Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(12): 125106, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36586895

RESUMO

We introduce the setup of a versatile sample chamber for x-ray scattering experiments on liquids delivered by µ-jets. The simple implementation at x-ray light sources, adaptability to different nozzle types, and the availability of a microscope for observation of the jet flow allow for its broad application. In combination with an inbuilt recycling circle, a continuous flow operation is provided. Functionality of the system was demonstrated in a rheology study at PETRA III.

2.
Struct Dyn ; 7(5): 054901, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33094129

RESUMO

We applied shear to a silica nanoparticle dispersion in a microfluidic jet device and observed direction-dependent structure along and across the flow direction. The asymmetries of the diffraction patterns were evaluated by x-ray cross correlation analysis. For different Rayleigh nozzle sizes and shapes, we measured the decay of the shear-induced ordering after the cessation of the shear. At large tube sizes and small shear rates, the characteristic times of the decay become longer, but Péclet-weighted times do not scale linearly with Péclet numbers. By modeling particle distributions with the corresponding diffraction patterns and comparing measured shape asymmetry to simulations, we determined the variation of volume fraction over the azimuthal angle for the maximum ordered state in the jet.

3.
Sci Adv ; 6(12): eaaz2982, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32219168

RESUMO

Residual stresses are well-known companions of all glassy materials. They affect and, in many cases, even strongly modify important material properties like the mechanical response and the optical transparency. The mechanisms through which stresses affect such properties are, in many cases, still under study, and their full understanding can pave the way to a full exploitation of stress as a primary control parameter. It is, for example, known that stresses promote particle mobility at small length scales, e.g., in colloidal glasses, gels, and metallic glasses, but this connection still remains essentially qualitative. Exploiting a preparation protocol that leads to colloidal glasses with an exceptionally directional built-in stress field, we characterize the stress-induced dynamics and show that it can be visualized as a collection of "flickering," mobile regions with linear sizes of the order of ≈20 particle diameters (≈2 µm here) that move cooperatively, displaying an overall stationary but locally ballistic dynamics.

4.
Rev Sci Instrum ; 90(4): 045106, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31042974

RESUMO

We present a novel experimental setup for performing a precise pre-alignment of a hard X-ray split-and-delay unit based on low coherence light interferometry and high-precision penta-prisms. A split-and-delay unit is a sophisticated perfect crystal-optics device that splits an incoming X-ray pulse into two sub-pulses and generates a controlled time-delay between them. While the availability of a split-and-delay system will make ultrafast time-correlation and X-ray pump-probe experiments possible at free-electron lasers, its alignment process can be very tedious and time-consuming due to its complex construction. By implementing our experimental setup at beamline P10 of PETRA III, we were able to reduce the time of alignment to less than 3 h. We also propose an alternate method for finding the zero-time delay crossing without the use of X-rays or pulsed laser sources. The successful demonstration of this method brings prospect for operating the split-and-delay systems under alignment-time-critical environments such as X-ray free electron laser facilities.

5.
Rev Sci Instrum ; 90(3): 036103, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30927793

RESUMO

We present a sample environment for the investigation of nanoparticle self-assembly from a colloidal solution via controlled solvent evaporation using in situ small-angle X-ray scattering. Nanoparticles form ordered superlattices in the evaporative assembly along the X-ray transparent windows of a three-dimensional sample cell. The special design of the sample cell allows for monitoring the superlattice formation and transformation at different stages of the assembly process during the movement of the evaporation front in real time. The presented sample environment can be used to study the self-organization of a wide range of colloidal particles and other soft materials.

6.
Nat Commun ; 9(1): 1704, 2018 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-29703980

RESUMO

One of the important challenges in condensed matter science is to understand ultrafast, atomic-scale fluctuations that dictate dynamic processes in equilibrium and non-equilibrium materials. Here, we report an important step towards reaching that goal by using a state-of-the-art perfect crystal based split-and-delay system, capable of splitting individual X-ray pulses and introducing femtosecond to nanosecond time delays. We show the results of an ultrafast hard X-ray photon correlation spectroscopy experiment at LCLS where split X-ray pulses were used to measure the dynamics of gold nanoparticles suspended in hexane. We show how reliable speckle contrast values can be extracted even from very low intensity free electron laser (FEL) speckle patterns by applying maximum likelihood fitting, thus demonstrating the potential of a split-and-delay approach for dynamics measurements at FEL sources. This will enable the characterization of equilibrium and, importantly also reversible non-equilibrium processes in atomically disordered materials.

7.
Rev Sci Instrum ; 89(3): 036103, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29604789

RESUMO

A transmission polarizer for producing elliptically polarized soft X-ray radiation from linearly polarized light is presented. The setup is intended for use at synchrotron and free-electron laser beamlines that do not directly offer circularly polarized light for, e.g., X-ray magnetic circular dichroism (XMCD) measurements or holographic imaging. Here, we investigate the degree of ellipticity upon transmission of linearly polarized radiation through a cobalt thin film. The experiment was performed at a photon energy resonant to the Co L3-edge, i.e., 778 eV, and the polarization of the transmitted radiation was determined using a polarization analyzer that measures the directional dependence of photo electrons emitted from a gas target. Elliptically polarized radiation can be created at any absorption edge showing the XMCD effect by using the respective magnetic element.

8.
Rev Sci Instrum ; 87(6): 063905, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27370468

RESUMO

In this paper we describe a setup for x-ray scattering experiments on complex fluids using a liquid jet. The setup supports Small and Wide Angle X-ray Scattering (SAXS/WAXS) geometries. The jet is formed by a gas-dynamic virtual nozzle (GDVN) allowing for diameters ranging between 1 µm and 20 µm at a jet length of several hundred µm. To control jet properties such as jet length, diameter, or flow rate, the instrument is equipped with several diagnostic tools. Three microscopes are installed to quantify jet dimensions and stability in situ. The setup has been used at several beamlines performing both SAXS and WAXS experiments. As a typical example we show an experiment on a colloidal dispersion in a liquid jet at the X-ray Correlation Spectroscopy instrument at the Linac Coherent Light Source free-electron laser.

9.
J Chem Phys ; 144(8): 084903, 2016 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-26931722

RESUMO

We report on high pressure small angle x-ray scattering on suspensions of colloidal crystallites in water. The crystallites made out of charge-stabilized poly-acrylate particles exhibit a complex pressure dependence which is based on the specific pressure properties of the suspending medium water. The dominant effect is a compression of the crystallites caused by the compression of the water. In addition, we find indications that also the electrostatic properties of the system, i.e. the particle charge and the dissociation of ions, might play a role for the pressure dependence of the samples. The data further suggest that crystallites in a metastable state induced by shear-induced melting can relax to a similar structural state upon the application of pressure and dilution with water. X-ray cross correlation analysis of the two-dimensional scattering patterns indicates a pressure-dependent increase of the orientational order of the crystallites correlated with growth of these in the suspension. This study underlines the potential of pressure as a very relevant parameter to understand colloidal crystallite systems in aqueous suspension.

10.
Artigo em Inglês | MEDLINE | ID: mdl-25974493

RESUMO

We report x-ray photon correlation spectroscopy experiments on the dynamics of the glass-former polypropylene glycol covering a temperature range from room temperature to the glass transition at T(g)=205 K using silica tracer particles. Three temperature regimes are identified: At high temperatures, Brownian motion of the tracer particles is observed. Near T(g), the dynamics is hyperdiffusive and ballistic. Around 1.12T(g), we observe an intermediate regime. Here the stretching exponent of the Kohlrausch-Williams-Watts function becomes q dependent. By analyzing higher-order correlations in the scattering data, we find that dynamical heterogeneities dramatically increase in this intermediate-temperature regime. This leads to two effects: increasing heterogeneous dynamics and correlated motion at temperatures close to and below 1.12T(g).

11.
Artigo em Inglês | MEDLINE | ID: mdl-25122305

RESUMO

Recently the analysis of scattering patterns by angular cross-correlation analysis (CCA) was introduced to reveal the orientational order in disordered samples with special focus to future applications on x-ray free-electron laser facilities. We apply this CCA approach to ultra-small-angle light-scattering data obtained from two-dimensional monolayers of microspheres. The films were studied in addition by optical microscopy. This combined approach allows to calculate the cross-correlations of the scattering patterns, characterized by the orientational correlation function Ψ(l)(q), as well as to obtain the real-space structure of the monolayers. We show that CCA is sensitive to the orientational order of monolayers formed by the microspheres which are not directly visible from the scattering patterns. By mixing microspheres of different radii the sizes of ordered monolayer domains is reduced. For these samples it is shown that Ψ(l)(q) quantitatively describes the degree of hexagonal order of the two-dimensional films. The experimental CCA results are compared with calculations based on the microscopy images. Both techniques show qualitatively similar features. Differences can be attributed to the wave-front distortion of the laser beam in the experiment. This effect is discussed by investigating the effect of different wave fronts on the cross-correlation analysis results. The so-determined characteristics of the cross-correlation analysis will be also relevant for future x-ray-based studies.


Assuntos
Luz , Microesferas , Espalhamento de Radiação
12.
J Synchrotron Radiat ; 21(Pt 4): 722-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24971966

RESUMO

A method to characterize the spatial coherence of soft X-ray radiation from a single diffraction pattern is presented. The technique is based on scattering from non-redundant arrays (NRAs) of slits and records the degree of spatial coherence at several relative separations from 1 to 15 µm, simultaneously. Using NRAs the spatial coherence of the X-ray beam at the XUV X-ray beamline P04 of the PETRA III synchrotron storage ring was measured as a function of different beam parameters. To verify the results obtained with the NRAs, additional Young's double-pinhole experiments were conducted and showed good agreement.

13.
Opt Express ; 21(21): 24647-64, 2013 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-24150309

RESUMO

The single shot based coherence properties of hard x-ray pulses from the Linac Coherent Light Source (LCLS) were measured by analyzing coherent diffraction patterns from nano-particles and gold nanopowder. The intensity histogram of the small angle x-ray scattering ring from nano-particles reveals the fully transversely coherent nature of the LCLS beam with a number of transverse mode 〈Ms〉 = 1.1. On the other hand, the speckle contrasts measured at a large wavevector yields information about the longitudinal coherence of the LCLS radiation after a silicon (111) monochromator. The quantitative agreement between our data and the simulation confirms a mean coherence time of 2.2 fs and a x-ray pulse duration of 29 fs. Finally the observed reduction of the speckle contrast generated by x-rays with pulse duration longer than 30 fs indicates ultrafast dynamics taking place at an atomic length scale prior to the permanent sample damage.

14.
Rev Sci Instrum ; 84(5): 051301, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23742525

RESUMO

FERMI@Elettra, the first vacuum ultraviolet and soft X-ray free-electron laser (FEL) using by default a "seeded" scheme, became operational in 2011 and has been opened to users since December 2012. The parameters of the seeded FERMI FEL pulses and, in particular, the superior control of emitted radiation in terms of spectral purity and stability meet the stringent requirements for single-shot and resonant coherent diffraction imaging (CDI) experiments. The advantages of the intense seeded FERMI pulses with variable polarization have been demonstrated with the first experiments performed using the multipurpose experimental station operated at the diffraction and projection imaging (DiProI) beamline. The results reported here were obtained with fixed non-periodic targets during the commissioning period in 2012 using 20-32 nm wavelength range. They demonstrate that the performance of the FERMI FEL source and the experimental station meets the requirements of CDI, holography, and resonant magnetic scattering in both multi- and single-shot modes. Moreover, we present the first magnetic scattering experiments employing the fully circularly polarized FERMI pulses. The ongoing developments aim at pushing the lateral resolution by using shorter wavelengths provided by double-stage cascaded FERMI FEL-2 and probing ultrafast dynamic processes using different pump-probe schemes, including jitter-free seed laser pump or FEL-pump∕FEL-probe with two color FEL pulses generated by the same electron bunch.

15.
Rev Sci Instrum ; 84(1): 013906, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23387667

RESUMO

An endstation for pump-probe small-angle X-ray scattering (SAXS) experiments at the free-electron laser in Hamburg (FLASH) is presented. The endstation houses a solid-state absorber, optical incoupling for pump-probe experiments, time zero measurement, sample chamber, and detection unit. It can be used at all FLASH beamlines in the whole photon energy range offered by FLASH. The capabilities of the setup are demonstrated by showing the results of resonant magnetic SAXS measurements on cobalt-platinum multilayer samples grown on freestanding Si(3)N(4) membranes and pump-laser-induced grid structures in multilayer samples.

