Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 92(5): 053537, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243288

RESUMO

A new pseudolocal tomography algorithm is developed for soft X-ray(SXR) imaging measurements of the turbulent electron temperature fluctuations (δ Te) in tokamaks and stellarators. The algorithm overcomes the constraints of limited viewing ports on the vessel wall (viewing angle) and limited number of lines of sight (LOS). This is accomplished by increasing the number of LOS locally in a region of interest. Numerical modeling demonstrates that the wavenumber spectrum of the turbulence can be reliably reconstructed, with an acceptable number of viewing angles and LOS and suitable low SNR detectors. We conclude that a SXR imaging diagnostic for measurements of turbulent δ Te using a pseudolocal reconstruction algorithm is feasible.

2.
Phys Rev Lett ; 118(25): 255002, 2017 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-28696735

RESUMO

Novel spatial, temporal, and energetically resolved measurements of bremsstrahlung hard-x-ray (HXR) emission from runaway electron (RE) populations in tokamaks reveal nonmonotonic RE distribution functions whose properties depend on the interplay of electric field acceleration with collisional and synchrotron damping. Measurements are consistent with theoretical predictions of momentum-space attractors that accumulate runaway electrons. RE distribution functions are measured to shift to a higher energy when the synchrotron force is reduced by decreasing the toroidal magnetic field strength. Increasing the collisional damping by increasing the electron density (at a fixed magnetic and electric field) reduces the energy of the nonmonotonic feature and reduces the HXR growth rate at all energies. Higher-energy HXR growth rates extrapolate to zero at the expected threshold electric field for RE sustainment, while low-energy REs are anomalously lost. The compilation of HXR emission from different sight lines into the plasma yields energy and pitch-angle-resolved RE distributions and demonstrates increasing pitch-angle and radial gradients with energy.

3.
Rev Sci Instrum ; 86(10): 103506, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26520954

RESUMO

The design, calibration, and installation of disruption halo current sensors for the Experimental Advanced Superconducting Tokamak are described in this article. All the sensors are Rogowski coils that surround conducting structures, and all the signals are analog integrated. Coils with two different cross-section sizes have been fabricated, and their mutual inductances are calibrated. Sensors have been installed to measure halo currents in several different parts of both the upper divertor (tungsten) and lower divertor (graphite) at several toroidal locations. Initial measurements from disruptions show that the halo current diagnostics are working well.

4.
Phys Rev Lett ; 111(12): 125003, 2013 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-24093268

RESUMO

Application of lower hybrid (LH) current drive in tokamak plasmas can induce both co- and countercurrent directed changes in toroidal rotation, depending on the core q profile. For discharges with q(0) <1, rotation increments in the countercurrent direction are observed. If the LH-driven current is sufficient to suppress sawteeth and increase q(0) above unity, the core toroidal rotation change is in the cocurrent direction. This change in sign of the rotation increment is consistent with a change in sign of the residual stress (the divergence of which constitutes an intrinsic torque that drives the flow) through its dependence on magnetic shear.

5.
Rev Sci Instrum ; 83(7): 073501, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22852689

RESUMO

A scintillator-based energetic ion loss detector has been successfully commissioned on the Alcator C-Mod tokamak. This probe is located just below the outer midplane, where it captures ions of energies up to 2 MeV resulting from ion cyclotron resonance heating. After passing through a collimating aperture, ions impact different regions of the scintillator according to their gyroradius (energy) and pitch angle. The probe geometry and installation location are determined based on modeling of expected lost ions. The resulting probe is compact and resembles a standard plasma facing tile. Four separate fiber optic cables view different regions of the scintillator to provide phase space resolution. Evolving loss levels are measured during ion cyclotron resonance heating, including variation dependent upon individual antennae.

6.
Rev Sci Instrum ; 81(10): 10D709, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033902

RESUMO

A novel integrated charge exchange recombination spectroscopy (CXRS)/beam emission spectroscopy (BES) system is proposed for C-Mod, in which both measurements are taken from a shared viewing geometry. The supplementary BES system serves to quantify local beam densities and supplants the common calculation of beam attenuation. The new system employs two optical viewing arrays, 20 poloidal and 22 toroidal channels. A dichroic filter splits the light between two spectrometers operating at different wavelengths for impurity ion and beam neutrals emission. In this arrangement, the impurity density is inferred from the electron density, measured BES and CXRS spectral radiances, and atomic emission rates.

7.
Rev Sci Instrum ; 79(10): 10F529, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044672

RESUMO

This diagnostic measures temperature, density, and rotation for the fully stripped boron ion between the pedestal top and the plasma core with resolution consistent with the profile gradients. The diagnostic neutral beam used for the measurements generates a 50 keV, 6 A hydrogen beam. The optical systems provide views in both poloidal and toroidal directions. The imaging spectrometer is optimized to simultaneously accept 45 views as input with minimum cross-talk. In situ calibration techniques are applied for spatial location, spectral intensity, and wavelength. In the analysis, measured spectra are fitted to a model constructed from a detailed description of the emission physics. Methods for removal of interfering spectra are included. Applications include impurity and thermal transport.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...