Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 229
Filtrar
1.
J Nat Med ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38564154

RESUMO

Oxomollugin is a degraded product of mollugin and was found to be an active compound that inhibits LPS-induced NF-κB activation. In this study, we investigated the inhibitory activity of oxomollugin, focusing on TLR4 signaling pathway, resulting in NF-κB activation. Oxomollugin inhibited the LPS-induced association of essential factors for initial activation of TLR4 signaling, MyD88, IRAK4 and TRAF6. Furthermore, oxomollugin showed suppressive effects on LPS-induced modification of IRAK1, IRAK2 and TRAF6, LPS-induced association of TRAF6-TAK1/TAB2, and followed by IKKα/ß phosphorylation, which critical in signal transduction leading to LPS-induced NF-κB activation. The consistent results suggested that oxomollugin inhibits LPS-induced NF-κB activation via the suppression against signal transduction in TLR4 signaling pathway.The activities of oxomollugin reported in this study provides a deeper understanding on biological activity of mollugin derivatives as anti-inflammatory compounds.

2.
Yakugaku Zasshi ; 144(4): 347-352, 2024.
Artigo em Japonês | MEDLINE | ID: mdl-38556306

RESUMO

Quantitative NMR (qNMR) is employed to determine the purity of reagents used as standards for HPLC quantification in the Japanese Pharmacopoeia (JP) and has become recognized as a new absolute quantification method in various fields such as pharmaceuticals, foods, and food additives. This report outlines how and why qNMR has been adopted as an official method in the JP and introduces its progression from JP16 to JP18. The results of a survey of companies in the Japan Pharmaceutical Manufacturers' Association regarding how and when to use qNMR from development to manufacturing stages are introduced. The issues involved in the expansion of the use of qNMR in the field of chemical pharmaceuticals in 2017 are discussed and how these were resolved.


Assuntos
Aditivos Alimentares , Japão , Espectroscopia de Ressonância Magnética/métodos , Padrões de Referência , Preparações Farmacêuticas
3.
Chem Pharm Bull (Tokyo) ; 72(1): 36-40, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37899177

RESUMO

The spectrum of 31P-NMR is fundamentally simpler than that of 1H-NMR; consequently identifying the target signal(s) for quantitation is simpler using quantitative 31P-NMR (31P-qNMR) than using quantitative 1H-NMR (1H-qNMR), which has been already established as an absolute determination method. We have previously reported a 31P-qNMR method for the absolute determination of cyclophosphamide hydrate and sofosbuvir as water-soluble and water-insoluble organophosphorus compounds, respectively. This study introduces the purity determination of brigatinib (BR), an organophosphorus compound with limited water solubility, using 31P-qNMR at multiple laboratories. Phosphonoacetic acid (PAA) and 1,4-BTMSB-d4 were selected as the reference standards (RSs) for 31P-qNMR and 1H-qNMR, respectively. The qNMR solvents were chosen based on the solubilities of BR and the RSs for qNMR. CD3OH was selected as the solvent for 31P-qNMR measurements to prevent the influence of deuterium exchange caused by the presence of exchangeable intramolecular protons of BR and PAA on the quantitative values, while CD3OD was the solvent of choice for the 1H-qNMR measurements to prevent the influence of water signals and the exchangeable intramolecular protons of BR and PAA. The mean purity of BR determined by 31P-qNMR was 97.94 ± 0.69%, which was in agreement with that determined by 1H-qNMR (97.26 ± 0.71%), thus indicating the feasibility of purity determination of BR by 31P-qNMR. Therefore, the findings of this study may provide an effective method that is simpler than conventional 1H-qNMR for the determination of organophosphorus compounds.