16.
Phys Rev Lett ; 110(23): 234801, 2013 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-25167501

RESUMO

We present results of single-shot resonant magnetic scattering experiments of Co/Pt multilayer systems using 100 fs long ultraintense pulses from an extreme ultraviolet (XUV) free-electron laser. An x-ray-induced breakdown of the resonant magnetic scattering channel during the pulse duration is observed at fluences of 5 J/cm(2). Simultaneously, the speckle contrast of the high-fluence scattering pattern is significantly reduced. We performed simulations of the nonequilibrium evolution of the Co/Pt multilayer system during the XUV pulse duration. We find that the electronic state of the sample is strongly perturbed during the first few femtoseconds of exposure leading to an ultrafast quenching of the resonant magnetic scattering mechanism.

17.
Phys Rev Lett ; 109(18): 185502, 2012 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-23215295

RESUMO

The availability of ultrafast pulses of coherent hard x rays from the Linac Coherent Light Source opens new opportunities for studies of atomic-scale dynamics in amorphous materials. Here, we show that single ultrafast coherent x-ray pulses can be used to observe the speckle contrast in the high-angle diffraction from liquid Ga and glassy Ni(2)Pd(2)P and B(2)O(3). We determine the thresholds above which the x-ray pulses disturb the atomic arrangements. Furthermore, high contrast speckle is observed in scattering patterns from the glasses integrated over many pulses, demonstrating that the source and optics are sufficiently stable for x-ray photon correlation spectroscopy studies of dynamics over a wide range of time scales.


Assuntos
Vidro/química , Modelos Teóricos , Difração de Raios X/métodos , Compostos de Boro/química , Gálio/química , Níquel/química , Paládio/química , Fósforo/química , Fótons
18.
Opt Express ; 20(17): 18967-76, 2012 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-23038536

RESUMO

An x-ray transfocator design for the combined use of 1D and 2D compound refractive lenses is described. The device includes stacks of beryllium parabolic lenses with different radii of curvature and provides microfocused x-ray beams in the 4-20 keV photon energy range. The transfocator has been implemented at the P10 Coherence Beamline of the PETRA III synchrotron at DESY, Hamburg. Results of transfocator performance and applications for coherent x-ray scattering experiments are presented.


Assuntos
Lentes , Refratometria/instrumentação , Síncrotrons/instrumentação , Transdutores , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização
19.
Nat Commun ; 3: 1100, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23033076

RESUMO

During ultrafast demagnetization of a magnetically ordered solid, angular momentum has to be transferred between the spins, electrons, and phonons in the system on femto- and picosecond timescales. Although the intrinsic spin-transfer mechanisms are intensely debated, additional extrinsic mechanisms arising due to nanoscale heterogeneity have only recently entered the discussion. Here we use femtosecond X-ray pulses from a free-electron laser to study thin film samples with magnetic domain patterns. We observe an infrared-pump-induced change of the spin structure within the domain walls on the sub-picosecond timescale. This domain-topography-dependent contribution connects the intrinsic demagnetization process in each domain with spin-transport processes across the domain walls, demonstrating the importance of spin-dependent electron transport between differently magnetized regions as an ultrafast demagnetization channel. This pathway exists independent from structural inhomogeneities such as chemical interfaces, and gives rise to an ultrafast spatially varying response to optical pump pulses.

20.
Phys Rev Lett ; 108(2): 024801, 2012 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-22324689

RESUMO

We measured the transverse and longitudinal coherence properties of the Linac Coherent Light Source (LCLS) at SLAC in the hard x-ray regime at 9 keV photon energy on a single shot basis. Speckle patterns recorded in the forward direction from colloidal nanoparticles yielded the transverse coherence properties of the focused LCLS beam. Speckle patterns from a gold nanopowder recorded with atomic resolution allowed us to measure the shot-to-shot variations of the spectral properties of the x-ray beam. The focused beam is in the transverse direction fully coherent with a mode number close to 1. The average number of longitudinal modes behind the Si(111) monochromator is about 14.5 and the average coherence time τ(c)=(2.0±1.0) fc. The data suggest a mean x-ray pulse duration of (29±14) fs behind the monochromator for (100±14) fc electron pulses.


Assuntos
Ouro/química , Luz , Nanopartículas Metálicas/química , Modelos Teóricos , Nanoestruturas/química , Fótons , Elétrons , Aceleradores de Partículas , Espalhamento de Radiação , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...