Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Catheter Cardiovasc Interv ; 102(6): 1140-1148, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37668110

RESUMO

BACKGROUND: Preprocedural computed tomography planning improves procedural safety and efficacy of transcatheter aortic valve implantation (TAVI). However, contemporary imaging modalities do not account for device-host interactions. AIMS: This study evaluates the value of preprocedural computer simulation with FEops HEARTguideTM on overall device success in patients with challenging anatomies undergoing TAVI with a contemporary self-expanding supra-annular transcatheter heart valve. METHODS: This prospective multicenter observational study included patients with a challenging anatomy defined as bicuspid aortic valve, small annulus or severely calcified aortic valve. We compared the heart team's transcatheter heart valve (THV) planning decision based on (1) conventional multislice computed tomography (MSCT) and (2) MSCT imaging with FEops HEARTguideTM simulations. Clinical outcomes and THV performance were followed up to 30 days. RESULTS: A total of 77 patients were included (median age 79.9 years (IQR 74.2-83.8), 42% male). In 35% of the patients, preprocedural planning changed after FEops HEARTguideTM simulations (change in valve size selection [12%] or target implantation height [23%]). A new permanent pacemaker implantation (PPI) was implanted in 13% and >trace paravalvular leakage (PVL) occurred in 28.5%. The contact pressure index (i.e., simulation output indicating the risk of conduction abnormalities) was significantly higher in patients with a new PPI, compared to those without (16.0% [25th-75th percentile 12.0-21.0] vs. 3.5% [25th-75th percentile 0-11.3], p < 0.01) The predicted PVL was 5.7 mL/s (25th-75th percentile 1.3-11.1) in patients with none-trace PVL, 12.7 (25th-75th percentile 5.5-19.1) in mild PVL and 17.7 (25th-75th percentile 3.6-19.4) in moderate PVL (p = 0.04). CONCLUSION: FEops HEARTguideTM simulations may provide enhanced insights in the risk for PVL or PPI after TAVI with a self-expanding supra-annular THV in complex anatomies.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Simulação por Computador , Estudos Prospectivos , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Tomografia Computadorizada Multidetectores/métodos , Desenho de Prótese
2.
Cardiovasc Revasc Med ; 57: 1-5, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37429793

RESUMO

BACKGROUND/PURPOSE: This prospective, open-label, single-arm study evaluated transcatheter aortic valve replacement (TAVR) in patients with severe aortic stenosis with ACURATE Prime XL, an iteration of the ACURATE neo2 device designed with improved radial force and adaptations for compatibility with a larger annulus diameter (≥ 26.5 mm and ≤ 29 mm based on pre-procedure diagnostic imaging). METHODS: The composite primary device success endpoint was based on Valve Academic Research Consortium (VARC)-2 criteria. The primary safety endpoint was a composite of all-cause mortality and all stroke at 30 days. Aortic valve (AV) performance, including mean AV gradient, AV area, and grade of paravalvular leak (PVL), was assessed by an independent core laboratory. RESULTS: 13 male patients were enrolled at 3 Australian centers (mean age: 83.1 years; 10 of 13 were considered high/extreme operative risk). 61.5 % of patients met the primary device success endpoint. At 30 days, no patients experienced death or stroke; one patient received a permanent pacemaker. Mean AV gradient improved from baseline (42.7 ± 11.0 mmHg) to discharge (7.7 ± 2.5 mmHg) and through 30 days (7.2 ± 2.3 mmHg). Mean AV area was 0.8 ± 0.1 cm2 at baseline, 1.9 ± 0.3 cm2 at discharge, and 1.7 ± 0.3 cm2 at 30 days. Per core-laboratory adjudication, no patient had moderate or severe PVL at 30 days; 91.7 % had no/trace PVL and 8.3 % had mild PVL. CONCLUSIONS AND RELEVANCE: In this first-in-human feasibility study of the ACURATE Prime XL valve, there were no safety concerns, and no deaths or strokes within 30 days. Valve hemodynamics were favorable, and no patient had >mild PVL.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Austrália , Estudos de Viabilidade , Estudos Prospectivos , Desenho de Prótese , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
3.
JACC Heart Fail ; 11(8 Pt 2): 1121-1130, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37115132

