Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AAPS PharmSciTech ; 25(3): 45, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38396188

RESUMO

In this study, dry dispersion laser diffraction was used to study the dispersibility of spheronized agglomerate formulations and identify geometric particle size metrics that correlated well with aerodynamic particle size distribution (APSD). Eleven unique batches of agglomerates were prepared for both laser diffraction and cascade impaction testing. Correlations between the particle size distribution (PSD) and aerodynamic particle size distribution (APSD) metrics for the eleven agglomerate batches were determined in a semi-empirical manner. The strongest correlation between APSD and PSD was observed between the impactor-sized mass (%ISM) and the cumulative PSD fraction <14.5 µm. The strongest correlation with fine particle fraction (FPF) was observed with the cumulative PSD fraction <0.99 micron (R-squared = 0.974). In contrast to the other APSD metrics, good correlations were not found between the mass median aerodynamic diameter (MMAD) and the cumulative PSD fractions. Overall, the implementation of laser diffraction as a surrogate for cascade impaction has the potential to streamline product development. Laser diffraction measurements offer savings in labor and turnaround time compared to cascade impaction.


Assuntos
Inaladores de Pó Seco , Lasers , Aerossóis , Composição de Medicamentos , Tamanho da Partícula , Administração por Inalação , Pós
2.
AAPS PharmSciTech ; 24(7): 208, 2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37817001

RESUMO

Although nasal inhalation products are becoming more and more important for the delivery of medicines, characterization of these products for quality control and assessment of bioequivalence is complicated. Most of the problems encountered are associated with the assessment of aerodynamic droplet/particle size distribution (APSD). The droplets produced by the various nasal devices are large, and for suspension products, individual droplets may contain multiple drug particles or none at all. Assessment of suspension products is further complicated by the presence of solid excipient particles. These complications make it imperative that the limitations of the instruments used for characterization as well as the underlying assumptions that govern the interpretation of data produced by these instruments are understood. In this paper, we describe various methodologies used to assess APSD for nasal inhalation products and discuss proper use, limitations, and new methodologies on the horizon.


Assuntos
Inaladores Dosimetrados , Tamanho da Partícula , Aerossóis , Administração por Inalação , Suspensões
3.
J Acquir Immune Defic Syndr ; 92(4): 310-316, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36450129

RESUMO

BACKGROUND: Islatravir (MK-8591) is a deoxyadenosine analog in development for the treatment and prevention of HIV-1 infection. An islatravir-eluting implant could provide an additional option for pre-exposure prophylaxis (PrEP). SETTING: Previous data support a threshold islatravir triphosphate concentration for PrEP of 0.05 pmol/10 6 cells in peripheral blood mononuclear cells. Prototype islatravir-eluting implants were previously studied to establish general tolerability and pharmacokinetics (PKs) of islatravir relative to the threshold level. METHODS: In this randomized, double-blind, placebo-controlled, phase 1 trial, a next-generation radiopaque islatravir-eluting implant (48 mg, 52 mg, or 56 mg) or placebo implant was placed for a duration of 12 weeks in participants at low risk of HIV infection. Safety and tolerability, as well as PK for islatravir parent and islatravir triphosphate from plasma and peripheral blood mononuclear cells, were assessed throughout placement and 8 weeks after removal. RESULTS: In total, 36 participants (8 active and 4 placebo per dose arm) were enrolled and completed this study. Implants were generally well tolerated, with no discontinuations due to an adverse event, and no clear dose-dependence in implant-related adverse events. No clinically meaningful relationships were observed for changes in laboratory values, vital signs, or electrocardiogram assessments. Mean islatravir triphosphate levels at day 85 (0.101-0.561 pmol/10 6  cells) were above the PK threshold for all dose levels. CONCLUSION: Islatravir administered using a subdermal implant has the potential to be an effective and well-tolerated method for administering PrEP to individuals at risk of acquiring HIV-1.


