Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev Assoc Med Bras (1992) ; 68(3): 356-361, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35442363

RESUMO

OBJECTIVE: The aim of this study was to evaluate the relationship between the range of motion and lower-limb hemodynamic indices in the tibiotarsal joint of individuals with diabetic neuropathy. METHODS: Twenty volunteers of both sexes, with a mean age of 61.45±7.05 years, were diagnosed with type 2 diabetes mellitus and diabetic peripheral neuropathy. Arterial blood flow was assessed using Doppler ultrasound, and the variables such as average velocity, pulsatility index, and resistivity index were also evaluated. A range of dorsiflexion and plantar flexion joint movements were assessed using digital goniometry before and after exercise. Data distribution was assessed using the Shapiro-Wilk test, followed by Pearson's correlation for normal data and Spearman's correlation for non-normal data, in order to verify the association between variables. RESULTS: A moderate correlation was found between dorsiflexion and pulse rate on two occasions before (rs=0.497) and after initial evaluation (rs=0.511). A low correlation was found between plantar flexion and mean velocity (rs=-0.357), pulsatility index (rs=0.439), and resistivity index (rs=0.328); dorsiflexion and mean velocity (rs=0.374), pulse rate (rs=0.332), and resistance index (rs=0.327) before evaluation, and peak (rs=0.346) was observed after the evaluation of blood circulation. CONCLUSION: There is a correlation between the range of motion of the tibiotarsal joint and the blood circulation of diabetics, ranging from moderate to poor for the different variables evaluated.


Assuntos
Diabetes Mellitus Tipo 2 , Neuropatias Diabéticas , Idoso , Articulação do Tornozelo , Diabetes Mellitus Tipo 2/complicações , Feminino , Humanos , Extremidade Inferior , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular/fisiologia
2.
Rev. Assoc. Med. Bras. (1992, Impr.) ; 68(3): 356-361, Mar. 2022. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1376117

RESUMO

SUMMARY OBJECTIVE: The aim of this study was to evaluate the relationship between the range of motion and lower-limb hemodynamic indices in the tibiotarsal joint of individuals with diabetic neuropathy. METHODS: Twenty volunteers of both sexes, with a mean age of 61.45±7.05 years, were diagnosed with type 2 diabetes mellitus and diabetic peripheral neuropathy. Arterial blood flow was assessed using Doppler ultrasound, and the variables such as average velocity, pulsatility index, and resistivity index were also evaluated. A range of dorsiflexion and plantar flexion joint movements were assessed using digital goniometry before and after exercise. Data distribution was assessed using the Shapiro-Wilk test, followed by Pearson's correlation for normal data and Spearman's correlation for non-normal data, in order to verify the association between variables. RESULTS: A moderate correlation was found between dorsiflexion and pulse rate on two occasions before (rs=0.497) and after initial evaluation (rs=0.511). A low correlation was found between plantar flexion and mean velocity (rs=-0.357), pulsatility index (rs=0.439), and resistivity index (rs=0.328); dorsiflexion and mean velocity (rs=0.374), pulse rate (rs=0.332), and resistance index (rs=0.327) before evaluation, and peak (rs=0.346) was observed after the evaluation of blood circulation. CONCLUSION: There is a correlation between the range of motion of the tibiotarsal joint and the blood circulation of diabetics, ranging from moderate to poor for the different variables evaluated.

3.
Lasers Med Sci ; 36(5): 995-1002, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32862403

RESUMO

Photobiomodulation therapy (PBMT) has been used to improve the physical performance of individuals with advanced age; however, there are no studies in the literature that support the application of light-emitting diode (LED) therapy for the muscular performance of individuals with diabetes mellitus who show a decline in functionality. The aim of the study was to analyze the acute effects of PBMT on strength and functional performance in type 2 diabetic individuals. Sixty-three volunteers were recruited and randomized into five groups: control (C), sham (S), red LED (R), infrared LED (IR), and red LED + infrared LED (R + IR). On the first day, the volunteers were evaluated using the time up and go (TUG), the 6-min walk test (6MWT), and isokinetic dynamometer of the ankle. In the following 3 days, groups R, IR, R + IR, and S returned for application of PBMT bilaterally, with 180 J of energy on each leg. On the fifth day, a reassessment was performed. There was no statistical difference between groups for the variables of the isokinetic dynamometer, TUG, and 6MWT. Analysis of the size of the clinical effect for the isokinetic variables showed that there was no pattern among the effects observed. There is a moderate effect in favor of R, IR, and R + IR in relation to C for the TUG and a moderate effect of R + IR in relation to C for the 6MWT. The PBMT applied for a short period does not bring important gains for the muscular performance and functionality of diabetic individuals.