Assuntos
Compostos Organofosforados , Prótons , Padrões de Referência , Água , Solventes
4.
Yakugaku Zasshi ; 143(11): 951-962, 2023 Nov 01.
Artigo em Japonês | MEDLINE | ID: mdl-37558432

RESUMO

Recently, a novel quantitative method using relative molar sensitivity (RMS) was applied to quantify the ingredients of drugs and foods. An important development in this regard can be observed in the Japanese Pharmacopoeia (JP) 18, where the quantification of perillaldehyde, an unstable compound, in crude drug "Perilla Herb," was revised to incorporate the RMS method. In this study, the primary objective was to improve the tester safety and reduce the amount of reagents used in the JP test. To achieve this, the quantification of three toxic Aconitum monoester alkaloids (AMAs) was explored using the RMS method, employing a single reference compound for all three targets. These AMAs, namely benzoylmesaconine hydrochloride, benzoylhypaconine hydrochloride, and 14-anisoylaconine hydrochloride, which are the quantitative compounds of Kampo extracts containing Aconite Root (AR), were quantified using the reference compound benzoic acid (BA). Reliable RMS values were obtained using both 1H-quantitative NMR and HPLC/UV. Using the RMS of three AMAs relative to the BA, the AMA content (%) in commercial AMAs quantitative reagents were determined without analytical standards. Moreover, the quantitative values of AMAs using the RMS method and the calibration curve method using the three analytical standards were similar. Additionally, similar values were achieved for the three AMAs in the Kampo extracts containing AR using the RMS and the modified JP18 calibration curve methods. These results suggest that the RMS method is suitable for quantitative assays of the Kampo extracts containing AR and can serve as an alternative to the current method specified in the JP18.


Assuntos
Aconitum , Alcaloides , Preparações de Plantas , Aconitum/química , Alcaloides/química , Cromatografia Líquida de Alta Pressão/métodos , Preparações de Plantas/química
5.
Yakugaku Zasshi ; 143(3): 297-307, 2023.
Artigo em Japonês | MEDLINE | ID: mdl-36858562

RESUMO

The Japanese Pharmacopoeia (JP) is an official normative publication for establishing the authenticity and properties and maintaining the quality of pharmaceutical products in Japan. The JP is revised every five years and partially revised in order to respond to the progress of science and technology, the demand for medical care, and international harmonization. Thus, "Internationalization of the JP" is one of the most important issues to address for the revision of the JP, which is also referred to the basic principles for the preparation of the JP 19th edition. For instance, the incorporation of the test methods that have been used in other pharmacopeias, such as the European Pharmacopoeia (EP) and the United States Pharmacopeia (USP), into the JP is one of promising approaches. From this perspective, we have recently reported changes in test methods, establishment of a quantitative test method for the JP-listed clonidine hydrochloride as well as lorazepam from using a potentiometric titration method to using HPLC method. As our ongoing study to change test methods for internationalization, we selected sodium cromoglicate and trihexyphenidyl hydrochloride. Each pharmaceutical product is analyzed using a potentiometric titration method as listed in the 18th JP; however, both the EP and the USP use HPLC method for quantitative analysis of these drugs. In this study, we synthesized the related impurities of sodium cromoglicate and trihexyphenidyl hydrochloride listed in the EP and determined their purities using quantitative NMR. The separation conditions of these compounds were examined using HPLC and simultaneous analyses were performed.


Assuntos
Cromolina Sódica , Triexifenidil , Cromatografia Líquida de Alta Pressão , Clonidina , Cromolina Sódica/normas , Triexifenidil/normas
6.
Microorganisms ; 11(2)2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36838499

RESUMO

We report for the first time that ephedrine alkaloids-free Ephedra Herb extract (EFE) directly inhibits the replication of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in vitro and that the addition of EFE to the culture medium before viral infection reduces virus titers in the culture supernatant of SARS-CoV-2, including those of variant strains, by more than 99%, 24 h after infection. The addition of Ephedra Herb macromolecule condensed-tannin, which is the main active ingredient responsible for the anticancer, pain suppression, and anti-influenza effects of EFE, similarly suppressed virus production in the culture supernatant by 99% before infection and by more than 90% after infection. Since EFE does not have the side effects caused by ephedrine alkaloids, such as hypertension, palpitations, and insomnia, our results showed the potential of EFE as a safe therapeutic agent against coronavirus disease 2019.

7.
Nanomedicine ; 47: 102631, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36410700

RESUMO

High-resolution cryogenic transmission electron microscopy (cryo-TEM) evidenced that doxorubicin sulfate crystals in liposomes (prepared by remote loading with ammonium sulfate) form folded, undulating, and fibrous crystals with a diameter of approximately 2.4 nm. An undulating, fibrous crystal considered to be undergrowth, in addition to bundles of fibrous crystals, was also observed in doxorubicin-loaded liposomes. This explains the validity of the formation of doxorubicin sulfate crystals of various shapes, e.g., curved, U-shaped, or circular, in addition to cylinder and/or rod-like crystals reported in the literature. Liposomes that do not contain crystals have inner aqueous phases with high electron density, suggesting that the doxorubicin is remotely loaded and remains as a solute without precipitation.


Assuntos
Lipossomos , Sulfatos , Doxorrubicina/farmacologia
8.
J Ethnopharmacol ; 301: 115827, 2023 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-36240977

RESUMO

ETHNOPHARMACOLOGICAL RELEVANCE: In our previous study, we reported that Ephedra Herb extract (EHE) increased the locomotor activity of mice in the open-field test and reduced the immobility time in the forced swim test. Ephedrine alkaloids (EAs) are thought to be responsible for the adverse effects of Ephedra Herb. However, there are no reports to verify that the adverse effects of Ephedra Herb are caused by the amount of EAs in the herb. Therefore, we investigated whether these adverse effects of EHE are caused by the amounts of ephedrine (Eph) and pseudoephedrine (Pse) in the herbal extract. In a preliminary study of the time course analysis of the open field test, we newly observed that EHE evoked switching from transient sedation to sustained excitement. AIM OF THE STUDY: We aimed to confirm whether EHE evokes switching from transient sedation to sustained excitement, investigate whether these actions of EHE are caused by the amount of ephedrine (Eph) and pseudoephedrine (Pse) in the herbal extract, and clarify the molecular mechanism of the transient sedative effect. MATERIALS AND METHODS: The locomotor activity of mice was tested using the open-field test. The immobility times were measured using a forced swim test, and the motor dysfunction in mice was tested using the rotarod test. RESULTS: EHE, Eph, and Pse induced transient motionlessness between 0 and 15 min after oral administration, however, they did not induce depression-like behavior and motor dysfunction in mice, suggesting that the motionlessness induced by EHE, Eph, or Pse resulted from sedation. The α2a adrenoceptor inhibitor, atipamezole, decreased their sedative effects. Thus, immediately after EHE administration, the transient sedative effect is mediated through the activation of the α2a adrenoreceptor by Eph and Pse. EHE and Eph increased total locomotor activity for 15-120 min after oral administration; however, Pse had no effect. Therefore, the slow-onset and sustained excitatory effects of EHE are mediated by Eph. CONCLUSIONS: We discovered for the first time that EHE evokes diphasic action by switching from transient sedation to sustained excitement. The transient sedation was evoked by the Eph and Pse in the herbal extract via activation of the α2a adrenoceptor and the sustained excitement was caused by the Eph in the herbal extract.


Assuntos
Alcaloides , Ephedra , Camundongos , Animais , Ephedra/química , Efedrina/farmacologia , Pseudoefedrina , Alcaloides/química , Extratos Vegetais/química , Hipnóticos e Sedativos/farmacologia , Receptores Adrenérgicos
9.
Chem Pharm Bull (Tokyo) ; 70(12): 892-900, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36223954

