Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
1.
Cells ; 13(9)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38727286

RESUMO

The aim of this study was to review the current literature regarding the effects of intra-articularly applied, fat-derived orthobiologics (FDO) in the treatment of primary knee osteoarthritis over a mid-term follow-up period. A systematic literature search was conducted on the online databases of Scopus, PubMed, Ovid MEDLINE, and Cochrane Library. Studies investigating intra-articularly applied FDO with a minimum number of 10 knee osteoarthritis patients, a follow-up period of at least 2 years, and at least 1 reported functional parameter (pain level or Patient-Reported Outcome Measures) were included. Exclusion criteria encompassed focal chondral defects and techniques including additional arthroscopic bone marrow stimulation. In 28 of 29 studies, FDO showed a subjective improvement in symptoms (pain and Patient-Reported Outcome Measures) up to a maximum follow-up of 7.2 years. Radiographic cartilage regeneration up to 3 years postoperatively, as well as macroscopic cartilage regeneration investigated via second-look arthroscopy, may corroborate the favorable clinical findings in patients with knee osteoarthritis. The methodological heterogeneity in FDO treatments leads to variations in cell composition and represents a limitation in the current state of knowledge. However, this systematic review suggests that FDO injection leads to beneficial mid-term results including symptom reduction and preservation of the affected joint in knee osteoarthritis patients.


Assuntos
Osteoartrite do Joelho , Humanos , Osteoartrite do Joelho/terapia , Osteoartrite do Joelho/patologia , Transplante Autólogo , Tecido Adiposo , Injeções Intra-Articulares , Resultado do Tratamento
2.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1308-1316, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38504506

RESUMO

PURPOSE: The aim of this study was to analyse the functional outcome and the conversion rate to total knee arthroplasty (TKA) after surgically treated tibial plateau fractures (TPF). METHODS: All patients undergoing surgical treatment of TPF at a single institution between January 2003 and December 2019 were retrospectively reviewed. The Knee injury and Osteoarthritis Outcome Score (KOOS) and Tegner activity scale (TAS) were collected. The conversion rate to TKA was examined 2, 5, 7 and 10 years after surgical treatment of TPF. RESULTS: Ninety-four patients, with a mean follow-up of 110.6 months (±60.0), were included in the functional outcome assessment. Mean KOOS scores were 75.4 for symptoms, 80.6 for pain, 84.3 for activities of daily living (ADL), 59.5 for sports and 61.3 for QOL. All subscales were significantly lower on the injured side compared with the contralateral leg. Lower KOOS was observed in patients with hardware removal and Schatzker type 5 and 6 injuries. Median TAS was postinjury (4) significantly lower than preinjury (5) (p < 0.001). The conversion rate to TKA was 6.3%, 10.9%, 11.7% and 12.2% after 2,5,7 and 10 years of follow-up, respectively. Patients undergoing TKA were older than patients with no conversion to TKA (2 years follow-up 53.8 vs. 64.5 years, p = 0.026). CONCLUSION: TPFs decrease the function of the knee when compared with the contralateral side and to the preoperative condition. Bicondylar fractures are associated with worse functional outcomes. A conversion rate to TKA of 12.2% was found at 10 years follow-up. LEVEL OF EVIDENCE: Level III.


Assuntos
Artroplastia do Joelho , Fraturas da Tíbia , Humanos , Feminino , Masculino , Fraturas da Tíbia/cirurgia , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Atividades Cotidianas , Adulto , Resultado do Tratamento , Recuperação de Função Fisiológica , Fraturas do Planalto Tibial
3.
Sci Rep ; 14(1): 1154, 2024 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-38212361

RESUMO

Modern cementless short stems in total hip arthroplasty (THA) enable a precise reconstruction of the native pre-arthritic hip geometry. While gender differences have been reported for older generation straight hip stems, there are hardly reports regarding modern cementless short hip stems. Therefore, we aimed to evaluate the influence of gender differences in hip anatomy in cementless short stem THA. A total of 207 patients (109 females, 98 males) with unilateral THA and absence of contralateral joint space narrowing (Kellgren-Lawrence grade ≤ 2) were included. Acetabular height and offset as well as femoral height and offset were measured on pre- and 3-months-postoperative anteroposterior X-rays of the pelvis and compared to the contralateral hip. Additionally, implant position was evaluated on the postoperative radiograph. In male patients, the loss of acetabular offset was significantly greater than in females (p = 0.012), leading to a compensatory increase in femoral offset (p = 0.041). Femoral height discrepancy was significantly higher in females (p < 0.001), accounting for an increased global hip height discrepancy (p < 0.001). The mean acetabular anteversion was significantly greater in female patients (p < 0.001). Female patients are at higher risk of femoral lengthening in THA with a cementless short stem potentially caused by a further proximally conducted femoral neck osteotomy and show significantly higher cup anteversion angles. Therefore, surgeons should take special care to the level of neck resection and implant positioning in female patients.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Masculino , Feminino , Fatores Sexuais , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Acetábulo/cirurgia , Estudos Retrospectivos , Articulação do Quadril/cirurgia
4.
J Pediatr Orthop ; 44(3): 135-140, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38073187

RESUMO

INTRODUCTION: The Pavlik harness is a commonly used treatment for developmental dysplasia of the hip (DDH) of types IIc or worse, based on the Graf classification. This study aimed to assess the long-term follow-up outcomes after treating DDH with the Pavlik harness. METHODS: Between 1995 and 2006, ultrasound screening was conducted on 7372 newborns within the first days of life. Among them, 203 dysplastic hips in 152 patients, whose sonograms were Graf type IIc or worse, were treated with Pavlik harness. Treatment was discontinued if the measurement indicated Graf type Ia/b. More than 20 years later (mean: 20.46 y), patients were invited for clinical evaluation (Oxford Hips Score, Schulthess Hip Score, Harris Hip Score) and radiologic examination (center-edge angle according to Wiberg and the Severis classification, the rate of roofing of the femoral head via the Reimers migration percentage, and the Sharp angle). RESULTS: Of the 152 patients, 60 (39.5%) participants with 80 (39.4%) affected hips (57.7% type IIc, 7.9% type D, and 15.6% type IIIa/b) were reexamined. The average follow-up duration was 20.5 years, with a maximum of 25.9 years. According to the Severin's classification, only 2 (3.77%) patients, each with one affected hip, showed slight residual dysplasia. The Reimer's migration percentage indicated an average of almost 90% canopy cover in the patient collective studied. No avascular necrosis was found, and the Sharp angle showed an average of almost 38 degrees. Only 4 participants with each one affected hip showed residual dysplasia according to the Sharp angle. The clinical results were quite satisfying, as none of the patients experienced hip pain that significantly limited their everyday activities or sports engagement, requiring medical attention before this study.Conclusions:Conservative therapy of DDH (Graf type IIc, D, III) with the Pavlik harness has demonstrated very good therapeutic success and a very low rate of residual dysplasia (2.81%). Both the radiologic and clinical outcomes were highly satisfactory. LEVEL OF EVIDENCE: Level IV.


Assuntos
Displasia do Desenvolvimento do Quadril , Luxação Congênita de Quadril , Humanos , Recém-Nascido , Lactente , Articulação do Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/terapia , Aparelhos Ortopédicos , Estudos Retrospectivos , Resultado do Tratamento , Ultrassonografia
5.
J Arthroplasty ; 39(1): 242-249.e2, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37380142

RESUMO

BACKGROUND: The aim of the present study was to compare causative bacteria and their antibiotic resistance profiles in patients developing a periprosthetic joint infection (PJI) based on preoperative prophylactic antibiotic regimens in primary total hip (THA) and primary total and unicompartmental knee arthroplasty (TKA/UKA). METHODS: We reviewed all cases of PJI occurring after primary THA and primary TKA/UKA, between 2011 and 2020 in a tertiary referral hospital. The standard preoperative prophylactic antibiotic for primary joint arthroplasty was cefuroxime and recommended second-line agent was clindamycin. Patients were divided by the replaced joint and analyzed independently. RESULTS: In the THA group, culture-positive PJI was detected in 61 of 3,123 (2.0%) cefuroxime-administered cases and 6 of 206 (2.9%) noncefuroxime-administered cases. In the TKA/UKA group, culture positive PJI was identified in 21 of 2,455 (0.9%) cefuroxime-administered cases and in 3 of 211 (1.4%) noncefuroxime administered cases. The most commonly isolated bacteria in both groups were coagulase negative staphylococci (CNS). There were no statistically significant differences of pathogen spectrum depending on the preoperative antibiotic regimen detected. Antibiotic resistance of isolated bacteria was significantly different in 4 of 27 (14.8%) analyzed antibiotics in THA and in 3 of 22 (13.6%) analyzed antibiotics in TKA/UKA. In all cohorts, a high occurrence of oxacillin-resistant CNS (50.0 to 100.0%) and clindamycin-resistant CNS (56.3 to 100.0%) has been observed. CONCLUSION: The use of the second-line antibiotic did not influence the pathogen spectrum or antibiotic resistance. However, an alarmingly high proportion of CNS strains was resistant to clindamycin.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Hipersensibilidade a Drogas , Hipersensibilidade , Infecções Relacionadas à Prótese , Humanos , Antibacterianos/uso terapêutico , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Cefuroxima , Clindamicina , Resistência Microbiana a Medicamentos , Hipersensibilidade/complicações , Hipersensibilidade/tratamento farmacológico , Medidas de Resultados Relatados pelo Paciente , Penicilinas , Infecções Relacionadas à Prótese/etiologia , Estudos Retrospectivos , Staphylococcus
6.
Bioengineering (Basel) ; 10(12)2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38135988

RESUMO

OBJECTIVES: As currently there is no existing biomechanical work on the topic of interest, the aim of the current study was to investigate the effect of cerclage banding distally to an intraoperatively occurring proximal periprosthetic femoral clamshell fracture versus a non-fractured femur after total hip arthroplasty. METHODS: A diaphyseal anchoring stem was implanted in twenty paired human cadaveric femora, assigned to a treatment and a control group. In the treatment group, each specimen was fitted with a cerclage band placed 3 mm distally to a clamshell fracture, created with an extent of 40% of the anchoring length of the stem. The resulting fragment was not treated further. The contralateral specimens were left with the stems without further fracture creation or treatment. All constructs were tested under progressively increasing cyclic axial loading until failure. Relative bone-implant movements were monitored by motion tracking. RESULTS: Number of cycles and the corresponding load at stem loosening, defined as 1 mm displacement of the stem along the shaft axis, were 31,417 ± 8870 and 3641.7 ± 887 N in the control group, and 26,944 ± 11,706 and 3194.4 ± 1170.6 N in the treatment group, respectively, with no significant differences between them, p = 0.106. CONCLUSION: From a biomechanical perspective, cerclage banding distally to an intraoperative clamshell fracture with an extent of 40% of the anchoring length of the stem demonstrated comparable resistance against hip stem loosening versus a non-fractured femur. It may therefore represent a valid treatment option to restore the full axial stability of a diaphyseal anchoring stem. In addition, it may be considered to keep the medial wall fragment unfixed, thus saving operative time and minimizing associated risks.

7.
Sci Rep ; 13(1): 19695, 2023 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-37951980

RESUMO

Short stems are associated with a significantly lower blood loss (BL) compared to straight stems in total hip arthroplasty (THA). Different types of stems differ in design, fixation and level of femoral neck osteotomy. Therefore, we sought to evaluate the difference regarding the perioperative BL between two short stems with different designs in direct anterior approach (DAA). A total of 187 THA performed by a single surgeon were analysed. 107 patients received a neck-resecting (Group A) and 80 patients a neck-sparing short stem (Group B). Blood counts of the day before surgery and of two days after surgery were evaluated. Total blood volume and BL were calculated. Additionally, duration of surgery was analysed. The perioperative BL was significantly lower in Group B (451.4 ± 188.4 ml) compared to Group A (546.6 ± 232.7 ml; p = 0.002). The postoperative haematocrit (31.6 ± 3.7% vs. 30.4 ± 4.4%; p = 0.049) and haemoglobin-level (11.0 ± 1.3 g/dL vs. 10.4 ± 1.5 g/dL; p = 0.002) were significantly higher in Group B. Duration of surgery was significantly shorter in Group B (62.0 ± 11.4 min vs. 72.6 ± 21.8 min; p < 0.001). The use of a neck-sparing short stem leads to a significantly decreased BL compared to a neck-resecting short stem in DAA THA. A less extensively conducted capsular release necessary for optimal femoral exposition might lead to a lower perioperative BL and shorter durations of surgery.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Hemorragia , Colo do Fêmur/cirurgia , Fêmur/cirurgia , Estudos Retrospectivos
8.
J Orthop Traumatol ; 24(1): 44, 2023 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-37592170

RESUMO

BACKGROUND: The Oxford Knee Score (OKS) has been designed for patients with knee osteoarthritis and has a widespread use. It has 12 questions, with each question having the same weight for the overall score. Some authors have observed a significant ceiling effect, especially when distinguishing slight postoperative differences. We hypothesized that each questions' weight will depend significantly on the patient's sociodemographic data and lifestyle. METHODS: In this international multicentric prospective study, we included patients attending a specialist outpatient knee clinic. Each patient filled out 3 questionnaires: (a) demographic data and data pertaining to the OKS, (b) the standard OKS, and (c) the patient gave a mark on the weight of the importance of each question, using a 5-point Likert scale (G OKS). Linear regression models were used for the analysis. RESULTS: In total 203 patients (106 female and 97 male) with a mean age of 64.5 (±12.7) years and a mean body mass index (BMI) of 29.34 (±5.45) kg/m2 were included. The most important questions for the patients were the questions for pain, washing, night pain, stability, and walking stairs with a median of 5. In the regression models, age, gender, and driving ability were the most important factors for the weight of each of the question. CONCLUSION: The questions in the OKS differ significantly in weight for each patient, based on sociodemographic data, such as age, self-use of a car, and employment. With these differences, the Oxford Knee Score might be limited as an outcome measure. Adjustment of the OKS that incorporates the demographic differences into the final score might be useful if the ceiling effect is to be mitigated. LEVEL OF EVIDENCE: Level II prospective prognostic study.