RESUMO

BACKGROUND: Most approaches to the creation of an interatrial shunt require placement of a permanent implant to maintain patency. OBJECTIVES: The goal of this study was to investigate the safety and efficacy of a no-implant interatrial shunt for patients with heart failure with preserved ejection fraction (HFpEF) and heart failure with mildly reduced ejection fraction (HFmrEF). METHODS: This was a multicenter, uncontrolled study of patients with HFpEF/HFmrEF and NYHA functional class ≥II, ejection fraction >40%, and pulmonary capillary wedge pressure (PCWP) during supine exercise ≥25 mm Hg with PCWP-to-right atrial gradient ≥5 mm Hg. Follow-up was through 6 months with imaging to assess shunt durability. RESULTS: A total of 28 patients were enrolled: mean age was 68 ± 9 years, and 68% were female. Baseline resting and peak exercise PCWP were 19 ± 7 mm Hg and 40 ± 11 mm Hg, respectively. All procedures displayed technical success with confirmation of left-to-right flow (shunt diameter 7.1 ± 0.9 mm). At 1 month, peak exercise PCWP decreased 5.4 ± 9.6 mm Hg (P = 0.011) with no change in right atrial pressure. There were no serious device or procedure-related adverse events through 6 months. Mean 6-minute walk distance increased 101 ± 71 meters (P < 0.001); Kansas City Cardiomyopathy Questionnaire Overall Summary Score increased 26 ± 19 points (P < 0.001); N-terminal pro-B-type natriuretic peptide decreased 372 ± 857 pg/mL (P = 0.018); and shunt patency was confirmed with unchanged diameter. CONCLUSIONS: In these feasibility studies of a no-implant interatrial shunt, HFpEF/HFmrEF shunts exhibited stability with favorable safety and early efficacy signals. The results show promise toward this new approach for treating patients with HFpEF/HFmrEF and an appropriate hemodynamic profile. (Evaluation of the Safety and Feasibility of a Percutaneously Created Interatrial Shunt to Alleviate Heart Failure Symptoms in Patients With Chronic Heart Failure and Preserved or Mid-Range Left Ventricular Ejection Fraction [ALLEVIATE-HF-1]; NCT04583527; Evaluation of the Safety and Effectiveness of a Percutaneously Created Interatrial Shunt to Alleviate Heart Failure Symptoms in Patients With Chronic Heart Failure and Preserved or Mid-Range Left Ventricular Ejection Fraction [ALLEVIATE-HF-2]; NCT04838353).


Assuntos
Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Volume Sistólico , Função Ventricular Esquerda , Estudos de Viabilidade , Cateterismo Cardíaco , Disfunção Ventricular Esquerda/etiologia
4.
Cardiovasc Revasc Med ; 51: 31-37, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36740551

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat younger, lower-risk patients with bicuspid aortic valve (BAV). Patient-specific computer simulation may identify patients at risk for developing paravalvular regurgitation (PVR) and major conduction disturbance. Only limited prospective experience of this technology exist. We wished to describe our ongoing experience with patient-specific computer simulation. METHODS: Patients who were referred for consideration of TAVR with a self-expanding transcatheter heart valve (THV) and had BAV identified on pre-procedural cardiac computed tomography imaging underwent patient-specific computer simulation. The computer simulations were reviewed by the Heart Team and used to guide surgical or transcatheter treatment approaches and to aid in THV sizing and positioning. Clinical outcomes were recorded. RESULTS: Between May 2019 and May 2021, 16 patients with BAV were referred for consideration of TAVR with a self-expanding THV. Sievers Type 1 morphology was present in 15 patients and Type 0 in the remaining patient. Two patients were predicted to develop moderate-to-severe PVR with a TAVR procedure and these patients underwent successful surgical aortic valve replacement. In the remaining 14 patients, computer simulation was used to optimize THV sizing and positioning to minimise PVR and conduction disturbance. One patient with a low valve implantation depth developed moderate PVR and this complication was correctly predicted by the computer simulations. No patient required insertion of a new permanent pacemaker. CONCLUSION: Patient-specific computer simulation may be used to guide the most appropriate treatment modality for patients with BAV. The usage of computer simulation to guide THV sizing and positioning was associated with favourable clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Doença da Válvula Aórtica Bicúspide/etiologia , Doença da Válvula Aórtica Bicúspide/cirurgia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Simulação por Computador , Estudos Prospectivos , Tomografia Computadorizada Multidetectores , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese
5.
J Cardiovasc Comput Tomogr ; 17(1): 2-10, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36396555

RESUMO

Subclinical leaflet thrombosis (LT) may occur following surgical and transcatheter aortic valve replacement. Computed tomography (CT) has become an established imaging modality to diagnose subclinical LT following bioprosthetic aortic valve replacement. Even so, there is a limited (but growing) experience in utilizing CT imaging for this indication. This review emphasizes a systematic approach to acquiring and analysing CT imaging for subclinical LT, highlighting evidence surrounding clinical sequelae of subclinical LT and anti-thrombotic implications following diagnosis.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Fatores de Risco , Valor Preditivo dos Testes , Valva Aórtica/cirurgia , Tomografia Computadorizada por Raios X , Estenose da Valva Aórtica/cirurgia , Trombose/cirurgia , Resultado do Tratamento
6.
N Engl J Med ; 387(14): 1253-1263, 2022 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-36121045

RESUMO

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) for the treatment of aortic stenosis can lead to embolization of debris. Capture of debris by devices that provide cerebral embolic protection (CEP) may reduce the risk of stroke. METHODS: We randomly assigned patients with aortic stenosis in a 1:1 ratio to undergo transfemoral TAVR with CEP (CEP group) or without CEP (control group). The primary end point was stroke within 72 hours after TAVR or before discharge (whichever came first) in the intention-to-treat population. Disabling stroke, death, transient ischemic attack, delirium, major or minor vascular complications at the CEP access site, and acute kidney injury were also assessed. A neurology professional examined all the patients at baseline and after TAVR. RESULTS: A total of 3000 patients across North America, Europe, and Australia underwent randomization; 1501 were assigned to the CEP group and 1499 to the control group. A CEP device was successfully deployed in 1406 of the 1489 patients (94.4%) in whom an attempt was made. The incidence of stroke within 72 hours after TAVR or before discharge did not differ significantly between the CEP group and the control group (2.3% vs. 2.9%; difference, -0.6 percentage points; 95% confidence interval, -1.7 to 0.5; P = 0.30). Disabling stroke occurred in 0.5% of the patients in the CEP group and in 1.3% of those in the control group. There were no substantial differences between the CEP group and the control group in the percentage of patients who died (0.5% vs. 0.3%); had a stroke, a transient ischemic attack, or delirium (3.1% vs. 3.7%); or had acute kidney injury (0.5% vs. 0.5%). One patient (0.1%) had a vascular complication at the CEP access site. CONCLUSIONS: Among patients with aortic stenosis undergoing transfemoral TAVR, the use of CEP did not have a significant effect on the incidence of periprocedural stroke, but on the basis of the 95% confidence interval around this outcome, the results may not rule out a benefit of CEP during TAVR. (Funded by Boston Scientific; PROTECTED TAVR ClinicalTrials.gov number, NCT04149535.).


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Embolia Intracraniana , Implantação de Prótese , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/etiologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Delírio/etiologia , Humanos , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle , Ataque Isquêmico Transitório/etiologia , Implantação de Prótese/instrumentação , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
7.
Cardiovasc Diagn Ther ; 12(3): 314-324, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35800353

RESUMO

Background: Quantitative flow ratio (QFR) may be used to assess the functional significance of coronary lesions. Only limited validation exists for this technology in the setting of severe aortic stenosis. Methods: A prospective study was performed on patients who were being considered for transcatheter aortic valve implantation. QFR analysis was performed (Medis Medical Imaging System, Leiden, The Netherlands) and compared to invasive measurements of haemodynamic assessment [fractional flow reserve (FFR), instantaneous wave-free ratio (iFR), diastolic pressure ratio during the wave-free period (dPR) and distal arterial pressure/arterial pressure (Pd/Pa)]. Results: A total of 35 patients were included in the study. Mean age was 75.5±6.5 and mean aortic valve gradient was 44.3±11.8 mmHg. There were 57 vessels analysed. The mean FFR was 0.83±0.10 and 22 vessels (39%) had a functionally significant FFR ≤0.80. QFR demonstrated a discriminatory power to predict functionally significant FFR [area under the receiver operating characteristic curve (AUC), 0.92; 95% confidence interval (CI): 0.84 to 1.00], representing a sensitivity of 73%, specificity of 91%, positive predictive value of 84%, negative predictive value of 84% and an accuracy of 84%. QFR also demonstrated a discriminatory power to predict functionally significant iFR ≤0.89 (AUC =0.92; 95% CI: 0.85 to 0.99), dPR ≤0.89 (AUC =0.90; 95% CI: 0.83 to 0.98) and Pd/Pa ≤0.92 (AUC =0.89; 95% CI: 0.80 to 0.97). Conclusions: QFR demonstrates acceptable diagnostic performance in patients with severe aortic stenosis when both FFR and non-hyperaemic pressure indices are used as reference standards.

9.
Heart Lung Circ ; 31(6): 787-794, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35165052

RESUMO

BACKGROUND: Countries who suffered large COVID-19 outbreaks reported a decrease in acute coronary syndrome (ACS) presentations and percutaneous coronary intervention (PCI). The impact of the pandemic in countries like Australia, with relatively small outbreaks yet significant social restrictions, is relatively unknown. There is also limited and conflicting data regarding the impact on clinical outcomes, symptom-to-door time (STDT) and door-to-balloon time (DTBT). METHODS: Consecutive ACS patients treated with PCI were prospectively recruited from a tertiary hospital network in Melbourne, Australia. The pre-pandemic period (11 March 2019-10 March 2020) was compared to the pandemic period (11 March 2020-10 May 2020) using an interrupted time series analysis with a primary endpoint of number PCI-treated ACS per day. Secondary endpoints included STDT, DTBT, total mortality and major adverse cardiac events (MACE). RESULTS: A total 984 ACS patients (14.8% during the pandemic period) received PCI. Mean number of PCI-treated ACS per day did not differ between the two periods (2.3 vs 2.4, p=0.61) with no difference in STDT [+51.3 mins, 95% confidence interval (CI) -52.4 to 154.9, p=0.33], 30-day mortality (5% vs 5.3%, p=0.86) or MACE (5.2% vs 6.1%, p=0.68). DTBT was significantly longer during the pandemic versus the pre-pandemic period (+18.1 mins, 95% CI 1.6-34.5, p=0.03) and improved with time (slope estimate: -0.76, 95% CI -1.62 to 0.10). CONCLUSIONS: Despite significant social restrictions imposed in Melbourne, numbers of ACS treated with PCI and 30-day outcomes were similar to pre-pandemic times. DTBT was significantly longer during the COVID-19 pandemic period, likely reflecting infection control measures, which reassuringly improved with time.


Assuntos
Síndrome Coronariana Aguda , COVID-19 , Intervenção Coronária Percutânea , Síndrome Coronariana Aguda/epidemiologia , Síndrome Coronariana Aguda/cirurgia , Austrália/epidemiologia , COVID-19/epidemiologia , Humanos , Pandemias , Resultado do Tratamento
10.
Cardiovasc Revasc Med ; 41: 47-52, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35131173

RESUMO

BACKGROUND: Instantaneous wave-free ratio (iFR) can reliably assess the physiological significance of coronary artery disease (CAD). Previous studies have demonstrated its interchangeability with other non-hyperaemic pressure ratios (NHPR), but there is no data exploring whether this association is maintained in patients with severe aortic stenosis (AS). METHODS: Forty-two patients (67 lesions) with severe AS were recruited and underwent invasive pressure-wire assessment. Data were extracted to calculate iFR, resting Pd/Pa, diastolic pressure ratios (DPR and dPR), and Diastolic Hyperaemia-Free Ratio (DFR). iFR was then compared with other NHPR to determine agreement and accuracy. RESULTS: Mean aortic gradient and dimensionless index were 44.3 ± 11.6 mmHg and 0.23 ± 0.04, respectively. Of the 67 vessels, 57% were LAD, 15% LCx, 13% RCA and 12% other. There was strong positive correlation between iFR and all other NHPR, including Pd/Pa (r = 0.91, p < 0.001), DPR (r = 0.99, p < 0.001), dPR (r = 0.97, p < 0.001) and DFR (r = 0.98, p < 0.001). While Bald-Altman analysis demonstrated that Pd/Pa and DFR were numerically different from iFR, ROC analyses demonstrated iFR ≤0.89 was accurately identified by all NHPRs; Pd/Pa (AUC = 0.965, 95% CI [0.928-0.994]), DPR (AUC = 1.000, 95% CI [1.000-1.000]), dPR (AUC = 0.974, 95% CI [0.937-1.000]), DFR (AUC = 0.989, 95% CI [0.968-1.000]). CONCLUSION: In patients with severe AS, all the included NHPR in this analysis accurately predicted iFR < 0.89. These data should reassure clinicians that use of alternative NHPR to iFR is reasonable when assessing the physiological significance of CAD in patients with severe AS.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Hiperemia , Estenose da Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Vasos Coronários , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Valor Preditivo dos Testes , Índice de Gravidade de Doença
11.
Heart Lung Circ ; 31(5): 678-684, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35065896

RESUMO

OBJECTIVE: To determine the association between prosthesis geometry with leaflet thrombosis (LT). BACKGROUND: Leaflet thrombosis following transcatheter aortic valve replacement (TAVR) is a recognised entity. The association between prosthesis geometry with LT is unclear but maybe a potential modifiable factor in its prevention. METHODS: Patients who received an intra-annular TAVR prosthesis and were prospectively planned to undergo post-procedural computed tomography (CT) imaging were included. Leaflet thrombosis was defined as at least 50% restricted leaflet motion on CT. Prosthesis expansion and eccentricity was measured at prosthesis inflow, annulus and outflow levels. Prosthesis misalignment was defined as the average angle deviation between native and prosthesis leaflet commissure, greater than 30°. RESULTS: Prevalence of LT was 13.7% in 117 patients. None of the patients with LT were on anticoagulation therapy. Patients with LT had reduced prosthesis annular expansion (89.4±5.2% vs 97.0±4.4%, p<0.01), greater prosthesis misalignment (81.3% vs 48.5%, p=0.02) and deeper implants (6.3±1.7 mm vs 4.3±1.5 mm, p<0.01). Threshold for the presence of LT on ROC analysis was an implant depth of 5.7 mm (AUC [area under curve]=0.81). Independent predictors of LT were annular under-expansion (Odds ratio [OR] 1.4, 95% confidence interval [CI] 1.2-1.7, p=0.03) prosthesis misalignment (OR 6.8, 95%CI 1.1-45.5, p=0.04) and implant depth (OR 1.9, 95%CI 1.1-3.2, p=0.03). Anticoagulation therapy was a protective factor (OR 0.2; 95%CI 0.1-0.4, p<0.01). CONCLUSION: Geometrical predictors of LT post intra-annular TAVR were reduced prosthesis expansion at the annular level, lower implant depth and greater prosthesis misalignment. These factors may be important considerations during procedural planning for TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Anticoagulantes/uso terapêutico , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Desenho de Prótese , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
J Cardiovasc Comput Tomogr ; 16(3): 254-261, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34887238

RESUMO

BACKGROUND: Patient-specific computer simulation may predict the development of paravalvular regurgitation (PVR) after transcatheter aortic valve replacement (TAVR). We hypothesised that patient-specific computer simulation might identify patients at risk for long-term adverse outcomes after TAVR. METHODS: A multi-centre retrospective study was performed on patients with symptomatic severe aortic stenosis who had undergone TAVR with a self-expanding transcatheter heart valve (THV). Pre-procedural cardiac computed tomography imaging was used to create finite element models of the aortic root. Finite element analysis (FEA) was performed in order to simulate the interaction between the THV and the native anatomy. The blood domain was extracted from the FEA output and computational fluid dynamics (CFD) simulation undertaken. Predicted PVR was recorded in the left ventricular outflow tract. Patients were classified into those where computer simulation predicted no significant PVR (predicted PVR from CFD <16.0 â€‹mL/s) and those where computer simulation predicted significant PVR (predicted PVR from CFD ≥16.0 â€‹mL/s). RESULTS: A total of 203 patients were included in the study. THVs implanted were CoreValve (n â€‹= â€‹20), Evolut R (n â€‹= â€‹90) and Evolut PRO (n â€‹= â€‹93). At 2 years, the Kaplan-Meier estimate of the rate of death from any cause was higher in the group where CFD simulation predicted significant PVR (35.8% vs. 16.3%; hazard ratio, 2.62; 95% confidence interval, 1.29 to 5.30; P â€‹= â€‹0.006 by log-rank test). CONCLUSIONS: Computer simulation may identify patients who are at a higher risk for death after TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Simulação por Computador , Humanos , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
13.
J Cardiovasc Comput Tomogr ; 16(2): 168-173, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34852974

RESUMO

BACKGROUND: Hypo-attenuated leaflet thickening (HALT) may occur following transcatheter aortic valve replacement (TAVR), however, it remains unclear if HALT is a predictor of haemodynamic valve deterioration (HVD). AIM: To determine the impact of HALT on the occurrence of HVD. METHODS: We prospectively evaluated 186 patients for the presence of HALT at a median of 6 weeks following TAVR (Interquartile-range [IQR] 4-12 weeks). HALT depth and area were measured. HVD encompassed any of the following: mean gradient ≥20 â€‹mmHg with an increase in gradient ≥10 â€‹mmHg from baseline, Doppler velocity index reduction ≥0.1 or new moderate-to-severe valvular regurgitation. Routine echocardiograms at discharge, one month and annually, were assessed by echo-cardiologists that were blinded to the HALT status. RESULTS: LT prevalence was 17.7% (33/186). HVD was present in 8.6% (16/186) at a median follow-up of 2 years (IQR 1-3); two required valve re-intervention and five required anticoagulation. HALT was the only independent predictor of HVD on multivariate analysis (OR 33.3, 95%CI 7.4-125). Patients with HALT were more likely to develop HVD, require repeat valve intervention and have higher trans-valvular gradients at up to 3-year follow-up. Patients with HALT had a median cumulative thickness of 2.9 â€‹mm (IQR 1.9-4.7) and area of 64.2 â€‹mm2 (IQR 40.9-91.6). Thresholds for HALT in predicting HVD were a cumulative depth of 2.4 â€‹mm (Specificity 94.1%, Sensitivity 75.0%, AUC â€‹= â€‹0.87) and cumulative area of 28 â€‹mm2 (Specificity 92.2%, Sensitivity 81.3%, AUC â€‹= â€‹0.86). CONCLUSION: HALT is an independent predictor of HVD, which exhibits specific depth and area thresholds to predict HVD. CT following TAVR may determine patients at risk of HVD.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Valor Preditivo dos Testes , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
Struct Heart ; 6(3): 100010, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37274548

RESUMO

Background: Patient-specific computer simulation may predict the development of conduction disturbance following transcatheter aortic valve replacement (TAVR). Validation of the computer simulations with current-generation devices has not been undertaken. Methods: A retrospective study was performed on patients who had undergone TAVR with a current-generation self-expanding transcatheter heart valve (THV). Preprocedural computed tomography imaging was used to create finite element models of the aortic root. Procedural contrast angiography was reviewed, and finite element analysis performed using a matching THV device size and implantation depth. A region of interest corresponding to the atrioventricular bundle and proximal left bundle branch was identified. The percentage of this area (contact pressure index [CPI]) and maximum contact pressure (CPMax) exerted by THV were recorded. Postprocedural electrocardiograms were reviewed, and major conduction disturbance was defined as the development of persistent left bundle branch block or high-degree atrioventricular block. Results: A total of 80 patients were included in the study. THVs were 23- to 29-mm Evolut PRO (n = 53) and 34-mm Evolut R (n = 27). Major conduction disturbance occurred in 27 patients (33.8%). CPI (28.3 ± 15.8 vs. 15.6 ± 11.2%; p < 0.001) and CPMax (0.51 ± 0.20 vs. 0.36 ± 0.24 MPa; p = 0.008) were higher in patients who developed major conduction disturbance. CPI (area under the receiver operating characteristic curve [AUC], 0.74; 95% CI, 0.63-0.86; p < 0.001) and CPMax (AUC, 0.69; 95% CI, 0.57-0.81; p = 0.006) demonstrated a discriminatory power to predict the development of major conduction disturbance. Conclusions: Patient-specific computer simulation may identify patients at risk for conduction disturbance after TAVR with current-generation self-expanding THVs.