Assuntos
Infecções por HIV , HIV-1 , Profilaxia Pré-Exposição , Humanos , Infecções por HIV/tratamento farmacológico , Profilaxia Pré-Exposição/métodos , Leucócitos Mononucleares , Desoxiadenosinas/uso terapêutico , Método Duplo-Cego
4.
Nat Med ; 27(10): 1712-1717, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34608329

RESUMO

Islatravir (MK-8591) is a highly potent type 1 human immunodeficiency virus (HIV-1) nucleoside reverse transcriptase translocation inhibitor with a long intracellular half-life that is in development for the prevention and treatment of HIV-1. We conducted a randomized, double-blind, placebo-controlled, phase 1 trial in adults without HIV-1 infection. Participants received islatravir or placebo subdermal implants for 12 weeks and were monitored throughout this period and after implant removal. The co-primary end points were safety and tolerability of the islatravir implant and pharmacokinetics, including concentration at day 85, of islatravir triphosphate in peripheral blood mononuclear cells (PBMCs). Secondary end points included additional pharmacokinetic parameters for islatravir triphosphate in PBMCs and the plasma pharmacokinetic profile of islatravir. Based on preclinical data, two doses were assessed: 54 mg (n = 8, two placebo) and 62 mg (n = 8, two placebo). The most frequently reported adverse events were mild-to-moderate implant-site reactions (induration, hematoma, pain). Throughout the 12-week trial, geometric mean islatravir triphosphate concentrations were above a pharmacokinetic threshold of 0.05 pmol per 106 PBMCs, which was estimated to provide therapeutic reverse transcriptase inhibition (concentration at day 85 (percentage of geometric coefficient of variation): 54 mg, 0.135 pmol per 106 cells (27.3); 62 mg, 0.272 pmol per 106 cells (45.2)). Islatravir implants at both doses were safe and resulted in mean concentrations above the pharmacokinetic threshold through 12 weeks, warranting further investigation of islatravir implants as a potential HIV prevention strategy.


Assuntos
Fármacos Anti-HIV/administração & dosagem , Desoxiadenosinas/administração & dosagem , Infecções por HIV/tratamento farmacológico , Inibidores da Transcriptase Reversa/administração & dosagem , Adulto , Fármacos Anti-HIV/efeitos adversos , Fármacos Anti-HIV/farmacocinética , Desoxiadenosinas/efeitos adversos , Desoxiadenosinas/farmacocinética , Método Duplo-Cego , Infecções por HIV/genética , Infecções por HIV/virologia , Transcriptase Reversa do HIV/antagonistas & inibidores , HIV-1/efeitos dos fármacos , HIV-1/patogenicidade , Humanos , Leucócitos Mononucleares/efeitos dos fármacos , Masculino , Pessoa de Meia-Idade , Placebos , Inibidores da Transcriptase Reversa/efeitos adversos , Inibidores da Transcriptase Reversa/farmacocinética , Replicação Viral/efeitos dos fármacos
5.
AAPS PharmSciTech ; 21(7): 239, 2020 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-32827121

RESUMO

Multi-stage cascade impactors (CI) are accepted for the determination of metrics of the drug mass aerodynamic particle size distributions (APSD) of aerosols emitted from orally inhaled products (OIPs). This is particularly important for products where the drug to excipient ratio or particle density may not be the same in each aerodynamic size fraction; examples of such products are carrier-containing dry powder inhalers (DPIs) and suspension pressurized metered-dose inhalers (pMDIs). CI measurements have been used as the "gold standard" for acceptance of alternative methods of APSD assessment, such as laser diffraction for nebulized solutions. Although these apparatus are labor-intensive, they are accepted in regulatory submissions and quality control assessments because the mass of active pharmaceutical ingredient(s) in the aerosol can be quantified by chemical assay and measured particle size is based on the aerodynamic diameter scale that is predictive of deposition in the respiratory tract. Two of the most important factors that modify the ideal operation of an impactor are "particle bounce," that is often accompanied by re-entrainment in the air flow passing the stage of interest, and electrostatic charge acquired by the particles during the preparation and aerosolization of the formulation when the inhaler is actuated. This article reviews how both factors can lead to biased APSD measurements, focusing on measurements involving pMDIs and DPIs, where these sources of error are most likely to be encountered. Recommendations are provided for the mitigation of both factors to assist the practitioner of these measurements.


