Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 11(22)2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36431244

RESUMO

Early detection of left ventricular systolic dysfunction (LVSD) may prompt early care and improve outcomes for asymptomatic patients. Standard 12-lead ECG may be used to predict LVSD. We aimed to compare the performance of Machine Learning Algorithms (MLA) and physicians in predicting LVSD from a standard 12-lead ECG. By utilizing a dataset of 13,820 pairs of ECGs and echocardiography, a deep residual convolutional neural network was trained for predicting LVSD (ejection fraction (EF) < 50%) from ECG. The ECGs of the test set (n = 850) were assessed for LVSD by the MLA and six physicians. The performance was compared using sensitivity, specificity, and C-statistics. The interobserver agreement between the physicians for the prediction of LVSD was moderate (κ = 0.50), with average sensitivity and specificity of 70%. The C-statistic of the MLA was 0.85. Repeating this analysis with LVSD defined as EF < 35% resulted in an improvement in physicians' average sensitivity to 84% but their specificity decreased to 57%. The MLA C-statistic was 0.88 with this threshold. We conclude that although MLA outperformed physicians in predicting LVSD from standard ECG, prior to robust implementation of MLA in ECG machines, physicians should be encouraged to use this approach as a simple and readily available aid for LVSD screening.

2.
Surg Endosc ; 36(12): 9215-9223, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35941306

RESUMO

BACKGROUND: The potential role and benefits of AI in surgery has yet to be determined. This study is a first step in developing an AI system for minimizing adverse events and improving patient's safety. We developed an Artificial Intelligence (AI) algorithm and evaluated its performance in recognizing surgical phases of laparoscopic cholecystectomy (LC) videos spanning a range of complexities. METHODS: A set of 371 LC videos with various complexity levels and containing adverse events was collected from five hospitals. Two expert surgeons segmented each video into 10 phases including Calot's triangle dissection and clipping and cutting. For each video, adverse events were also annotated when present (major bleeding; gallbladder perforation; major bile leakage; and incidental finding) and complexity level (on a scale of 1-5) was also recorded. The dataset was then split in an 80:20 ratio (294 and 77 videos), stratified by complexity, hospital, and adverse events to train and test the AI model, respectively. The AI-surgeon agreement was then compared to the agreement between surgeons. RESULTS: The mean accuracy of the AI model for surgical phase recognition was 89% [95% CI 87.1%, 90.6%], comparable to the mean inter-annotator agreement of 90% [95% CI 89.4%, 90.5%]. The model's accuracy was inversely associated with procedure complexity, decreasing from 92% (complexity level 1) to 88% (complexity level 3) to 81% (complexity level 5). CONCLUSION: The AI model successfully identified surgical phases in both simple and complex LC procedures. Further validation and system training is warranted to evaluate its potential applications such as to increase patient safety during surgery.


Assuntos
Colecistectomia Laparoscópica , Doenças da Vesícula Biliar , Humanos , Colecistectomia Laparoscópica/métodos , Inteligência Artificial , Doenças da Vesícula Biliar/cirurgia , Dissecação
3.
Gastrointest Endosc ; 94(6): 1099-1109.e10, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34216598

RESUMO

BACKGROUND AND AIMS: Colorectal cancer is a leading cause of death. Colonoscopy is the criterion standard for detection and removal of precancerous lesions and has been shown to reduce mortality. The polyp miss rate during colonoscopies is 22% to 28%. DEEP DEtection of Elusive Polyps (DEEP2) is a new polyp detection system based on deep learning that alerts the operator in real time to the presence and location of polyps. The primary outcome was the performance of DEEP2 on the detection of elusive polyps. METHODS: The DEEP2 system was trained on 3611 hours of colonoscopy videos derived from 2 sources and was validated on a set comprising 1393 hours from a third unrelated source. Ground truth labeling was provided by offline gastroenterologist annotators who were able to watch the video in slow motion and pause and rewind as required. To assess applicability, stability, and user experience and to obtain some preliminary data on performance in a real-life scenario, a preliminary prospective clinical validation study was performed comprising 100 procedures. RESULTS: DEEP2 achieved a sensitivity of 97.1% at 4.6 false alarms per video for all polyps and of 88.5% and 84.9% for polyps in the field of view for less than 5 and 2 seconds, respectively. DEEP2 was able to detect polyps not seen by live real-time endoscopists or offline annotators in an average of .22 polyps per sequence. In the clinical validation study, the system detected an average of .89 additional polyps per procedure. No adverse events occurred. CONCLUSIONS: DEEP2 has a high sensitivity for polyp detection and was effective in increasing the detection of polyps both in colonoscopy videos and in real procedures with a low number of false alarms. (Clinical trial registration number: NCT04693078.).


Assuntos
Pólipos Adenomatosos , Pólipos do Colo , Neoplasias Colorretais , Inteligência Artificial , Pólipos do Colo/diagnóstico , Colonoscopia , Neoplasias Colorretais/diagnóstico , Humanos , Estudos Prospectivos
4.
IEEE Trans Med Imaging ; 39(11): 3451-3462, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32746092

RESUMO

Colonoscopy is tool of choice for preventing Colorectal Cancer, by detecting and removing polyps before they become cancerous. However, colonoscopy is hampered by the fact that endoscopists routinely miss 22-28% of polyps. While some of these missed polyps appear in the endoscopist's field of view, others are missed simply because of substandard coverage of the procedure, i.e. not all of the colon is seen. This paper attempts to rectify the problem of substandard coverage in colonoscopy through the introduction of the C2D2 (Colonoscopy Coverage Deficiency via Depth) algorithm which detects deficient coverage, and can thereby alert the endoscopist to revisit a given area. More specifically, C2D2 consists of two separate algorithms: the first performs depth estimation of the colon given an ordinary RGB video stream; while the second computes coverage given these depth estimates. Rather than compute coverage for the entire colon, our algorithm computes coverage locally, on a segment-by-segment basis; C2D2 can then indicate in real-time whether a particular area of the colon has suffered from deficient coverage, and if so the endoscopist can return to that area. Our coverage algorithm is the first such algorithm to be evaluated in a large-scale way; while our depth estimation technique is the first calibration-free unsupervised method applied to colonoscopies. The C2D2 algorithm achieves state of the art results in the detection of deficient coverage. On synthetic sequences with ground truth, it is 2.4 times more accurate than human experts; while on real sequences, C2D2 achieves a 93.0% agreement with experts.


Assuntos
Neoplasias do Colo , Pólipos do Colo , Algoritmos , Pólipos do Colo/diagnóstico por imagem , Colonoscopia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...