RESUMO

Quantitative 1H-NMR (1H-qNMR) is useful for determining the absolute purity of organic molecules; however, it is sometimes difficult to identify the target signal(s) for quantitation because of their overlap and complexity. Therefore, we focused on the 31P nucleus because of the simplicity of its signals and previously reported 31P-qNMR in D2O. Here we report 31P-qNMR of an organophosphorus compound, sofosbuvir (SOF), which is soluble in organic solvents. Phosphonoacetic acid (PAA) and 1,4-bis(trimethylsilyl)benzene-d4 (1,4-BTMSB-d4) were used as reference standards for 31P-qNMR and 1H-qNMR, respectively, in methanol-d4. The purity of SOF determined by 31P-qNMR was 100.63 ± 0.95%, whereas that determined by 1H-qNMR was 99.07 ± 0.50%. The average half bandwidths of the 31P signal of PAA and SOF were 3.38 ± 2.39 and 2.22 ± 0.19 Hz, respectively, suggesting that the T2 relaxation time of the PAA signal was shorter than that of SOF and varied among test laboratories. This difference most likely arose from the instability in the chemical shift due to the deuterium exchange of the acidic protons of PAA, which decreased the integrated intensity of the PAA signal. Next, an aprotic solvent, dimethyl sulfoxide-d6 (DMSO-d6), was used as the dissolving solvent with PAA and sodium 4,4-dimethyl-4-silapentanesulfonate-d6 (DSS-d6) as reference standards for 31P-qNMR and 1H-qNMR, respectively. SOF purities determined by 31P-qNMR and 1H-qNMR were 99.10 ± 0.30 and 99.44 ± 0.29%, respectively. SOF purities determined by 31P-qNMR agreed with the established 1H-qNMR values, suggesting that an aprotic solvent is preferable for 31P-qNMR because it is unnecessary to consider the effect of deuterium exchange.


Assuntos
Imageamento por Ressonância Magnética , Sofosbuvir , Deutério , Espectroscopia de Ressonância Magnética , Padrões de Referência , Solventes
10.
Yakugaku Zasshi ; 142(8): 867-874, 2022.
Artigo em Japonês | MEDLINE | ID: mdl-35908947

RESUMO

Particular batches of Moderna mRNA Coronavirus Disease 2019 (COVID-19) vaccine were recalled after foreign particles were found in some vaccine vials at the vaccination site in Japan in August 2021. We investigated the foreign particles at the request of the Ministry of Health, Labour and Welfare. Energy dispersive X-ray spectroscopy analysis suggested that the foreign particles found in the vials recalled from the vaccination sites were from stainless steel SUS 316L, which was in line with the findings of the root cause investigation by the manufacturer. The sizes of the observed particles ranged from <50 µm to 548 µm in the major axis. Similar foreign particles were also detected in 2 of the 5 vaccine vials of the same lot stored by the manufacturer, indicating that the foreign particles have already been administered to some people via vaccine. Observation of the vials of the same lot by digital microscope found smaller particles those were not detected by visual inspection, suggesting that more vials were affected. Contrarily, visual inspection and subvisible particulate matter test indicated no foreign particles in the vials of normal lots. Possible root cause and strategies to prevent such a deviation were discussed from technical and regulatory aspects.


Assuntos
Vacina de mRNA-1273 contra 2019-nCoV , COVID-19 , COVID-19/epidemiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Humanos , Japão/epidemiologia , Material Particulado
11.
J Nat Med ; 76(4): 732-747, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35870047

RESUMO

Foods and pharmaceuticals play key roles in public health and welfare and ensuring that these products meet their quality assurance standards is a top priority in health and medical care. Quality assurance of natural products is essential in pharmaceutical sciences because the outset of a medicine is a natural, crude drug. Regulatory science underpins scientific regulations and is closely related to the quality assurance of foods and pharmaceuticals to ensure their safety and efficacy. During my time at the National Institute of Health Sciences, Japan, from 1986 to present, the regulatory science of natural products has been my main research focus. This review discusses 24 studies related to the regulatory science of natural food additives, 26 related to foods, 23 related to borderline products, 16 related to illicit psychotropic mushrooms, plants, and agents, and 57 related to herbal medicines. In later sections, the regulatory science for ethical Kampo products with new dosage forms and herbal medicines that use Kampo extracts as active pharmaceutical ingredients are discussed. My experience from the early twenty-first century in research projects on the bioequivalence of Kampo products and the development of ephedrine alkaloid-free Ephedra Herb extract demonstrate that regulatory science is crucial for developing new drugs.


Assuntos
Alcaloides , Produtos Biológicos , Plantas Medicinais , Medicina Kampo , Preparações Farmacêuticas
12.
Sci Rep ; 12(1): 10624, 2022 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-35739204

RESUMO

Aerosols or saliva containing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can contaminate living environments, and viruses can be indirectly transmitted. To understand the survival potential of the virus, the viral titers of bovine coronavirus (BCoV), as a model virus, and SARS-CoV-2 were measured on porous and non-porous surfaces. The amount of infectious BCoV recovered remained relatively high on non-porous substrates. However, it quickly decreased on several non-porous surfaces such as nitrile rubber. The time taken to reach the limit of detection on non-woven masks, as a porous substrate, was longer than that of non-porous substrates. On porous substrates other than non-woven masks, the amount of virus recovered quickly decreased, and then remained at a low level. Representative substrates were tested with SARS-CoV-2. The decrease in the amount of infectious virus recovered was similar to that of BCoV, although that of SARS-CoV-2 was more rapid. RNA derived from SARS-CoV-2 was also detected using real-time PCR, and it remained on surfaces much longer than infectious virus, on all substrates. Therefore, it is important to measure the viral titer to avoid the overestimation of infectious virus contamination in the environments. Our results suggest that the surface structure was not directly related to viral survivability.


Assuntos
COVID-19 , Coronavirus Bovino , Aerossóis , Humanos , Máscaras , SARS-CoV-2
13.
Bioanalysis ; 14(6): 325-340, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35234530

RESUMO

Background: With the spread of COVID-19, anti-SARS-CoV-2 antibody tests have been utilized. Herein we evaluated the analytical performance of anti-SARS-CoV-2 antibody test kits using a new reference standard prepared from COVID-19 patient sera. Methods: Fifty-seven kits in total (16 immunochromatography types, 11 ELISA types and 30 types for automated analyzers) were examined. By measuring serially diluted reference standards, the maximum dilution factor showing a positive result and its precision were investigated. Results: The measured cut-off titers varied largely depending on the antibody kit; however, the variability was small, with the titers obtained by each kit being within twofold in most cases. Conclusion: The current results suggest that a suitable kit should be selected depending on the intended purpose.


Assuntos
Teste Sorológico para COVID-19/métodos , Kit de Reagentes para Diagnóstico , Anticorpos Antivirais/sangue , Automação Laboratorial , Teste Sorológico para COVID-19/instrumentação , Teste Sorológico para COVID-19/normas , Ensaio de Imunoadsorção Enzimática/instrumentação , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Imunoglobulina G/sangue , Japão , SARS-CoV-2/imunologia
14.
Anal Chem ; 94(10): 4218-4226, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35238540

RESUMO

The most common diagnostic method used for coronavirus disease-2019 (COVID-19) is real-time reverse transcription polymerase chain reaction (PCR). However, it requires complex and labor-intensive procedures and involves excessive positive results derived from viral debris. We developed a method for the direct detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in nasopharyngeal swabs, which uses matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-ToF MS) to identify specific peptides from the SARS-CoV-2 nucleocapsid phosphoprotein (NP). SARS-CoV-2 viral particles were separated from biological molecules in nasopharyngeal swabs by an ultrafiltration cartridge. Further purification was performed by an anion exchange resin, and purified NP was digested into peptides using trypsin. The peptides from SARS-CoV-2 that were inoculated into nasopharyngeal swabs were detected by MALDI-ToF MS, and the limit of detection was 106.7 viral copies. This value equates to 107.9 viral copies per swab and is approximately equivalent to the viral load of contagious patients. Seven NP-derived peptides were selected as the target molecules for the detection of SARS-CoV-2 in clinical specimens. The method detected between two and seven NP-derived peptides in 19 nasopharyngeal swab specimens from contagious COVID-19 patients. These peptides were not detected in four specimens in which SARS-CoV-2 RNA was not detected by PCR. Mutated NP-derived peptides were found in some specimens, and their patterns of amino acid replacement were estimated by accurate mass. Our results provide evidence that the developed MALDI-ToF MS-based method in a combination of straightforward purification steps and a rapid detection step directly detect SARS-CoV-2-specific peptides in nasopharyngeal swabs and can be a reliable high-throughput diagnostic method for COVID-19.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Lasers , Nasofaringe , RNA Viral/genética , Manejo de Espécimes/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
15.
Yakugaku Zasshi ; 142(1): 65-74, 2022 Jan 01.
Artigo em Japonês | MEDLINE | ID: mdl-34645768

RESUMO

The crystallization of active pharmaceutical ingredients (APIs) in matrix-type transdermal patches has implications for the rate of drug absorption through the skin and patch adhesion strength. Therefore, the presence or absence and the degree of API crystallinity must be controlled to guarantee the quality of patches. In this study, the utility of laboratory-level X-ray diffractometers for the detection and analysis of crystalline APIs in transdermal patches was investigated using medical patches of tulobuterol and isosorbide dinitrate. Several matrix-type patches employ a controlled drug delivery system containing intentionally crystallized API. Both benchtop and high-resolution laboratory X-ray diffractometers can detect several characteristic peaks of the APIs in these patches even if the patches are wrapped in an outer bag, although a benchtop model provides peak heights one-seventh to one-fifth that of a high-resolution instrument. An isosorbide dinitrate patch containing an unintentionally crystallized spot was wrapped in an outer bag, followed by measurements using both X-ray diffractometers. For both instruments, several isosorbide dinitrate-derived peaks were detected only at the crystallized spot, although the signal-to-noise ratio was poorer for the benchtop model. These results show that a high-resolution X-ray diffractometer is advantageous for high-detection sensitivity and offers a high degree of freedom of the measurement position on the sample. It was concluded that a laboratory-level high-resolution X-ray diffractometer can be used to examine the crystalline state of APIs in patches inside an unopened outer bag.


Assuntos
Dinitrato de Isossorbida/análise , Terbutalina/análogos & derivados , Adesivo Transdérmico , Difração de Raios X/métodos , Adesividade , Cristalização , Dinitrato de Isossorbida/química , Pele/metabolismo , Absorção Cutânea , Terbutalina/análise , Terbutalina/química
16.
J Nat Med ; 76(1): 171-177, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34550553

RESUMO

Cliniatines A-C (1-3), three new Amaryllidaceae alkaloids, consisting of 2,6-dimetylpyridine and lycorine-type and/or galanthamine-type were isolated from Clivia miniata (Lindl.) Bosse. The structures and absolute configurations of 1-3 were elucidated based on spectroscopic data and chemical correlation. Cliniatines A-C showed moderate inhibitory activity against acetylcholinesterase.


Assuntos
Alcaloides de Amaryllidaceae , Amaryllidaceae , Acetilcolinesterase , Alcaloides de Amaryllidaceae/farmacologia , Inibidores da Colinesterase/farmacologia , Extratos Vegetais
17.
Chem Pharm Bull (Tokyo) ; 69(9): 872-876, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34470951

RESUMO

N-Nitrosodimethylamine (NDMA) is a probable human carcinogen. This study investigated the root cause of the presence of NDMA in ranitidine hydrochloride. Forced thermal degradation studies of ranitidine hydrochloride and its inherent impurities (Imps. A, B, C, D, E, F, G, H, I, J, and K) listed in the European and United States Pharmacopeias revealed that in addition to ranitidine, Imps. A, C, D, E, H, and I produce NDMA at different rates in a solid or an oily liquid state. The rate of NDMA formation from amorphous Imps. A, C, and E was 100 times higher than that from crystalline ranitidine hydrochloride under forced degradation at 110 °C for 1 h. Surprisingly, crystalline Imp. H, bearing neither the N,N-dialkyl-2-nitroethene-1,1-diamine moiety nor a dimethylamino group, also generated NDMA in the solid state, while Imp. I, as an oily liquid, favorably produced NDMA at moderate temperatures (e.g., 50 °C). Therefore, strict control of the aforementioned specific impurities in ranitidine hydrochloride during manufacturing and storage allows appropriate control of NDMA in ranitidine and its pharmaceutical products. Understanding the pathways of the stability related NDMA formation enables improved control of the pharmaceuticals to mitigate this risk.


