Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Nat Commun ; 15(1): 2126, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38459105

RESUMO

Ocean warming and acidification, decreases in dissolved oxygen concentrations, and changes in primary production are causing an unprecedented global redistribution of marine life. The identification of underlying ecological processes underpinning marine species turnover, particularly the prevalence of increases of warm-water species or declines of cold-water species, has been recently debated in the context of ocean warming. Here, we track changes in the mean thermal affinity of marine communities across European seas by calculating the Community Temperature Index for 65 biodiversity time series collected over four decades and containing 1,817 species from different communities (zooplankton, coastal benthos, pelagic and demersal invertebrates and fish). We show that most communities and sites have clearly responded to ongoing ocean warming via abundance increases of warm-water species (tropicalization, 54%) and decreases of cold-water species (deborealization, 18%). Tropicalization dominated Atlantic sites compared to semi-enclosed basins such as the Mediterranean and Baltic Seas, probably due to physical barrier constraints to connectivity and species colonization. Semi-enclosed basins appeared to be particularly vulnerable to ocean warming, experiencing the fastest rates of warming and biodiversity loss through deborealization.


Assuntos
Biodiversidade , Invertebrados , Animais , Oceanos e Mares , Peixes , Temperatura , Água , Ecossistema , Aquecimento Global
2.
Heart Rhythm O2 ; 5(1): 8-16, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38312208

RESUMO

Background: Conduction system pacing (CSP), either as His bundle pacing (HBP) or as left bundle branch area pacing (LBBAP), may be superior to right ventricular apical or septal pacing. Objective: The study sought to present acute results for a new guiding catheter (Biotronik Selectra 3D) designed for CSP implantations of a retractable screw-in lead (Biotronik Solia S). Methods: The primary endpoint of the prospective, international nonrandomized BIO|MASTER.Selectra 3D study was freedom from catheter-related serious adverse device effects (SADEs) within 1 week of lead implantation. Results: Of 157 enrolled patients, CSP was achieved in 147 (93.6%) patients. No SADEs occurred within 7 days. LBBAP was achieved in 82 patients (45 as crossover from an HBP attempt) and HBP in 65 (44.2%) patients. In centers considering both HBP and LBBAP, the CSP implantation success approached 99%. Successful CSP implantations lasted on average ∼50 minutes (fluoroscopy ∼6 minutes). Most procedures (87.9%) needed only 1 catheter, even after switch from HBP to LBBAP. The catheter's handling was rated largely positive. In patients without bundle branch block, mean QRS duration increased from 106 ms (intrinsic) to 122 ms (CSP) (P = .001). In patients with bundle branch block, mean QRS duration decreased from 151 ms (intrinsic) to 137 ms (CSP) (P = .004). Conclusion: The Selectra 3D catheter is a valuable tool for HBP and LBBAP implantations of the stylet-supported pacemaker leads. When implanters considered both HBP and LBBAP, the success rate was ∼99%. Flexibility to change between different approaches may be advisable in heterogeneous and challenging areas, such as CSP implantations.

3.
ESC Heart Fail ; 11(2): 1228-1235, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38234123

RESUMO

AIMS: Heart failure (HF) is a chronic disease affecting 64 million people worldwide and places a severe burden on society because of its mortality, numerous re-hospitalizations and associated costs. HeartLogic™ is an algorithm programmed into implanted devices incorporating several biometric parameters which aims to predict HF episodes. It provides an index which can be monitored remotely, allowing pre-emptive treatment of congestion to prevent acute decompensation. We aim to assess the impact and security of pre-emptive HF management, guided by the HeartLogic™ index. METHODS AND RESULTS: The HeartLogic™ France Cohort Study is an investigator-initiated, prospective, multi-centre, non-randomized study. Three hundred ten patients with a history of HF (left ventricular ejection fraction ≤40%; or at least one episode of clinical HF with elevated NT-proBNP ≥450 ng/L) and implanted with a cardioverter defibrillator enabling HeartLogic™ index calculation will be included across 10 French centres. The HeartLogic™ index will be monitored remotely for 12 months and in the event of a HeartLogic™ index ≥16, the local investigator will contact the patient for assessment and adjust HF treatment as necessary. The primary endpoint is unscheduled hospitalization for HF. Secondary endpoints are all-cause mortality, cardiovascular death, HF-related death, unscheduled hospitalizations for ventricular or atrial arrhythmia and HeartLogic™ index evolution over time. Blood samples will be collected for biobanking, and quality of life will be assessed. Finally, the safety of a HeartLogic™-triggered strategy for initiating or increasing diuretic therapy will be assessed. A blind and independent committee will adjudicate the events. CONCLUSIONS: The HeartLogic™ France Cohort Study will provide robust real-world data in a cohort of HF patients managed with the HeartLogic™ algorithm allowing pre-emptive treatment of heart failure exacerbations.


Assuntos
Insuficiência Cardíaca , Qualidade de Vida , Humanos , Estudos de Coortes , Volume Sistólico , Estudos Prospectivos , Bancos de Espécimes Biológicos , Função Ventricular Esquerda , Algoritmos
4.
Environ Microbiol ; 26(1): e16548, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38072822

RESUMO

Paramuricea clavata is an ecosystem architect of the Mediterranean temperate reefs that is currently threatened by episodic mass mortality events related to global warming. The microbiome may play an active role in the thermal stress susceptibility of corals, potentially holding the answer as to why corals show differential sensitivity to heat stress. To investigate this, the prokaryotic and eukaryotic microbiome of P. clavata collected from around the Mediterranean was characterised before experimental heat stress to determine if its microbial composition influences the thermal response of the holobiont. We found that members of P. clavata's microeukaryotic community were significantly correlated with thermal stress sensitivity. Syndiniales from the Dino-Group I Clade 1 were significantly enriched in thermally resistant corals, while the apicomplexan corallicolids were significantly enriched in thermally susceptible corals. We hypothesise that P. clavata mortality following heat stress may be caused by a shift from apparent commensalism to parasitism in the corallicolid-coral host relationship driven by the added stress. Our results show the potential importance of corallicolids and the rest of the microeukaryotic community of corals to understanding thermal stress response in corals and provide a useful tool to guide conservation efforts and future research into coral-associated microeukaryotes.


Assuntos
Antozoários , Microbiota , Animais , Antozoários/fisiologia , Recifes de Corais , Microbiota/fisiologia , Resposta ao Choque Térmico , Aquecimento Global , Simbiose/fisiologia
5.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37470443

RESUMO

AIMS: Electro-anatomical mapping may be critical to identify atrial fibrillation (AF) subjects who require substrate modification beyond pulmonary vein isolation (PVI). The objective was to determine correlations between pre-ablation mapping characteristics and 12-month outcomes after a single PVI-only catheter ablation of AF. METHODS AND RESULTS: This study enrolled paroxysmal AF (PAF), early persistent AF (PsAF; 7 days-3 months), and non-early PsAF (>3-12 months) subjects undergoing de novo PVI-only radiofrequency catheter ablation. Sinus rhythm (SR) and AF voltage maps were created with the Advisor HD Grid™ Mapping Catheter, Sensor Enabled™ for each subject, and the presence of low-voltage area (LVA) (low-voltage cutoffs: 0.1-1.5 mV) was investigated. Follow-up visits were at 3, 6, and 12 months, with a 24-h Holter monitor at 12 months. A Cox proportional hazards model identified associations between mapping data and 12-month recurrence after a single PVI procedure. The study enrolled 300 subjects (113 PAF, 86 early PsAF, and 101 non-early PsAF) at 18 centres. At 12 months, 75.5% of subjects were free from AF/atrial flutter (AFL)/atrial tachycardia (AT) recurrence. Univariate analysis found that arrhythmia recurrence did not correlate with AF diagnosis, but LVA was significantly correlated. Low-voltage area (<0.5 mV) >28% of the left atrium in SR [hazard ratio (HR): 4.82, 95% confidence interval (CI): 2.08-11.18; P = 0.0003] and >72% in AF (HR: 5.66, 95% CI: 2.34-13.69; P = 0.0001) was associated with a higher risk of AF/AFL/AT recurrence at 12 months. CONCLUSION: Larger extension of LVA was associated with an increased risk of arrhythmia recurrence. These subjects may benefit from substrate modification beyond PVI.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Frequência Cardíaca , Resultado do Tratamento , Técnicas Eletrofisiológicas Cardíacas , Recidiva , Fatores de Tempo , Átrios do Coração , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Flutter Atrial/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
6.
Heart Rhythm O2 ; 4(7): 448-456, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37520021

RESUMO

Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has demonstrated safety and efficacy for the treatment of malignant ventricular arrhythmias. However, a limitation of the S-ICD lies in the inability to either pace-terminate ventricular tachycardia or provide prolonged bradycardia pacing support. Objective: The rationale and design of a prospective, single-arm, multinational trial of an intercommunicative leadless pacing system integrated with the S-ICD will be presented. Methods: A technical description of the modular cardiac rhythm management (mCRM) system (EMPOWER leadless pacemaker and EMBLEM S-ICD) and the implantation procedure is provided. MODULAR ATP (Effectiveness of the EMPOWER™ Modular Pacing System and EMBLEM™ Subcutaneous ICD to Communicate Antitachycardia Pacing) is a multicenter, international trial enrolling up to 300 patients at risk of sudden cardiac death at up to 60 centers trial design. The safety endpoint of freedom from major complications related to the mCRM system or implantation procedure at 6 months and 2 years are significantly higher than 86% and 81%, respectively, and all-cause survival is significantly >85% at 2 years. Results: Efficacy endpoints are that at 6 months mCRM communication success is significantly higher than 88% and the percentage of subjects with low and stable thresholds is significantly higher than 80%. Substudies to evaluate rate-responsive features and performance of the pacing module are also described. Conclusion: The MODULAR ATP global clinical trial will prospectively test the safety and efficacy of the first intercommunicating leadless pacing system with the S-ICD. This trial will allow for robust validation of device-device communication, pacing performance, rate responsiveness, and system safety.

7.
Ecol Evol ; 13(1): e9740, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36789139

RESUMO

The accurate delimitation of species boundaries in nonbilaterian marine taxa is notoriously difficult, with consequences for many studies in ecology and evolution. Anthozoans are a diverse group of key structural organisms worldwide, but the lack of reliable morphological characters and informative genetic markers hampers our ability to understand species diversification. We investigated population differentiation and species limits in Atlantic (Iberian Peninsula) and Mediterranean lineages of the octocoral genus Paramuricea previously identified as P. clavata. We used a diverse set of molecular markers (microsatellites, RNA-seq derived single-copy orthologues [SCO] and mt-mutS [mitochondrial barcode]) at 49 locations. Clear segregation of Atlantic and Mediterranean lineages was found with all markers. Species-tree estimations based on SCO strongly supported these two clades as distinct, recently diverged sister species with incomplete lineage sorting, P. cf. grayi and P. clavata, respectively. Furthermore, a second putative (or ongoing) speciation event was detected in the Atlantic between two P. cf. grayi color morphotypes (yellow and purple) using SCO and supported by microsatellites. While segregating P. cf. grayi lineages showed considerable geographic structure, dominating circalittoral communities in southern (yellow) and western (purple) Portugal, their occurrence in sympatry at some localities suggests a degree of reproductive isolation. Overall, our results show that previous molecular and morphological studies have underestimated species diversity in Paramuricea occurring in the Iberian Peninsula, which has important implications for conservation planning. Finally, our findings validate the usefulness of phylotranscriptomics for resolving evolutionary relationships in octocorals.

8.
J Interv Card Electrophysiol ; 66(5): 1201-1209, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36459310

RESUMO

BACKGROUND: In patients with cardiac resynchronization therapy defibrillators (CRT-Ds), the need for implantable cardioverter-defibrillator (ICD) back-up may be questionable at time of CRT-D replacement (REP) if ICD implant criteria are no longer met due to an improved left ventricular ejection fraction (LVEF) and if no major ventricular arrhythmic event (VAE) occurred during the CRT-D lifetime. The aim of our study was to assess the relevance of ICD back-up and predictors of VAE after REP in primary prevention CRT-D patients. METHODS: The prospective, observational, international BioCONTINUE study investigated the rate of patients with at least 1 sustained VAE (sVAE) post-REP and searched for predictive factors of sVAE. RESULTS: Two hundred seventy-six patients (70 ± 10 years, 77% men, mean LVEF 40.6 ± 12.6%) were followed for 28.4 ± 10.2 months. The rate of patients with sVAE was 8.3%, 10.3%, and 21.2% at 1, 2, and 4 years post-REP. Patients without persistent ICD indication at REP still had a sVAE rate of 5.7% (95% CI 2.3-11.5%) at 2 years. In multivariate analysis, predictive factors of subsequent sVAE were (i) persistent ICD indication (hazard ratio (HR) 3.6; 95% CI 1.6-8.3; p = 0.003); (ii) 64-72 years of age as compared to ≥ 79 years (HR 3.7; 95% CI 1.4-9.7; p = 0.008); and (iii) ischemic heart disease (HR 4.4; 95% CI 2.1-9.3; p < 0.0001). CONCLUSIONS: The risk of sVAE (21.2% at 4 years post-REP) depends on age, ischemic heart disease, and ICD indication at the time of REP. A non-trivial risk of sVAE remains in patients without persistent ICD indication. CLINICAL TRIAL REGISTRATION: NCT02323503.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Isquemia Miocárdica , Taquicardia Ventricular , Idoso , Feminino , Humanos , Masculino , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Isquemia Miocárdica/terapia , Estudos Prospectivos , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Pessoa de Meia-Idade
9.
Mitochondrial DNA B Resour ; 7(11): 1985-1988, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36406821

RESUMO

The Gray's sea fan, Paramuricea grayi (Johnson, 1861), typically inhabits deep littoral and circalittoral habitats of the eastern temperate and tropical Atlantic Ocean. Along the Iberian Peninsula, where P. grayi is a dominant constituent of circalittoral coral gardens, two segregating lineages (yellow and purple morphotypes) were recently identified using single-copy nuclear orthologues. The mitochondrial genomes of 9 P. grayi individuals covering both color morphotypes were assembled from RNA-seq data, using samples collected at three sites in southern (Sagres and Tavira) and western (Cape Espichel) Portugal. The complete circular mitogenome is 18,668 bp in length, has an A + T-rich base composition (62.5%) and contains the 17 genes typically found in Octocorallia: 14 protein-coding genes (atp6, atp8, cob, cox1-3, mt-mutS, nad1-6, and nad4L), the small and large subunit rRNAs (rns and rnl), and one transfer RNA (trnM). The mitogenomes were nearly identical for all specimens, though we identified a noteworthy polymorphism (two SNPs 9 bp apart) in the mt-mutS of one purple individual that is shared with the sister species P. clavata. The mitogenomes of the two species have a pairwise sequence identity of 99.0%, with nad6 and mt-mutS having the highest rates of non-synonymous substitutions.

10.
Glob Chang Biol ; 28(19): 5708-5725, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35848527

RESUMO

Climate change is causing an increase in the frequency and intensity of marine heatwaves (MHWs) and mass mortality events (MMEs) of marine organisms are one of their main ecological impacts. Here, we show that during the 2015-2019 period, the Mediterranean Sea has experienced exceptional thermal conditions resulting in the onset of five consecutive years of widespread MMEs across the basin. These MMEs affected thousands of kilometers of coastline from the surface to 45 m, across a range of marine habitats and taxa (50 taxa across 8 phyla). Significant relationships were found between the incidence of MMEs and the heat exposure associated with MHWs observed both at the surface and across depths. Our findings reveal that the Mediterranean Sea is experiencing an acceleration of the ecological impacts of MHWs which poses an unprecedented threat to its ecosystems' health and functioning. Overall, we show that increasing the resolution of empirical observation is critical to enhancing our ability to more effectively understand and manage the consequences of climate change.


Assuntos
Organismos Aquáticos , Ecossistema , Mudança Climática , Mar Mediterrâneo
12.
Eur J Heart Fail ; 24(6): 1080-1090, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35490339

RESUMO

AIMS: Cardiac resynchronization therapy (CRT) reduces morbidity and mortality for patients with heart failure, reduced left ventricular ejection fraction, QRS duration >130 ms and in sinus rhythm. The aim of this study was to identify patient characteristics that predict the effect, specifically, of CRT pacemakers (CRT-P) on all-cause mortality or the composite of hospitalization for heart failure or all-cause mortality. METHODS AND RESULTS: We conducted an individual patient data meta-analysis of the Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) and Cardiac Resynchronization-Heart Failure (CARE-HF) trials. Only patients assigned to CRT-P or control (n = 1738) were included in order to avoid confounding from concomitant defibrillator therapy. The influence of baseline characteristics on treatment effects was investigated. Median age was 67 (59-73) years, most patients were men (70%), 68% had a QRS duration of 150-199 ms and 80% had left bundle branch block. Patients assigned to CRT-P had lower rates for all-cause mortality (hazard ratio [HR] 0.68, 95% confidence interval [CI] 0.56-0.81; p < 0.0001) and the composite outcome (HR 0.67, 95% CI 0.58-0.78; p < 0.0001). No pre-specified characteristic, including sex, aetiology of ventricular dysfunction, QRS duration (within the studied range) or morphology or PR interval significantly influenced the effect of CRT-P on all-cause mortality or the composite outcome. However, CRT-P had a greater effect on the composite outcome for patients with lower body surface area and those prescribed beta-blockers. CONCLUSIONS: Cardiac resynchronization therapy-pacemaker reduces morbidity and mortality in appropriately selected patients with heart failure. Benefits may be greater in smaller patients and in those receiving beta-blockers. Neither QRS duration nor morphology independently predicted the benefit of CRT-P. CLINICAL TRIAL REGISTRATION: COMPANION, NCT00180258; CARE-HF, NCT00170300.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Antagonistas Adrenérgicos beta , Idoso , Terapia de Ressincronização Cardíaca/métodos , Desfibriladores , Feminino , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Morbidade , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
13.
Ecol Lett ; 24(5): 1038-1051, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33728823

RESUMO

Quantifying changes in functional community structure driven by disturbance is critical to anticipate potential shifts in ecosystem functioning. However, how marine heatwaves (MHWs) affect the functional structure of temperate coral-dominated communities is poorly understood. Here, we used five long-term (> 10 years) records of Mediterranean coralligenous assemblages in a multi-taxa, trait-based analysis to investigate MHW-driven changes in functional structure. We show that, despite stability in functional richness (i.e. the range of species functional traits), MHW-impacted assemblages experienced long-term directional changes in functional identity (i.e. their dominant trait values). Declining traits included large sizes, long lifespans, arborescent morphologies, filter-feeding strategies or calcified skeletons. These traits, which were mostly supported by few sensitive and irreplaceable species from a single functional group (habitat-forming octocorals), disproportionally influence certain ecosystem functions (e.g. 3D-habitat provision). Hence, MHWs are leading to assemblages that are deficient in key functional traits, with likely consequences for the ecosystem functioning.


Assuntos
Antozoários , Mudança Climática , Animais , Biodiversidade , Ecossistema
14.
Arch Cardiovasc Dis ; 114(2): 140-149, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33478860

RESUMO

Ventricular tachycardia has a significant recurrence rate after ablation for several reasons, including inaccessible substrate. A non-invasive technique to ablate any defined areas of myocardium involved in arrhythmogenesis would be a potentially important therapeutic improvement if shown to be safe and effective. Early feasibility studies of single-fraction stereotactic body radiotherapy have demonstrated encouraging results, but rigorous evaluation and follow-up are required. In this document, the basic concepts of stereotactic body radiotherapy are summarized, before focusing on stereotactic arrhythmia radioablation. We describe the effect of radioablation on cardiac tissue and its interaction with intracardiac devices, depending on the dose. The different clinical studies on ventricular tachycardia radioablation are analysed, with a focus on target identification, which is the key feature of this approach. Our document ends with the indications and requirements for practicing this type of procedure in 2020. Finally, because of the limited number of patients treated so far, we encourage multicentre registries with long-term follow-up.


Assuntos
Ventrículos do Coração/efeitos da radiação , Radiocirurgia , Taquicardia Ventricular/radioterapia , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Animais , Feminino , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Radiocirurgia/efeitos adversos , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento
15.
ESC Heart Fail ; 8(2): 1675-1680, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33465287

RESUMO

AIMS: The SMART (Strategic MAnagement to optimize response to cardiac Resynchronization Therapy) Registry was designed to assess real-world outcomes for patients receiving a cardiac resynchronization therapy defibrillator (CRT-D) and to better understand which programming and optimization techniques are used and how effective they are. METHODS AND RESULTS: The SMART Registry is a global, multicentre, prospective, observational, post-market CRT-D registry with a planned enrolment of 2000 subjects from a maximum of 200 sites in Europe, North America, and Asia-Pacific region. Each subject will be followed up for a minimum of 12 months. The primary endpoint of CRT response rate at 12 months is defined by a clinical composite score of all-cause mortality, heart failure events, New York Heart Association Class, and quality of life as assessed by a patient global assessment instrument. A subgroup composed of the first 103 consecutive European subjects implanted with an NG4 device will have left ventricular multisite pacing feature enabled at any time during the initial 12 months of follow-up. The primary endpoint for this sub-analysis will be the NG4 PG-related complication-free rate at 36 months. CONCLUSIONS: The SMART Registry achieved its recruitment target in August 2019, with 2014 patients enrolled. The baseline demographics demonstrated that patients were generally older, with greater co-morbidity, and on more contemporary medical therapy than in the key CRT trials. The results of the SMART Registry will determine which programming and optimization techniques are effective in this real-world population.


Assuntos
Terapia de Ressincronização Cardíaca , Europa (Continente)/epidemiologia , Humanos , Estudos Prospectivos , Qualidade de Vida , Sistema de Registros
16.
Europace ; 23(1): 73-81, 2021 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-33257972

RESUMO

AIMS: We aimed to provide contemporary real-world data on wearable cardioverter-defibrillator (WCD) use, not only in terms of effectiveness and safety but also compliance and acceptability. METHODS AND RESULTS: Across 88 French centres, the WEARIT-France study enrolled retrospectively patients who used the WCD between May 2014 and December 2016, and prospectively all patients equipped for WCD therapy between January 2017 and March 2018. All patients received systematic education session through a standardized programme across France at the time of initiation of WCD therapy and were systematically enrolled in the LifeVest Network remote services. Overall, 1157 patients were included (mean age 60 ± 12 years, 16% women; 46% prospectively): 82.1% with ischaemic cardiomyopathy, 10.3% after implantable cardioverter-defibrillator explant, and 7.6% before heart transplantation. Median WCD usage period was 62 (37-97) days. Median daily wear time of WCD was 23.4 (22.2-23.8) h. In multivariate analysis, younger age was associated with lower compliance [adjusted odds ratio (OR) 0.97, 95% confidence interval (CI) 0.95-0.99, P < 0.01]. A total of 18 participants (1.6%) received at least one appropriate shock, giving an incidence of appropriate therapy of 7.2 per 100 patient-years. Patient-response button allowed the shock to be aborted in 35.7% of well-tolerated sustained ventricular arrhythmias and in 95.4% of inappropriate ventricular arrhythmia detection, finally resulting in an inappropriate therapy in eight patients (0.7%). CONCLUSION: Our real-life findings reinforce previous studies on the efficacy and safety of the WCD in the setting of transient high-risk group in selected patients. Moreover, they emphasize the fact that when prescribed appropriately, in concert with adequate patient education and dedicated follow-up using specific remote monitoring system, compliance with WCD is high and the device well-tolerated by the patient.


Assuntos
Desfibriladores Implantáveis , Dispositivos Eletrônicos Vestíveis , Idoso , Estudos de Coortes , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
17.
G3 (Bethesda) ; 10(9): 2941-2952, 2020 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-32660973

RESUMO

The octocoral, Paramuricea clavata, is a habitat-forming anthozoan with a key ecological role in rocky benthic and biodiversity-rich communities in the Mediterranean and Eastern Atlantic. Shallow populations of P. clavata in the North-Western Mediterranean are severely affected by warming-induced mass mortality events (MMEs). These MMEs have differentially impacted individuals and populations of P. clavata (i.e., varied levels of tissue necrosis and mortality rates) over thousands of kilometers of coastal areas. The eco-evolutionary processes, including genetic factors, contributing to these differential responses remain to be characterized. Here, we sequenced a P. clavata individual with short and long read technologies, producing 169.98 Gb of Illumina paired-end and 3.55 Gb of Oxford Nanopore Technologies (ONT) reads. We obtained a de novo genome assembly accounting for 607 Mb in 64,145 scaffolds. The contig and scaffold N50s are 19.15 Kb and 23.92 Kb, respectively. Despite of the low contiguity of the assembly, its gene completeness is relatively high, including 75.8% complete and 9.4% fragmented genes out of the 978 metazoan genes contained in the metazoa_odb9 database. A total of 62,652 protein-coding genes have been annotated. This assembly is one of the few octocoral genomes currently available. This is undoubtedly a valuable resource for characterizing the genetic bases of the differential responses to thermal stress and for the identification of thermo-resistant individuals and populations. Overall, having the genome of P. clavata will facilitate studies of various aspects of its evolutionary ecology and elaboration of effective conservation plans such as active restoration to overcome the threats of global change.


Assuntos
Antozoários , Mudança Climática , Animais , Antozoários/genética , Ecossistema , Genoma , Sequenciamento de Nucleotídeos em Larga Escala , Humanos
18.
Arch Cardiovasc Dis ; 113(6-7): 473-484, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32473997

RESUMO

Magnetic resonance imaging (MRI) has become the reference imaging technique for the management of a large number of diseases. The number of MRI examinations increases every year, simultaneously with the number of patients receiving a cardiac electronic implantable device (CEID). The presence of a CEID was considered an absolute contraindication for MRI for many years. The progressive replacement of conventional pacemakers and defibrillators by "magnetic resonance (MR)-conditional" CEIDs and recent data on the safety of MRI in patients with "MR-non-conditional" CEIDs have gradually increased the demand for MRI in patients with a CEID. However, some risks are associated with MRI in CEID carriers, even with MR-conditional devices, because these devices are not "MR safe". Specific programming of the device in "MR mode" and monitoring patients during MRI remain mandatory for all patients with a CEID. A standardized patient workflow based on an institutional protocol should be established in each institution performing such examinations. This joint position paper of the Working Group of Pacing and Electrophysiology of the French Society of Cardiology and the French Society of Diagnostic and Interventional Cardiac and Vascular Imaging describes the effect of and risks associated with MRI in CEID carriers. We propose recommendations for patient workflow and monitoring and CEID programming in MR-conditional, "MR-conditional non-guaranteed" and MR-non-conditional devices.


Assuntos
Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Cardiopatias/terapia , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Estimulação Cardíaca Artificial/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Cardiopatias/fisiopatologia , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Valor Preditivo dos Testes , Desenho de Prótese , Falha de Prótese , Fatores de Risco
19.
Arch Cardiovasc Dis ; 113(8-9): 492-502, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32461091

RESUMO

The population of patients with congenital heart disease (CHD) is continuously increasing, and a significant proportion of these patients will experience arrhythmias because of the underlying congenital heart defect itself or as a consequence of interventional or surgical treatment. Arrhythmias are a leading cause of mortality, morbidity and impaired quality of life in adults with CHD. Arrhythmias may also occur in children with or without CHD. In light of the unique issues, challenges and considerations involved in managing arrhythmias in this growing, ageing and heterogeneous patient population and in children, it appears both timely and essential to critically appraise and synthesize optimal treatment strategies. The introduction of catheter ablation techniques has greatly improved the treatment of cardiac arrhythmias. However, catheter ablation in adults or children with CHD and in children without CHD is more technically demanding, potentially causing various complications, and thus requires a high level of expertise to maximize success rates and minimize complication rates. As French recommendations regarding required technical competence and equipment are lacking in this situation, the Working Group of Pacing and Electrophysiology of the French Society of Cardiology and the Affiliate Group of Paediatric and Adult Congenital Cardiology have decided to produce a common position paper compiled from expert opinions from cardiac electrophysiology and paediatric cardiology. The paper details the features of an interventional cardiac electrophysiology centre that are required for ablation procedures in adults with CHD and in children, the importance of being able to diagnose, monitor and manage complications associated with ablations in these patients and the supplemental hospital-based resources required, such as anaesthesia, surgical back-up, intensive care, haemodynamic assistance and imaging. Lastly, the need for quality evaluations and French registries of ablations in these populations is discussed. The purpose of this consensus statement is therefore to define optimal conditions for the delivery of invasive care regarding ablation of arrhythmias in adults with CHD and in children, and to provide expert and - when possible - evidence-based recommendations on best practice for catheter-based ablation procedures in these specific populations.


Assuntos
Arritmias Cardíacas/cirurgia , Procedimentos Cirúrgicos Cardíacos , Cardiologistas/normas , Serviço Hospitalar de Cardiologia/normas , Ablação por Cateter/normas , Competência Clínica/normas , Criocirurgia/normas , Cardiopatias Congênitas/cirurgia , Adolescente , Adulto , Fatores Etários , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Criança , Pré-Escolar , Consenso , Criocirurgia/efeitos adversos , Criocirurgia/mortalidade , Técnicas Eletrofisiológicas Cardíacas/normas , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/fisiopatologia , Frequência Cardíaca , Humanos , Lactente , Recém-Nascido , Fatores de Risco , Sobreviventes , Resultado do Tratamento , Adulto Jovem
20.
Arch Cardiovasc Dis ; 113(5): 359-366, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32334981

RESUMO

The introduction of a new technology always raises questions about its place compared with the reference technology. The use of an implantable cardioverter defibrillator to prevent sudden cardiac death is now a widely proven technique, with a clear statement of its indication in the guidelines. More recently, a subcutaneous implantable cardioverter defibrillator has been introduced, and appears to be an attractive technique as it removes the need to implant a lead inside the right ventricle to treat the patient, which should dramatically decrease the risk of complications over time. Currently, only one model of subcutaneous implantable cardioverter defibrillator is available on the market; its indications are the same as for transvenous implantable cardioverter defibrillators, except for patients who need stimulation because of conduction disorders or ventricular tachycardias that can potentially be treated effectively by antitachycardia pacing. The different technical characteristics of transvenous versus subcutaneous implantable cardioverter defibrillators therefore raise the question of which to choose in different clinical settings. The experts who participated in the preparation of this manuscript had three meetings, organized by the company Boston Scientific. Each expert prepared the draft of a section corresponding to a clinical situation. The choice between transvenous versus subcutaneous implantable cardioverter defibrillator was then voted on by all the experts. The results of the votes are presented in this manuscript, as it seemed important to us to show the disparities of opinion that can exist in certain situations. The votes were cast independently and anonymously.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Prevenção Primária , Prevenção Secundária , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Tomada de Decisão Clínica , Consenso , Morte Súbita Cardíaca/epidemiologia , Humanos , Seleção de Pacientes , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...