Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biosensors (Basel) ; 11(10)2021 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-34677355

RESUMO

In this study, we designed and manufactured a series of different microstructure topographical cues for inducing neuronal differentiation of cells in vitro, with different topography, sizes, and structural complexities. We cultured PC12 cells in these microstructure cues and then induced neural differentiation using nerve growth factor (NGF). The pheochromocytoma cell line PC12 is a validated neuronal cell model that is widely used to study neuronal differentiation. Relevant markers of neural differentiation and cytoskeletal F-actin were characterized. Cellular immunofluorescence detection and axon length analysis showed that the differentiation of PC12 cells was significantly different under different isotropic and anisotropic topographic cues. The expression differences of the growth cone marker growth-associated protein 43 (GAP-43) and sympathetic nerve marker tyrosine hydroxylase (TH) genes were also studied in different topographic cues. Our results revealed that the physical environment has an important influence on the differentiation of neuronal cells, and 3D constraints could be used to guide axon extension. In addition, the neurotoxin 6-hydroxydopamine (6-OHDA) was used to detect the differentiation and injury of PC12 cells under different topographic cues. Finally, we discussed the feasibility of combining the topographic cues and the microfluidic chip for neural differentiation research.


Assuntos
Diferenciação Celular , Sinais (Psicologia) , Neurônios , Animais , Células PC12 , Ratos
2.
Lab Chip ; 21(9): 1634-1660, 2021 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-33705507

RESUMO

COVID-19 is an acute respiratory disease caused by SARS-CoV-2, which has high transmissibility. People infected with SARS-CoV-2 can develop symptoms including cough, fever, pneumonia and other complications, which in severe cases could lead to death. In addition, a proportion of people infected with SARS-CoV-2 may be asymptomatic. At present, the primary diagnostic method for COVID-19 is reverse transcription-polymerase chain reaction (RT-PCR), which tests patient samples including nasopharyngeal swabs, sputum and other lower respiratory tract secretions. Other detection methods, e.g., isothermal nucleic acid amplification, CRISPR, immunochromatography, enzyme-linked immunosorbent assay (ELISA) and electrochemical sensors are also in use. As the current testing methods are mostly performed at central hospitals and third-party testing centres, the testing systems used mostly employ large, high-throughput, automated equipment. Given the current situation of the epidemic, point-of-care testing (POCT) is advantageous in terms of its ease of use, greater approachability on the user's end, more timely detection, and comparable accuracy and sensitivity, which could reduce the testing load on central hospitals. POCT is thus conducive to daily epidemic control and achieving early detection and treatment. This paper summarises the latest research advances in POCT-based SARS-CoV-2 detection methods, compares three categories of commercially available products, i.e., nucleic acid tests, immunoassays and novel sensors, and proposes the expectations for the development of POCT-based SARS-CoV-2 detection including greater accessibility, higher sensitivity and lower costs.


Assuntos
COVID-19 , Humanos , Técnicas de Amplificação de Ácido Nucleico , Testes Imediatos , SARS-CoV-2 , Sensibilidade e Especificidade
3.
Biomed Eng Online ; 20(1): 24, 2021 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-33653371

RESUMO

Osteosarcoma (OS) is the most common primary bone malignancy that affects children and young adults. OS is characterized by a high degree of malignancy, strong invasiveness, rapid disease progression, and extremely high mortality rate; it is considered as a serious threat to the human health globally. The incidence of OS is common in the metaphysis of long tubular bones, but rare in the spine, pelvis, and sacrum areas; moreover, majority of the OS patients present with only a single lesion. OS has a bimodal distribution pattern, that is, its incidence peaks in the second decade of life and in late adulthood. We examine historical and current literature to present a succinct review of OS. In this review, we have discussed the types, clinical diagnosis, and modern and future treatment methods of OS. The purpose of this article is to inspire new ideas to develop more effective therapeutic options.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/terapia , Estadiamento de Neoplasias/métodos , Osteossarcoma/diagnóstico por imagem , Osteossarcoma/terapia , Antineoplásicos/farmacologia , Progressão da Doença , Terapia Genética/métodos , Humanos , Imunoterapia/métodos , Imageamento por Ressonância Magnética , Radioterapia/métodos , Tomografia Computadorizada por Raios X
4.
Anal Chem ; 93(2): 1110-1119, 2021 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-33337155

RESUMO

Nondestructive analysis of the single-cell molecular phenotype of circulating tumor cells (CTCs) is of great significance to the precise diagnosis and treatment of cancer but is also a huge challenge. To address this issue, here, we develop a facile analysis system that integrates CTCs' capture and molecular phenotype analysis. An isothermal nucleic acid amplification technique named self-folding induced release reaction (sFiR), which has high-efficiency signal amplification capabilities and can run under physiological conditions, is first developed to meet the high requirements for sensitivity and nondestructivity. By combining the sFiR with immune recognition and a single cell capture microchip, the molecular phenotype analysis of a single CTC is realized. As a model, nondestructive analysis of junction plakoglobin (JUP), an overexpressed membrane protein that is closely related to the metastasis of CTCs, is successfully achieved. Results reveal that this sFiR-based analysis system can clearly distinguish the expression of JUP in different cancer cell lines and can present quantitative information on the expression of JUP. Furthermore, the captured and analyzed CTCs maintain their basic physiological activity and can be used for drug sensitivity testing. Considering the excellent performance and ease of operation of the system, it can provide technical support for CTC-based cancer liquid biopsy and drug development.


Assuntos
Separação Celular , Células Neoplásicas Circulantes/patologia , Análise de Célula Única , gama Catenina/análise , Humanos , Células Tumorais Cultivadas
5.
Biomicrofluidics ; 14(3): 034110, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32509052

RESUMO

Metal-organic frameworks (MOFs) have attracted considerable attention as novel nanoporous materials that combine the properties of organic and inorganic porous materials. HKUST-1 is one of the most well-developed and representative MOFs with wide applications in gas storage and separation, adsorption, and capture. In this study, we used microfluidics, an advanced technique of manipulation of small fluid volumes in microscale or even nanoscale channels, to investigate the effect of sodium dodecyl sulfate (SDS) on the growth of HKUST-1 crystals. We directly observed the morphological evolution of HKUST-1 crystals through droplet arrays with the SDS concentration gradient. The morphology of HKUST-1 evolved from cubic to cuboctahedron and finally to octahedron with increasing SDS concentration. The study results demonstrated the important role played by anions in solution in the structural regulation of HKUST-1.

6.
Biomed Eng Online ; 19(1): 9, 2020 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-32050989

RESUMO

The organ-on-a-chip (OOAC) is in the list of top 10 emerging technologies and refers to a physiological organ biomimetic system built on a microfluidic chip. Through a combination of cell biology, engineering, and biomaterial technology, the microenvironment of the chip simulates that of the organ in terms of tissue interfaces and mechanical stimulation. This reflects the structural and functional characteristics of human tissue and can predict response to an array of stimuli including drug responses and environmental effects. OOAC has broad applications in precision medicine and biological defense strategies. Here, we introduce the concepts of OOAC and review its application to the construction of physiological models, drug development, and toxicology from the perspective of different organs. We further discuss existing challenges and provide future perspectives for its application.


Assuntos
Biomimética/instrumentação , Dispositivos Lab-On-A-Chip , Animais , Humanos
7.
Electrophoresis ; 40(12-13): 1699-1707, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30977901

RESUMO

Point-of-care detection for pathogen is of critical need for wide epidemic warning and medical diagnosis. In this work, we have designed and developed a fully portable and integrated microchip based real-time polymerase chain reaction machine for rapid pathogen detection. The instrument consists of three functional components including heating, optical, and electrical modules, which are integrated into a portable compact box. The microchip is consumable material replaceable to meet various detection needs. Consequently, we demonstrated the outstanding performance of this portable machine for rapid detection of Salmonella and Escherichia coli O157:H7 with the advantage of time-saving (∼25 min), less samples consumption, portability, and user-friendly operation.


