Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
J Arthroplasty ; 34(11): 2652-2662, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31320187

RESUMO

BACKGROUND: In patients requiring both total hip arthroplasty (THA) and lumbar spinal fusion (LSF), consideration of preoperative sagittal spinopelvic measurements can aid in the prediction of postfusion compensatory changes in pelvic tilt (PT) and inform adjustments to traditional THA cup anteversion. This study aims to identify relationships between spinopelvic measurements and post-THA hip instability and to determine if procedure order reveals a difference in hip dislocation rate. METHODS: Patients at a single practice site who received both THA and LSF between 2005 and 2015 (292: 158 = LSF prior to THA, 134 = THA prior to LSF) were retrospectively reviewed for incidents of THA instability. Those with complete radiograph series (89) had their sagittal (standing) spinopelvic profiles measured preoperatively, immediately postoperatively, and 3 months, 6 months, 1 year, 1.5 years, and 2 years postoperatively. Measured parameters included lumbar lordosis (LL), pelvic incidence (PI), PT, and sacral slope (SS). RESULTS: No significant differences in dislocation rates between operative order groups were elicited (7/73 LSF first, 4/62 THA first; Z = 0.664, P = .509). Compared to nondislocators, dislocators had lower LL (-10.9) and SS (-7.8), and higher PT (+4.3) and PI-LL (+7.3). Additional risk factors for dislocation included sacral fusion (relative risk [RR] = 3.0) and revision fusion (RR = 2.7) . Predictive power of the model generated through multiple regression to characterize individual profiles of post-LSF PT compensation based on perioperative measurements was most significant at 1 year (R2 = 0.565, F = 0.000456, P = .028) and 2 years (R2 = 0.741, F = 0.031, P = .001) postoperatively. CONCLUSION: In performing THA after LSF, it is theoretically ideal to proceed with THA at a postfusion interval of at least 1 year, beyond which further compensatory PT change is minimal. However, the order of surgical procedure revealed no statistical difference in hip instability rates. In cases characterized by large PI-LL mismatch (larger or less predictable compensation profiles) or large SS or LL loss (considerably atypical muscle recruitment), consideration of full functional anteversion range between sitting and standing positions to account for abnormalities not appreciated with standing radiographic assessment alone may be warranted.


Assuntos
Artroplastia de Quadril/efeitos adversos , Luxação do Quadril/epidemiologia , Vértebras Lombares/diagnóstico por imagem , Ossos Pélvicos/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Fusão Vertebral , Idoso , Feminino , Luxação do Quadril/etiologia , Humanos , Illinois/epidemiologia , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Postura , Radiografia , Estudos Retrospectivos , Fatores de Risco , Sacro/diagnóstico por imagem
2.
Orthopedics ; 42(5): 294-298, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31185119

RESUMO

The geriatric population represents a rapidly growing segment of society with prolonged life expectancies and more active lifestyles. Many of these patients have already undergone primary total hip arthroplasty (THA) and are presenting with aseptic loosening, polyethylene wear, osteolysis, or periprosthetic fractures. Therefore, the demand for hip revision procedures is expected to grow. Currently, there are many modular implant options available for use in complicated revision THA. Early results of modular femoral revision systems are promising for the treatment of the deficient femur in complex revision THA. The objective of this study was to evaluate component survivorship of a modular femoral revision system in revision THA. A retrospective review was conducted using electronic health records of patients who underwent revision THA performed by 1 of 3 surgeon investigators from 2010 through 2014. The authors included all patients who underwent a revision THA using a specific modular femoral revision system. The authors evaluated component survivorship and time to re-revision THA. Fifty-one revision THAs were included. Seven patients required a second revision THA (13.7%; 95% confidence interval, 4%-23%). Mean time to re-revision THA was 4.88±3.9 months. Kaplan-Meier survivorship using re-revision for any reason was 86.3% at 60 months. This study showed excellent component survivorship of the specific modular femoral revision system in revision THA. [Orthopedics. 2019; 42(5):294-298.].


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/estatística & dados numéricos , Falha de Prótese , Reoperação/instrumentação , Reoperação/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur , Prótese de Quadril/efeitos adversos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Fraturas Periprotéticas/cirurgia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo
3.
Orthopedics ; 42(1): 48-55, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30602046

RESUMO

Thromboembolic events after total joint arthroplasty are potentially devastating complications. This study evaluated the efficacy of 4 different anticoagulants in preventing deep venous thrombosis and pulmonary embolism after total joint arthroplasty. The demographics and anticoagulant use (warfarin, enoxaparin, and aspirin with and without outpatient mechanical pumps) for patients who underwent primary unilateral total joint arthroplasties performed by a single surgeon from January 2013 to October 2014 were retrospectively reviewed. All patients underwent lower extremity ultrasound at the 3-week postoperative visit. A total of 613 primary unilateral total joint arthroplasties met the study inclusion criteria. There were 288 primary total knee arthroplasties and 325 primary total hip arthroplasties. The patients were 62.2% female, having a mean age of 67.6±10.6 years and a mean body mass index of 30.2±5.9 kg/m2. There were 119 patients in group 1 (aspirin alone), 40 patients in group 2 (aspirin plus pumps), 246 patients in group 3 (warfarin), and 208 patients in group 4 (enoxaparin). The overall 3-week symptomatic and asymptomatic deep venous thrombosis and symptomatic pulmonary embolism rates in the entire cohort were 5.7% and 0.3%, respectively. The venous thromboembolism rate was significantly affected by the anticoagulant of choice (P<.01). Compared with aspirin alone, warfarin decreased the risk of venous thromboembolism (P<.01). Increasing age led to increased risk of venous thromboembolism (P=.05). This study indicated that aspirin chemoprophylaxis alone was not as efficacious as warfarin and enoxaparin in preventing asymptomatic and symptomatic venous thromboembolism found during routine postoperative surveillance with lower extremity ultrasound. Aspirin alone may be inadequate and should be augmented with an outpatient mechanical pump as part of multimodal prophylaxis. [Orthopedics. 2019; 42(1):48-55.].


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Aspirina/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Trombose Venosa/prevenção & controle , Idoso , Anticoagulantes/uso terapêutico , Quimioprevenção , Quimioterapia Combinada , Enoxaparina/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos , Trombose Venosa/etiologia , Varfarina/uso terapêutico
4.
J Arthroplasty ; 32(10): 3157-3162, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28634092

RESUMO

BACKGROUND: Reports of implant fracture at the modular junction have been seen in modular neck designs, stem-sleeve modular femoral stems, and diaphyseal engaging bi-body modular stems. To date, however, there has never been a direct comparison between 2 different implant designs from the same modular family. The purpose of this study is to compare the rate of implant failure of 2 such stem-sleeve modular femoral stem designs, the S-ROM and Emperion, to further identify factors which increase the risk of this mode of failure. METHODS: A retrospective, single surgeon, review of our institutional database was performed to compare the 2 groups of patients. RESULTS: A total of 1168 total hip arthroplasty procedures were included in our analysis, 547 (47%) with Emperion and 621 (53%) with S-ROM. Eight (1.5%) fractures in 7 patients occurred in the Emperion group compared to 1 (0.2%) fracture in the S-ROM group (P = .015). CONCLUSION: The precise cause of the stem fractures in our study remains unknown and is likely multifactorial. Given the unexpectedly high rate of catastrophic implant failures in the form of stem fracture at the stem-sleeve junction, we recommend more judicious use of modularity in primary total hip arthroplasty.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/estatística & dados numéricos , Falha de Prótese/etiologia , Idoso , Feminino , Fêmur/cirurgia , Fraturas Ósseas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos
5.
J Arthroplasty ; 31(11): 2408-2414, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27259393

RESUMO

BACKGROUND: Both the prevalence of obesity and the utilization rate of total knee arthroplasty are increasing. The rate and proportion of total knee arthroplasty (TKA) performed in the setting of obesity/morbid obesity is increasing significantly over time. METHODS: Using International Classification of Diseases-Ninth Revision codes, we searched the National Hospitals Discharge Survey national database for patients admitted for primary TKA between 2001 and 2010. We then used International Classification of Diseases-Ninth Revision codes for obesity (body mass index = 30-40 kg/m2) and morbid obesity (body mass index, ≥ 40 kg/m2) to select the obese cohorts. RESULTS: We found 29,694 nonobese, 2645 obese, and 1150 morbidly obese patients. There was an increase in each group over time. The rate of obesity/morbid obesity was strongly correlated with time. Obese and morbidly obese patients were more likely to be younger, female, diabetic, and have Medicaid than nonobese patients. Obese and morbidly obese patients had shorter hospital stays and higher home discharge rates than nonobese patients. Obese and morbidly obese patients had lower transfusion rates, shorter hospital stays, and no increase in inpatient wound infection or venous thromboembolic complications than nonobese patients. The Midwest region saw a greater burden of obese TKA patients. CONCLUSION: With the right measures and precautions, satisfactory inhospital outcomes are possible in the obese patient after primary TKA. A limitation of this study is short inhospital stay of the index procedure as complications may present later after discharge.


Assuntos
Artroplastia do Joelho/estatística & dados numéricos , Obesidade Mórbida/epidemiologia , Idoso , Feminino , Hospitais , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Alta do Paciente , Resultado do Tratamento , Estados Unidos/epidemiologia
6.
Int Orthop ; 40(9): 1787-92, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26728613

RESUMO

PURPOSE: While a majority of total hip arthroplasty (THA) is performed for osteoarthritis (OA), a significant portion is performed in the setting of avascular necrosis (AVN). The purpose of this study is to evaluate recent trends, patient demographics, and in hospital outcomes for primary THA in the setting of AVN in the United States. METHODS: The National Hospital Discharge Survey database was searched for patients admitted to US hospitals after a primary THA for the years 2001-2010. Patients were then separated into two groups by ICD-9 diagnosis codes for OA and AVN. RESULTS: The rates of THA for AVN (r = 0.65) and THA for OA (r = 0.82) both demonstrated a positive correlation with time. The mean patient age of the AVN group was significantly lower (56.9 vs 65.9 years, p < 0.01). Men accounted for 51.9 % of the AVN group and 43.0 % of the OA group (p < 0.01). The AVN group had a significantly higher percentage of African Americans (11.2 % vs 5.4 %, p < 0.01) when compared to the OA group. The AVN group had a higher rate of myocardial infarction (0.3 % vs 0.07 %, p = 0.0163) and a higher average number of medical co-morbidities (5.16 vs 4.77, p < 0.01). CONCLUSIONS: Patients undergoing THA for AVN were more likely to be younger, male, African American, have more medical co-morbidities, and more likely to have a myocardial infarction than those with OA. While the number of primary THAs performed for AVN in the United States has increased over the past ten years, the rate of primary THA for OA increased at a much more rapid rate.


Assuntos
Artroplastia de Quadril , Osteoartrite/cirurgia , Osteonecrose/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Hospitais , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Estados Unidos
7.
Clin Biomech (Bristol, Avon) ; 29(10): 1177-85, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25266242

RESUMO

BACKGROUND: One of the main goals in total hip replacement is to preserve the integrity of the hip kinematics, by well positioning the cup and to make sure its initial stability is congruent and attained. Achieving the latter is not trivial. METHODS: A finite element model of the cup-bone interface simulating a realistic insertion and analysis of different scenarios of cup penetration, insertion, under-reaming and loading is investigated to determine certain measurable factors sensitivity to stress-strain outcome. The insertion force during hammering and its relation to the cup penetration during implantation is also investigated with the goal of determining the initial stability of the acetabular cup during total hip arthroplasty. The mathematical model was run in various configurations to simulate 1 and 2mm of under-reaming at various imposed insertion distances to mimic hammering and insertion of cup insertion into the pelvis. Surface contact and micromotion at the cup-bone interface were evaluated after simulated cup insertion and post-operative loading conditions. FINDINGS: The results suggest a direct correlation between under-reaming and insertion force used to insert the acetabular cup on the micromotion and fixation at the cup-bone interface. INTERPRETATION: While increased under-reaming and insertion force result in an increase amount of stability at the interface, approximately the same percentage of surface contact and micromotion reduction can be achieved with less insertion force. We need to exercise caution to determine the optimal configuration which achieves a good conformity without approaching the yield strength for bone.


Assuntos
Acetábulo , Artroplastia de Quadril/métodos , Prótese de Quadril , Implantação de Prótese/métodos , Acetábulo/fisiologia , Acetábulo/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Modelos Teóricos , Falha de Prótese/etiologia , Estresse Mecânico
8.
Am J Orthop (Belle Mead NJ) ; 43(6): 262-6, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24945475

RESUMO

Performing bilateral total knee arthroplasties (bTKAs), sequential or staged, is a topic of debate among surgeons. To our knowledge, no studies have compared computer-assisted surgery (CAS) and conventional (CON) procedures for sequential bTKAs. We retrospectively reviewed 124 (62 CAS, 62 CON) sequential bTKAs. CAS-bTKAs required significantly fewer blood transfusions (P = .001) and had significantly better postoperative day 1 (POD-1) hemoglobin (Hgb) levels (P = .001) and POD-2 Hgb levels (P = .01). Mean total blood transfusion units were 0.9 for the CAS group and 1.7 for the CON group. Postoperative range of motion, tourniquet time, length of stay, number of readmissions, and number of reoperations were not significantly different (P > .05). The statistically significant differences between the groups may have resulted from violation of the femoral intramedullary canal during the CON technique.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Cirurgia Assistida por Computador , Idoso , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Perioperatório , Estudos Retrospectivos , Cirurgia Assistida por Computador/efeitos adversos , Resultado do Tratamento
10.
J Arthroplasty ; 28(6): 978-84, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23523209

RESUMO

Patella resurfacing in total knee arthroplasty (TKA) reduces postoperative complications and revisions; however, the optimal cutting depth and angle that minimize patellar strain and fracture remain unclear. We performed three-dimensional finite element analysis (FEA) of resurfacing cutting depth and obliquity to assess the stresses in each component of the knee joint, and fatigue testing to determine cyclic loading conditions over the expected life span of the implant. Maximum stress on the patella increased as cutting depth increased up to 8mm; peak stresses on the idealized button further increased at 10-mm depth. Medial superior obliquities below 3° showed the lowest stress on the patella and button and the highest fatigue life. An oblique cut of 3° with respect to the inferior end increased patellar stress and reduced fatigue life, making this the least successful approach. Taken together, our FEA supports the use of minimal cutting depths at -3° with respect to the superior end for patellar resurfacing in TKA in order to minimize stresses in the structure and improve TKA durability. Future studies will assess the effect of patella button placement to account for real-world practice variations.


Assuntos
Artroplastia do Joelho/métodos , Simulação por Computador , Análise de Elementos Finitos , Patela/anatomia & histologia , Patela/cirurgia , Humanos , Estresse Mecânico
11.
J Knee Surg ; 25(1): 45-50, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22624247

RESUMO

Although revision total knee arthroplasty (TKA) procedures are successful in relieving pain and restoring function in failed knees, long-term results are inferior to primary procedures. Mobile bearing (MB) revision knees can potentially improve functional performance. Clinical results of 44 MB rotating platform (RP) revision TKAs demonstrated mean knee injury and osteoarthritis outcome score (KOOS) activity of daily living score of 77 2 years postoperatively. Clinical results were put into context through wear testing which demonstrated improved wear performance compared with fixed bearing (FB) revision knees. The RP construct is a good choice for revision TKA because it permits the surgeon to align the tray for fixation, not compromise rotation of the tibial insert, and reduce transmission of shear stresses to the bone, cement and implant interface, which is a known cause of failure.


Assuntos
Artroplastia do Joelho/métodos , Traumatismos do Joelho/cirurgia , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Desenho de Prótese , Desbridamento , Humanos , Reoperação , Irrigação Terapêutica
12.
Orthopedics ; 34(1): 16, 2011 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-21210627

RESUMO

Interest in mobile-bearing knee prostheses is increasing in the US market. We studied results at 2 to 5 years with a mobile-bearing system that includes a cobalt-chrome tibial tray and femoral component with a polyethylene cruciate-retaining tibial component insert that allows rotation around a central axis and can be used with cruciate-retaining or posterior-stabilized femoral components. The inserts used in this study were cruciate retaining and did not include the posterior-stabilized design. The goal of this study was to demonstrate the function and safety of this prosthesis along with the lack of spinout, which is a major concern in the mobile-bearing knee. Four hundred thirty-five knees constituted the study cohort and underwent survivorship analysis and complication reporting. Routine clinic evaluations included pre- and postoperative radiographs and Knee Society knee and function scores at 6 and 12 weeks and every 2 years. The most recent follow-up data within 2 to 5 years was included for the study along with survey data. Flexion at most recent follow-up averaged 125°. Knee Society score at most recent visit averaged 88 of 100. Knee Society function score averaged 83 of 100. Radiographic results were available for 226 knees, with 97.3% assessed as normal and 6 with these issues: patella stress fracture (3), aseptic tibial loosening (1), patellar osteolysis (1), and patella aseptic loosening (1). In comparison with the fixed-bearing knee equivalent, this mobile-bearing knee demonstrated at least equivalent results in terms of survivorship, function, and patient satisfaction in the short- and mid-term.


Assuntos
Artroplastia do Joelho/instrumentação , Articulação do Joelho/cirurgia , Prótese do Joelho , Desenho de Prótese , Falha de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Materiais Biocompatíveis , Cimentação , Ligas de Cromo , Feminino , Indicadores Básicos de Saúde , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Complicações Pós-Operatórias , Radiografia , Amplitude de Movimento Articular , Resultado do Tratamento
13.
J Arthroplasty ; 26(5): 668-73, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20875943

RESUMO

Because surgeons are electing to perform simultaneous bilateral total knee arthroplasty (TKA), it is important to identify which patients are at increased risk. We performed a retrospective cohort analysis of 150 patients with unilateral TKA vs 150 patients with simultaneous bilateral TKA. The bilateral group demonstrated a 2.1 times greater mean overall complication rate as well as increased transfusion rates. Patients older than 70 years exhibited significantly higher complication rates. Having a preexisting pulmonary disorder in the bilateral cohort carried nearly a 3-fold risk of complications. Patients with body mass indices greater than 30 displayed a complication rate of 0.97 in the bilateral group as opposed to 0.44 in the control group. Our study demonstrated that age, body mass index, and a preexisting pulmonary disorder resulted in increased complications.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Complicações Pós-Operatórias/epidemiologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Transfusão de Sangue/estatística & dados numéricos , Índice de Massa Corporal , Feminino , Seguimentos , Humanos , Pneumopatias/complicações , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
14.
J Arthroplasty ; 25(2): 197-202, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19442483

RESUMO

A significant rim defect encountered during revision surgery can make stable cementless cup fixation difficult. One approach to this problem is to medialize the acetabular cup to improve the degree of rim contact. In this study, we investigate this technique, termed the medial protrusio technique, for acetabular fixation in revision hip arthroplasty. A retrospective review of 25 patients (25 hips) who underwent medialization was performed. Clinical and radiographic evaluation was performed. At an average follow-up of 6.6 years, the overall patient function and satisfaction were good to excellent, with a mean Harris hip score of 85.2. This demonstrates that the medial protrusio technique can be a valuable option in addressing acetabular cup failure.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Osteoartrite do Quadril/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiologia , Prótese de Quadril , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Radiografia , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
15.
Int Orthop ; 33(3): 687-93, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18594821

RESUMO

Femoral rollback after total knee arthroplasty (TKA) is necessary for flexion beyond 90-100 degrees. Femoral rollback in posterior cruciate substituting TKA occurs as a result of the interaction between the femoral cam and tibial post. The geometric design of the cam post mechanism determines the kinematics of rollback. The purpose of this study is to optimise the design of the femoral cam-tibial post articulation through finite element analysis and suggest various design parameters that would optimise femoral rollback. Modifications to the tibial post geometry without changing the relative post position or slope are made. Results are characterised in terms femoral rollback and pressure distribution at the tibial post. Small design modifications to the tibial post are seen to produce large changes in femoral rollback with relatively small accompanying increases in contact pressures at the tibial post.


Assuntos
Artroplastia do Joelho/instrumentação , Análise de Elementos Finitos , Articulação do Joelho/fisiologia , Prótese do Joelho , Desenho de Prótese , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Humanos , Instabilidade Articular/prevenção & controle , Modelos Biológicos , Amplitude de Movimento Articular , Recuperação de Função Fisiológica
16.
J Arthroplasty ; 24(1): 159.e19-24, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18534401

RESUMO

Modular total hip arthroplasty component dissociation has been reported. We describe a case of recurrent instability secondary to femoral stem dissociation from the proximal metaphyseal sleeve and resultant traumatic retroversion of the neck. Femoral stem revision was necessary for treatment of this rare complication.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Fêmur , Prótese de Quadril , Instabilidade Articular/etiologia , Falha de Prótese , Idoso , Feminino , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Instabilidade Articular/diagnóstico , Instabilidade Articular/cirurgia , Radiografia , Reoperação
17.
Orthopedics ; 31(4): 368, 2008 04.
Artigo em Inglês | MEDLINE | ID: mdl-19292281

RESUMO

This study evaluated patient assessments and attitudes regarding incision cosmesis following standard and minimally invasive total hip arthroplasty 1 to 3 years postoperatively. A cosmesis questionnaire designed to elicit a score evaluating scar satisfaction was mailed to patients. Although the difference in total cosmesis score between the standard and minimally invasive groups was not statistically significant, patients with a standard incision had better scores at <1 year. One significant finding was worse responses in the minimal incision patients regarding sinking and curling of scar edges.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Procedimentos Cirúrgicos Minimamente Invasivos/estatística & dados numéricos , Satisfação do Paciente/estatística & dados numéricos , Procedimentos de Cirurgia Plástica/estatística & dados numéricos , Humanos , Illinois/epidemiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...