Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cureus ; 14(1): e21519, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35223295

RESUMO

Foreign body aspiration in children is a medical emergency that is associated with significant morbidity and requires medical intervention. The variability of clinical presentations results in delayed diagnosis and treatment. Hence, a high index of clinical suspicion and a thorough examination is needed to expedite the management. We report the case of a toddler girl who aspirated a piece of peanut and was diagnosed as having bronchopneumonia upon presentation with respiratory symptoms for six days. Rigid bronchoscopy was performed and the foreign body was removed successfully without any complications. We aim to highlight the importance of considering the diagnosis of airway foreign body in children with unexplained respiratory distress in our case study.

2.
Cureus ; 11(9): e5737, 2019 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-31723498

RESUMO

A 29-year-old man was brought to the hospital for treatment after an alleged workplace accident. Initial assessment revealed only mild chest injury and mild confusion, with no other injury. His vision was unaffected with no relative afferent pupillary defect. A computed tomography scan of the brain, performed to rule out brain injury, revealed an incidental finding of a foreign body in the left intravitreal cavity with no other significant findings. Further examination of his medical history revealed that he had experienced a trauma one year earlier, in which his left eye was pierced by a projectile. Immediately post-trauma, his vision had been reduced significantly, but improved over the next few weeks without medical treatment. The current examination of his left eye revealed a small hyperpigmented area on the sclera, representing the point of entry of his previous wound. An encapsulated foreign body was observed in the inferior intravitreal cavity, surrounded by retinal atrophy, and a normal posterior pole. He was managed conservatively without complications. The decision to remove a missed retained intraocular foreign body is complex and depends on multiple factors, including surgical difficulty and the composition, size, and location of the retained foreign body. Removal should be weighed against the possible serious complications of intraocular surgery. If removal is surgically difficult, or the retained material is inert, patients can be managed conservatively with regular monitoring.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...