Assuntos
DNA Bacteriano , Tipagem Molecular , Testes Imediatos , Reação em Cadeia da Polimerase em Tempo Real , DNA Bacteriano/análise , DNA Bacteriano/genética , DNA Bacteriano/isolamento & purificação , Desenho de Equipamento , Escherichia coli O157/genética , Escherichia coli O157/isolamento & purificação , Células HeLa , Humanos , Tipagem Molecular/instrumentação , Tipagem Molecular/métodos , Reação em Cadeia da Polimerase em Tempo Real/instrumentação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Salmonella/genética , Salmonella/isolamento & purificação
8.
Micromachines (Basel) ; 10(3)2019 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-30909465

RESUMO

The result of molecular diagnostic and detection greatly dependent on the quality and integrity of the isolated nucleic acid. In this work, we developed an automated miniaturized nucleic acid extraction device based on magnetic beads method, consisting of four components including a sample processing disc and its associated rotary power output mechanism, a pipetting module, a magnet module and an external central controller to enable a customizable and automated robust nucleic acid sample preparation. The extracted nucleic acid using 293T cells were verified using real-time polymerase chain reaction (PCR) and the data implies a comparable efficiency to a manual process, with the advantages of performing a flexible, time-saving (~10 min), and simple nucleic acid sample preparation.

9.
Biosens Bioelectron ; 119: 42-47, 2018 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30098465

RESUMO

Protein kinases play a critical role in regulation of intracellular signal transduction, whose aberrant expression is closely associated with various dangerous human diseases. In this paper, we propose a feasible electrochemical assay of intracellular kinase by incorporating peptide nanoprobe-assisted signal labeling and signal amplification. Protein kinase A (PKA)-specific peptide P1 is self-assembled on the surface of a gold electrode, serine of which could be phosphorylated with catalysis of PKA in the presence of adenosine-5'-triphosphate (ATP). Another artificial peptide P2 contains a short template for preparation of copper nanoparticles-based nanoprobe (P2-CuNPs) and provides arginine residues for specific recognition of phosphorylation site. After PKA-catalyzed phosphorylation, phosphorylated P1 specially binds with P2-CuNPs through ultra-stable phosphate-guanidine interaction, and thus results in amplified electrochemical response from surface-attached CuNPs. Our method demonstrates a satisfactory sensitivity toward PKA detection with a detection limit of 0.0019 U/mL, which is also successfully applied in intracellular PKA assay and inhibitory study with high specificity comparable to ELISA. Therefore, the facile method suggests a promising potential use in kinase-related biochemical fundamental research, disease diagnosis and drug discovery in the future.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Eletroquímica , Fosfotransferases/metabolismo , Técnicas Biossensoriais/normas , Eletrodos , Ouro/química , Humanos , Espaço Intracelular/enzimologia , Limite de Detecção , Peptídeos/química , Fosforilação , Reprodutibilidade dos Testes
10.
Genes (Basel) ; 9(6)2018 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-29874840

RESUMO

Recently, microfluidic technologies have attracted an enormous amount of interest as potential new tools for a large range of applications including materials synthesis, chemical and biological detection, drug delivery and screening, point-of-care diagnostics, and in-the-field analysis. Their ability to handle extremely small volumes of fluids is accompanied by additional benefits, most notably, rapid and efficient mass and heat transfer. In addition, reactions performed within microfluidic systems are highly controlled, meaning that many advanced materials, with uniform and bespoke properties, can be synthesized in a direct and rapid manner. In this review, we discuss the utility of microfluidic systems in the synthesis of materials for a variety of biological applications. Such materials include microparticles or microcapsules for drug delivery, nanoscale materials for medicine or cellular assays, and micro- or nanofibers for tissue engineering.

11.
Angew Chem Int Ed Engl ; 56(39): 11885-11890, 2017 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-28767197

RESUMO

As crystallization processes are often rapid, it can be difficult to monitor their growth mechanisms. In this study, we made use of the fact that crystallization proceeds more slowly in small volumes than in bulk solution to investigate the effects of the soluble additives Mg2+ and poly(styrene sulfonate) (PSS) on the early stages of growth of calcite crystals. Using a "Crystal Hotel" microfluidic device to provide well-defined, nanoliter volumes, we observed that calcite crystals form via an amorphous precursor phase. Surprisingly, the first calcite crystals formed are perfect rhombohedra, and the soluble additives have no influence on the morphology until the crystals reach sizes of 0.1-0.5 µm for Mg2+ and 1-2 µm for PSS. The crystals then continue to grow to develop morphologies characteristic of these additives. These results can be rationalized by considering additive binding to kink sites, which is consistent with crystal growth by a classical mechanism.

