Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Prosthodont ; 28(3): 252-257, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30637850

RESUMO

PURPOSE: To identify associations between implant failure and selective serotonin reuptake inhibitor (SSRI) medication use in a cohort of consecutive patients receiving dental implants during a 20-year period. MATERIALS AND METHODS: A retrospective review was conducted of all patients who received at least 1 dental implant from January 1, 1995, through December 31, 2014, assessing their history of SSRI use, active SSRI use, and SSRI use during follow-up with implant failure. Cox proportional hazards regression models assessed associations between demographic characteristics and SSRI use with implant failure, and outcomes were summarized with hazard ratios (HRs) and 95% confidence intervals (CIs). Follow-up SSRI use was analyzed with time-dependent covariates. RESULTS: During the study period, 5456 patients received their first implant (median age, 53 years). The median duration of follow-up was 5.3 years (interquartile range, 2.3-10.2 years) for the 4927 patients who did not have implant failure. For the 529 patients who had implant failure, it occurred at a median of 0.5 years. After adjusting for age, sex, and era of implant, history of use of the SSRI sertraline was associated with an increased risk of implant failure among all patients (hazard ratio [HR], 1.60; 95% CI, 1.15-2.23; p = 0.006) and among the subset of patients with a history of SSRI use (HR, 1.64; 95% CI, 1.07-2.52; p = 0.02). CONCLUSIONS: In the population reviewed, a history of sertraline use was associated with a 60% greater risk of implant failure; however, active SSRI use at the time of implant placement or during follow-up was not significantly associated with an increased risk of implant failure.


Assuntos
Implantes Dentários , Inibidores Seletivos de Recaptação de Serotonina , Estudos de Coortes , Humanos , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco
2.
J Prosthodont ; 28(6): 623-633, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30350385

RESUMO

PURPOSE: Systematic monitoring of important clinical outcomes is increasingly important for health-care decision making, especially in the context of continuous quality improvement. Dental implant failure within the first year (early failure) has been previously shown to be more common than subsequent failure. The purpose of this study was to identify associations between early implant failure and patient factors, surgical manipulations, and systemic conditions. MATERIALS AND METHODS: The authors retrospectively identified the records of consecutive adult patients with dental implants seen between 2000 and 2014 in the Department of Dental Specialties, at the Mayo Clinic. Demographic, surgical, and medical data were extracted from the database and individual medical records to determine time to first implant failure. Cox proportional hazards regression models were used to assess associations of demographic, surgical, and systemic conditions with implant failure during the first year post-implantation, summarized as hazard ratio (HR) (95% confidence interval [CI]). RESULTS: Among 8540 implants identified during the study period, 362 (4.2%) failed within the first year of placement at a mean (SD) of 129 (96) days after placement. On univariate analysis, most candidate predictors were not shown to influence first-year failure. Preplacement surgical manipulations associated with increased early implant failure were bone augmentation only (HR, 1.45; 95% CI, 1.02-2.05; p = 0.04), socket preservation (HR, 2.67; 95% CI, 1.33-5.38; p = 0.006), and xenogenic material (HR, 2.12; 95% CI, 1.11-4.04; p = 0.02). Alveoloplasty only at placement was associated with decreased early implant failure (HR, 0.33; 95% CI, 0.17-0.65; p = 0.001). Overall, 318 implants (3.7%) had surgical complications within the first year of placement at a mean (SD) of 110 (114) days after placement; any surgical complication was significantly associated with early implant failure (hazard ratio, 15.84; 95% CI, 11.10-22.61; p < 0.001). After adjustment for age, sex, and implant era, no single or multiple medical condition(s) and no single or multiple medication(s) increased patient risk of implant failure in the first year after placement. CONCLUSIONS: These findings support a targeted effort to reduce the incidence of surgical complications to reduce early failure of dental implants.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Adulto , Falha de Restauração Dentária , Humanos , Modelos de Riscos Proporcionais , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...