Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 11(1): 3320, 2021 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-33558566

RESUMO

Analysis of several pulse shape properties generated by a Geiger Mueller (GM) detector and its dependence on applied voltage was performed. The two-source method was utilized to measure deadtime while simultaneously capturing pulse shape parameters on an oscilloscope. A wide range of operating voltages (600-1200 V) beyond the recommended operating voltage of 900 V was investigated using three radioactive sources (204Tl, 137Cs, 22Na). This study investigates the relationship between operating voltage, pulse shape properties, and deadtime of the detector. Based on the data, it is found that deadtime decreases with increasing voltage from 600 to 650 V. At these low voltages (600-650 V), the collection time was long, allowing sufficient time for some recombination to take place. Increasing the voltage in this range decreased the collection time, and hence deadtime decreased. It is also observed that rise and fall time were at their highest at these applied voltages. Increasing the voltage further would result in gas multiplication, where deadtime and pulse width are observed to be increasing. After reaching the maximum point of deadtime (~ 250 µs at ~ 700 V), deadtime started to exponentially decrease until a plateau was reached. In this region, it is observed that detector deadtime and operating voltage show a strong correlation with positive pulse width, rise and fall time, cycle mean, and area. Therefore, this study confirms a correlation between detector deadtime, operating voltage, and pulse shape properties. The results will validate our hypothesis that deadtime phenomena at different operating voltages are phenomenologically different.

2.
Sci Rep ; 10(1): 19955, 2020 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-33203933

RESUMO

A detailed analysis of Geiger Mueller counter deadtime dependence on operating voltage is presented in the manuscript using four pairs of radiation sources. Based on two-source method, detector deadtime is calculated for a wide range of operating voltages which revealed a peculiar relationship between the operating voltage and the detector deadtime. In the low voltage range, a distinct drop in deadtime was observed where deadtime reached a value as low as a few microseconds (22 µs for 204Tl, 26 µs for 137Cs, 9 µs for 22Na). This sharp drop in the deadtime is possibly due to reduced recombination with increasing voltage. After the lowest point, the deadtime generally increased rapidly to reach a maximum (292 µs for 204Tl, 277 µs for 137Cs, 258 µs for 22Na). This rapid increase in the deadtime is mainly due to the on-set of charge multiplication. After the maximum deadtime values, there was an exponential decrease in the deadtime reaching an asymptotic low where the manufacturer recommended voltage for operation falls. This pattern of deadtime voltage dependence was repeated for all sources tested with the exception of 54Mn. Low count rates leading to a negative deadtime suggested poor statistical nature of the data collected for 54Mn and the data while being presented here is not used for any inference.

3.
Sci Rep ; 9(1): 19591, 2019 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-31862995

RESUMO

Concerns about the effects of global warming provide a strong case to consider how best nuclear power could be applied to marine propulsion. Currently, there are persistent efforts worldwide to combat global warming, and that also includes the commercial freight shipping sector. In an effort to decarbonize the marine sector, there are growing interests in replacing the contemporary, traditional propulsion systems with nuclear propulsion systems. The latter system allows freight ships to have longer intervals before refueling; subsequently, lower fuel costs, and minimal carbon emissions. Nonetheless, nuclear propulsion systems have remained largely confined to military vessels. It is highly desirable that a civil marine core not use soluble boron for reactivity control, but it is then a challenge to achieve an adequate shutdown margin throughout the core life while maintaining reactivity control and acceptable power distributions in the core. High-thickness ZrB2 150 µm Integral Fuel Burnable Absorber (IFBA) is an excellent burnable poison (BP) candidate for long life soluble-boron-free core. However, in this study, we want to minimize the use of 150 µm IFBA since B-10 undergoes an (n, α) capture reaction, and the resulting helium raises the pressure within the plenum and in the cladding. Therefore, we have considered several alternative and novel burnable BP design strategies to minimize the use of IFBA for reactivity control in this study: (Case 1) a composite BP: gadolinia (Gd2O3) or erbia (Er2O3) with 150 µm thickness ZrB2 IFBA; (Case 2) Pu-240 or Am-241 mixed homogeneously with the fuel; and (Case 3) another composite BP: Pu-240 or Am-241 with 150 µm thickness ZrB2 IFBA. The results are compared against those for a high-thickness 150 µm 25 IFBA pins design from a previous study. The high-thickness 150 µm 25 IFBA pins design is termed the "IFBA-only" BP design throughout this study. We arrive at a design using 15% U-235 fuel loaded into 13 × 13 assemblies with Case 3 BPs (IFBA+Pu-240 or IFBA+Am-241) for reactivity control while reducing 20% IFBA use. This design exhibits lower assembly reactivity swing and minimal burnup penalty due to the self-shielding effect. Case 3 provides ~10% more initial (beginning-of-life) reactivity suppression with ~70% less reactivity swing compared to the IFBA-only design for UO2 fuel while achieving almost the same core lifetime. Finally, optimized Case 3 assemblies were loaded in 3D nodal diffusion and reactor model code. The results obtained from the 3D reactor model confirmed that the designed core with the proposed Case 3 BPs can achieve the target lifetime of 15 years while contributing to ~10% higher BOL reactivity suppression, ~70% lower reactivity swings, ~30% lower radial form factor and ~28% lower total peaking factor compared to the IFBA-only core.

SELEÇÃO DE REFERÊNCIAS