Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(12)2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37420569

RESUMO

In the paper, the effect of spontaneous Brillouin scattering (SpBS) is analyzed as a noise source in distributed acoustic sensors (DAS). The intensity of the SpBS wave fluctuates over time, and these fluctuations increase the noise power in DAS. Based on experimental data, the probability density function (PDF) of the spectrally selected SpBS Stokes wave intensity is negative exponential, which corresponds to the known theoretical conception. Based on this statement, an estimation of the average noise power induced by the SpBS wave is given. This noise power equals the square of the average power of the SpBS Stokes wave, which in turn is approximately 18 dB lower than the Rayleigh backscattering power. The noise composition in DAS is determined for two configurations, the first for the initial backscattering spectrum and the second for the spectrum in which the SpBS Stokes and anti-Stokes waves are rejected. It is established that in the analyzed particular case, the SpBS noise power is dominant and exceeds the powers of the thermal, shot, and phase noises in DAS. Accordingly, by rejecting the SpBS waves at the photodetector input, it is possible to reduce the noise power in DAS. In our case, this rejection is carried out by an asymmetric Mach-Zehnder interferometer (MZI). The rejection of the SpBS wave is most relevant for broadband photodetectors, which are associated with the use of short probing pulses to achieve short gauge lengths in DAS.


Assuntos
Fertilização , Frequência Cardíaca , Funções Verossimilhança
2.
Sensors (Basel) ; 22(23)2022 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-36502184

RESUMO

A simple and cost-effective architecture of a distributed acoustic sensor (DAS) or a phase-OTDR for engineering geology is proposed. The architecture is based on the dual-pulse acquisition principle, where the dual probing pulse is formed via an unbalanced Michelson interferometer (MI). The necessary phase shifts between the sub-pulses of the dual-pulse are introduced using a 3 × 3 coupler built into the MI. Laser pulses are generated by direct modulation of the injection current, which obtains optical pulses with a duration of 7 ns. The use of an unbalanced MI for the formation of a dual-pulse reduces the requirements for the coherence of the laser source, as the introduced delay between sub-pulses is compensated in the fiber under test (FUT). Therefore, a laser with a relatively broad spectral linewidth of about 1 GHz can be used. To overcome the fading problem, as well as to ensure the linearity of the DAS response, the averaging of over 16 optical frequencies is used. The performance of the DAS was tested by recording a strong vibration impact on a horizontally buried cable and by the recording of seismic waves in a borehole in the seabed.


Assuntos
Engenharia , Geologia , Análise Custo-Benefício , Frequência Cardíaca , Acústica
3.
Sensors (Basel) ; 22(3)2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35161779

RESUMO

This work presents a detailed review of the development of distributed acoustic sensors (DAS) and their newest scientific applications. It covers most areas of human activities, such as the engineering, material, and humanitarian sciences, geophysics, culture, biology, and applied mechanics. It also provides the theoretical basis for most well-known DAS techniques and unveils the features that characterize each particular group of applications. After providing a summary of research achievements, the paper develops an initial perspective of the future work and determines the most promising DAS technologies that should be improved.


Assuntos
Acústica , Tecnologia de Fibra Óptica , Humanos
4.
Anal Methods ; 13(21): 2424-2433, 2021 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-33998615

RESUMO

Hepatitis B surface antigen (HBsAg) is the most clinically relevant serological marker of hepatitis B virus (HBV) infection. Its detection in blood is extremely important for identification of asymptomatic individuals or chronic HBV carriers, screening blood donors, and early seroconversion. Rapid point-of-care HBsAg tests are predominantly qualitative, and their analytical sensitivity does not meet the requirements of regulatory agencies. We present a highly sensitive lateral flow assay based on superparamagnetic nanoparticles for rapid quantification (within 30 min) of polyvalent HBsAg in serum. The demonstrated limit of detection (LOD) of 80 pg mL-1 in human serum is better than both the FDA recommendations for HBsAg assays (which is 0.5 ng mL-1) and the sensitivity of traditional laboratory-based methods such as enzyme linked immunosorbent assays. Along with the attractive LOD at lower concentrations and the wide linear dynamic range of more than 2.5 orders, the assay features rapidity, user-friendliness, on-site operation and effective performance in the complex biological medium. These are due to the combination of the immunochromatographic approach with a highly sensitive electronic registration of superparamagnetic nanolabels over the entire volume of a 3D test structure by their non-linear magnetization and selection of optimal antibodies by original optical label-free methods. The developed cost-efficient bioanalytical technology can be used in many socially important fields such as out-of-lab screening and diagnosis of HBV infection at a point-of-demand, especially in hard-to-reach or sparsely populated areas, as well as highly endemic regions.


Assuntos
Antígenos de Superfície da Hepatite B , Vírus da Hepatite B , Anticorpos Anti-Hepatite B , Vírus da Hepatite B/genética , Humanos , Nanopartículas Magnéticas de Óxido de Ferro , Sensibilidade e Especificidade
5.
Anal Bioanal Chem ; 407(14): 3955-64, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25757827

RESUMO

A 3-channel biosensor based on spectral correlation interferometry (SCI) has been adapted for direct optical detection of antigens by measuring changes in thickness of a biolayer on functionalized glass slips employed as affordable single-use sensor chips. The instrument is insensitive to the bulk refractive index of a solution under test and provides signals in metrological units (pm or nm). Using real-time monitoring with the SCI, protocols for fabrication of sensor chips with different functional (epoxylated, carboxylated, and biotinylated) surfaces for antibody immobilization have been developed and optimized to minimize chip-to-chip variations and achieve better limit of detection (LOD), shorter assay time, and longer shelf life. The optimized coupling surfaces have been compared for detection of human serum albumin (HSA) used as a model agent of medical significance. The dynamic ranges for measuring the HSA concentration were 0.07-20, 0.12-30, and 0.25-10 µg/ml, and the assay durations were less than 20, 15, and 30 min for the epoxylated, carboxylated, and biotinylated chips, respectively. The advantages of each type of sensor chip have been shown, namely, the carboxylated chips feature the shortest assay time, the epoxylated ones demonstrate the best LOD, and the biotinylated chips exhibit the longest shelf life in an unprotected environment. The developed protocols of antibody immobilization can be used in different biosensors and assay techniques including those based on fluorescent, magnetic or plasmonic labels, etc. The SCI is well compatible with various partially transparent layers used in biosensing and with microarrays for multi-analyte detection.


Assuntos
Anticorpos Imobilizados , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Interferometria/métodos , Albumina Sérica/química , Humanos , Interferometria/instrumentação , Dispositivos Lab-On-A-Chip , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...