12.
Adv Mater ; 27(45): 7395-400, 2015 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-26479157

RESUMO

A "crystal hotel" microfluidic device that allows crystal growth in confined volumes to be studied in situ is used to produce large calcite single crystals with predefined crystallographic orientation, microstructure, and shape by control of the detailed physical environment, flow, and surface chemistry. This general approach can be extended to form technologically important, nanopatterned single crystals.


Assuntos
Materiais Biomiméticos/química , Técnicas Analíticas Microfluídicas/métodos , Amônia/química , Carbonato de Cálcio/química , Dióxido de Carbono/química , Cristalização , Dimetilpolisiloxanos/química , Magnésio/química
13.
Anal Chem ; 87(21): 10770-8, 2015 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-26449890

RESUMO

Herein, we describe the development of a multilayer droplet microfluidic system for creating concentration gradients and generating microdroplets of varying composition for high-throughput biochemical and cell-based screening applications. The 3D droplet-based microfluidic device consists of multiple PDMS layers, which are used to generate logarithmic concentration gradient reagent profiles. Parallel flow focusing structures are used to form picoliter-sized droplets of defined volumes but of varying composition. As proof of concept, we demonstrate rapid enzymatic activity assays and drug cytotoxicity assays on bacteria. The 3D droplet-based microfluidic platform has the potential to allow for high-efficiency and high-throughput analysis, overcoming the structural limitations of single layer microfluidic systems.


Assuntos
Técnicas de Química Analítica/métodos , Técnicas Analíticas Microfluídicas , Antibacterianos/química , Antibacterianos/farmacologia , Bactérias/efeitos dos fármacos , Bactérias/enzimologia , Caspase 3/química , Caspase 3/metabolismo , Sobrevivência Celular/efeitos dos fármacos , Cinética
14.
Int J Clin Exp Med ; 8(3): 4501-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26064375

RESUMO

A certain proportion of patients with initial Percutaneous nephrolithotripsy (PCNL) management require ancillary procedures to increase the stone-free rate. In this study, we aim to analyze the efficacy and safety of flexible ureteroscopy combined with holmium laser lithotripsy (F-UL) for treatment of residual calculi after PCNL by comparison with extracorporeal shockwave lithotripsy (SWL). Total of 96 patients with residual renal calculi (4 mm to 20 mm) after PCNL was enrolled from May 2010 to March 2013. They were randomly divided into two groups: US Group: patients were treated with F-UL; SWL Group: patients were treated with SWL. Follow-up was made one month and three months after treatment. The mean residual stone size after PCNL was 12.4 ± 4.3 mm in US group compared with 11.9 ± 4.5 in SWL group. The stone-free rate was 84.7% one month after surgical procedure in US group, this rate increased to 91.3% in the third months, while the stone-free rate in SWL group is 64.6% one month after treatment and 72.9% in the third month. For residual stone in lower calyx, the stone-free rate three month after treatment was 90.4% in US group compared to 65.2% in SWL group (P < 0.05). The overall complication rate was low in both groups, no severe complication was found. Both F-UL and SWL are safe and effective methods for residual calculi after PCNL, without severe complications. F-UL provided significantly higher stone-free rate compared with SWL, especially for low-pole calculi.

15.
Anal Chem ; 86(1): 835-41, 2014 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-24328180

RESUMO

With the view of enhancing the functionality of label-free single molecule nanopore-based detection, we have designed and developed a highly robust, mechanically stable, integrated nanopipette-microfluidic device which combines the recognized advantages of microfluidic systems and the unique properties/advantages of nanopipettes. Unlike more typical planar solid-state nanopores, which have inherent geometrical constraints, nanopipettes can be easily positioned at any point within a microfluidic channel. This is highly advantageous, especially when taking into account fluid flow properties. We show that we are able to detect and discriminate between DNA molecules of varying lengths when motivated through a microfluidic channel, upon the application of appropriate voltage bias across the nanopipette. The effects of applied voltage and volumetric flow rates have been studied to ascertain translocation event frequency and capture rate. Additionally, by exploiting the advantages associated with microfluidic systems (such as flow control and concomitant control over analyte concentration/presence), we show that the technology offers a new opportunity for single molecule detection and recognition in microfluidic devices.


