Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38838164

RESUMO

X-ray gas monitors (XGMs) are operated at the European XFEL for non-invasive single-shot pulse energy measurements and average beam-position monitoring. The underlying measurement principle is the photo-ionization of rare gas atoms at low gas pressures and the detection of the photo-ions and photo-electrons created. These are essential for tuning and sustaining self-amplified spontaneous emission (SASE) operation, machine radiation safety, and sorting single-shot experimental data according to pulse energy. In this paper, the first results from XGM operation at photon energies up to 30 keV are presented, which are far beyond the original specification of this device. Here, the Huge Aperture MultiPlier (HAMP) is used for single-shot pulse energy measurements since the standard X-ray gas monitor detectors (XGMDs) do not provide a sufficient signal-to-noise ratio, even at the highest operating gas pressures. A single-shot correlation coefficient of 0.98 is measured between consecutive XGMs operated with HAMP, which is as good as measuring with the standard XGMD detectors. An intra-train non-linearity of the HAMP signal is discovered, and operation parameters to mitigate this effect are studied. The upper repetition rate limit of HAMP operation at 2.25 MHz is also determined. Finally, the possibilities and limits for future XGM operation at photon energies up to 50 keV are discussed.

2.
Complement Med Res ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38744266

RESUMO

BACKGROUND: Neck reflex points or Adler-Langer Points are commonly used in neural therapy to detect so-called interference fields. Chronic irritations or inflammations in the sinuses, teeth, tonsils or ears are supposed to induce tension and tenderness of the soft tissues and short muscles in the upper cervical spine. The individual treatment strategy is based on the results of diagnostic Adler-Langer Points palpation. This study investigated the inter- and intra-rater reliability and explored treatment effects. METHODS: We performed a randomized-controlled trial with 104 inpatients (80.8% female, 51.812.74 yrs) of a German department for internal and integrative medicine. Patients were randomized to individual neural therapy according to the pathological findings (n=48) or no treatment (n=56). In each patient, three experienced raters (20-45y experience in neural therapy) and two novice raters (medical students) rated Adler-Langer Points rigidity on a standardized rating scale ("strong", "weak", "none"). The patients independently evaluated the tenderness on palpation of the eight points using the same scale. Pressure pain thresholds were assessed at the eight Adler-Langer Points. All patients were retested after 30 minutes. The five raters were blinded to treatment allocation and assessments of the other raters. Video recordings were obtained to assess the consistency of the areas tested by the different raters. RESULTS: Agreement between patients and raters (Cohen's Kappa=.161-.400) and inter-rater reliability were low (Fleiss-Kappa=.132-.150). Moreover, the individual agreement (pre-post comparisons in untreated patients) was similarly low even in experienced raters (Cohen's Kappa=.099-.173). Video documentation suggests that raters do not place their fingers in the correct segments (percentage of correct position 42.0-60.6%). Pressure pain thresholds at five of the eight Adler-Langer Points showed significant changes after treatment compared to none in the control group. CONCLUSION: Under this artificial experimental setting, this method of Adler-Langer Point palpation has not proven to be a reliable diagnostic tool. But it could be shown, that as claimed by the method, the tenderness in five of eight Adler-Langer Points decreased after neural therapy.

3.
Sci Rep ; 13(1): 16344, 2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37770502

RESUMO

Modern X-ray free-electron lasers (XFELs) produce intense femtosecond X-ray pulses able to cause significant damage to irradiated targets. Energetic photoelectrons created upon X-ray absorption, and Auger electrons emitted after relaxation of core-hole states trigger secondary electron cascades, which contribute to the increasing transient free electron density on femtosecond timescales. Further evolution may involve energy and particle diffusion, creation of point defects, and lattice heating. This long-timescale (up to a microsecond) X-ray-induced dynamics is discussed on the example of silicon in two-dimensional geometry. For modeling, we apply an extended Two-Temperature model with electron density dynamics, nTTM, which describes relaxation of an irradiated sample between two successive X-ray pulses, emitted from XFEL at MHz pulse repetition rate. It takes into account ambipolar carrier diffusion, electronic and atomic heat conduction, as well as electron-ion coupling. To solve the nTTM system of equations in two dimensions, we developed a dedicated finite-difference integration algorithm based on Alternating Direction Implicit method with an additional predictor-corrector scheme. We show first results obtained with the model and discuss its possible applications for XFEL optics, detectors, and for diagnostics tools. In particular, the model can estimate the timescale of material relaxation relevant for beam diagnostic applications during MHz operation of contemporary and future XFELs.

4.
Rev Sci Instrum ; 93(11): 115111, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461550

RESUMO

The development and characterization of an angle-resolved photoelectron spectrometer, based on the electron time-of-flight concept, for hard x-ray photon diagnostics at the European Free-Electron Laser, are described. The instrument is meant to provide users and operators with pulse-resolved, non-invasive spectral distribution diagnostics, which in the hard x-ray regime is a challenge due to the poor cross-section and high kinetic energy of photoelectrons for the available target gases. We report on the performances of this instrument as obtained using hard x-rays at the PETRA III synchrotron at DESY in multibunch mode. Results are compared with electron trajectory simulations. We demonstrate a resolving power of 10 eV at incident photon energies up to at least 20 keV.

5.
J Synchrotron Radiat ; 29(Pt 5): 1273-1283, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36073887

RESUMO

Pump-probe experiments at X-ray free-electron laser (XFEL) facilities are a powerful tool for studying dynamics at ultrafast and longer timescales. Observing the dynamics in diverse scientific cases requires optical laser systems with a wide range of wavelength, flexible pulse sequences and different pulse durations, especially in the pump source. Here, the pump-probe instrumentation available for measurements at the Single Particles, Clusters, and Biomolecules and Serial Femtosecond Crystallography (SPB/SFX) instrument of the European XFEL is reported. The temporal and spatial stability of this instrumentation is also presented.


Assuntos
Lasers , Cristalografia por Raios X , Radiografia , Raios X
6.
Opt Express ; 29(23): 37429-37442, 2021 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-34808814

RESUMO

This contribution presents the initial characterization of the pump-probe performance at the Small Quantum Systems (SQS) instrument of the European X-ray Free Electron Laser. It is demonstrated that time-resolved experiments can be performed by measuring the X-ray/optical cross-correlation exploiting the laser-assisted Auger decay in neon. Applying time-of-arrival corrections based on simultaneous spectral encoding measurements allow us to significantly improve the temporal resolution of this experiment. These results pave the way for ultrafast pump-probe investigations of gaseous media at the SQS instrument combining intense and tunable soft X-rays with versatile optical laser capabilities.

7.
Rev Sci Instrum ; 91(10): 103101, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33138553

RESUMO

The European X-ray Free-Electron Laser Facility in Germany delivers x-ray pulses with femtosecond pulse duration at a repetition rate of up to 4.5 MHz. The free-electron laser radiation is created by the self-amplified spontaneous emission (SASE) process, whose stochastic nature gives rise to shot-to-shot fluctuations in most beam properties, including spectrum, pulse energy, spatial profile, wavefront, and temporal profile. Each spectrum consisting of many spikes varies in width and amplitude that appear differently within the envelope of the SASE spectrum. In order to measure and study the SASE spectrum, the HIgh REsolution hard X-ray single-shot (HIREX) spectrometer was installed in the photon tunnel of the SASE1 undulator beamline. It is based on diamond gratings, bent crystals as a dispersive element, and a MHz-repetition-rate strip detector. It covers a photon energy range of 3 keV-25 keV and a bandwidth of 0.5% of the SASE beam. The SASE spikes are resolved with 0.15 eV separation using the Si 440 reflection, providing a resolving power of 60 000 at a photon energy of 9.3 keV. The measured SASE bandwidth is 25 eV. In this paper, we discuss the design specifications, installation, and commissioning of the HIREX spectrometer. The spectral results using Si (110), Si (111), and C (110) crystals are presented.

9.
J Synchrotron Radiat ; 26(Pt 5): 1400-1405, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31490127

RESUMO

Detectors based on microchannel plates (MCPs) are used to detect radiation from free-electron lasers. Three MCP detectors have been developed by JINR for the European XFEL (SASE1, SASE2 and SASE3 lines). These detectors are designed to operate in a wide dynamic range from the level of spontaneous emission to the SASE saturation level (between a few nJ up to 25 mJ), in a wide wavelength range from 0.05 nm to 0.4 nm for SASE1 and SASE2, and from 0.4 nm to 4.43 nm for SASE3. The detectors measure photon pulse energies with an anode and a photodiode. The photon beam image is observed with an MCP imager with a phosphor screen. At present, the SASE1 and SASE3 MCP detectors are commissioned with XFEL beams. Calibration and first measurements of photon radiation in multibunch mode are performed with the SASE1 and SASE3 MCPs. The MCP detector for SASE2 and its electronics are installed in the XFEL tunnel, technically commissioned, and are now ready for acceptance tests with the X-ray beam.


Assuntos
Lasers , Dosimetria por Luminescência Estimulada Opticamente/instrumentação , Calibragem , Desenho de Equipamento , Aceleradores de Partículas , Fótons , Raios X
10.
J Synchrotron Radiat ; 26(Pt 5): 1422-1431, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31490130

RESUMO

The European X-ray Free-Electron Laser (European XFEL) (Altarelli et al., 2006; Tschentscher et al., 2017), the world's largest and brightest X-ray free-electron laser (Saldin et al., 1999; Pellegrini et al., 2016), went into operation in 2017. This article describes the as-built realization of photon diagnostics for this facility, the diagnostics commissioning and their application for commissioning of the facility, and results from the first year of operation, focusing on the SASE1 beamline, which was the first to be commissioned. The commissioning consisted of pre-beam checkout, first light from the bending magnets, X-rays from single undulator segments, SASE tuning with many undulator segments, first lasing, optics alignment for FEL beam transport through the tunnel up to the experiment hutches, and finally beam delivery to first users. The beam properties assessed by photon diagnostics throughout these phases included per-pulse intensity, beam position, shape, lateral dimensions and spectral properties. During this time period, the machine provided users with up to 14 keV photon energy, 1.5 mJ pulse energy, 300 FEL pulses per train and 4.5 MHz intra-bunch train repetition rate at a 10 Hz train repetition rate. Finally, an outlook is given into the diagnostic prospects for the future.


Assuntos
Lasers , Aceleradores de Partículas , Monitoramento de Radiação/métodos , Calibragem , Desenho de Equipamento , Europa (Continente) , Fótons , Raios X
11.
J Synchrotron Radiat ; 26(Pt 5): 1489-1495, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31490136

RESUMO

X-ray photon beam diagnostic imagers are located at 24 positions in the European XFEL beam transport system to characterize the X-ray beam properties, and to give feedback for tuning and optimization of the electron acceleration and orbit, the undulators, and the X-ray optics. One year of commissioning allowed experience to be gained with these imagers, which will be reported here. The sensitive Spontaneous Radiation imager is useful for various investigations in spontaneous radiation mode: for undulator adjustments and for low-signal imaging applications. The high-resolution Free-Electron Laser imager, 10 µm spatial resolution, is extensively used for the monitoring of beam position, spot size and shape, gain curve measurements, and also for beam-intensity monitoring. The wide field-of-view pop-in monitors (up to 200 mm) are regularly used for alignment and tuning of the various X-ray optical components like mirrors, slits and monochromators, and also for on-line beam control of a stable beam position at the instruments. The Exit Slit imager after the soft X-ray monochromator provides spectral information of the beam together with multi-channel plate based single-pulse gating. For particular use cases, these special features of the imagers are described. Some radiation-induced degradation of scintillators took place in this initial commissioning phase, providing useful information for better understanding of damage thresholds. Visible-light radiation in the beam pipe generated by upstream bending magnets caused spurious reflections in the optical system of some of the imagers which can be suppressed by aluminium-coated scintillating screens.


Assuntos
Lasers , Monitoramento de Radiação/métodos , Artefatos , Desenho de Equipamento , Europa (Continente) , Óptica e Fotônica , Fótons , Raios X
12.
J Synchrotron Radiat ; 26(Pt 4): 1010-1016, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31274422

RESUMO

Commissioning and first operation of an angle-resolved photoelectron spectrometer for non-invasive shot-to-shot diagnostics at the European XFEL soft X-ray beamline are described. The objective with the instrument is to provide the users and operators with reliable pulse-resolved information regarding photon energy and polarization that opens up a variety of applications for novel experiments but also hardware optimization.


Assuntos
Espectroscopia Fotoeletrônica/instrumentação , Raios X , Europa (Continente) , Fótons
13.
J Synchrotron Radiat ; 26(Pt 4): 1037-1044, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31274425

RESUMO

Hard X-ray free-electron lasers (XFELs) generate intense coherent X-ray beams by passing electrons through undulators, i.e. very long periodic magnet structures, which extend over hundreds of meters. The SASE1 and SASE2 undulator systems of the European XFEL consist of 35 segments with variable-gap planar undulators which are initially tuned to precise on-axis magnetic field strengths in a magnetic measurement laboratory to keep an important quality parameter - the K-value variation from segment to segment - below a certain limit (3 × 10-4 for 12 keV photon energy). After tunnel installation only photon-based methods can determine the K-values of undulator segments with a similar accuracy. The synchrotron radiation from a single or a few segments can be spectrally filtered by a dedicated crystal monochromator (K-monochromator) and recorded with a photodiode or with an imager that provides 2D information, tuned for high sensitivity to detect low photon densities from distant single undulator segments. This instrumentation is applied for electron orbit analysis and optimization, and adjustment of individual undulators in terms of their central magnetic axis with respect to the electron beam. Single undulator segments were analysed by scanning the monochromator crystal angle and detecting the steepest slope of a photodiode signal. Alternatively, in the imaging method, an imager recorded the radiation cone of electrons passing through the undulator segment. From the spatial distribution of the radiation, the K-parameter was determined with a sufficiently high relative accuracy.

14.
J Synchrotron Radiat ; 26(Pt 4): 1045-1051, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31274426

RESUMO

X-ray gas monitors (XGMs) are operated at the European XFEL for non-invasive single-shot pulse energy measurements and average beam position monitoring. They are used for tuning and maintaining the self-amplified spontaneous emission (SASE) operation and for sorting single-shot experimental data according to the pulse-resolved energy monitor data. The XGMs were developed at DESY based on the specific requirements for the European XFEL. In total, six XGM units are continuously in operation. Here, the main principle and experimental setup of an XGM are summarized, and the locations of the six XGMs at the facility are shown. Pulse energy measurements at 0.134 nm wavelength are presented, exceeding 1 mJ obtained with an absolute measurement uncertainty of 7-10%; correlations between different XGMs are shown, from which a SASE1 beamline transmission of 97% is deduced. Additionally, simultaneous position measurements close to the undulator and at the end of the tunnel are shown, along with the correlation of beam position data simultaneously acquired by an XGM and an imager.

15.
J Synchrotron Radiat ; 26(Pt 3): 708-713, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-31074434

RESUMO

The European X-ray Free Electron Laser (EuXFEL) offers intense, coherent femtosecond pulses, resulting in characteristic peak brilliance values a billion times higher than that of conventional synchrotron facilities. Such pulses result in extreme peak radiation levels of the order of terawatts cm-2 for any optical component in the beam and can exceed the ablation threshold of many materials. Diamond is considered the optimal material for such applications due to its high thermal conductivity (2052 W mK-1 at 300 K) and low absorption for hard X-rays. Grating structures were fabricated on free-standing CVD diamond of 10 µm thickness with 500 µm silicon substrate support. The grating structures were produced by electron-beam lithography at the Laboratory for Micro- and Nanotechnology, Paul Scherrer Institut, Switzerland. The grating lines were etched to a depth of 1.2 µm, resulting in an aspect ratio of 16. The characterization measurements with X-rays were performed on transmissive diamond gratings of 150 nm pitch at the P10 beamline of PETRA III, DESY. In this paper, the gratings are briefly described, and a measured diffraction efficiency of 0.75% at 6 keV in the first-order diffraction is shown; the variation of the diffraction efficiency across the grating surface is presented.

16.
Opt Lett ; 44(7): 1650-1653, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30933113

RESUMO

Intense, ultrashort, and high-repetition-rate X-ray pulses, combined with a femtosecond optical laser, allow pump-probe experiments with fast data acquisition and femtosecond time resolution. However, the relative timing of the X-ray pulses and the optical laser pulses can be controlled only to a level of the intrinsic error of the instrument which, without characterization, limits the time resolution of experiments. This limitation inevitably calls for a precise determination of the relative arrival time, which can be used after measurement for sorting and tagging the experimental data to a much finer resolution than it can be controlled to. The observed root-mean-square timing jitter between the X-ray and the optical laser at the SPB/SFX instrument at European XFEL was 308 fs. This first measurement of timing jitter at the European XFEL provides an important step in realizing ultrafast experiments at this novel X-ray source. A method for determining the change in the complex refractive index of samples is also presented.

17.
J Synchrotron Radiat ; 25(Pt 1): 177-188, 2018 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29271767

RESUMO

Solid-state ionization chambers are presented based on thin diamond crystals that allow pulse-resolved intensity measurements at a hard X-ray free-electron laser (FEL), up to the 4.5 MHz repetition rate that will become available at the European XFEL. Due to the small X-ray absorption of diamond the thin detectors are semi-transparent which eases their use as non-invasive monitoring devices in the beam. FELs are characterized by strong pulse-to-pulse intensity fluctuations due to the self-amplified spontaneous emission (SASE) process and in many experiments it is mandatory to monitor the intensity of each individual pulse. Two diamond detectors with different electrode materials, beryllium and graphite, were tested as intensity monitors at the XCS endstation of the Linac Coherent Light Source (LCLS) using the pink SASE beam at 9 keV. The performance is compared with LCLS standard monitors that detect X-rays backscattered from thin SiN foils placed in the beam. The graphite detector can also be used as a beam position monitor although with rather coarse resolution.

18.
Nat Commun ; 3: 947, 2012 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-22781760

RESUMO

The high photon flux and femtosecond pulse duration of hard X-ray free-electron lasers have spurred a large variety of novel and fascinating experiments in physical, chemical and biological sciences. Many of these experiments depend fundamentally on a clean, well-defined wavefront. Here we explore the wavefront properties of hard X-ray free-electron laser radiation by means of a grating interferometer, from which we obtain shot-to-shot wavefront information with an excellent angular sensitivity on the order of ten nanoradian. The wavefront distortions introduced by optical elements are observed in-situ and under operational conditions. The source-point position and fluctuations are measured with unprecedented accuracy in longitudinal and lateral direction, both during nominal operation and as the X-ray free-electron laser is driven into saturation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...