Assuntos
Diabetes Mellitus/fisiopatologia , Diabetes Mellitus/radioterapia , Terapia com Luz de Baixa Intensidade , Músculos/fisiopatologia , Feminino , Humanos , Masculino , Músculos/efeitos da radiação , Teste de Caminhada
4.
J Med Syst ; 44(4): 88, 2020 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-32166455

RESUMO

INTRODUCTION: Effectiveness of light-emitting diode (LED) in biological tissue is due to the correct application of physical parameters. However, most studies found do not provide complete information on the physical characteristics of the diodes. It is necessary to carefully evaluate the diode parameters so that the results of research with this feature can be reproduced. The objective of this study was to develop a light-emitting device using LED, with proper measurements for application in clinical research. It was used 267 LEDs, powered with 12-V voltage and fixed on a plate of ethylene-vinyl acetate (25 × 42 cm), equidistant at 1.0 cm. For the calculation of red and infrared irradiation, a spectrometer was used, and the data were processed in routines implemented in the OriginPro 8.5.0 SR1 Software. The irradiance was determined by the integration of the spectral irradiation in the LED emission region. The red LED has a wavelength of 620 ± 10 nm, a power density of 52.86 mW/cm2, power of 6.6 mW, and total power of 1.76 W on the device. The infrared LED has a wavelength of 940 ± 10 nm, power density 33.7 mW/cm2, power of 6 mW, and total power of 1.6 W on the device. The LED characterization enables the generation and application of energy with greater precision and reproducibility. Besides, it is a light source, a device capable of framing large areas, reducing the time and cost of the application in different clinical conditions related to neuromuscular performance or rehabilitation.


Assuntos
Desenho de Equipamento , Fototerapia/instrumentação , Humanos , Raios Infravermelhos/uso terapêutico , Reprodutibilidade dos Testes
5.
Lasers Med Sci ; 35(8): 1769-1779, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32078062

RESUMO

Analyze the effects of sequential application of photobiomodulation therapy (PBMT) at different wavelengths on the performance of cycling athletes. Cyclists (48 male, mean age 33.77 years) underwent a performance evaluation through an incremental test, VO2max, blood lactate analysis, perception of effort, infrared thermography, and isokinetic evaluations. Photobiomodulation (180 J) with infrared (IR 940 ± 10 nm), red (RED 620 ± 10 nm), mixed Red, and IR (RED/IR 620 + 940 nm) or Sham (disabled device) intervention occurred on three consecutive days and was applied to the quadriceps femoris bilaterally. Reevaluations were performed 24 h after the last application, with 1 week of follow-up. A significance level of 5% was adopted, and the effect size (ES) was calculated by Cohen's d. Results: There were no significant differences in the analyzed variables under any experimental condition (p > 0.005), but a moderate effect size was observed for torque peak at 60°/s on left lower limb (LLL) (ES = 0.67), average power at 60°/s of the right lower limb (RLL) (0.73), and LLL (ES = 0.65) and a considerable effect size in torque peak at 60°/s of the RLL (ES = 0.98) in the IR/RED group compared with sham 24 h after the last application. Moreover, a large effect size was observed for total time to exhaustion (ES = 1.98) and for VO2max (ES = 6.96), and a moderate effect size was seen for anaerobic threshold (ES = 0.62) in the IR/RED group compared with sham. Photobiomodulation, when not associated with training, was not able to produce a cumulative effect on the performance of cycling athletes. However, the association of two wavelengths seems to be better for increased performance. ClinicalTrials.gov Identifier: NCT03225976.


Assuntos
Desempenho Atlético , Ciclismo/fisiologia , Terapia com Luz de Baixa Intensidade/instrumentação , Adulto , Humanos , Ácido Láctico/sangue , Extremidade Inferior/fisiologia , Extremidade Inferior/efeitos da radiação , Masculino , Consumo de Oxigênio/efeitos da radiação , Torque
6.
J Med Syst ; 42(9): 173, 2018 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-30099597

RESUMO

There is currently little information on the positioning of reference electrode (RE). It is generally accepted that it must be positioned on electrically neutral tissues, such as tendons or bony prominences. The objective of this study is to analyze the characteristics of the electromyographic signal (EMG) for different positions of RE as well as at different levels of muscle contraction. Signals from the brachial biceps and triceps were recorded from 18 healthy women (BMI: 21.20 kg/m2 ± 1.72; mean age: 21.94 ± 1.98 years old) during 100 and 50% maximum flexion voluntary isometric contractions, as well as at rest. For each situation, the RE was randomly positioned in 4 different locations: a) homolateral acromion; b) homolateral brachial biceps; c) styloid process of the contralateral ulna; and d) lateral malleolus of the contralateral ankle. For statistical analysis, Shapiro-Wilk and Kruskal-Wallis tests were used, followed by Dunn's post-hoc test, at a significance level of 5% (p < 0.05). RMS, normalized RMS, PSD, median frequency and levels of energy at 60 Hz, 120 Hz and 180 Hz were assessed for the different sites of RE. The results show that the positioning of the RE on the four experimental locations did not change important features of the electromyographic signals in the time and frequency domains, for the three levels of isometric contractions studied. Such findings compel us to re-think the current trend regarding the RE position followed by the great majority of the researches in areas such as physical therapy.


Assuntos
Eletrodos , Eletromiografia , Contração Muscular , Adulto , Eletromiografia/instrumentação , Eletromiografia/métodos , Feminino , Humanos , Contração Isométrica , Músculo Esquelético , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA