1.
Innovations (Phila) ; 11(6): 400-406, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27930604

RESUMO

OBJECTIVE: Mitral valve (MV) chordae replacements can be technically challenging. Technology that remotely delivers and accurately secures artificial chordae may reduce the learning curve and improve the reliability of MV repairs. METHODS: The technology involved two devices: a remote suturing device for delivery of expanded polytetrafluoroethylene (ePTFE) suture to the papillary muscle and a Coaxial titanium suture fastener (TF) device with integrated saline infusion for real-time determination of chordae length during fixation. A mechanical model simulating MV chordae tension in a beating heart quantified the durability of 120 coaxially fastened ePTFE sutures using TF over time. Investigation of the technology was performed in ex vivo porcine, ovine, and in situ cadaver hearts, whereas live-tissue testing was conducted in a survivor ovine model. Mitral valve repair procedures involved the iatrogenic induction of mitral regurgitation by the resection of one to two native MV chordae, followed by implantation of ePTFE suture using the technology. Epicardial echocardiography, saline infusion testing, and histologic analysis evaluated MV competence, repair integrity, and long-term healing. RESULTS: Durability testing of ePTFE suture secured with TF demonstrated no degradation of TF pull-apart forces of for 440 million cycles. Mitral valve repairs using the technology were performed in eight sheep; four demonstrating proof of concept and four survived for an average of 6.5 months after completion of the procedure. At reoperation, echocardiography demonstrated trace to no mitral regurgitation with near complete endothelialization of the TF and artificial chordae. CONCLUSIONS: This technology successfully enabled the implantation of artificial chordae while providing real-time adjustment of chordae length during MV repair. These results encourage further investigation of its use clinically.


Assuntos
Procedimentos Cirúrgicos Cardíacos/instrumentação , Cordas Tendinosas/cirurgia , Valva Mitral/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Animais , Cadáver , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Modelos Biológicos , Politetrafluoretileno , Reprodutibilidade dos Testes , Ovinos , Técnicas de Sutura/estatística & dados numéricos , Suínos
2.
Innovations (Phila) ; 11(5): 327-336, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27561176

RESUMO

OBJECTIVE: Prostheses attachment is critical in aortic valve replacement surgery, yet reliable prosthetic security remains a challenge. Accurate techniques to analyze prosthetic fixation pressures may enable the use of fewer sutures while reducing the risk of paravalvular leaks (PVL). METHODS: Customized digital thin film pressure transducers were sutured between aortic annulus models and 21-mm bioprosthetic valves with 15 × 4-mm, 12 × 4-mm, or 9 × 6-mm-wide pledgeted mattress sutures. Simulating open and minimally invasive access, 4 surgeons, blinded to data acquisition, each secured 12 valves using manual knot-tying (hand-tied [HT] or knot-pusher [KP]) or automated titanium fasteners (TFs). Real-time pressure measurements and times were recorded. Two-dimensional (2D) and 3D pressure maps were generated for all valves. Pressures less than 80 mm Hg were considered at risk for PVL. RESULTS: Pressures under each knot (intrasuture) fell less than 80 mm Hg for 12 of 144 manual knots (5/144 HT, 7/144 KP) versus 0 of 288 TF (P < 0.001). Pressures outside adjacent sutures (extrasuture) were less than 80 mm Hg in 10 of 60 HT, zero of 60 KP, and zero of 120 TF sites for 15 × 4-mm valves; 17 of 48 HT, 25 of 48 KP, and 12 of 96 TF for 12 × 4-mm valves; and 15 of 36 HT, 17 of 36 KP, and 9 and 72 TF for 9 × 6-mm valves; P < 0.001 all manual versus TF. Annular areas with pressures less than 80 mm Hg ranged from 0% of the sewing-ring area (all open TF) to 31% (12 × 4 mm, KP). The average time per manual knot, 46 seconds (HT, 31 seconds; KP, 61 seconds), was greater than TF, 14 seconds (P < 0.005). CONCLUSIONS: Reduced operative times and PVL risk would fortify the advantages of surgical aortic valve replacement. This research encourages continued exploration of technical factors in optimizing prosthetic valve security.


Assuntos
Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese , Falha de Prótese , Técnicas de Sutura
3.
Innovations (Phila) ; 9(2): 111-6; discussion 116, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24755535

RESUMO

OBJECTIVE: This study compared the strength, consistency, and speed of prosthetic attachment sutures secured with automated fasteners with those of manual knots using an ex vivo porcine mitral valve annuloplasty model. A novel miniature pressure transducer system was developed to quantify pressures between sutured prosthetic rings and underlying cardiac tissue. METHODS: Sixteen mitral annuloplasty rings were sewn into ex vivo pig hearts. Eight rings were secured with the COR-KNOT device; and eight rings, with hand-tied knots using a knot pusher. A cardiac surgeon and a surgery resident each completed four manually tied rings and four COR-KNOT rings via a thoracotomy trainer. The total time to knot and cut each ring's sutures was recorded. Suture attachment pressures were measured within (intrasuture) and between (extrasuture) each suture loop using a 0.5 × 2.0-mm microtransducer probe system. RESULTS: The suture holding pressures for the COR-KNOT fasteners were significantly greater than for the manually tied knots (median, 1008.9 vs 415.8 mm Hg, P < 0.001). All automated fasteners measured greater than 500 mm Hg, whereas 56% of the hand-tied knots were less than 500 mm Hg, and 14% were less than 75 mm Hg. There was less variation in attachment pressures for the COR-KNOT fasteners than for the hand-tied knots (SD, 401.6 vs 499.3 mm Hg, P = 0.04). Significant time savings occurred with the use of the COR-KNOT compared with manual tying (12.4 vs 71.1 seconds per knot, P = 0.001). CONCLUSIONS: The novel microtransducer technology provided an innovative means of evaluating cardiac prosthetic anchoring sutures. In this model, mitral annuloplasty ring sutures secured with the COR-KNOT device were stronger, more consistent, and faster than with manually tied knots.


Assuntos
Automação/instrumentação , Educação Médica Continuada/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/educação , Anuloplastia da Valva Mitral/métodos , Técnicas de Sutura/educação , Técnicas de Sutura/instrumentação , Suturas , Animais , Simulação por Computador , Modelos Animais de Doenças , Desenho de Equipamento , Humanos , Suínos
4.
Innovations (Phila) ; 8(1): 50-5, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23571794

RESUMO

OBJECTIVE: A safe and reliable direct percutaneous approach for transapical access to the left ventricle would be a significant advance toward decreasing the invasiveness of intracardiac interventions. This report presents results from a surviving porcine beating heart model in which transapical access sites were closed using an automated suturing technique ultimately intended for percutaneous use. METHODS: Through an approved protocol including general anesthesia, the cardiac apex in 10 beating pig hearts was surgically exposed, permitting transapical passage of a 0.035-in guidewire and a 5.5F, 0.9-mL Fogarty balloon catheter. An automated suturing device was passed over the guidewire and the Fogarty onto the transapical access site. Two pledgeted horizontal mattress sutures were simultaneously placed concentrically around the apical access site with a single squeeze of the device's lever. A 25F dilator was passed into the left ventricle over the guidewire and subsequently removed. The sutures were then secured using pledgeted titanium knots. Chest wall and skin incisions were closed. The animals were recovered from anesthesia and resumed a normal diet. RESULTS: Under general anesthesia, the transapical access site of each animal was re-exposed, five at 1-week and five at 2-week intervals. Hemostasis was complete, and all wounds healed well. CONCLUSIONS: The evaluation of transapical wound closures in this surviving porcine heart model demonstrates complete hemostasis and excellent healing through the use of this automated remote suturing technology.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Ventrículos do Coração/cirurgia , Técnicas de Sutura/instrumentação , Cicatrização/fisiologia , Animais , Cateterismo Cardíaco/métodos , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Modelos Animais , Suturas , Suínos , Titânio