Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(1)2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38204114

RESUMO

This paper presents the results of inspecting tensile stress-loaded GFRP (glass fiber-reinforced polymer) samples using the Magnetic Recording Method (MRM). The MRM can be utilized solely to examine ferromagnetic materials. The modification was proposed in order to examine nonmagnetic composites. Ferromagnetic strips made of low-carbon steel DC01 were bonded to the surface using an adhesive composed of epoxy resin with the addition of triethylenetetramine. The modified method's feasibility was tested on six samples made of GFRP. The research procedure consisted of three steps. In the first step, a metal strip is glued at the top surface of each sample, and an array of 100 cylindrical permanent magnets is used to record a sinusoidal magnetic pattern on the strip. The initial residual magnetization is measured in the second step, and the samples are subjected to static stress. In the third step, the residual magnetization is measured one more time. Ultimately, the measurement results from the second and third steps are compared. Generally, the applied stress causes changes in the amplitude and frequency of the sinusoidal magnetization pattern. In the case of GFRP, the frequency changes have not been used for evaluation due to minimal variations. The statistical parameters (mean, median, max, and mode) of the RMS (root mean square) value of the sinusoidal pattern were calculated and analyzed. The analysis demonstrates that the modified method is suitable for providing unequivocal and exact information on the load applied to a nonmagnetic composite material. For the presented results, the applied load can be assessed unambiguously for the samples elongated up to 0.6%.

2.
Int J Mol Sci ; 23(13)2022 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-35806067

RESUMO

The presented research focuses on the synthesis and structure-properties relationship of poly(carbonate-urea-urethane) (PCUU) systems including investigations on shape-memory effect capability. Furthermore, we approached the topic from a broader perspective by conducting extensive analysis of the relationship between the synthesized compounds and the results of computer simulations by means of the Monte Carlo method. For the first time, by using a unique simulation tool, the dynamic lattice liquid model (DLL), all steps of multi-step synthesis of these materials were covered by the simulations. Furthermore, broad thermal, mechanical, and thermomechanical characterization of synthesized PCUUs was performed, as well as determining the shape-memory properties. PCUUs exhibited good mechanical properties with a tensile strength above 20 MPa, elongation at break around 800%, and an exhibited shape-memory effect with shape fixity and shape recovery ratios above 94% and 99%, respectively. The dynamic lattice liquid model was employed to show the products and their molar mass distribution, as well as monomer conversion or the dispersity index for individual reaction steps. The results obtained in the following manuscript allow the planning of syntheses for the PCUUs of various structures, including crosslinked and soluble systems, which can provide a broad variety of applications of these materials, as well as a better understanding of the composition-properties relationship.


Assuntos
Materiais Biocompatíveis , Poliuretanos , Materiais Biocompatíveis/química , Simulação por Computador , Teste de Materiais , Poliuretanos/química , Resistência à Tração
3.
Materials (Basel) ; 15(2)2022 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-35057347

RESUMO

This paper proposes and experimentally investigates a novel nondestructive testing method for ferromagnetic elements monitoring, the Magnetic Recording Method (MRM). In this method, the inspected element must be magnetized in a strictly defined manner before operation. This can be achieved using an array of permanent magnets arranged to produce a quasi-sinusoidal magnetization path. The magnetic field caused by the original residual magnetization of the element is measured and stored for future reference. After the operation or loading, the magnetic field measurement is repeated. Analysis of relative changes in the magnetic field (for selected components) allows identifying applied stress. The proposed research methodology aims to provide information on the steel structure condition unambiguously and accurately. An interpretation of the results without referring to the original magnetization is also possible but could be less accurate. The method can be used as a standard technique for NDT (Non-Destructive Testing) or in structural health monitoring (SHM) systems.

4.
Int J Mol Sci ; 22(19)2021 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-34639147

RESUMO

In this work, we verified the possibility of valorizing a major waste product of the potato starch industry, potato tuber juice (PJ). We obtained a cost-effective, ecological-friendly microbiological medium that yielded bacterial cellulose (BC) with properties equivalent to those from conventional commercial Hestrin-Schramm medium. The BC yield from the PJ medium (>4 g/L) was comparable, despite the lack of any pre-treatment. Likewise, the macro- and microstructure, physicochemical parameters, and chemical composition showed no significant differences between PJ and control BC. Importantly, the BC obtained from PJ was not cytotoxic against fibroblast cell line L929 in vitro and did not contain any hard-to-remove impurities. The PJ-BC soaked with antiseptic exerted a similar antimicrobial effect against Staphylococcus aureus and Pseudomonas aeruginosa as to BC obtained in the conventional medium and supplemented with antiseptic. These are very important aspects from an application standpoint, particularly in biomedicine. Therefore, we conclude that using PJ for BC biosynthesis is a path toward significant valorization of an environmentally problematic waste product of the starch industry, but also toward a significant drop in BC production costs, enabling wider application of this biopolymer in biomedicine.


Assuntos
Bactérias/metabolismo , Celulose/biossíntese , Análise Custo-Benefício , Fibroblastos/metabolismo , Resíduos Industriais/economia , Solanum tuberosum/química , Animais , Celulose/economia , Meios de Cultura , Sucos de Frutas e Vegetais/análise , Camundongos , Amido/química
5.
Polymers (Basel) ; 13(2)2021 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-33477813

RESUMO

The paper presents the current volume of international production and global markets of carbon fiber reinforced polymer composites, also regarding the potential development trends. Examples were provided on how to effectively recycle carbon fiber reinforced polymer composites. Legally binding legislation in the EU on polymer composite recycling was given.

6.
Polymers (Basel) ; 13(3)2021 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-33513765

RESUMO

A series of poly(hexamethylene 2,5-furanodicarboxylate)-block-poly(tetrahydrofuran) (PHF-b-F-pTHF) copolymers were synthesized using a two-stage procedure, employing transesterification and polycondensation. The content of pTHF flexible segments varied from 25 to 75 wt.%. 1H nuclear magnetic resonance (NMR) and Fourier transformed infrared spectroscopy (FTIR) analyses were applied to confirm the molecular structure of the materials. Differential scanning calorimetry (DSC), dynamic mechanical measurements (DMTA), and X-ray diffraction (XRD) allowed characterizing the supramolecular structure of the synthesized copolymers. SEM analysis was applied to show the differences in the block copolymers' morphologies concerning their chemical structure. The influence of the number of flexible segments in the copolymers on the phase transition temperatures, thermal properties, as well as the thermo-oxidative and thermal stability was analyzed. TGA analysis, along with tensile tests (static and cyclic), confirmed the utilitarian performance of the synthesized bio-based materials. It was found that an increase in the amount of pTHF caused the increase of both number-average and weight-average molecular weights and intrinsic viscosities, and at the same time causing the shift of the values of phase transition temperatures toward lower ones. Besides, PHF-b-F-pTHF containing 75 wt.% of F-pTHF units was proved to be a promising thermoplastic shape memory polymer (SMP) with a switching temperature of 20 °C.

7.
Polymers (Basel) ; 12(12)2020 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-33339281

RESUMO

The paper presents some examples of new technological solutions for the recovery and re-use of recycled carbon fiber in automotive and railway industries, as well as in aviation and wind turbine constructions. The new technologies of fiber recovery that are described can enable the mass-scale use of recycled carbon fiber in the future.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA