Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 203
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38499825

RESUMO

BACKGROUND: Cardioneuroablation has been emerging as a potential treatment alternative in appropriately selected patients with cardioinhibitory vasovagal syncope (VVS) and functional AV block (AVB). However the majority of available evidence has been derived from retrospective cohort studies performed by experienced operators. METHODS: The Cardioneuroablation for the Management of Patients with Recurrent Vasovagal Syncope and Symptomatic Bradyarrhythmias (CNA-FWRD) Registry is a multicenter prospective registry with cross-over design evaluating acute and long-term outcomes of VVS and AVB patients treated by conservative therapy and CNA. RESULTS: The study is a prospective observational registry with cross-over design for analysis of outcomes between a control group (i.e., behavioral and medical therapy only) and intervention group (Cardioneuroablation). Primary and secondary outcomes will only be assessed after enrollment in the registry. The follow-up period will be 3 years after enrollment. CONCLUSIONS: There remains a lack of prospective multicentered data for long-term outcomes comparing conservative therapy to radiofrequency CNA procedures particularly for key outcomes including recurrence of syncope, AV block, durable impact of disruption of the autonomic nervous system, and long-term complications after CNA. The CNA-FWRD registry has the potential to help fill this information gap.

2.
J Am Coll Cardiol ; 83(1): 109-279, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38043043

RESUMO

AIM: The "2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Patients With Atrial Fibrillation" provides recommendations to guide clinicians in the treatment of patients with atrial fibrillation. METHODS: A comprehensive literature search was conducted from May 12, 2022, to November 3, 2022, encompassing studies, reviews, and other evidence conducted on human subjects that were published in English from PubMed, EMBASE, the Cochrane Library, the Agency for Healthcare Research and Quality, and other selected databases relevant to this guideline. Additional relevant studies, published through November 2022, during the guideline writing process, were also considered by the writing committee and added to the evidence tables, where appropriate. STRUCTURE: Atrial fibrillation is the most sustained common arrhythmia, and its incidence and prevalence are increasing in the United States and globally. Recommendations from the "2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation" and the "2019 AHA/ACC/HRS Focused Update of the 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation" have been updated with new evidence to guide clinicians. In addition, new recommendations addressing atrial fibrillation and thromboembolic risk assessment, anticoagulation, left atrial appendage occlusion, atrial fibrillation catheter or surgical ablation, and risk factor modification and atrial fibrillation prevention have been developed.


Assuntos
Fibrilação Atrial , Cardiologia , Tromboembolia , Humanos , Estados Unidos/epidemiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/epidemiologia , American Heart Association , Fatores de Risco
3.
Pacing Clin Electrophysiol ; 47(1): 88-100, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38071456

RESUMO

Atrial fibrillation (AF) and heart failure are common overlapping cardiovascular disorders. Despite important therapeutic advances over the past several decades, controversy persists about whether a rate control or rhythm control approach constitutes the best option in this population. There is also considerable debate about whether antiarrhythmic drug therapy or ablation is the best approach when rhythm control is pursued.  A brief historical examination of the literature addressing this issue will be performed. An analysis of several important clinical outcomes observed in the prospective, randomized studies, which have compared AF ablation to non-ablation treatment options, will be discussed. This review will conclude with recommendations to guide clinicians on the status of AF ablation as a treatment option when considering management options in heart failure patients with atrial fibrillation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Humanos , Estudos Prospectivos , Antiarrítmicos/uso terapêutico , Insuficiência Cardíaca/terapia , Pacientes , Resultado do Tratamento
4.
JACC Clin Electrophysiol ; 10(1): 31-39, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37943190

RESUMO

BACKGROUND: Bilateral cardiac sympathetic denervation (BCSD) for refractory life-threatening ventricular arrhythmias is a neuromodulatory intervention targeting sympathetically driven focal or re-entrant ventricular arrhythmias. OBJECTIVES: This study sought to provide a more complete and successful option for intervention in patients in whom premature ventricular contraction (PVC) ablation is not feasible or has been unsuccessful. METHODS: A total of 43 patients with >5% PVC burden and concomitant nonischemic cardiomyopathy (NICM) who previously failed medical and ablation therapies were referred for BCSD. All patients underwent bilateral video-assisted thoracoscopic surgical approach with T1-T4 sympathectomy. Primary effectiveness endpoints were postprocedural PVC burden resolution, improvement in left ventricular ejection fraction (LVEF), and cessation of antiarrhythmic drugs (AADs). Safety endpoints included peri- and postprocedural complications. Outcomes were assessed over a 1-year follow-up period. RESULTS: Among the 43 patients who underwent BCSD, the mean age was 52.3 ± 14.7 years, 69.8% of whom were male patients. Presenting mean LVEF was 38.7% ± 7.8%, and PVC burden was 23.7% ± 9.9%. There were significant reductions in PVC burden postprocedurally (1.3% ± 1.1% post-BCSD, compared with 23.7% ± 9.9% pre-BCSD, P < 0.001) and improvements in LVEF (46.3% ± 9.5% post-BCSD, compared with 38.7% ± 7.8% pre-BCSD, P < 0.001). The rate of ICD therapies decreased from 81.4% (n = 35) to 11.6% (n = 5) (P < 0.001), leading to a significant reduction in use of AADs (100.0% to 11.6%, P < 0.001) and improvement in mean NYHA functional class (2.5 ± 0.5 to 1.4 ± 0.2, P < 0.001). Major intraoperative complications were seen in 4.7% of patients (hemothorax and chylothorax). Of the patients, 81.4% (n = 35) experienced no mortality or major complications over a 1-year follow-up period, with the remaining still within their first year postprocedure. CONCLUSIONS: BCSD is effective for the management of refractory PVCs and ventricular tachycardia who have failed previous ablation therapy.


Assuntos
Cardiomiopatias , Complexos Ventriculares Prematuros , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Volume Sistólico , Função Ventricular Esquerda , Antiarrítmicos/uso terapêutico , Simpatectomia/efeitos adversos , Simpatectomia/métodos
5.
J Interv Card Electrophysiol ; 67(3): 625-635, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37858000

RESUMO

BACKGROUND: Frailty is associated with significant morbidity and mortality and may have clinical implications in an advanced age population with atrial fibrillation undergoing left atrial appendage occlusion (LAAO). We sought to develop a novel frailty scale to predict worse outcomes in patients undergoing LAAO. METHODS: Patients in the NCDR LAAO Registry between 2016 and 2021 receiving percutaneous LAAO devices were categorized as non-frail (0 points), pre-frail (1-3 points), or frail (4-5 points) based on a 5-point scale representing multiple domains of frailty: hemoglobin <13.0 g/dL in male, <12.0 g/dL in female; creatinine ≥1.2 mg/dL; albumin <3.5 g/dL; body mass index <20 kg/m2; and increased risk of falls. RESULTS: Of 57,728 patients, 44,360 (76.8%) were pre-frail and 7693 (13.3%) were frail. Compared to non-frail, pre-frail and frail patients were older, had a higher burden of co-morbidities, and more disability based on the Modified Rankin Scale. Compared to non-frail patients after adjustment, frail patients were at higher risk of in-hospital major complication (OR 1.29, 95% 1.02-1.62, p = 0.01), any complication (OR 1.29, 95% CI 1.09-1.52, p = 0.0005), and death (OR 5.79, 95% CI 1.75-19.17, p = 0.001), while no difference was observed in pre-frail patients. At 45-day follow-up, there was no difference in the risk of complications in frail patients as compared to non-frail, although mortality was significantly higher (OR 3.01, 95% CI 1.97-4.85, p < 0.0001). CONCLUSION: A simple and practical frailty scale accurately predicts adverse events in patients undergoing LAAO. The 13% of patients considered frail were at significantly higher risk of in-hospital adverse events and 45-day mortality.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Fragilidade , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fragilidade/epidemiologia , Fragilidade/complicações , Estudos Retrospectivos , Sistema de Registros , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
6.
Circulation ; 149(1): e1-e156, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38033089

RESUMO

AIM: The "2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation" provides recommendations to guide clinicians in the treatment of patients with atrial fibrillation. METHODS: A comprehensive literature search was conducted from May 12, 2022, to November 3, 2022, encompassing studies, reviews, and other evidence conducted on human subjects that were published in English from PubMed, EMBASE, the Cochrane Library, the Agency for Healthcare Research and Quality, and other selected databases relevant to this guideline. Additional relevant studies, published through November 2022, during the guideline writing process, were also considered by the writing committee and added to the evidence tables, where appropriate. STRUCTURE: Atrial fibrillation is the most sustained common arrhythmia, and its incidence and prevalence are increasing in the United States and globally. Recommendations from the "2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation" and the "2019 AHA/ACC/HRS Focused Update of the 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation" have been updated with new evidence to guide clinicians. In addition, new recommendations addressing atrial fibrillation and thromboembolic risk assessment, anticoagulation, left atrial appendage occlusion, atrial fibrillation catheter or surgical ablation, and risk factor modification and atrial fibrillation prevention have been developed.


Assuntos
Fibrilação Atrial , Cardiologia , Tromboembolia , Humanos , American Heart Association , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Fatores de Risco , Estados Unidos/epidemiologia
8.
J Cardiovasc Electrophysiol ; 35(3): 592-600, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38013210

RESUMO

Continuous flow left ventricular assist devices (CF-LVADs) have been shown to reduce mortality and morbidity in patients with advanced heart failure with reduced ejection fraction. However, ventricular arrhythmias (VA) are common, are mostly secondary to underlying myocardial scar, and have a higher incidence in patients with pre-LVAD VA. Sustained VA is well tolerated in the LVAD patient but can result in implantable defibrillator (ICD) shocks, right ventricular failure, hospitalizations, and reduced quality of life. There is limited data regarding best practices for the medical management of VA as well as the role for procedural interventions in patients with uncontrolled VA and/or ICD shocks. Vast majority of CF-LVAD patients have a preexisting cardiovascular implantable electronic device (CIED) and ICD and/or cardiac resynchronization therapies are continued in many. Several questions, however, remain regarding the efficacy of ICD and CRT following CF-LVAD. Moreover, optimal CIED programming after CF-LVAD implantation. Therefore, the primary objective of this review article is to provide the most up-to-date evidence and to provide guidance on the clinical significance, pathogenesis, predictors, and management strategies for VA and ICD therapies in the CF-LVAD population. We also discuss knowledge gaps as well as areas for future research.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Desfibriladores Implantáveis/efeitos adversos , Coração Auxiliar/efeitos adversos , Qualidade de Vida , Arritmias Cardíacas/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia
9.
Artigo em Inglês | MEDLINE | ID: mdl-37882994

RESUMO

BACKGROUND: Over 100,000 Abbott Riata® were implanted in the United States before they were recalled in 2010. There are still a significant number of Abbott Riata® leads in use, and it is unclear how these leads should be managed at the time of generator change or lead malfunction. Although data comparing both Sprint Fidelis® and Abbott Riata® leads in this setting is available, there are no multicenter comparative studies of outcomes for various lead management strategies, including lead extraction (LE), lead abandonment/revision (LA), and generator change (GC) only at the time of device at elective replacement interval (ERI) for Abbott Riata® leads. METHODS: A retrospective, multicenter study was undertaken to compare short-term outcomes (major complications-MC, death, extended or re-hospitalizations within 60 days-RH, lead malfunction-LM) and total outcomes (short-term outcomes & lead malfunction during follow-up) of patients with Riata® leads undergoing LE, LA, or GC. RESULTS: 152 patients (65 ± 13 years, 68% male) were followed for a mean 33 ± 30 months following intervention. Out of 166 procedures, 13 patients underwent LE, 16 patients underwent LA, and 137 patients underwent GC. There was 1 major complication in each group, yielding an event rate of 7.7% for LE, 6.3% for LA, and 0.7% for GC cohorts. There were significantly more short-term and total adverse outcomes in the group of patients getting LE and LA versus GC only (38.5% & 31.3% vs 7.3%, P < 0.001). Total Riata® lead dwell time follow-up was 17,067 months. A total of 3 Riata® lead malfunctions were noted during long-term follow-up. Inappropriate shocks were similar between LE 7.7% (1/13), LA 6.3% (1/16). and GC 11.0% (4/136); P = 0.57. CONCLUSIONS: There were more short-term and total adverse outcomes in more invasive management strategies (LE and LA) versus GC alone. The failure rate of Riata® leads was substantially lower compared to previous reports. Therefore, we recommend only performing battery exchange when a device with an active Riata® lead is at ERI, unless there is malfunction of the Riata® lead noted on testing. There were significantly more short-term adverse outcomes in the lead extraction (5/13) and lead abandonment/revision (5/16) groups than the generator only (8/137) group (P < 0.001). GIB - Gastrointestinal bleed, CHF - congestive heart failure, NSTEMI - non-ST elevation MI.

10.
J Arrhythm ; 39(5): 681-756, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37799799

RESUMO

Cardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing-induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre-procedure evaluation and preparation, implant procedure management, follow-up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified.

12.
Artigo em Inglês | MEDLINE | ID: mdl-37556090

RESUMO

BACKGROUND: Real-world data have suggested inconsistent adherence to oral anticoagulation for thromboembolic event (TE) prevention in patients with Non valvular atrial fibrillation (NVAF), yet it remains unclear if event risk is elevated during gaps of non-adherence. OBJECTIVE: To compare difference in outcomes between direct oral anticoagulant (DOAC) and warfarin based on adherence to the therapy in patients with NVAF. METHODS: Using the MarketScan claims data, patients receiving prescription of warfarin or a DOAC for NVAF from January 2015 to June 2016 were included. Outcomes included hospitalization for TE (ischemic stroke or systemic embolism), hemorrhagic stroke, stroke of any kind, and major bleeding. Event rates were reported for warfarin and DOACs at a higher-adherence proportion of days covered (PDC > 80%) and lower-adherence (PDC 40-80%). RESULTS: The cohort included 83,168 patients prescribed warfarin (51% [n = 42,639]) or DOAC (49% [n = 40,529]). Lower adherence occurred in 36% (n = 15,330) of patients prescribed warfarin and 26% (n = 10,956) prescribed DOAC. As compared to higher-adherence warfarin after multivariable adjustment, the risk of TE was highest in lower-adherence DOAC (HR 1.26; 95% CI, 1.14-1.33), and lowest in higher-adherence DOAC (HR, 0.93; 95% CI, 0.88-0.99). There was a significantly higher risk of hemorrhagic stroke and stroke of any kind in the lower-adherence groups. Major bleeding was more common with lower-adherence DOAC (HR, 1.43, 95% CI, 1.35-1.52) and lower-adherence warfarin (HR, 1.32, 95% CI, 1.26-1.39). CONCLUSIONS: In this large real-world study, low adherence DOAC was associated with higher risk of TE events as compared to high and low adherence warfarin.

13.
Curr Cardiol Rep ; 25(9): 925-940, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37530946

RESUMO

PURPOSE OF REVIEW: In this review, we aim to delve into the existing literature, seeking to uncover the mechanisms, investigate the electrocardiographic changes, and examine the treatment methods of various cardiac arrhythmias that occur after administration of the COVID-19 vaccine. RECENT FINDINGS: A global survey has exposed an incidence of arrhythmia in 18.27% of hospitalized COVID-19 patients. Furthermore, any type of COVID-19 vaccine - be it mRNA, adenovirus vector, whole inactivated, or protein subunit - appears to instigate cardiac arrhythmias. Among the cardiac adverse events reported post-COVID-19 vaccination, myocarditis emerges as the most common and is thought to be a potential cause of bradyarrhythmia. When a patient post-COVID-19 vaccination presents a suspicion of cardiac involvement, clinicians should perform a comprehensive history and physical examination, measure electrolyte levels, conduct ECG, and carry out necessary imaging studies. In our extensive literature search, we uncovered various potential mechanisms that might lead to cardiac conduction abnormalities and autonomic dysfunction in patients who have received the COVID-19 vaccine. These mechanisms encompass direct viral invasion through molecular mimicry/spike (S) protein production, an escalated inflammatory response, hypoxia, myocardial cell death, and the eventual scar/fibrosis. They correspond to a range of conditions including atrial tachyarrhythmias, bradyarrhythmia, ventricular arrhythmias, sudden cardiac death, and the frequently occurring myocarditis. For treating these COVID-19 vaccination-induced arrhythmias, we should incorporate general treatment strategies, similar to those applied to arrhythmias from other causes.


Assuntos
Arritmias Cardíacas , Vacinas contra COVID-19 , COVID-19 , Miocardite , Humanos , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/etiologia , Bradicardia/complicações , COVID-19/prevenção & controle , COVID-19/complicações , Vacinas contra COVID-19/efeitos adversos
14.
Curr Cardiol Rep ; 25(9): 909-915, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37584874

RESUMO

PURPOSE OF REVIEW: Left atrial appendage closure (LAAC) has shown to be non-inferior to oral anticoagulation (OAC) for non-valvular atrial fibrillation (AF). LAAC is now becoming a leading method for stroke prophylaxis in patients who have atrial fibrillation and are unable to tolerate OAC. There are currently two FDA-approved endocardial closure devices, namely, the Watchman FLX and Amplatzer Amulet. RECENT FINDINGS: Current data highlights that both devices offer similar efficacy and safety for LAAC. While the two devices differ in terms of intraprocedural complication rates, they offer similar short- to long-term outcomes in regard to peri-device leaks, device-related thrombosis, and mortality. With similar risk and safety profiles, both devices are indicated for patients who are unable to tolerate OAC. Newer clinical studies are directed to establish the efficacy of both devices as the primary method for stroke prevention in AF as an alternate to OAC.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Apêndice Atrial/cirurgia , Resultado do Tratamento , Procedimentos Cirúrgicos Cardíacos/métodos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/tratamento farmacológico , Anticoagulantes/uso terapêutico
16.
Int J Cardiol ; 391: 131257, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37574026

RESUMO

BACKGROUND: Hyperkalemia (HK) is a life-threatening condition that is frequently evaluated by electrocardiogram (ECG). ECG changes in severe HK (≥ 6.3 mEq/L) are not well-characterized. This study sought to compare and correlate ECG metrics in severe HK to baseline normokalemic ECGs and serum potassium. METHODS: A retrospective analysis of 340 severe HK encounters with corresponding normokalemic ECGs was performed. RESULTS: Various ECG metrics were analyzed. P wave amplitude in lead II, QRS duration, T wave slope, ratio of T wave amplitude: duration, and ratios of T wave: QRS amplitudes were significantly different between normokalemic and HK ECGs. P wave amplitude attenuation in lead II correlated better with serum potassium than in V1. T wave metrics that incorporated both T wave and QRS amplitudes correlated better than metrics utilizing T wave metrics alone. CONCLUSION: Multiple statistically significant and quantifiable differences among ECG metrics were observed between normokalemic and HK ECGs and correlated with increasing degrees of serum potassium and along the continuum of serum potassium. When incorporated into a logistic regression model, the ability to distinguish HK versus normokalemia on ECG improved significantly. These findings could be integrated into an ECG acquisition system that can more accurately identify severe HK.

17.
J Cardiovasc Electrophysiol ; 34(9): 1961-1968, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37449437

RESUMO

INTRODUCTION: Insertable cardiac monitors (ICMs) are commonly used to diagnose cardiac arrhythmias. False detections in the latest ICM systems remain an issue, primarily due to inaccurate R-wave sensing. New discrimination algorithms were developed and tested to reduce false detections of atrial fibrillation (AF), pause, and tachycardia episodes in ICMs. METHODS: Stored electrograms (EGMs) of AF, pause, and tachycardia episodes detected by Abbott Confirm Rx™ ICMs were extracted from the Merlin.net™ Patient Care Network, and manually adjudicated to establish independent training and testing datasets. New discrimination algorithms were developed to reject false episodes due to inaccurate R-wave sensing, P-wave identification, and R-R interval patterns. The performance of these new algorithms was quantified by false positive reduction (FPR) and true positive maintenance (TPM), relative to the existing algorithms. RESULTS: The new AF detection algorithm was trained on 5911 EGMs from 744 devices, resulting in 66.9% FPR and 97.8% TPM. In the testing data set of 1354 EGMs from 119 devices, this algorithm achieved 45.8% FPR and 97.0% TPM. The new pause algorithm was trained on 7178 EGMs from 1490 devices, resulting in 70.9% FPR and 98.7% TPM. In the testing data set of 1442 EGMs from 340 devices, this algorithm achieved 74.4% FPR and 99.3% TPM. The new tachycardia algorithm was trained on 520 EGMs from 204 devices, resulting in 57.0% FPR and 96.6% TPM. In the testing data set of 459 EGMs from 237 devices, this algorithm achieved 57.9% FPR and 96.5% TPM. CONCLUSION: The new algorithms substantially reduced false AF, pause, and tachycardia episodes while maintaining the majority of true arrhythmia episodes detected by the Abbott ICM algorithms that exist today. Implementing these algorithms in the next-generation ICM systems may lead to improved detection accuracy, in-clinic efficiency, and device battery longevity.


Assuntos
Fibrilação Atrial , Eletrocardiografia Ambulatorial , Humanos , Eletrocardiografia Ambulatorial/métodos , Fibrilação Atrial/diagnóstico , Algoritmos , Síncope/diagnóstico
18.
Pacing Clin Electrophysiol ; 46(9): 1099-1108, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37428778

RESUMO

INTRODUCTION: New and persistent left bundle branch block (NP-LBBB) following Transcatheter Aortic Valve Replacement (TAVR) is an ongoing concern with incidence ranging from as low as 4% to up to 65% (varying for different types of valves). Such patients are at risk of developing high-grade atrioventricular block (HAVB) warranting permanent pacemaker (PPM) implantation. However, currently, there are no consensus guidelines or large prospective studies to risk stratify these patients for safer discharge after TAVR. OBJECTIVES: To provide insight from a single center study on using modified electrophysiology (EP) study to risk stratify post-TAVR patients to outpatient monitoring for low-risk versus pacemaker implantation for high-risk patients. METHODS AND RESULTS: Between June 2020 and March 2023, all patients who underwent a TAVR procedure (324 patients) at our institution were screened for development of NP-LBBB post-operatively. Out of 26 patients who developed NP-LBBB, after a pre-specified period of observation, 18 patients were deemed eligible for a modified EP study to assess His-Ventricular (HV) interval. 11 out of 18 patients (61.1%) had normal HV interval (HV < 55 ms). Three out of 18 patients (16.7%) had HV prolongation (55 ms < HV < 70 ms) without significant HV prolongation (defined as an increase in HV interval > 30%) with intra-procedural procainamide challenge. Four out of 18 patients (22.2%) had significant HV prolongation (HV > 70 ms) warranting PPM implantation based on a multidisciplinary approach and shared decision-making with the patients. Total of 50% of patients discharged with PPM (two out of four patients) were noted to be pacemaker dependent based on serial device interrogations. All patients who did not receive PPM were discharged with ambulatory monitoring with 30-day event monitor and did not develop HAVB on serial follow-up. CONCLUSION: Normal HV interval up to 55 ms on modified EP study after TAVR and development of NP-LBBB can be utilized as a threshold for risk stratification to facilitate safe discharge. The optimal upper limit of HV interval threshold remains unclear in determining appropriate candidacy for PPM.


Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Projetos Piloto , Estudos Prospectivos , Resultado do Tratamento , Fatores de Risco , Arritmias Cardíacas/etiologia , Marca-Passo Artificial/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia
19.
Heart Rhythm ; 20(9): e17-e91, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37283271

RESUMO

Cardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing-induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre-procedure evaluation and preparation, implant procedure management, follow-up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Criança , Humanos , Fascículo Atrioventricular , Resultado do Tratamento , Doença do Sistema de Condução Cardíaco , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Eletrocardiografia/métodos
20.
Heart Rhythm O2 ; 4(6): 374-381, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37361614

RESUMO

Background: Remote monitoring (RM) has been accepted as a standard of care for follow-up of patients with cardiac implantable electronic devices (CIEDs). However, the resulting data deluge poses major challenge to device clinics. Objective: This study aimed to quantify the data deluge from CIED and stratify these data based on clinical relevance. Methods: The study included patients from 67 device clinics across the United States being remotely monitored by Octagos Health. The CIEDs included implantable loop recorders, pacemakers, implantable cardioverter-defibrillators, cardiac resynchronization therapy defibrillators, and cardiac resynchronization therapy pacemakers. Transmissions were either dismissed before reaching the clinical practice if they were repetitive or redundant or were forwarded if they were either clinically relevant or actionable transmission (alert). The alerts were further classified as level 1, 2, or 3 based on clinical urgency. Results: A total of 32,721 patients with CIEDs were included. There were 14,465 (44.2%) patients with pacemakers, 8381 (25.6%) with implantable loop recorders, 5351 (16.4%) with implantable cardioverter-defibrillators, 3531 (10.8%) with cardiac resynchronization therapy defibrillators, and 993 (3%) with cardiac resynchronization therapy pacemakers. Over a period of 2 years of RM, 384,796 transmissions were received. Of these, 220,049 (57%) transmissions were dismissed, as they were either redundant or repetitive. Only 164,747 (43%) transmissions were transmitted to the clinicians, of which only 13% (n = 50,440) had clinical alerts, while 30.6% (n = 114,307) were routine transmissions. Conclusion: Our study shows that data deluge from RM of CIEDs can be streamlined by utilization of appropriate screening strategies that will enhance efficiency of device clinics and provide better patient care.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...