (CDR) radiation. However, important work remains to be done to improve the reproducibility of the FLASH effect. A better understanding of the biologic factors that modulate the FLASH effect may shed light on the mechanism of FLASH sparing. Here, we evaluated whether sex and/or the use of 100% oxygen as a carrier gas during irradiation contribute to the variability of the FLASH effect. Methods and Materials: C57BL/6 mice (24 male, 24 female) were anesthetized using isoflurane mixed with either room air or 100% oxygen. Subsequently, the mice received 27 Gy of either 9 MeV electron UHDR or CDR to a 1.6 cm2 diameter area of the right leg skin using the Mobetron linear accelerator. The primary postradiation endpoint was time to full thickness skin ulceration. In a separate cohort of mice (4 male, 4 female), skin oxygenation was measured using PdG4 Oxyphor under identical anesthesia conditions. Results: Neither supplemental oxygen nor sex affected time to ulceration in CDR irradiated mice. In the UHDR group, skin damage occured earlier in male and female mice that received 100% oxygen compared room air and female mice ulcerated sooner than male mice. However, there was no significant difference in time to ulceration between male and female UHDR mice that received room air. Oxygen measurements showed that tissue oxygenation was significantly higher when using 100% oxygen as the anesthesia carrier gas than when using room air, and female mice showed higher levels of tissue oxygenation than male mice under 100% oxygen. Conclusions: The skin FLASH sparing effect is significantly reduced when using oxygen during anesthesia rather than room air. FLASH sparing was also reduced in female mice compared to male mice. Both tissue oxygenation and sex are likely sources of variability in UHDR studies. These results suggest an oxygen-based mechanism for FLASH, as well as a key role for sex in the FLASH skin sparing effect.

4.
Med Phys ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38598093

RESUMO

BACKGROUND: While careful planning and pre-treatment checks are performed to ensure patient safety during external beam radiation therapy (EBRT), inevitable daily variations mean that in vivo dosimetry (IVD) is the only way to attain the true delivered dose. Several countries outside the US require daily IVD for quality assurance. However, elsewhere, the manual labor and time considerations of traditional in vivo dosimeters may be preventing frequent use of IVD in the clinic. PURPOSE: This study expands upon previous research using plastic scintillator discs for optical dosimetry for electron therapy treatments. We present the characterization of scintillator discs for in vivo x-ray dosimetry and describe additional considerations due to geometric complexities. METHODS: Plastic scintillator discs were coated with reflective white paint on all sides but the front surface. An anti-reflective, matte coating was applied to the transparent face to minimize specular reflection. A time-gated iCMOS camera imaged the discs under various irradiation conditions. In post-processing, background-subtracted images of the scintillators were fit with Gaussian-convolved ellipses to extract several parameters, including integral output, and observation angle. RESULTS: Dose linearity and x-ray energy independence were observed, consistent with ideal characteristics for a dosimeter. Dose measurements exhibited less than 5% variation for incident beam angles between 0° and 75° at the anterior surface and 0-60 ∘ $^\circ $ at the posterior surface for exit beam dosimetry. Varying the angle between the disc surface and the camera lens did not impact the integral output for the same dose up to 55°. Past this point, up to 75°, there is a sharp falloff in response; however, a correction can be used based on the detected width of the disc. The reproducibility of the integral output for a single disc is 2%, and combined with variations from the gantry angle, we report the accuracy of the proposed scintillator disc dosimeters as ±5.4%. CONCLUSIONS: Plastic scintillator discs have characteristics that are well-suited for in vivo optical dosimetry for x-ray radiotherapy treatments. Unlike typical point dosimeters, there is no inherent readout time delay, and an optical recording of the measurement is saved after treatment for future reference. While several factors influence the integral output for the same dose, they have been quantified here and may be corrected in post-processing.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38552990

RESUMO

PURPOSE: In this study, a C-series linear accelerator was configured to enable rapid and reliable conversion between the production of conventional electron beams and an ultrahigh-dose-rate (UHDR) electron beamline to the treatment room isocenter for FLASH radiation therapy. Efforts to tune the beam resulted in a consistent, stable UHDR beamline. METHODS AND MATERIALS: The linear accelerator was configured to allow for efficient switching between conventional and modified electron output modes within 2 minutes. Additions to the air system allow for retraction of the x-ray target from the beamline when the 10 MV photon mode is selected. With the carousel set to an empty port, this grants access to the higher current pristine electron beam normally used to produce clinical photon fields. Monitoring signals related to the automatic frequency control system allows for tuning of the waveguide while the machine is in a hold state so a stable beam is produced from the initial pulse. A pulse counting system implemented on an field-programmable gate array-based controller platform controls the delivery to a desired number of pulses. Beam profiles were measured with Gafchromic film. Pulse-by-pulse dosimetry was measured using a custom electrometer designed around the EDGE diode. RESULTS: This method reliably produces a stable UHDR electron beam. Open-field measurements of the 16-cm full-width, half-maximum gaussian beam saw average dose rates of 432 Gy/s at treatment isocenter. Pulse overshoots were limited and ramp up was eliminated. Over the last year, there have been no recorded incidents that resulted in machine downtime due to the UHDR conversions. CONCLUSIONS: Stable 10 MeV UHDR beams were generated to produce an average dose rate of 432 Gy/s at the treatment room isocenter. With a reliable pulse-counting beam control system, consistent doses can be delivered for FLASH experiments with the ability to accommodate a wide range of field sizes, source-to-surface distances, and other experimental apparatus that may be relevant for future clinical translation.

6.
Eur J Gen Pract ; 30(1): 2327367, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38497412

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a common treatable risk factor for stroke. Screening for paroxysmal AF in general practice is difficult, but biomarkers might help improve screening strategies. OBJECTIVES: We investigated six blood biomarkers for predicting paroxysmal AF in general practice. METHODS: This was a pre-specified sub-study of the SCREEN-AF RCT done in Germany. Between 12/2017-03/2019, we enrolled ambulatory individuals aged 75 years or older with a history of hypertension but without known AF. Participants in the intervention group received active AF screening with a wearable patch, continuous ECG monitoring for 2x2 weeks and usual care in the control group. The primary endpoint was ECG-confirmed AF within six months after randomisation. High-sensitive Troponin I (hsTnI), brain natriuretic peptide (BNP), N-terminal pro-B-type natriuretic peptide (NT-pro BNP), N-terminal pro atrial natriuretic peptide (NT-ANP), mid-regional pro atrial natriuretic peptide (MR-pro ANP) and C-reactive protein (CRP) plasma levels were investigated at randomisation for predicting AF within six months after randomisation. RESULTS: Blood samples were available for 291 of 301 (96.7%) participants, including 8 with AF (3%). Five biomarkers showed higher median results in AF-patients: BNP 78 vs. 41 ng/L (p = 0.012), NT-pro BNP 273 vs. 186 ng/L (p = 0.029), NT-proANP 4.4 vs. 3.5 nmol/L (p = 0.027), MR-pro ANP 164 vs. 125 pmol/L (p = 0.016) and hsTnI 7.4 vs. 3.9 ng/L (p = 0.012). CRP levels were not different between groups (2.8 vs 1.9 mg/L, p = 0.1706). CONCLUSION: Natriuretic peptide levels and hsTnI are higher in patients with AF than without and may help select patients for AF screening, but larger trials are needed.


BNP, NT-pro BNP, NT-ANP and MR-pro ANP and hsTnI levels are higher in patients with AF than without AFWith a sensitivity at 100%, BNP had the highest specificity of 60% (BNP level 50.1ng/L), followed by NT-pro BNP with a specificity of 53% (179ng/l).


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fator Natriurético Atrial , Biomarcadores , Alemanha
7.
Med Phys ; 2024 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-38493501

RESUMO

BACKGROUND: FLASH radiotherapy based on ultra-high dose rate (UHDR) is actively being studied by the radiotherapy community. Dedicated UHDR electron devices are currently a mainstay for FLASH studies. PURPOSE: To present the first Monte Carlo (MC) electron beam model for the UHDR capable Mobetron (FLASH-IQ) as a dose calculation and treatment planning platform for preclinical research and FLASH-radiotherapy (RT) clinical trials. METHODS: The initial beamline geometry of the Mobetron was provided by the manufacturer, with the first-principal implementation realized in the Geant4-based GAMOS MC toolkit. The geometry and electron source characteristics, such as energy spectrum and beamline parameters, were tuned to match the central-axis percentage depth dose (PDD) and lateral profiles for the pristine beam measured during machine commissioning. The thickness of the small foil in secondary scatter affected the beam model dominantly and was fine tuned to achieve the best agreement with commissioning data. Validation of the MC beam modeling was performed by comparing the calculated PDDs and profiles with EBT-XD radiochromic film measurements for various combinations of applicators and inserts. RESULTS: The nominal 9 MeV electron FLASH beams were best represented by a Gaussian energy spectrum with mean energy of 9.9 MeV and variance (σ) of 0.2 MeV. Good agreement between the MC beam model and commissioning data were demonstrated with maximal discrepancy < 3% for PDDs and profiles. Hundred percent gamma pass rate was achieved for all PDDs and profiles with the criteria of 2 mm/3%. With the criteria of 2 mm/2%, maximum, minimum and mean gamma pass rates were (100.0%, 93.8%, 98.7%) for PDDs and (100.0%, 96.7%, 99.4%) for profiles, respectively. CONCLUSIONS: A validated MC beam model for the UHDR capable Mobetron is presented for the first time. The MC model can be utilized for direct dose calculation or to generate beam modeling input required for treatment planning systems for FLASH-RT planning. The beam model presented in this work should facilitate translational and clinical FLASH-RT for trials conducted on the Mobetron FLASH-IQ platform.

8.
Phys Med Biol ; 69(7)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38422545

RESUMO

Objective. Imaging of optical photons emitted from tissue during radiotherapy is a promising technique for real-time visualization of treatment delivery, offering applications in dose verification, treatment monitoring, and retrospective treatment plan comparison. This research aims to explore the feasibility of intensified imaging of tissue luminescence during proton therapy (PT), under both conventional and ultra-high dose rate (UHDR) conditions.Approach. Conventional and UHDR pencil beam scanning (PBS) PT irradiation of freshex vivoporcine tissue and tissue-mimicking plastic phantom was imaged using intensified complementary metal-oxide-semiconductor(CMOS) cameras. The optical emission from tissue was characterized during conventional irradiation using both blue and red-sensitive intensifiers to ensure adequate spectral coverage. Spectral characterization was performed using bandpass filters between the lens and sensor. Imaging of conventional proton fields (240 MeV, 10 nA) was performed at 100 Hz frame rate, while UHDR PBS proton delivery (250 MeV, 99 nA) was recorded at 1 kHz frame rate. Dependence of optical emission yield on proton energy was studied using an optical tissue-mimicking plastic phantom and a range shifter. Finally, we demonstrated fast beam tracking capability of fast camera towardsin vivomonitoring of FLASH PT.Main results. Under conventional treatment dose rates optical emission was imaged with single spot resolution. Spot profiles were found to agree with the treatment planning system calculation within >90% for all spectral bands and spot intensity was found to vary with spectral filtration. The resultant polychromatic emission presented a maximum intensity at 650 nm and decreasing signal at lower wavelengths, which is consistent with expected attenuation patterns of high fat and muscle tissue. For UHDR beam imaging, optical yield increased with higher proton energy. Imaging at 1 kHz allowed continuous monitoring of delivery during porcine tissue irradiation, with clear identification of individual dwell positions. The number of dwell positions matched the treatment plan in total and per row showing adequate temporal capability of iCMOS imaging.Significance. For the first time, this study characterizes optical emission from tissue during PT and demonstrates our capability of fast optical tracking of pencil proton beam on the tissue anatomy in both conventional and UHDR setting. Similar to the Cherenkov imaging in radiotherapy, this imaging modality could enable a seamless, independent validation of PT treatments.


Assuntos
Terapia com Prótons , Animais , Suínos , Terapia com Prótons/métodos , Prótons , Estudos Retrospectivos , Diagnóstico por Imagem , Imagens de Fantasmas
9.
JAMA ; 331(7): 573-581, 2024 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-38324415

RESUMO

Importance: Atrial cardiopathy is associated with stroke in the absence of clinically apparent atrial fibrillation. It is unknown whether anticoagulation, which has proven benefit in atrial fibrillation, prevents stroke in patients with atrial cardiopathy and no atrial fibrillation. Objective: To compare anticoagulation vs antiplatelet therapy for secondary stroke prevention in patients with cryptogenic stroke and evidence of atrial cardiopathy. Design, Setting, and Participants: Multicenter, double-blind, phase 3 randomized clinical trial of 1015 participants with cryptogenic stroke and evidence of atrial cardiopathy, defined as P-wave terminal force greater than 5000 µV × ms in electrocardiogram lead V1, serum N-terminal pro-B-type natriuretic peptide level greater than 250 pg/mL, or left atrial diameter index of 3 cm/m2 or greater on echocardiogram. Participants had no evidence of atrial fibrillation at the time of randomization. Enrollment and follow-up occurred from February 1, 2018, through February 28, 2023, at 185 sites in the National Institutes of Health StrokeNet and the Canadian Stroke Consortium. Interventions: Apixaban, 5 mg or 2.5 mg, twice daily (n = 507) vs aspirin, 81 mg, once daily (n = 508). Main Outcomes and Measures: The primary efficacy outcome in a time-to-event analysis was recurrent stroke. All participants, including those diagnosed with atrial fibrillation after randomization, were analyzed according to the groups to which they were randomized. The primary safety outcomes were symptomatic intracranial hemorrhage and other major hemorrhage. Results: With 1015 of the target 1100 participants enrolled and mean follow-up of 1.8 years, the trial was stopped for futility after a planned interim analysis. The mean (SD) age of participants was 68.0 (11.0) years, 54.3% were female, and 87.5% completed the full duration of follow-up. Recurrent stroke occurred in 40 patients in the apixaban group (annualized rate, 4.4%) and 40 patients in the aspirin group (annualized rate, 4.4%) (hazard ratio, 1.00 [95% CI, 0.64-1.55]). Symptomatic intracranial hemorrhage occurred in 0 patients taking apixaban and 7 patients taking aspirin (annualized rate, 1.1%). Other major hemorrhages occurred in 5 patients taking apixaban (annualized rate, 0.7%) and 5 patients taking aspirin (annualized rate, 0.8%) (hazard ratio, 1.02 [95% CI, 0.29-3.52]). Conclusions and Relevance: In patients with cryptogenic stroke and evidence of atrial cardiopathy without atrial fibrillation, apixaban did not significantly reduce recurrent stroke risk compared with aspirin. Trial Registration: ClinicalTrials.gov Identifier: NCT03192215.


Assuntos
Fibrilação Atrial , Cardiopatias , AVC Isquêmico , Pirazóis , Acidente Vascular Cerebral , Humanos , Feminino , Idoso , Masculino , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Método Duplo-Cego , Canadá , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Aspirina/efeitos adversos , Piridonas/efeitos adversos , Piridonas/administração & dosagem , Hemorragia/induzido quimicamente , Hemorragia/tratamento farmacológico , Cardiopatias/complicações , AVC Isquêmico/tratamento farmacológico , Anticoagulantes/efeitos adversos , Anticoagulantes/administração & dosagem , Hemorragias Intracranianas/induzido quimicamente
10.
Stroke ; 55(3): 524-531, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38275116

RESUMO

BACKGROUND: Recent evidence from thrombolysis trials indicates the noninferiority of intravenous tenecteplase to intravenous alteplase with respect to good functional outcomes in patients with acute stroke. We examined whether the health-related quality of life (HRQOL) of patients with acute stroke differs by the type of thrombolysis treatment received. In addition, we examined the association between the modified Rankin Scale score 0 to 1 and HRQOL and patient-reported return to prebaseline stroke functioning at 90 days. METHODS: Data were from all patients included in the AcT trial (Alteplase Compared to Tenecteplase), a pragmatic, registry-linked randomized trial comparing tenecteplase with alteplase. HRQOL at 90-day post-randomization was assessed using the 5-item EuroQOL questionnaire (EQ5D), which consists of 5 items and a visual analog scale (VAS). EQ5D index values were estimated from the EQ5D items using the time tradeoff approach based on Canadian norms. Tobit regression and quantile regression models were used to evaluate the adjusted effect of tenecteplase versus alteplase treatment on the EQ5D index values and VAS score, respectively. The association between return to prebaseline stroke functioning and the modified Rankin Scale score 0 to 1 and HRQOL was quantified using correlation coefficient (r) with 95% CI. RESULTS: Of 1577 included in the intention-to-treat analysis patients, 1503 (95.3%) had complete data on the EQ5D. Of this, 769 (51.2%) were administered tenecteplase and 717 (47.7%) were female. The mean EQ5D VAS score and EQ5D index values were not significantly higher for those who received intravenous tenecteplase compared with those who received intravenous alteplase (P=0.10). Older age (P<0.01), more severe stroke assessed using the National Institutes of Health Stroke Scale (P<0.01), and longer stroke onset-to-needle time (P=0.004) were associated with lower EQ5D index and VAS scores. There was a strong association (r, 0.85 [95% CI, 0.81-0.89]) between patient-reported return to prebaseline functioning and modified Rankin Scale score 0 to 1 Similarly, there was a moderate association between return to prebaseline functioning and EQ5D index (r, 0.45 [95% CI, 0.40-0.49]) and EQ5D VAS scores (r, 0.42 [95% CI, 0.37-0.46]). CONCLUSIONS: Although there is no differential effect of thrombolysis type on patient-reported global HRQOL and EQ 5D-5L index values in patients with acute stroke, sex- and age-related differences in HRQOL were noted in this study. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03889249.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Feminino , Masculino , Ativador de Plasminogênio Tecidual , Tenecteplase/efeitos adversos , Fibrinolíticos , AVC Isquêmico/tratamento farmacológico , Qualidade de Vida , Isquemia Encefálica/tratamento farmacológico , Isquemia Encefálica/induzido quimicamente , Canadá , Acidente Vascular Cerebral/tratamento farmacológico , Acidente Vascular Cerebral/induzido quimicamente , Terapia Trombolítica , Resultado do Tratamento
12.
bioRxiv ; 2023 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-37961549

RESUMO

Introduction: Ultra-high dose-rate (UHDR) radiation has been reported to spare normal tissue compared to conventional dose-rate (CDR) radiation. However, reproducibility of the FLASH effect remains challenging due to varying dose ranges, radiation beam structure, and in-vivo endpoints. A better understanding of these inconsistencies may shed light on the mechanism of FLASH sparing. Here, we evaluate whether sex and/or use of 100% oxygen as carrier gas during irradiation contribute to the variability of the FLASH effect. Methods: C57BL/6 mice (24 male, 24 female) were anesthetized using isoflurane mixed with either room air or 100% oxygen. Subsequently, the mice received 27 Gy of either 9 MeV electron UHDR or CDR to a 1.6 cm2 diameter area of the right leg skin using the Mobetron linear accelerator. The primary post-radiation endpoint was time to full thickness skin ulceration. In a separate cohort of mice (4 male, 4 female) skin oxygenation was measured using PdG4 Oxyphor under identical anesthesia conditions. Results: In the UHDR group, time to ulceration was significantly shorter in mice that received 100% oxygen compared to room air, and amongst them female mice ulcerated sooner compared to males. However, no significant difference was observed between male and female UHDR mice that received room air. Oxygen measurements showed significantly higher tissue oxygenation using 100% oxygen as the anesthesia carrier gas compared to room air, and female mice showed higher levels of tissue oxygenation compared to males under 100% oxygen. Conclusion: The FLASH sparing effect is significantly reduced using oxygen during anesthesia compared to room air. The FLASH sparing was significantly lower in female mice compared to males. Both tissue oxygenation and sex are likely sources of variability in UHDR studies. These results suggest an oxygen-based mechanism for FLASH, as well as a key role for sex in the FLASH skin sparing effect.

13.
Radiat Res ; 200(3): 223-231, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37590482

RESUMO

Recent studies suggest ultra-high dose rate radiation treatment (UHDR-RT) reduces normal tissue damage compared to conventional radiation treatment (CONV-RT) at the same dose. In this study, we compared first, the kinetics and degree of skin damage in wild-type C57BL/6 mice, and second, tumor treatment efficacy in GL261 and B16F10 dermal tumor models, at the same UHDR-RT and CONV-RT doses. Flank skin of wild-type mice received UHDR-RT or CONV-RT at 25 Gy and 30 Gy. Normal skin damage was tracked by clinical observation to determine the time to moist desquamation, an endpoint which was verified by histopathology. Tumors were inoculated on the right flank of the mice, then received UHDR-RT or CONV-RT at 1 × 11 Gy, 1 × 15, 1 × 25, 3 × 6 and 3 × 8 Gy, and time to tumor tripling volume was determined. Tumors also received 1 × 11, 1 × 15, 3 × 6 and 3 × 8 Gy doses for assessment of CD8+/CD4+ tumor infiltrate and genetic expression 96 h postirradiation. All irradiations of the mouse tumor or flank skin were performed with megavoltage electron beams (10 MeV, 270 Gy/s for UHDR-RT and 9 MeV, 0.12 Gy/s for CONV-RT) delivered via a clinical linear accelerator. Tumor control was statistically equal for similar doses of UHDR-RT and CONV-RT in B16F10 and GL261 murine tumors. There were variable qualitative differences in genetic expression of immune and cell damage-associated pathways between UHDR and CONV irradiated B16F10 tumors. Compared to CONV-RT, UHDR-RT resulted in an increased latent period to skin desquamation after a single 25 Gy dose (7 days longer). Time to moist skin desquamation did not significantly differ between UHDR-RT and CONV-RT after a 30 Gy dose. The histomorphological characteristics of skin damage were similar for UHDR-RT and CONV-RT. These studies demonstrated similar tumor control responses for equivalent single and fractionated radiation doses, with variable difference in expression of tumor progression and immune related gene pathways. There was a modest UHDR-RT skin sparing effect after a 1 × 25 Gy dose but not after a 1 × 30 Gy dose.


Assuntos
Neoplasias , Lesões por Radiação , Camundongos , Animais , Camundongos Endogâmicos C57BL , Pele/efeitos da radiação , Neoplasias/patologia , Modelos Animais de Doenças , Lesões por Radiação/patologia , Dosagem Radioterapêutica
14.
Int J Mol Sci ; 24(15)2023 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-37569869

RESUMO

We assessed the effects of conventional and ultra-high dose rate (UHDR) electron irradiation on behavioral and cognitive performance one month following exposure and assessed whether these effects were associated with alterations in the number of immune cells in the hippocampus using flow cytometry. Two-month-old female and male C57BL/6J mice received whole-brain conventional or UHDR irradiation. UHDR mice were irradiated with 9 MeV electrons, delivered by the Linac-based/modified beam control. The mice were irradiated or sham-irradiated at Dartmouth, the following week shipped to OHSU, and behaviorally and cognitively tested between 27 and 41 days after exposure. Conventional- and UHDR-irradiated mice showed impaired novel object recognition. During fear learning, conventional- and UHDR-irradiated mice moved less during the inter-stimulus interval (ISI) and UHDR-irradiated mice also moved less during the baseline period (prior to the first tone). In irradiated mice, reduced activity levels were also seen in the home cage: conventional- and UHDR-irradiated mice moved less during the light period and UHDR-irradiated mice moved less during the dark period. Following behavioral and cognitive testing, infiltrating immune cells in the hippocampus were analyzed by flow cytometry. The percentage of Ly6G+ CD45+ cells in the hippocampus was lower in conventional- and UHDR-irradiated than sham-irradiated mice, suggesting that neutrophils might be particularly sensitive to radiation. The percentage of Ly6G+ CD45+ cells in the hippocampus was positively correlated with the time spent exploring the novel object in the object recognition test. Under the experimental conditions used, cognitive injury was comparable in conventional and UHDR mice. However, the percentage of CD45+ CD11b+ Ly6+ and CD45+ CD11b+ Ly6G- cells in the hippocampus cells in the hippocampus was altered in conventional- but not UHDR-irradiated mice and the reduced percentage of Ly6G+ CD45+ cells in the hippocampus might mediate some of the detrimental radiation-induced cognitive effects.


Assuntos
Hipocampo , Lesões por Radiação , Masculino , Feminino , Animais , Camundongos , Camundongos Endogâmicos C57BL , Hipocampo/efeitos da radiação , Encéfalo/efeitos da radiação , Aprendizagem , Cognição/efeitos da radiação
15.
Phys Med Biol ; 68(16)2023 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-37463588

RESUMO

Objective. The objective of this study was to investigate the impact of mean and instantaneous dose rates on the production of reactive oxygen species (ROS) during ultra-high dose rate (UHDR) radiotherapy. The study aimed to determine whether either dose rate type plays a role in driving the FLASH effect, a phenomenon where UHDR radiotherapy reduces damage to normal tissues while maintaining tumor control.Approach. Assays of hydrogen peroxide (H2O2) production and oxygen consumption (ΔpO2) were conducted using UHDR electron irradiation. Aqueous solutions of 4% albumin were utilized as the experimental medium. The study compared the effects of varying mean dose rates and instantaneous dose rates on ROS yields. Instantaneous dose rate was varied by changing the source-to-surface distance (SSD), resulting in instantaneous dose rates ranging from 102to 106Gy s-1. Mean dose rate was manipulated by altering the pulse frequency of the linear accelerator (linac) and by changing the SSD, ranging from 0.14 to 1500 Gy s-1.Main results. The study found that both ΔH2O2and ΔpO2decreased as the mean dose rate increased. Multivariate analysis indicated that instantaneous dose rates also contributed to this effect. The variation in ΔpO2was dependent on the initial oxygen concentration in the solution. Based on the analysis of dose rate variation, the study estimated that 7.51 moles of H2O2were produced for every mole of O2consumed.Significance. The results highlight the significance of mean dose rate as a predictor of ROS production during UHDR radiotherapy. As the mean dose rate increased, there was a decrease in oxygen consumption and in H2O2production. These findings have implications for understanding the FLASH effect and its potential optimization. The study sheds light on the role of dose rate parameters and their impact on radiochemical outcomes, contributing to the advancement of UHDR radiotherapy techniques.


Assuntos
Elétrons , Peróxido de Hidrogênio , Espécies Reativas de Oxigênio , Oxigênio , Frequência Cardíaca , Dosagem Radioterapêutica
16.
Med Phys ; 50(9): 5875-5883, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37249058

RESUMO

BACKGROUND: Ultra-high dose rate (UHDR) FLASH beams typically deliver dose at rates of  >40 Gy/sec. Characterization of these beams with respect to dose, mean dose rate, and dose per pulse requires dosimeters which exhibit high temporal resolution and fast readout capabilities. PURPOSE: A diode EDGE Detector with a newly designed electrometer has been characterized for use in an UHDR electron beam and demonstrated appropriateness for UHDR FLASH radiotherapy dosimetry. METHODS: Dose linearity, mean dose rate, and dose per pulse dependencies of the EDGE Detector were quantified and compared with dosimeters including a W1 scintillator detector, radiochromic film, and ionization chamber that were irradiated with a 10 MeV UHDR beam. The dose, dose rate, and dose per pulse were controlled via an in-house developed scintillation-based feedback mechanism, repetition rate of the linear accelerator, and source-to-surface distance, respectively. Depth-dose profiles and temporal profiles at individual pulse resolution were compared to the film and scintillation measurements, respectively. The radiation-induced change in response sensitivity was quantified via irradiation of ∼5kGy. RESULTS: The EDGE Detector agreed with film measurements in the measured range with varying dose (up to 70 Gy), dose rate (nearly 200 Gy/s), and dose per pulse (up to 0.63 Gy/pulse) on average to within 2%, 5%, and 1%, respectively. The detector also agreed with W1 scintillation detector on average to within 2% for dose per pulse (up to 0.78 Gy/pulse). The EDGE Detector signal was proportional to ion chamber (IC) measured dose, and mean dose rate in the bremsstrahlung tail to within 0.4% and 0.2% respectively. The EDGE Detector measured percent depth dose (PDD) agreed with film to within 3% and per pulse output agreed with W1 scintillator to within -6% to +5%. The radiation-induced response decrease was 0.4% per kGy. CONCLUSIONS: The EDGE Detector demonstrated dose linearity, mean dose rate independence, and dose per pulse independence for UHDR electron beams. It can quantify the beam spatially, and temporally at sub millisecond resolution. It's robustness and individual pulse detectability of treatment deliveries can potentially lead to its implementation for in vivo FLASH dosimetry, and dose monitoring.


Assuntos
Dosimetria in Vivo , Dosímetros de Radiação , Radiometria/métodos , Aceleradores de Partículas
17.
J Appl Clin Med Phys ; 24(6): e14037, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37211701

RESUMO

Medical physics doctoral programs have large variations in organization, administration and financing. Blending a medical physics stream into an engineering graduate program has advantages of pre-existing financial and educational infrastructures. A case study of the accredited program at Dartmouth was carried out, analyzing operational, financial, educational and outcome features. The support structures provided by each institutional partner were outlined, including engineering school, graduate school, and radiation oncology. The initiatives undertaken by founding faculty were reviewed, along with allocated resources, financial model, and peripheral entrepreneurship activities, each with quantitative outcome metrics. Currently 14 PhD students are enrolled, supported by 22 faculty across both engineering and clinical departments. The total peer-reviewed publications are ≈75/year, while the conventional medical physics fraction of this is about 14/year. Following program formation, a significant rise was seen in jointly published papers between engineering and medical physics faculty, up from 5.6 to 13.3 papers/year, with students publishing an average of 11.3/person with 5.7/person as first author. Student support was predominantly via federal grants, with a stable $5.5million/year, using about $610K/year supporting student stipends and tuition. First year funding, recruiting and staff support were via engineering school. Faculty teaching effort was supported by agreement with each home department, and student services were provided by engineering and graduate schools. Student outcomes were exceptional, with high numbers of presentations, awards, and residency placements at research universities. The lack of financial and student support in medical physics can be mitigated by this hybrid design of blending medical physics doctoral students into an engineering graduate program, providing complementary strengths. Future growth in medical physics programs might consider following this pathway, strengthening research collaborations for clinical physics and engineering faculty, as long as there is vested commitment to teach by the faculty and department leadership.


Assuntos
Internato e Residência , Estudantes de Medicina , Humanos , Docentes , Física
18.
J Am Heart Assoc ; 12(8): e026681, 2023 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-37026540

RESUMO

Background For patients with atrial fibrillation seen in the emergency department (ED) following a transient ischemic attack (TIA) or minor stroke, the impact of initiating oral anticoagulation immediately rather than deferring the decision to outpatient follow-up is unknown. Methods and Results We conducted a planned secondary data analysis of a prospective cohort of 11 507 adults in 13 Canadian EDs between 2006 and 2018. Patients were eligible if they were aged 18 years or older, with a final diagnosis of TIA or minor stroke with previously documented or newly diagnosed atrial fibrillation. The primary outcome was subsequent stroke, recurrent TIA, or all-cause mortality within 90 days of the index TIA diagnosis. Secondary outcomes included stroke, recurrent TIA, or death and rates of major bleeding. Of 11 507 subjects with TIA/minor stroke, atrial fibrillation was identified in 11.2% (1286, mean age, 77.3 [SD 11.1] years, 52.4% male). Over half (699; 54.4%) were already taking anticoagulation, 89 (6.9%) were newly prescribed anticoagulation in the ED. By 90 days, 4.0% of the atrial fibrillation cohort had experienced a subsequent stroke, 6.5% subsequent TIA, and 2.6% died. Results of a multivariable logistic regression indicate no association between prescribed anticoagulation in the ED and these 90-day outcomes (composite odds ratio, 1.37 [95% CI, 0.74-2.52]). Major bleeding was found in 5 patients, none of whom were in the ED-initiated anticoagulation group. Conclusions Initiating oral anticoagulation in the ED following new TIA was not associated with lower recurrence rates of neurovascular events or all-cause mortality in patients with atrial fibrillation.


Assuntos
Fibrilação Atrial , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Humanos , Masculino , Idoso , Feminino , Ataque Isquêmico Transitório/tratamento farmacológico , Ataque Isquêmico Transitório/epidemiologia , Ataque Isquêmico Transitório/prevenção & controle , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Estudos Prospectivos , Canadá/epidemiologia , Recidiva Local de Neoplasia/complicações , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Anticoagulantes/efeitos adversos , Fatores de Risco
19.
Can Assoc Radiol J ; 74(4): 713-722, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37070854

RESUMO

PURPOSE: Rapid identification of hematoma expansion (HE) risk at baseline is a priority in intracerebral hemorrhage (ICH) patients and may impact clinical decision making. Predictive scores using clinical features and Non-Contract Computed Tomography (NCCT)-based features exist, however, the extent to which each feature set contributes to identification is limited. This paper aims to investigate the relative value of clinical, radiological, and radiomics features in HE prediction. METHODS: Original data was retrospectively obtained from three major prospective clinical trials ["Spot Sign" Selection of Intracerebral Hemorrhage to Guide Hemostatic Therapy (SPOTLIGHT)NCT01359202; The Spot Sign for Predicting and Treating ICH Growth Study (STOP-IT)NCT00810888] Patients baseline and follow-up scans following ICH were included. Clinical, NCCT radiological, and radiomics features were extracted, and multivariate modeling was conducted on each feature set. RESULTS: 317 patients from 38 sites met inclusion criteria. Warfarin use (p=0.001) and GCS score (p=0.046) were significant clinical predictors of HE. The best performing model for HE prediction included clinical, radiological, and radiomic features with an area under the curve (AUC) of 87.7%. NCCT radiological features improved upon clinical benchmark model AUC by 6.5% and a clinical & radiomic combination model by 6.4%. Addition of radiomics features improved goodness of fit of both clinical (p=0.012) and clinical & NCCT radiological (p=0.007) models, with marginal improvements on AUC. Inclusion of NCCT radiological signs was best for ruling out HE whereas the radiomic features were best for ruling in HE. CONCLUSION: NCCT-based radiological and radiomics features can improve HE prediction when added to clinical features.


Assuntos
Hemorragia Cerebral , Hematoma , Humanos , Estudos Retrospectivos , Estudos Prospectivos , Hemorragia Cerebral/diagnóstico por imagem , Hematoma/diagnóstico por imagem , Tomografia Computadorizada por Raios X
20.
Eur Stroke J ; 8(1): 106-116, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-37021198

RESUMO

Introduction: Prolonged cardiac monitoring (PCM) substantially improves the detection of subclinical atrial fibrillation (AF) among patients with history of ischemic stroke (IS), leading to prompt initiation of anticoagulants. However, whether PCM may lead to IS prevention remains equivocal. Patients and methods: In this systematic review and meta-analysis, randomized-controlled clinical trials (RCTs) reporting IS rates among patients with known cardiovascular risk factors, including but not limited to history of IS, who received PCM for more than 7 days versus more conservative cardiac rhythm monitoring methods were pooled. Results: Seven RCTs were included comprising a total of 9048 patients with at least one known cardiovascular risk factor that underwent cardiac rhythm monitoring. PCM was associated with reduction of IS occurrence compared to conventional monitoring (Risk Ratio: 0.76; 95% CI: 0.59-0.96; I 2 = 0%). This association was also significant in the subgroup of RCTs investigating implantable cardiac monitoring (Risk Ratio: 0.75; 95% CI: 0.58-0.97; I 2 = 0%). However, when RCTs assessing PCM in both primary and secondary prevention settings were excluded or when RCTs investigating PCM with a duration of 7 days or less were included, the association between PCM and reduction of IS did not retain its statistical significance. Regarding the secondary outcomes, PCM was related to higher likelihood for AF detection and anticoagulant initiation. No association was documented between PCM and IS/transient ischemic attack occurrence, all-cause mortality, intracranial hemorrhage, or major bleeding. Conclusion: PCM may represent an effective stroke prevention strategy in selected patients. Additional RCTs are warranted to validate the robustness of the reported associations.


Assuntos
Fibrilação Atrial , Ataque Isquêmico Transitório , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/diagnóstico , Ataque Isquêmico Transitório/complicações , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Hemorragia/complicações , AVC Isquêmico/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...