Assuntos
Dimetilnitrosamina/síntese química , Ranitidina/química , Dimetilnitrosamina/química , Estrutura Molecular
18.
Yakugaku Zasshi ; 141(7): 961-970, 2021.
Artigo em Japonês | MEDLINE | ID: mdl-34193656

RESUMO

The Japanese Pharmacopoeia (JP) is an official normative publication that is referred to, for establishing the authenticity and properties and maintaining the quality of pharmaceutics in Japan. Partial amendments are periodically made to these guidelines to keep up with the progress of science and technology, and the international harmonization is revised every 5 years. Thus, "Internationalization of the JP" is one of the more important issues to address for the revision of the JP. For example, the incorporation of the test methods that have been used in other pharmacopeias, such as the United States Pharmacopeia (USP) and the European Pharmacopoeia (EP), into the JP is a useful approach. In light of this, we have recently reported changes in test methods in the 17th JP, "Establishment of a quantitative test method for clonidine hydrochloride from using a potentiometric titration method to using HPLC". As a part of our ongoing research to change test methods for internationalization, we selected lorazepam. Lorazepam is analyzed using a potentiometric titration method as listed in the 17th JP; however, both the USP and EP use HPLC for quantitative analysis of this drug. In this study, we synthesized the related impurities of lorazepam listed in the USP and the EP and determined their purities using quantitative NMR. The separation conditions of these compounds, including lorazepam, were examined using HPLC and simultaneous analyses were performed. In addition, lorazepam extracted from the tablets was analyzed using conditions similar to those used for the analysis of the related impurities.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Internacionalidade , Lorazepam/análise , Farmacopeias como Assunto/normas , Psicotrópicos/análise , Japão , Lorazepam/síntese química , Lorazepam/química , Espectroscopia de Ressonância Magnética , Psicotrópicos/síntese química , Psicotrópicos/química
19.
J Pharm Biomed Anal ; 204: 114253, 2021 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-34271287

RESUMO

A simple and rapid on-line SFE/SFC/quadrupole TOF-MS method to simultaneously analyze active pharmaceutical ingredients and impurities from metered-dose inhalers (MDIs) was developed using ciclesonide MDI (CIC-MDI) as an example. CIC-MDI, as drug Alvesco®, has been approved for the treatment of bronchial asthma, and its major impurities are listed in the European Pharmacopoeia and in the supplementary package inserts of Alvesco® (called as "Pharmaceutical interview form" in Japan). In the developed method, CIC-MDI was manually sprayed only once on a glass disc prior to the SFE/SFC/quadrupole TOF-MS. In the SFE, CIC and its impurities and other impurities having various polarities and hydrophobicity, were extracted in 3.5 min and subsequently separated on a CHIRALPAK IE-3 column to be detected by quadrupole TOF-MS in 6.5 min. This method would be applicable to the analysis of other inhalable pharmaceutical products whose sample preparation requires complicated procedures, as well as to the analysis of general pharmaceutical products for profiling impurities.


Assuntos
Cromatografia com Fluido Supercrítico , Administração por Inalação , Espectrometria de Massas , Inaladores Dosimetrados , Pregnenodionas
20.
Int J Pharm ; 605: 120834, 2021 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-34192587

RESUMO

A non-destructive discrimination method for crystals in solid dosage drug forms was first developed using a combination of Raman spectroscopy and X-ray micro-computed tomography (X-ray CT). Identification of the crystal form of an active pharmaceutical ingredient (API) at the appropriate pharmaceutical dosage is crucial, as the crystal form is a determinant of the quality and performance of the final formulation. To develop a non-destructive analytical methodology for the discrimination of solid API crystals in a solid dosage form, we utilized a combination of Raman spectroscopy and X-ray CT to differentiate between ranitidine crystal polymorphs (forms 1 and 2) in tablet formulations containing three excipients. The difference in electron density correlated with the true density between ranitidine polymorphs, thereby enabling the discrimination of crystal forms and visualization of their three-dimensional spatial localization inside the tablets through X-ray CT imaging. Furthermore, X-ray CT imaging revealed that the crystal particles were of varying densities, sizes, and shapes within the same batch. These findings suggest that X-ray CT is not only an imaging tool but also a unique method for quantitative physicochemical characterization to study crystal polymorphs and solid dosage forms.


Assuntos
Ranitidina , Análise Espectral Raman , Cristalização , Formas de Dosagem , Comprimidos , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...