Assuntos
DNA/análise , Vidro/química , Técnicas Analíticas Microfluídicas/métodos , Nanotecnologia/métodos , Nanotecnologia/instrumentação
17.
Top Curr Chem ; 304: 91-115, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21528441

RESUMO

Microfluidics is a low-cost technique for fast-diagnosis and microsynthesis. Within a decade it might become the foundation of point-of-care and lab-on-a-chip applications. With microfluidic chips, high-throughput sample screening and information processing are made possible. The picoliter droplet runs in microfluidic chips are ideal miniaturized vessels for microdetection and microsynthesis. Meanwhile, individual manipulation of microdroplets remains a challenge: the shortcomings in automatic, reliable, and scalable methods for logic control prevent further integration of microfluidic applications. The giant electrorheological fluid (GERF), which is a kind of "smart" colloid, has tunable viscosity under the influence of external electric field. Therefore, GERF is introduced as the active controlling medium, with real-time response in on-chip fluid control. This review article introduces the working principles and fabrication methods of different types of electrorheological fluid, and extensively describes the strategies of GERF-assisted microfluidic controlling schemes.


Assuntos
Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Microfluídica/instrumentação , Microfluídica/métodos , Modelos Teóricos
18.
Biomicrofluidics ; 4(3)2010 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-20890452

RESUMO

We report a simple, low-cost, rapid, and mask-free method to fabricate two-dimensional (2D) and three-dimensional (3D) microfluidic chip for biological analysis researches. In this fabrication process, a laser system is used to cut through paper to form intricate patterns and differently configured channels for specific purposes. Bonded with cyanoacrylate-based resin, the prepared paper sheet is sandwiched between glass slides (hydrophilic) or polymer-based plates (hydrophobic) to obtain a multilayer structure. In order to examine the chip's biocompatibility and applicability, protein concentration was measured while DNA capillary electrophoresis was carried out, and both of them show positive results. With the utilization of direct laser cutting and one-step gas-sacrificing techniques, the whole fabrication processes for complicated 2D and 3D microfluidic devices are shorten into several minutes which make it a good alternative of poly(dimethylsiloxane) microfluidic chips used in biological analysis researches.

19.
Lab Chip ; 10(21): 2869-74, 2010 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-20882229

RESUMO

We report the successful realization of a microfluidic chip with switching and corresponding inverting functionalities. The chips are identical logic control components incorporating a type of smart colloid, giant electrorheological fluid (GERF), which possesses reversible characteristics via a liquid-solid phase transition under external electric field. Two pairs of electrodes embedded on the sides of two microfluidic channels serve as signal input and output, respectively. One, located in the GERF micro-channel is used to control the flow status of GERF, while another one in the ither micro-fluidic channel is used to detect the signal generated with a passing-by droplet (defined as a signal droplet). Switching of the GERF from the suspended state (off-state) to the flowing state (on-state) or vice versa in the micro-channel is controlled by the appearance of signal droplets whenever they pass through the detection electrode. The output on-off signals can be easily demonstrated, clearly matching with GERF flow status. Our results show that such a logic switch is also a logic IF gate, while its inverter functions as a NOT gate.

20.
Lab Chip ; 10(19): 2622-7, 2010 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-20689865

RESUMO

We report a simple, low-cost and detachable microfluidic chip incorporating easily accessible paper, glass slides or other polymer films as the chip materials along with adhesive wax as the recycling bonding material. We use a laser to cut through the paper or film to form patterns and then sandwich the paper and film between glass sheets or polymer membranes. The hot-melt adhesive wax can realize bridge bonding between various materials, for example, paper, polymethylmethacrylate (PMMA) film, glass sheets, or metal plate. The bonding process is reversible and the wax is reusable through a melting and cooling process. With this process, a three-dimensional (3D) microfluidic chip is achievable by vacuating and venting the chip in a hot-water bath. To study the biocompatibility and applicability of the wax-based microfluidic chip, we tested the PCR compatibility with the chip materials first. Then we applied the wax-paper based microfluidic chip to HeLa cell electroporation (EP). Subsequently, a prototype of a 5-layer 3D chip was fabricated by multilayer wax bonding. To check the sealing ability and the durability of the chip, green fluorescence protein (GFP) recombinant Escherichia coli (E. coli) bacteria were cultured, with which the chemotaxis of E. coli was studied in order to determine the influence of antibiotic ciprofloxacin concentration on the E. coli migration.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Papel , Ceras/química , Adesividade , Desenho de Equipamento , Análise de Falha de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...