Assuntos
Tamanho da Partícula , Eletricidade Estática , Tecnologia Farmacêutica/métodos , Administração por Inalação , Desenho de Equipamento , Humanos , Inaladores Dosimetrados , Controle de Qualidade , Medicamentos para o Sistema Respiratório
6.
AAPS PharmSciTech ; 20(5): 206, 2019 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-31147791

RESUMO

The multi-stage cascade impactor (CI) is the mainstay method for the determination of the aerodynamic particle size distribution (APSD) of aerosols emitted from orally inhaled products (OIPs). CIs are designed to operate at a constant flow rate throughout the measurement process. However, it is necessary to mimic an inhalation maneuver to disperse the powder into an aerosol when testing passive dry powder inhalers (DPIs), which constitute a significant portion of available products in this inhaler class. Methods in the pharmacopeial compendia intended for product quality assurance initiate sampling by applying a vacuum to the measurement apparatus using a timer-operated solenoid valve located downstream of the CI, resulting in a period when the flow rate through the impactor rapidly increases from zero towards the target flow rate. This article provides recommendations for achieving consistent APSD measurements, including selection of the CI, pre-separator, and flow control equipment, as well as reviewing considerations that relate to the shape of the flow rate-sampling time profile. Evidence from comparisons of different DPIs delivering the same active pharmaceutical ingredients (APIs) is indicative that the compendial method for APSD measurement is insensitive as a predictor of pharmacokinetic outcomes. Although inappropriate for product quality testing, guidance is therefore provided towards adopting a more clinically realistic methodology, including the use of an anatomically appropriate inlet and mimicking patient inhalation at the DPI while operating the CI at constant flow rate. Many of these recommendations are applicable to the testing of other OIP classes.


Assuntos
Aerossóis/normas , Inaladores de Pó Seco/métodos , Desenho de Equipamento/métodos , Tamanho da Partícula , Controle de Qualidade , Administração por Inalação , Aerossóis/administração & dosagem , Aerossóis/química , Inaladores de Pó Seco/instrumentação , Desenho de Equipamento/instrumentação , Humanos , Pós , Medicamentos para o Sistema Respiratório/administração & dosagem , Medicamentos para o Sistema Respiratório/química , Medicamentos para o Sistema Respiratório/normas , Tecnologia Farmacêutica/métodos
7.
AAPS PharmSciTech ; 18(8): 3296-3306, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28589305

RESUMO

This article reports on results from a two-lab, multiple impactor experiment evaluating the abbreviated impactor measurement (AIM) concept, conducted by the Cascade Impaction Working Group of the International Pharmaceutical Aerosol Consortium on Regulation and Science (IPAC-RS). The goal of this experiment was to expand understanding of the performance of an AIM-type apparatus based on the Andersen eight-stage non-viable cascade impactor (ACI) for the assessment of inhalation aerosols and sprays, compared with the full-resolution version of that impactor described in the pharmacopeial compendia. The experiment was conducted at two centers with a representative commercially available pressurized metered dose inhaler (pMDI) containing albuterol (salbutamol) as active pharmaceutical ingredient (API). Metrics of interest were total mass (TM) emitted from the inhaler, impactor-sized mass (ISM), as well as the ratio of large particle mass (LPM) to small particle mass (SPM). ISM and the LPM/SPM ratio together comprise the efficient data analysis (EDA) metrics. The results of the comparison demonstrated that in this study, the AIM approach had adequate discrimination to detect changes in the mass median aerodynamic diameter (MMAD) of the ACI-sampled aerodynamic particle size distribution (APSD), and therefore could be employed for routine product quality control (QC). As with any test method considered for inclusion in a regulatory filing, the transition from an ACI (used in development) to an appropriate AIM/EDA methodology (used in QC) should be evaluated and supported by data on a product-by-product basis.


Assuntos
Albuterol/análise , Inaladores Dosimetrados/normas , Tamanho da Partícula , Tecnologia Farmacêutica/métodos , Tecnologia Farmacêutica/normas , Administração por Inalação , Aerossóis , Albuterol/química , Broncodilatadores/análise , Broncodilatadores/química , Desenho de Equipamento/métodos , Desenho de Equipamento/normas , Inaladores Dosimetrados/tendências , Nebulizadores e Vaporizadores/normas , Nebulizadores e Vaporizadores/tendências , Controle de Qualidade
8.
AAPS PharmSciTech ; 18(2): 451-461, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27068528

RESUMO

The performance of two quality control (QC) tests for aerodynamic particle size distributions (APSD) of orally inhaled drug products (OIPs) is compared. One of the tests is based on the fine particle dose (FPD) metric currently expected by the European regulators. The other test, called efficient data analysis (EDA), uses the ratio of large particle mass to small particle mass (LPM/SPM), along with impactor sized mass (ISM), to detect changes in APSD for QC purposes. The comparison is based on analysis of APSD data from four products (two different pressurized metered dose inhalers (MDIs) and two dry powder inhalers (DPIs)). It is demonstrated that in each case, EDA is able to detect shifts and abnormalities that FPD misses. The lack of sensitivity on the part of FPD is due to its "aggregate" nature, since FPD is a univariate measure of all particles less than about 5 µm aerodynamic diameter, and shifts or changes within the range encompassed by this metric may go undetected. EDA is thus shown to be superior to FPD for routine control of OIP quality. This finding augments previously reported superiority of EDA compared with impactor stage groupings (favored by US regulators) for incorrect rejections (type I errors) when incorrect acceptances (type II errors) were adjusted to the same probability for both approaches. EDA is therefore proposed as a method of choice for routine quality control of OIPs in both European and US regulatory environments.


Assuntos
Aerossóis/química , Inaladores de Pó Seco/métodos , Teste de Materiais/métodos , Pós/química , Estatística como Assunto/métodos , Tecnologia Farmacêutica/métodos , Administração por Inalação , Administração Oral , Inaladores Dosimetrados , Tamanho da Partícula , Controle de Qualidade
9.
Pharm Res ; 33(8): 1936-44, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27194003

RESUMO

PURPOSE: To probe the suitability of a dry-powder oxytocin formulation containing a carrier (µco™; SNBL, Ltd.) for intranasal (IN) administration to treat post-partum hemorrhage in the developing world. Specifically, to investigate (1) whether IN administration can achieve rapid systemic absorption in cynomolgus monkeys, and (2) whether the formulation exhibits sufficient physical and chemical stability. This study was conducted to support Merck for Mothers, Merck's 10-year global initiative to end preventable maternal deaths. METHODS: A partial-crossover pharmacokinetic (PK) study in cynomolgus monkeys (n = 6) was utilized to compare in vivo absorption of dry-powder IN oxytocin at three dose levels against an IM injection of an aqueous oxytocin formulation. Particle size distribution, delivered dose and chemical assay were monitored over a 12 month stability study. RESULTS: IN administration of oxytocin resulted in short (5 min) Tmax and good dose linearity in AUC and Cmax over the dose range tested (10-80 IU per animal). The relative bioavailability (BA) of IN oxytocin to IM injection was approximately 12%. The 80 IU formulation exhibited good physical stability and consistent dosing. After 12 months at 30°C/65%RH, pouched samples retained 86.0% of their original assay value. CONCLUSIONS: The PK and stability data suggests that IN administration of oxytocin formulated in the µco™ carrier may represent a viable option for rapid systemic absorption in humans and a product compatible with resource-scarce regions.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Absorção Nasal/fisiologia , Ocitocina/administração & dosagem , Ocitocina/metabolismo , Administração Intranasal , Animais , Estudos Cross-Over , Macaca fascicularis , Masculino , Absorção Nasal/efeitos dos fármacos , Ocitócicos/administração & dosagem , Ocitócicos/metabolismo , Fatores de Tempo
10.
Ther Deliv ; 5(3): 297-317, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24592955

RESUMO

Over the past decade, orally inhaled fixed-dose combination products (FDCs) have emerged as an important therapeutic class for the treatment of asthma and chronic obstructive pulmonary disease. However, the conceptual simplicity of inhaled FDCs belies both the complexity of their development, and the profound advantages they offer patients. The benefits of combining agents are not merely additive, and range from increased compliance via simple convenience to complex receptor-level synergies. Similarly, though, the development challenges often exceed the sum of their parts. FDC formulation and analytical method development is generally more complex than for two monotherapy products. Likewise, FDC clinical programs can easily eclipse those of their monotherapy peers and their inherent complexity is often furthered by the diverse regulatory requirements for worldwide approval. As such, the proposition of developing an orally inhaled FDC for global registration often represents a significant increase in both the potential rewards and assumed risks of drug development.


Assuntos
Antiasmáticos/administração & dosagem , Asma/tratamento farmacológico , Broncodilatadores/administração & dosagem , Cálculos da Dosagem de Medicamento , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Administração por Inalação , Aerossóis , Antiasmáticos/normas , Broncodilatadores/normas , Química Farmacêutica , Aprovação de Drogas , Combinação de Medicamentos , Humanos , Nebulizadores e Vaporizadores , Tamanho da Partícula , Controle de Qualidade , Tecnologia Farmacêutica/métodos
12.
PLoS Med ; 2(7): e182, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16013921

RESUMO

BACKGROUND: More than 35 million people in developing countries are living with HIV infection. An enormous global effort is now underway to bring antiretroviral treatment to at least 3 million of those infected. While drug prices have dropped considerably, the cost and technical complexity of laboratory tests essential for the management of HIV disease, such as CD4 cell counts, remain prohibitive. New, simple, and affordable methods for measuring CD4 cells that can be implemented in resource-scarce settings are urgently needed. METHODS AND FINDINGS: Here we describe the development of a prototype for a simple, rapid, and affordable method for counting CD4 lymphocytes. Microliter volumes of blood without further sample preparation are stained with fluorescent antibodies, captured on a membrane within a miniaturized flow cell and imaged through microscope optics with the type of charge-coupled device developed for digital camera technology. An associated computer algorithm converts the raw digital image into absolute CD4 counts and CD4 percentages in real time. The accuracy of this prototype system was validated through testing in the United States and Botswana, and showed close agreement with standard flow cytometry (r = 0.95) over a range of absolute CD4 counts, and the ability to discriminate clinically relevant CD4 count thresholds with high sensitivity and specificity. CONCLUSION: Advances in the adaptation of new technologies to biomedical detection systems, such as the one described here, promise to make complex diagnostics for HIV and other infectious diseases a practical global reality.


Assuntos
Contagem de Linfócito CD4 , Linfócitos T CD4-Positivos/metabolismo , Linfócitos T CD4-Positivos/virologia , Infecções por HIV/sangue , Análise de Sequência com Séries de Oligonucleotídeos/economia , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Algoritmos , Membrana Eritrocítica/virologia , Eritrócitos/virologia , Citometria de Fluxo , Humanos , Processamento de Imagem Assistida por Computador , Microscopia de Fluorescência , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação
13.
Biosens Bioelectron ; 21(2): 303-12, 2005 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-16023957

RESUMO

The development of a micromachined fluidic structure for the introduction of liquid samples into a chip-based sensor array composed of individually addressable polymeric microbeads is presented. The micromachined structure consists of micromachined storage cavities combined with a covering glass layer that confines the microbeads and fluidic channels. In our sensor array transduction occurs via optical (colorimetric and fluorescence) changes to receptors and indicator molecules that are covalently attached to termination sites on the polymeric microbeads. Spectral data are acquired for each of the individual microbeads using a charged-coupled device (CCD) allowing for the near-real-time analysis of liquid sample. Hence the micromachined fluidic structure must allow for both optical access to the microbeads and fluid flow through the micromachined cavities that serve as the microreactors/analysis chambers. One of the key parts of the structure is a passive fluid introduction system driven only by capillary force. This simple means of fluid introduction realizes a compact device. The capillary flow on the inlet channel has been studied, and the responses of the microbeads (alizarin complexone) to a liquid sample have been characterized. The test results show that this system is useful in a micro-total-analysis-system (mu-TAS) and biomedical applications.


Assuntos
Biomimética/instrumentação , Técnicas Biossensoriais/instrumentação , Misturas Complexas/análise , Eletroforese em Microchip/instrumentação , Análise em Microsséries/instrumentação , Paladar/fisiologia , Língua/fisiologia , Biomimética/métodos , Técnicas Biossensoriais/métodos , Ação Capilar , Materiais Revestidos Biocompatíveis/análise , Materiais Revestidos Biocompatíveis/química , Eletroforese em Microchip/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Análise em Microsséries/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Microesferas , Transdutores
14.
Anal Chem ; 75(18): 4732-9, 2003 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-14674448

RESUMO

The development of a chip-based sensor array composed of individually addressable agarose microbeads has been demonstrated for the rapid detection of DNA oligonucleotides. Here, a "plug and play" approach allows for the simple incorporation of various biotinylated DNA capture probes into the bead-microreactors, which are derivatized in each case with avidin docking sites. The DNA capture probe containing microbeads are selectively arranged in micromachined cavities localized on silicon wafers. The microcavities possess trans-wafer openings, which allow for both fluid flow through the microreactors/analysis chambers and optical access to the chemically sensitive microbeads. Collectively, these features allow the identification and quantitation of target DNA analytes to occur in near real time using fluorescence changes that accompany binding of the target sample. The unique three-dimensional microenvironment within the agarose bead and the microfluidics capabilities of the chip structure afford a fully integrated package that fosters rapid analyses of solutions containing complex mixtures of DNA oligomers. These analyses can be completed at room temperature through the use of appropriate hybridization buffers. For applications requiring analysis of < or = 10(2) different DNA sequences, the hybridization times and point mutation selectivity factors exhibited by this bead array method exceed in many respects the operational characteristics of the commonly utilized planar DNA chip technologies. The power and utility of this microbead array DNA detection methodology is demonstrated here for the analysis of fluids containing a variety of similar 18-base oligonucleotides. Hybridization times on the order of minutes with point mutation selectivity factors greater than 10000 and limit of detection values of approximately 10(-13) M are obtained readily with this microbead array system.


Assuntos
Pareamento Incorreto de Bases , DNA/química , Hibridização de Ácido Nucleico , Reprodutibilidade dos Testes
15.
J Am Chem Soc ; 125(10): 2870-1, 2003 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-12617642

RESUMO

The development of miniaturized chromatographic systems localized within individual polymer microspheres and their incorporation into a bead-based cross-reactive sensor array platform is reported. The integrated chromatographic and detection concept is based on the creation of distinct functional layers within the microspheres. In this first example of the new methodology, complexing ligands have been selectively immobilized to create "separation" layers harboring an affinity for various metal cations. Additionally, a broadly responsive compleximetric dye is used to yield the "detection" layers that exhibit optical responses in the presence of a wide range of metal cations. Information concerning the identities and concentrations of solution-dissolved metal cations can be drawn from the temporal properties of the beads' optical responses. Varying the nature of the ligand in the separation shell yields a collection of cross-reactive sensing elements well-suited for use in array-based micrototal analysis systems. Accordingly, such beads have been incorporated into the "Electronic Taste Chip" platform and used for discriminating among aqueous metal cation solutions.


Assuntos
Antraquinonas/química , Cromatografia/métodos , Ácido Edético/química , Microesferas , Polietilenoglicóis/química , Poliestirenos/química
16.
Anal Chem ; 74(13): 3030-6, 2002 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-12141661

RESUMO

The development of a novel chip-based multianalyte detection system with a cardiac theme is reported. This work follows the initial reports of "electronic taste chips" whereby multiple solution-phase analytes such as acids, bases, metal cations, and biological cofactors were detected and quantitated. The newly fashioned "cardiac chip" exploits a geometry that allows for isolation and entrapment of single polymeric spheres in micromachined pits while providing to each bead the rapid introduction of a series of reagents/washes through microfluidic structures. The combination of these miniaturized components fosters the completion of complex assays with short analysis times using small sample volumes. Optical signals derived from single beads are used to complete immunological tests that yield outstanding assay characteristics. The power and utility of this new methodology is demonstrated here for the simultaneous detection of the cardiac risk factors, C-reactive protein and interleukin-6, in human serum samples. This demonstration represents the first important step toward the development of a useful cardiac chip that targets numerous risk factors concurrently and one that can be customized readily for specific clinical settings.


Assuntos
Análise Química do Sangue/instrumentação , Doenças Cardiovasculares/diagnóstico , Medição de Risco/métodos , Humanos , Imunoensaio , Indicadores e Reagentes , Microcomputadores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...