15.
Interv Cardiol ; 16: e26, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34721665

RESUMO

Transcatheter aortic valve implantation (TAVI) is increasingly being used to treat younger, lower-risk patients, many of whom have bicuspid aortic valve (BAV). As TAVI begins to enter these younger patient cohorts, it is critical that clinical outcomes from TAVI in BAV are matched to those achieved by surgery. Therefore, the identification of patients who, on an anatomical basis, may not be suitable for TAVI, would be desirable. Furthermore, clinical outcomes of TAVI in BAV might be improved through improved transcatheter heart valve sizing and positioning. One potential solution to these challenges is patient-specific computer simulation. This review presents the methodology and clinical evidence surrounding patient-specific computer simulation of TAVI in BAV.

16.
Int J Cardiol ; 332: 143-147, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33775789

RESUMO

BACKGROUND: Patients with severe aortic stenosis (AS) exhibit systemic endothelial dysfunction, which can be associated with myocardial ischaemia in absence of obstructive coronary disease. Transcatheter aortic valve replacement (TAVR) is used to treat severe AS in patients with high or prohibitive surgical risk. However, it remains unknown whether endothelial function recovers post-TAVR. We therefore sought to assess the early and late changes in flow-mediated dilation (FMD), a measure of endothelial function, following TAVR. METHODS: Patients undergoing TAVR for severe AS had ultrasound assessment of brachial endothelial-independent and -dependent FMD. Measurements were performed pre-TAVR, at early follow-up (<48 h post-TAVR) and late follow-up (4-6 weeks post-TAVR). RESULTS: 27 patients (mean age 82.0 ± 7.0; 33.3% female) were recruited; 37.0% had diabetes mellitus and 59.3% had hypertension. Brachial artery FMD increased from 4.2 ± 1.6% (pre-TAVR) to 9.7 ± 3.5% at early follow-up (p < 0.0001). At late follow-up, improvement compared with early follow-up was sustained (8.7 ± 1.9%, p = 0.27). Resting brachial arterial flow velocities decreased significantly at late follow-up (11.24 ± 5.16 vs. 7.73 ± 2.79 cm/s, p = 0.003). Concordantly, at late follow-up, there was decrease in resting wall shear stress (WSS; 14.8 ± 7.8 vs. 10.6 ± 4.8dyne/cm2, p = 0.01), peak WSS (73.1 ± 34.1 vs. 58.8 ± 27.8dyne/cm2, p = 0.03) and cumulative WSS (3543 ± 1852 vs. 2504 ± 1089dyne·s/cm2, p = 0.002). Additionally, a favourable inverse correlation between cumulative WSS and FMD was restored at late follow-up (r = -0.21 vs. r = 0.49). CONCLUSION: Endothelial function in patients with AS improves early post-TAVR and this improvement is sustained. This likely occurs as a result of improved arterial haemodynamics, leading to lower localised WSS and release of vasoactive mediators that may also alleviate myocardial ischaemia.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Coração , Hemodinâmica , Humanos , Masculino , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
17.
Heart Vessels ; 36(9): 1374-1383, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33660057

RESUMO

BACKGROUND: The clinical predictors and sequelae of leaflet thrombosis (LT) following transcatheter aortic valve replacement (TAVR) is still unclear. Therefore, our aim was to determine the clinical predictors and sequelae at mid-term follow-up of computed tomography (CT)-defined LT following TAVR. METHODS AND RESULTS: We performed a prospective evaluation with a 320-multislice CT following TAVR for the presence of LT, defined as hypo-attenuated leaflet thickening (HALT). Four-dimensional CT image-rendering was performed to determine the presence of reduced leaflet motion (RELM). 172 patients [89 (51.7%) male, mean age 82.8 ± 5.7 years] treated with commercially available TAVR device (Lotus 54%, CoreValve 32% and Sapien 3 14%) were included, with median CT-scan at 6.0 weeks post-TAVR. Prevalence of HALT was 14.0% (24 cases) and RELM was 9.8% (17 cases). On multivariate analysis, patients with HALT were less prescribed oral anticoagulation (OAC) (OR 9.9), received larger TAVR prostheses (OR 5.7) and higher rates of moderate-severe para-valvular regurgitation (PVR) (OR 16.3). There was no difference in clinical outcomes at a median follow-up of 2.3 years. Patients with RELM had significantly higher transvalvular gradients after discharge when compared to those without RELM. CONCLUSIONS: Absence of OAC, large TAVR prostheses and moderate-severe PVR were predictors for LT. Transvalvular gradients were higher in patients that developed RELM but not HALT. Further studies are warranted to determine the long-term impact of LT on TAVR durability. Prevalence of different sub-types of CT-defined LT (HALT and RELM) and the clinical predictors of developing LT following TAVR. CT computed tomography, HALT hypo-attenuated leaflet thickening, LT leaflet thrombosis, RELM reduced leaflet motion, TAVR transcatheter aortic valve replacement.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
19.
Circ Cardiovasc Interv ; 14(1): e009586, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33322917

RESUMO

BACKGROUND: Coronary artery disease is common in patients with severe aortic stenosis. Computed tomography-derived fractional flow reserve (CT-FFR) is a clinically used modality for assessing coronary artery disease, however, its use has not been validated in patients with severe aortic stenosis. This study assesses the safety, feasibility, and validity of CT-FFR in patients with severe aortic stenosis. METHODS: Prospectively recruited patients underwent standard-protocol invasive FFR and coronary CT angiography (CTA). CTA images were analyzed by central core laboratory (HeartFlow, Inc) for independent evaluation of CT-FFR. CT-FFR data were compared with FFR (ischemia defined as FFR ≤0.80). RESULTS: Forty-two patients (68 vessels) underwent FFR and CTA; 39 patients (92.3%) and 60 vessels (88.2%) had interpretable CTA enabling CT-FFR computation. Mean age was 76.2±6.7 years (71.8% male). No patients incurred complications relating to premedication, CTA, or FFR protocol. Mean FFR and CT-FFR were 0.83±0.10 and 0.77±0.14, respectively. CT calcium score was 1373.3±1392.9 Agatston units. On per vessel analysis, there was positive correlation between FFR and CT-FFR (Pearson correlation coefficient, R=0.64, P<0.0001). Sensitivity, specificity, positive predictive value, and negative predictive values were 73.9%, 78.4%, 68.0%, and 82.9%, respectively, with 76.7% diagnostic accuracy. The area under the receiver-operating characteristic curve for CT-FFR was 0.83 (0.72-0.93, P<0.0001), which was higher than that of CTA and quantitative coronary angiography (P=0.01 and P<0.001, respectively). Bland-Altman plot showed mean bias between FFR and CT-FFR as 0.059±0.110. On per patient analysis, the sensitivity, specificity, positive predictive, and negative predictive values were 76.5%, 77.3%, 72.2%, and 81.0% with 76.9% diagnostic accuracy. The per patient area under the receiver-operating characteristic curve analysis was 0.81 (0.67-0.95, P<0.0001). CONCLUSIONS: CT-FFR is safe and feasible in patients with severe aortic stenosis. Our data suggests that the diagnostic accuracy of CT-FFR in this cohort potentially enables its use in clinical practice and provides the foundation for future research into the use of CT-FFR for coronary evaluation pre-aortic valve replacement.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Volume Sistólico , Tomografia Computadorizada por Raios X , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS