Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Plast Reconstr Surg ; 153(3): 568e-572e, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-37184506

RESUMO

SUMMARY: Fully implantable electronic devices in freely roaming animal models are useful in biomedical research, but their development is prohibitively resource intensive for many laboratories. The advent of miniaturized microcontrollers with onboard wireless data exchange capabilities has enabled cost-efficient development of myriad do-it-yourself electronic devices that are easily customizable with open-source software ( https://www.arduino.cc/ ). Likewise, the global proliferation of mobile devices has led to the development of low-cost miniaturized wireless power technology. The authors present a low-cost, rechargeable, and fully implantable electronic device comprising a commercially available, open-source, wirelessly powered microcontroller that is readily customizable with myriad readily available miniature sensors and actuators. The authors demonstrate the utility of this platform for chronic nerve stimulation in the freely roaming rat with intermittent wireless charging over 4 weeks. Device assembly was achieved within 2 hours and necessitated only basic soldering equipment. Component costs totaled $115 per device. Wireless data transfer and wireless recharging of device batteries was achieved within 30 minutes, and no harmful heat generation occurred during charging or discharging cycles, as measured by external thermography and internal device temperature monitoring. Wireless communication enabled triggered cathodic pulse stimulation of the facial nerve at various user-selected programmed frequencies (1, 5, and 10 Hz) for periods of 4 weeks or longer. This implantable electronic platform could be further miniaturized and expanded to study a vast array of biomedical research questions in live animal models. CLINICAL RELEVANCE STATEMENT: The clinical relevance of electrical stimulation in neural recovery remains controversial, and long-term neural stimulation in small animal models is challenging. We have developed a low-cost, fully implantable, wirelessly powered nerve stimulation device to facilitate further research in nerve stimulation in animal models.


Assuntos
Próteses e Implantes , Tecnologia sem Fio , Ratos , Animais , Desenho de Equipamento , Modelos Animais , Computadores de Mão
3.
Cell ; 186(7): 1382-1397.e21, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36958331

RESUMO

Suppressing sensory arousal is critical for sleep, with deeper sleep requiring stronger sensory suppression. The mechanisms that enable sleeping animals to largely ignore their surroundings are not well understood. We show that the responsiveness of sleeping flies and mice to mechanical vibrations is better suppressed when the diet is protein rich. In flies, we describe a signaling pathway through which information about ingested proteins is conveyed from the gut to the brain to help suppress arousability. Higher protein concentration in the gut leads to increased activity of enteroendocrine cells that release the peptide CCHa1. CCHa1 signals to a small group of dopamine neurons in the brain to modulate their activity; the dopaminergic activity regulates the behavioral responsiveness of animals to vibrations. The CCHa1 pathway and dietary proteins do not influence responsiveness to all sensory inputs, showing that during sleep, different information streams can be gated through independent mechanisms.


Assuntos
Nível de Alerta , Sono , Animais , Camundongos , Nível de Alerta/fisiologia , Transporte Biológico , Encéfalo/metabolismo , Peptídeos/farmacologia , Peptídeos/metabolismo , Sono/fisiologia , Intestinos/metabolismo
4.
Front Bioeng Biotechnol ; 9: 690905, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34552915

RESUMO

The rapid spread of COVID-19 and disruption of normal supply chains has resulted in severe shortages of personal protective equipment (PPE), particularly devices with few suppliers such as powered air-purifying respirators (PAPRs). A scarcity of information describing design and performance criteria for PAPRs represents a substantial barrier to mitigating shortages. We sought to apply open-source product development (OSPD) to PAPRs to enable alternative sources of supply and further innovation. We describe the design, prototyping, validation, and user testing of locally manufactured, modular, PAPR components, including filter cartridges and blower units, developed by the Greater Boston Pandemic Fabrication Team (PanFab). Two designs, one with a fully custom-made filter and blower unit housing, and the other with commercially available variants (the "Custom" and "Commercial" designs, respectively) were developed; the components in the Custom design are interchangeable with those in Commercial design, although the form factor differs. The engineering performance of the prototypes was measured and safety validated using National Institutes for Occupational Safety and Health (NIOSH)-equivalent tests on apparatus available under pandemic conditions at university laboratories. Feedback was obtained from four individuals; two clinicians working in ambulatory clinical care and two research technical staff for whom PAPR use is standard occupational PPE; these individuals were asked to compare PanFab prototypes to commercial PAPRs from the perspective of usability and suggest areas for improvement. Respondents rated the PanFab Custom PAPR a 4 to 5 on a 5 Likert-scale 1) as compared to current PPE options, 2) for the sense of security with use in a clinical setting, and 3) for comfort compared to standard, commercially available PAPRs. The three other versions of the designs (with a Commercial blower unit, filter, or both) performed favorably, with survey responses consisting of scores ranging from 3 to 5. Engineering testing and clinical feedback demonstrate that the PanFab designs represent favorable alternatives to traditional PAPRs in terms of user comfort, mobility, and sense of security. A nonrestrictive license promotes innovation in respiratory protection for current and future medical emergencies.

5.
medRxiv ; 2021 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-33821290

RESUMO

The rapid spread of COVID-19 and disruption of normal supply chains resulted in severe shortages of personal protective equipment (PPE), particularly devices with few suppliers such as powered air-purifying respirators (PAPRs). A scarcity of information describing design and performance criteria represents a substantial barrier to new approaches to address these shortages. We sought to apply open-source product development to PAPRs to enable alternative sources of supply and further innovation. We describe the design, prototyping, validation, and user testing of locally manufactured, modular, PAPR components, including filter cartridges and blower units, developed by the Greater Boston Pandemic Fabrication Team (PanFab). Two designs, one with a fully custom-made filter and blower unit housing, and the other with commercially available variants (the "Custom" and "Commercial" designs respectively) were developed. Engineering performance of the prototypes was measured and safety validated using NIOSH-equivalent tests on apparatus available under pandemic conditions, at university laboratories. Feedback on designs was obtained from four individuals, including two clinicians working in an ambulatory clinical setting and two research technical staff for whom PAPR use is a standard part of occupational PPE. Respondents rated the PanFab Custom PAPR a 4 to 5 on a 5 Likert-scale 1) as compared to current PPE options, 2) for the sense of security with use in a clinical setting, and 3) for comfort. The three other versions of the designs (with a commercial blower unit, filter, or both) performed favorably, with survey responses consisting of scores ranging from 3-5. Engineering testing and clinical feedback demonstrate that the PanFab designs represents favorable alternative PAPRs in terms of user comfort, mobility, and sense of security. A nonrestrictive license promotes innovation in respiratory protection for current and future medical emergencies.

6.
J Neurosci Methods ; 329: 108461, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31626845

RESUMO

BACKGROUND: Disease processes causing increased neural compartment pressure may induce transient or permanent neural dysfunction. Surgical decompression can prevent and reverse such nerve damage. Owing to insufficient evidence from controlled studies, the efficacy and optimal timing of decompression surgery remains poorly characterized for several entrapment syndromes. NEW METHOD: We describe the design, manufacture, and validation of a device for study of entrapment neuropathy in a small animal model. This device applies graded extrinsic pressure to a peripheral nerve and wirelessly transmits applied pressure levels in real-time. We implanted the device in rats applying low (under 100 mmHg), intermediate (200-300 mmHg) and high (above 300 mmHg) pressures to induce entrapment neuropathy of the facial nerve to mimic Bell's palsy. Facial nerve function was quantitatively assessed by tracking whisker displacements before, during, and after compression. RESULTS: At low pressure, no functional loss was observed. At intermediate pressure, partial functional loss developed with return of normal function several days after decompression. High pressure demonstrated complete functional loss with incomplete recovery following decompression. Histology demonstrated uninjured, Sunderland grade III, and Sunderland grade V injury in nerves exposed to low, medium, and high pressure, respectively. COMPARISON WITH EXISTING METHODS: Existing animal models of entrapment neuropathy are limited by inability to measure and titrate applied pressure over time. CONCLUSIONS: Described is a miniaturized, wireless, fully implantable device for study of entrapment neuropathy in a murine model, which may be broadly employed to induce various degrees of neural dysfunction and functional recovery in live animal models.


Assuntos
Paralisia de Bell/fisiopatologia , Modelos Animais de Doenças , Desenho de Equipamento , Nervo Facial/fisiopatologia , Síndromes de Compressão Nervosa/fisiopatologia , Animais , Paralisia de Bell/cirurgia , Descompressão Cirúrgica , Feminino , Síndromes de Compressão Nervosa/cirurgia , Pressão , Ratos
7.
Lab Chip ; 17(20): 3462-3473, 2017 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-28905952

RESUMO

Magnetic levitation is a technique for measuring the density and the magnetic properties of objects suspended in a paramagnetic field. We describe a novel magnetic levitation-based method that can specifically detect cell membrane-bound and soluble antigens by measurable changes in levitation height that result from the formation of antibody-coated bead and antigen complex. We demonstrate our method's ability to sensitively detect an array of membrane-bound and soluble antigens found in blood, including T-cell antigen CD3, eosinophil antigen Siglec-8, red blood cell antigens CD35 and RhD, red blood cell-bound Epstein-Barr viral particles, and soluble IL-6, and validate the results by flow cytometry and immunofluorescence microscopy performed in parallel. Additionally, employing an inexpensive, single lens, manual focus, wifi-enabled camera, we extend the portability of our method for its potential use as a point-of-care diagnostic assay.


Assuntos
Antígenos de Superfície/análise , Citometria de Fluxo/métodos , Separação Imunomagnética/métodos , Antígenos de Superfície/química , Antígenos Virais/química , Células Sanguíneas/química , Células Sanguíneas/citologia , Citometria de Fluxo/instrumentação , Humanos , Separação Imunomagnética/instrumentação , Interleucina-6/análise , Interleucina-6/química , Aplicativos Móveis , Smartphone
8.
Lab Chip ; 16(17): 3286-95, 2016 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-27431921

RESUMO

Magnetic levitation has emerged as a technique that offers the ability to differentiate between cells with different densities. We have developed a magnetic levitation system for this purpose that distinguishes not only different cell types but also density differences in cells of the same type. This small-scale system suspends cells in a paramagnetic medium in a capillary placed between two rare earth magnets, and cells levitate to an equilibrium position determined solely by their density. Uniform reference beads of known density are used in conjunction with the cells as a means to quantify their levitation positions. In one implementation images of the levitating cells are acquired with a microscope, but here we also introduce a cell phone-based device that integrates the magnets, capillary, and a lens into a compact and portable unit that acquires images with the phone's camera. To demonstrate the effectiveness of magnetic levitation in cell density analysis we carried out levitation experiments using red blood cells with artificially altered densities, and also levitated those from donors. We observed that we can distinguish red blood cells of an anemic donor from those that are healthy. Since a plethora of disease states are characterized by changes in cell density magnetic cell levitation promises to be an effective tool in identifying and analyzing pathologic states. Furthermore, the low cost, portability, and ease of use of the cell phone-based system may potentially lead to its deployment in low-resource environments.


Assuntos
Telefone Celular , Índices de Eritrócitos , Eritrócitos/citologia , Testes Hematológicos/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Modelos Biológicos , Fotografação , Anemia Ferropriva/sangue , Anemia Ferropriva/economia , Anemia Ferropriva/patologia , Telefone Celular/economia , Separação Celular/economia , Tamanho Celular , Custos e Análise de Custo , Custos Diretos de Serviços , Eritrócitos/química , Eritrócitos/patologia , Testes Hematológicos/economia , Hemoglobinas/análise , Humanos , Processamento de Imagem Assistida por Computador/economia , Fenômenos Magnéticos , Microscopia/economia , Fotografação/economia , Testes Imediatos/economia
9.
Opt Lett ; 31(13): 2039-41, 2006 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-16770425

RESUMO

We demonstrate continuous-wave cascaded optical parametric oscillation in which the signal field of the primary parametric oscillator internally pumps the secondary parametric oscillator. Wavelength tuning is achieved with temperature tuning and a fan-out grating structure of a dual-grating periodically poled lithium niobate crystal. Above the secondary threshold the primary signal power is clamped, and all the other output powers increase linearly with the input pump power, in accordance with theory. Cascaded parametric oscillation offers a convenient and efficient way to generate multiple tunable outputs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...