Assuntos
Emprego , Osteoartrite do Joelho , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Articulação do Joelho , Osteoartrite do Joelho/cirurgia , Dor
9.
JSES Int ; 7(1): 1-9, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36820431

RESUMO

Background: Stemless shoulder arthroplasty using 4 open-fin press-fit anchors has been showing promising short-term clinical and radiographic results for patients' primary osteoarthritis. This prospective, multicenter study presents 5-year postoperative clinical and radiological outcomes of a stemless shoulder arthroplasty for primary osteoarthritis. Methods: Between November 2012 and December 2015, 100 patients were treated for primary osteoarthritis with the Sidus stem-free shoulder system at 7 European centers. Clinical assessment included the Constant-Murley Score, American Shoulder and Elbow Standardized Shoulder Assessment Form score, Subjective Shoulder Value, and range of motion. True anteroposterior, axial and lateral radiographs were reviewed for osteolysis, glenoid and humerus loosening, heterotopic ossification, radiolucent lines, component migration and humeral bone resorption. In addition to a Kaplan-Meier survival analysis, a comparative analysis between total shoulder arthroplasty and hemiarthroplasty was performed. Results: Seventy-one patients (36 females) with a mean age of 63.8 years (range: 47-79 years) were available for the 5-year clinical and radiographic follow-up (range: 52-79 months). There was a significant increase (P < .0001) in all outcome scores compared to baseline values. Patients with total shoulder arthroplasty (n = 48) achieved significantly better functional outcome than patients with shoulder hemiarthroplasty (n = 23) with regard to the absolute and relative Constant-Murley Score, American Shoulder and Elbow Standardized Shoulder Assessment Form score, and Subjective Shoulder Value as well as greater abduction strength and range of motion in forward elevation and external rotation (P ≤ .004). There were no cases of osteolysis or humeral loosening. There were some cases of heterotopic ossification (1.4%), radiolucency around the humerus (1.4%) or glenoid (25%), glenoid migration (2.1%), inferior osteophytes (1.4%) or humerus bone resorption (9.9%). The 5-year survival was 94%. Conclusion: Patients treated with the Sidus stem-free shoulder system for primary osteoarthritis continue to achieve good clinical and radiographic results without any signs of aseptic humeral implant loosening at 5 years postsurgery.

10.
J Pers Med ; 13(2)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36836591

RESUMO

(1) Background: Magnesium-based implants use has become a research focus in recent years. Radiolucent areas around inserted screws are still worrisome. The objective of this study was to investigate the first 18 patients treated using MAGNEZIX® CS screws. (2) Methods: This retrospective case series included all 18 consecutive patients treated using MAGNEZIX® CS screws at our Level-1 trauma center. Radiographs were taken at 3-, 6- and 9-month follow-ups. Osteolysis, radiolucency and material failure were assessed, as were infection and revision surgery. (3) Results: Most patients (61.1%) had surgery in the shoulder region. Radiolucency regressed from 55.6% at 3-month follow-ups to 11.1% at 9-month follow-ups. Material failure occurred in four patients (22.22%) and infection occurred in two patients, yielding a 33.33% complication rate. (4) Conclusion: MAGNEZIX® CS screws demonstrated a high percentage of radiolucency that regressed and seems to be clinically irrelevant. The material failure rate and infection rate require further research.

11.
Medicina (Kaunas) ; 59(2)2023 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-36837521

RESUMO

Background and Objectives: Noise exposure during total knee arthroplasty (TKA) has been demonstrated to exceed thresholds that are deemed as over-exposure by industry noise level standards. With orthopedic surgeons being at risk of suffering from Noise Induced Hearing Loss, the purpose of this pilot study was to evaluate the viability of the use of industry grade active noise cancelling headphones (ANCH) during TKA. Material and Methods: In this prospective pilot study, 10 TKA were performed. In five of these cases, surgeon, assistant, scrub nurse and anesthetist wore ANCH with automatic noise level dependent noise attenuation above 82 dB. A validated 14-item questionnaire was used after each case to evaluate the quality of communication, performance, teamwork and mental load. In seven cases a calibrated sound level meter was used to measure the operating theatre noise. Peak sound level (LApeak), A-weighted continuous sound level (LAeq) and A-weighted noise exposure averaged for an 8-h time-period (LEPd) were calculated. Results: There was no perceived benefit of ANCH for the surgeons (p = 0.648), assistants (p = 0.908) and scrub nurses (p = 0.251). There was an overall improvement observed by anesthetists (p = 0.001). A worse communication while wearing ANCH was reported by surgeons but not by the rest of the team. Average LApeak was 90.6 ± 3.2 dB(C), LAeq was 61.9 ± 1.0 dB(A) and LEPd was 53.2 ± 1.2 dB(A). Conclusions: Industry grade ANCH seem to provide no benefit for surgeons, assistants and scrub nurses during TKA, while anesthesiologists seem to benefit from the use of ANCH during TKA. Due to the limitations of this pilot study, further studies with larger study populations are necessary to adequately investigate the use of ANCH during TKA.


Assuntos
Artroplastia do Joelho , Cirurgiões , Humanos , Projetos Piloto , Estudos Prospectivos , Ruído
12.
Arch Orthop Trauma Surg ; 143(8): 5405-5415, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36629904

RESUMO

INTRODUCTION: Increased risk of periprosthetic joint infection (PJI) in minimally invasive (MIS) total hip arthroplasty (THA) is still debated. This study aimed to identify differences in surgical and patient-related risk factors for PJI between an MIS anterolateral approach and transgluteal-modified Hardinge approach. METHODS: A retrospective cohort of 5315 THAs performed between 2006 and 2019 at a single institution was screened. Short stem THAs performed via an MIS anterolateral approach in the supine position and standard straight stem THAs performed via a transgluteal modified Hardinge approach were included. Propensity score matching was performed to control for selection bias. After matching, 1405 (34.3%) short stem THAs implanted via MIS anterolateral approach and 2687 (65.7%) straight stem THAs implanted via a transgluteal modified Hardinge approach were included. The risk of PJI due to patient-specific and surgical factors was retrospectively analyzed using chi-square test and multivariate regression analysis. RESULTS: PJI occurred in 1.1% in both MIS anterolateral and transgluteal approach (p = 0.823). Multivariate regression showed an increased infection risk for patients with a BMI between 35 and 39.99 kg/m2 (OR 6.696; CI 1.799-24.923; p = 0.005), which could not be demonstrated for transgluteal approach (OR 0.900; CI 0.900-4.144; p = 0.93). A BMI ≥ 40 kg/m2 (OR 14.150; CI 2.416-82.879; p = 0.003) was detected as a risk factor for PJI only in anterolateral approach. Increased operation time ≥ 121 min showed a significantly increased risk for PJI in the general cohort (OR 6.989; CI1.286-37.972; p = 0.024). CONCLUSION: Minimally invasive anterolateral and transgluteal THA show a comparable rate of early PJI within the first year of index surgery. A BMI of ≥ 35 kg/m2 was detected as a clear risk factor for infection in the anterolateral approach. Prolonged operation time ≥ 121 min increases the risk of PJI regardless of approach.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Prótese de Quadril , Infecções Relacionadas à Prótese , Humanos , Artroplastia de Quadril/efeitos adversos , Estudos Retrospectivos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Pontuação de Propensão , Prótese de Quadril/efeitos adversos , Fatores de Risco , Artrite Infecciosa/cirurgia
13.
J Arthroplasty ; 38(4): 751-756, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36283514

RESUMO

BACKGROUND: Recent studies indicate a decreased risk of periprosthetic femoral fractures (PFFs) in cementless total hip arthroplasty (THA) for short compared to straight stems. However, the results are still inconclusive. Therefore, we retrospectively investigated the rate of PFFs within the first year between cementless short and straight stem THA. METHODS: A 1:1 propensity score matching of 3,053 THAs was performed. Two groups including 1,147 short stem THAs implanted through a minimally invasive antero-lateral approach and 1,147 straight stem THAs implanted through a transgluteal Hardinge approach were matched. The rates of PFFs and fracture patterns were compared between both stem types. Risk factors for PFFs were analyzed by multivariate regression analyses. RESULTS: The overall rate of PFFs was 1.7% in short stem THA and 3.2% in straight stem THA (P = .015). Postoperatively detected Vancouver A fractures occurred significantly more often in straight stem THA (P = .002), while the occurrence Vancouver B fractures did not differ significantly (P = .563). The risk of PFFs was significantly increased for women in straight stem THA (Odds ratio (OR) 2.620; Confidence Interval (CI) 1.172-5.856; P = .019). Increasing age showed a significantly increased odds ratio in short stem (OR 1.103; CI 1.041-1.169, P < .001) and straight stem THA (OR 1.057; CI 1.014-1.101, P = .008). CONCLUSION: Short stem THA reduces Vancouver Type A PFFs in the trochanteric region compared to straight stem THA, while Vancouver Type B fractures are comparable. Increasing age is a significant risk factor for both stem types, while the risk for PFFs in women was only significantly increased in the straight stem group.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Feminino , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Pontuação de Propensão , Desenho de Prótese , Fraturas do Fêmur/cirurgia , Fraturas Periprotéticas/cirurgia , Fatores de Risco , Reoperação/efeitos adversos
14.
J Orthop Res ; 41(3): 641-648, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35735256

RESUMO

To biomechanically evaluate the stability of a diaphyseal anchored, cementless stem in presence of a proximal periprosthetic femoral medial wall defect compared to the stability of the same stem in an intact femur. Twenty-two paired human cadaveric femora were pairwise assigned either to a fracture group, featuring a proximal medial wall defect involving 40% of the stems medial anchorage distance, or a control group with native specimens. The specimens were tested under a monotonically increasing cyclic axial loading protocol. Load, cycles, and multiples of the respective body weight at implant loosening was measured. Mean initial stiffness was 2243.9 ± 467.9 N/mm for the intact group and 2190.1 ± 474.8 N/mm for the fracture group. Mean load to loosening in the intact group was 3210.5 ± 1073.2 N and 2543.6 ± 576.4 N in the fracture group, with statistical significance. Mean cycles to loosening in the intact group were 27104.9 ± 10731.7 and 20431.5 ± 5763.7 in the fracture group, with statistical significance. Mean multiples of the resulting body weight at loosening in the intact group was 548.3 ± 158.5% and 441.4 ± 104% in the fracture group, with statistical significance. A medial wall defect involving 40% of the medial anchorage distance significantly decreases the axial stability of a diaphyseal anchored stem. However, mechanical failure occurred beyond physiological stress. At loosening rates of about 4 multiples of the body weight in the fracture group, a "safe zone" remains of a 0.5-fold body weight for maximum loads and twofold body weights for average loads.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Artroplastia de Quadril/métodos , Desenho de Prótese , Fêmur/cirurgia , Reoperação , Fraturas do Fêmur/cirurgia
15.
Arch Orthop Trauma Surg ; 143(6): 3077-3084, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35849185

RESUMO

INTRODUCTION: The aim of the present study was to assess clinical outcome and mid-term survivorship of mobile-bearing unicompartmental knee arthroplasty in patients 50 years of age or younger. METHODS: This study reports the results of 119 patients (130 knees) following mobile-bearing medial UKA. Primary indication was advanced osteoarthritis or avascular necrosis of the femoral condyle. The anterior cruciate ligament (ACL) as well as the collateral ligaments were functionally intact, the varus deformity was manually correctable and there was no evidence of osteoarthritis in the lateral compartment. Survivorship analysis was performed with different endpoints and clinical outcome was measured using the Oxford Knee Score (OKS), American Knee Society Score and Functional Score (AKSS-O, AKSS-F), range of motion (ROM), Tegner activity score, University of California Los Angeles score (UCLA) and visual analogue scale for pain (VAS). RESULTS: The survival rate was 96.6% at 6.5 years (95% CI 98.7-91.3%; number at risk: 56) and 91.7% (95% CI 96.7-80%; number at risk: 22) at 10 years for the endpoint device related revisions and 91.5% at 6.5 years (95% CI 95.4-84.5%; number at risk: 56) and 86.8% (95% CI 93-76.2%; number at risk: 22) at 10 years for the endpoint revision for any reason. Outcome scores, VAS and ROM showed significant improvements (p < 0.001). The mean OKS increased from 26.7 (standard deviation (sd): 7.2) preoperatively to 40.9 (sd: 7.6) at final follow-up, the mean AKSS-O from 48.3 (sd: 13.3) to 87.8 (sd: 14.4) and the mean ROM from 118° (sd: 16.7) to 125° (sd: 11.4). The radiological analysis revealed progression of degenerative changes in the lateral compartment in 39.6% of patients without affecting the functional outcome. CONCLUSIONS: Medial mobile-bearing UKA is a viable surgical treatment option in young patients with significant improvements in knee function and pain. Further follow-up is necessary to evaluate the long-term efficacy. LEVEL OF EVIDENCE: Retrospective cohort study, Level III.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Prótese do Joelho/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Articulação do Joelho/cirurgia , Dor/etiologia , Seguimentos
16.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 760-767, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35864240

RESUMO

PURPOSE: The purpose of this study was to investigate the learning curve associated with robotic assisted knee arthroplasty (RAS KA). Therefore, the evaluation of the influence of an experienced surgeon on the overall team performance of three surgeons regarding the learning curve in RAS KA was investigated. It was hypothesized that the presence of an experienced surgeon flattens the learning curve and that there was no inflection point for the learning curve of the surgical team. METHODS: Fifty-five cases consisting of 31 total knee arthroplasties (TKA) and 24 unicompartmental arthroplasties (UKA) performed by three surgeons during 2021 were prospectively investigated. Single surgeon and team performance for operation time learning curve and inflection points were investigated using cumulative sum analysis (CUSUM). RESULTS: A downward trend line for individual surgeons and the team performance regarding the operation time learning curve was observed. No inflexion point was observed for the overall team performance regarding TKA and UKA. The surgeon that performed all cases with the assistance of the experienced surgeon had significantly shorter surgical times than the surgeon that only occasionally received assistance from the experienced surgeon (p = 0.004 TKA; p = 0.002 UKA). CONCLUSION: The presence of an experienced surgeon in robotically assisted knee arthroplasty can flatten the learning curve of the surgical team formerly unexperienced in robotic assisted systems. Manufacturers should provide expanded support during initial cases in centres without previous experience to robotic assisted knee arthroplasty. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Cirurgiões , Humanos , Curva de Aprendizado , Osteoartrite do Joelho/cirurgia , Articulação do Joelho/cirurgia , Resultado do Tratamento
17.
Arch Orthop Trauma Surg ; 143(1): 529-537, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35020039

RESUMO

PURPOSE: Varus positioning of the femoral stem can affect the hip offset (HO). The critical trochanter angle (CTA) was introduced in 2019 as a novel geometric angle, to predict varus stem alignment in cementless straight stem THA. The aim of this study was to evaluate the applicability of the CTA as a predictor for stem alignment in THA with a cementless neck resecting short stem. PATIENTS AND METHODS: In this retrospective study, 106 patients (index surgery 2014-2019) with unilateral THA and a morphologically healthy contralateral hip as a reference (Kellgren-Lawrence ≤ 1) were included. A cementless short stem with meta-diaphyseal fixation and press-fit cup was implanted in all cases. Stem alignment, CCD angle, CTA and offset reconstruction were measured on preoperative and 3 months postoperative AP radiographs of the pelvis. RESULTS: Preoperative lower CTA and lower CCD angle were positively correlated (r = 0.472; p < 0.001). Higher varus stem alignment is correlated with lower CTA (r = - 0.384; p < 0.001) and lower CCD angle (r = - 0.474; p < 0.001). A CTA of 23.1° or lower showed a sensitivity of 59.1% and a specificity of 87.1% (AUC: 0.733) and a CCD angle of 132.75° or lower a sensitivity of 68.2% and a specificity of 80.6% (AUC: 0.77) for a varus stem alignment > 3°. CONCLUSION: The CTA is also applicable in cementless THA with a neck resecting short stem to evaluate risk of intraoperative varus stem positioning. The CCD angle shows higher sensitivity with marginally lower specificity. Therefore, the CTA is not superior in predicting varus stem alignment in short-stem THA. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Estudos Retrospectivos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Radiografia , Desenho de Prótese
18.
Arch Orthop Trauma Surg ; 143(3): 1193-1202, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34687350

RESUMO

BACKGROUND: Pelvic and femoral osteotomies have been effective methods to treat developmental dysplasia of the hip (DDH), neurogenic dislocation of the hip (NDH), and Legg-Calvé-Perthes disease (LCPD). The aim of this study was to evaluate the mid-term results after hip reconstruction in children with DDH, NDH, and LCPD. METHODS: In a retrospective study, X-rays of 73 children (2-19 years) with DDH, NDH, and LCPD were measured before, 3 months, and at final follow-up (FU) after hip reconstructive surgery (open reduction, and femoral and/or pelvic osteotomy ± soft-tissue procedures between 2008 and 2018). Measurement of hip geometry included acetabular index (AI), center-edge angle (CE), and Reimers migration index (RMI). Mean follow-up time at final FU was 4.9 years. P value was set P < 0.05. RESULTS: After surgery (femoral osteotomy: 84 hips, Salter innominate osteotomy: 21 hips, Pemberton osteotomy: 30 hips, open reduction: 28 hips, Chiari osteotomy: 4 hips, and soft-tissue release: 24 hips), hip geometry parameters improved significantly. Nevertheless, at final FU, there was deterioration in hip geometry with femoral head lateralization (RMI) compared to the data at 3 months after surgery (RMI: preop/3 months/final FU: 40.6 ± 16.1%/6.1 ± 9.0/15.4 ± 16.0%; CE: 11.3° ± 20.0°/30.2° ± 9.5°/27.9 ± 15.4°; AI: 28.8° ± 9.6°/19.1° ± 7.6°/18.3 ± 7.6°). Sub-group analysis did not show differences concerning the progression of RMI in DDH, NDH, and LCPD at final FU. Regardless of basic disease, the lateralization was observed in all three groups (DDH, NDH, and LCPD) and statistically significant comparing X-rays 3 months postoperatively to maximum follow-up (DDH; NDH; LCPD: 2.7 ± 6.8%/7.6 ± 10.1%; 13.7 ± 15.3%/22.8 ± 19.8%; 1.7 ± 4.1%/14.9 ± 11.3%). Additional soft-tissue release techniques in patients with DDH or NDH did not show postoperative differences with statistical significance. Concerning surgical techniques, a connection between the lower RMI and the procedure of osteotomy of the ilium was found. In 25 patients, (34%) complications were observed: superficial skin lesions in 8, deep skin lesions in 3, contraction of adductors in 3, subluxation in 2, dislocations of the cast in 2, osteonecrosis of the femoral head in 2 cases, reluxation in 1, infection of the implanted plate in 1, compliance problem in 1, delayed bone healing in 1, and contraction of knee flexors in 1 case. DISCUSSION: The basic results of this study show a significant improvement of hip geometry at a follow-up of 4.9 years and prove findings of previously published literature. Moreover, the study was able to show a progression of RMI in all patient groups, which have undergone reconstructive surgery, despite basic hip geometry data (AI, CE angle) did not change. Those findings were independent from underlying pathology. Complications were counted in 34% of the patients and involved all known adverse events after hip reconstructive surgery. This makes clear why annual follow-up checks are needed not to miss the right indication for revision surgery. CLINICAL RELEVANCE: Evidence level: Level IV, case series. TRIAL REGISTRATION: This manuscript is part of a prospective randomized clinical trial, registered in the German Clinical Trials Register DRKS-ID: DRKS00016861.


Assuntos
Luxação Congênita de Quadril , Luxação do Quadril , Doença de Legg-Calve-Perthes , Cirurgia Plástica , Humanos , Criança , Doença de Legg-Calve-Perthes/cirurgia , Estudos de Coortes , Seguimentos , Estudos Retrospectivos , Estudos Prospectivos , Resultado do Tratamento , Luxação do Quadril/cirurgia , Acetábulo/cirurgia , Articulação do Quadril/cirurgia , Luxação Congênita de Quadril/cirurgia
19.
Arch Orthop Trauma Surg ; 143(3): 1619-1626, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35179634

RESUMO

PURPOSE: Minimally invasive approaches (MIS) in total hip arthroplasty (THA) show inconsistent findings regarding planning adherence in digital templating. The purpose of this study is to evaluate any difference in planning adherence between the direct anterior approach (DAA) and an anterolateral MIS approach (AL MIS) in cementless short stem THA. METHODS: A single surgeon series of 222 THAs in 208 patients with an uncemented short curved stem and a bi-hemispherical acetabular cup were screened for inclusion. A total of 118 THAs were implanted via the DAA and 72 THAs via the AL MIS were included. The planning adherence for the offset option, stem size and the acetabular cup were retrospectively evaluated. RESULTS: Planning adherence for cup size (perfect match: p = 0.763; ± 1 size: p = 0.124), offset option (0.125) and stem size (perfect match: p = 0.275; ± 1 size: p = 0.552) did not show any statistical significance. Preoperative diagnosis of avascular necrosis of the femoral head in AL MIS approach (OR 6.045; CI 1.153-31.696) or mild hip dysplasia in the general cohort poses (OR 11.789; CI 1.386-100.293) a significant risk for inadequate prediction of the offset option. CONCLUSION: digital templating for THA with an uncemented short curved stem and a bi-hemispherical acetabular cup show comparable results between a direct anterior approach and a minimally invasive anterolateral approach in supine position. Surgeons should be aware of a low planning adherence for this type of short stem in minimally invasive approaches. CONCLUSION: Digital templating for THA with an uncemented short curved stem and a bi-hemispherical acetabular cup show comparable results between a direct anterior approach and a minimally invasive anterolateral approach in supine position. Surgeons should be aware of a low planning adherence for this type of short stem in minimally invasive approaches.


Assuntos
Artroplastia de Quadril , Luxação Congênita de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Acetábulo
20.
Arch Orthop Trauma Surg ; 143(1): 519-527, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34997306

RESUMO

PURPOSE: Short stems are increasingly used in total hip arthroplasty (THA) because of advantages in bone and soft tissue preservation and reconstruction of hip geometry. Digital templating is essential in determining the correct offset option and stem size in THA. However, the preoperative template sizes might be intraoperatively overruled. PATIENTS AND METHODS: We evaluated the effect of intraoperative overruling of the preoperatively templated offset option of a short curved stem on hip offset, leg length, implant positioning, and femoral canal fill index. The overruling was performed in case of intraoperative instability, telescoping, or both. A series of 1052 consecutive THAs with a cementless short curved stem and press-fit cup was retrospectively screened. One hundred patients with unilateral THA and a contralateral native and morphologically healthy hip as a reference met the inclusion criteria. Measurements were carried out on preoperative and 3 months anterior-posterior postoperative radiographs. Patients were divided according to the overruling by offset option or stem size. RESULTS: Hip offset was increased in all groups, but only with significant increase if an offset option + 1 was used intraoperatively (p = 0.025). LLD was restored without significance in all groups (p = 0.323; p = 0.157). CONCLUSION: Intraoperative overruling of the preoperative digital template in cementless short stem total hip arthroplasty results in an increase of hip offset compared to a contralateral healthy hip. However, the increase is marginal and clearly under 5 mm compared to the contralateral healthy hip.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Radiografia , Osso e Ossos/cirurgia , Articulação do Quadril/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...