Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Injury ; 54(4): 1082-1087, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36740475

RESUMO

BACKGROUND: The development of a pelvic wound infection in the presence of hardware after open reduction and internal fixation presents a clinical dilemma and there is little literature to aid in decision-making. The purpose of this study was to describe the possibility of debridement, antibiotic pearls and retention of the implant (DAPRI) procedure to eradicate the infection. METHODS: Tumor-like debridement, antibiotic pearls and retention of the implant (DAPRI) aimed to remove the biofilm allowing a higher and prolonged local antibiotic concentration by using calcium sulfate antibiotic-added beads. Wound status, radiological signs of bone healing, gait and functional activity of the patient were evaluated. RESULTS: Seven patients underwent this technique. The mean follow up time was nine months (range: 6 -16 months). Complete wound healing was achieved in all the patients with no major complications. Average time of bony union was 4.3 months (range: 3-6 months) with no need for implant removal. CONCLUSION: The DAPRI technique might represent a safe and more conservative treatment for management of early fracture-related infections (FRI) of the pelvis and acetabulum.


Assuntos
Fraturas do Quadril , Fraturas da Coluna Vertebral , Humanos , Sulfato de Cálcio , Antibacterianos/uso terapêutico , Estudos Retrospectivos , Desbridamento/métodos , Fixação Interna de Fraturas/métodos , Fraturas do Quadril/tratamento farmacológico , Fraturas da Coluna Vertebral/etiologia , Pelve , Resultado do Tratamento
2.
Eur J Orthop Surg Traumatol ; 33(6): 2243-2251, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36539626

RESUMO

PURPOSE: To describe the surgical technique and the outcome of a case series of nonunion and malunion of distal femur fractures treated with an endosteal medial plate combined with a lateral locking plate and with autogenous bone grafting. METHODS: We retrospectively analyzed a series of patients with malunion or nonunion of the distal femur treated with a medial endosteal plate in combination with a lateral locking plate, in a period between January 2011 and December 2019, Database from chart review was obtained including all the clinical relevant available baseline data (demographics, type of fracture, mechanism of injury, time from injury to surgery, number of previous surgical procedures, type of bone graft, and type of lateral plate). Time to bone healing, limb alignment at follow-up and complications were documented. RESULTS: Ten patients were included into the study: 7 male and 3 female with mean age of 48.3 years (range 21-67). The mechanism of trauma was in 8 cases a road traffic accident and in 2 cases a fall from height. According to AO/OTA classification 5 fractures were 33 A3, 3 were 33 C1, 1 was 33 C2 and 1 was 33 C3. The average follow up was 13.5 months. In all cases but one bony union was achieved. Bone healing was observed in average 3.3 months after surgery. No intraoperative or postoperative complications were reported. CONCLUSION: A medial endosteal plate is a useful augmentation for lateral plate fixation in nonunion or malunion following distal femur fractures, particularly in cases of medial bone loss, severe comminution, or poor bone quality. LEVEL OF EVIDENCE: Level IV (retrospective case series).


Assuntos
Fraturas Femorais Distais , Fraturas do Fêmur , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Placas Ósseas , Resultado do Tratamento , Consolidação da Fratura
3.
Arthroscopy ; 39(2): 549-568, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36208710

RESUMO

PURPOSE: To summarize data on the reliability of available imaging criteria for the assessment of trochlear dysplasia and to assess the methodological quality of the included studies. METHODS: This systematic review was conducted following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guideline. Search was performed using major electronic databases from their inception to September 2021. All studies enrolling patients of any age who underwent a radiological exam to rule out features related to trochlear dysplasia were included. After the identification of available imaging criteria, reliability studies were analyzed. Descriptive statistics were used to summarize findings. Methodological quality was assessed using the Quality Appraisal of Reliability studies checklist. RESULTS: A total of 2391 articles were identified, and 33 articles comprising 3036 patients with a mean age of 28.6 years were included. Thirty different measurements were extracted. Magnetic resonance imaging (MRI) was the most used imaging modalities (21 studies), followed by computed tomography (10 studies), conventional radiology (8 studies) and ultrasonography (US) (1 study). Sulcus angle, trochlear depth, and Dejour's classification were the most explored measurements. Overall, sulcus angle can be reliably assessed on radiography, CT and MRI, whereas trochlear depth can be reliably measured only with CT and MRI. Reliability of Dejour's classification ranged from poor or fair to very good for all imaging modalities. Methodological quality of included studies varied from 2 to 9 positive items out of 11 possible. Twenty-four studies (72.7%) were considered at high risk of bias. CONCLUSION: Trochlear dysplasia can be reliably evaluated at least with 3 measurements: sulcus angle, trochlear depth and Dejour's classification. Methodological quality assessment showed high risk of bias in most included studies. LEVEL OF EVIDENCE: Level III, systematic review of Level II-III studies.


Assuntos
Instabilidade Articular , Articulação Patelofemoral , Radiologia , Humanos , Adulto , Reprodutibilidade dos Testes , Fêmur/patologia , Instabilidade Articular/diagnóstico por imagem , Radiografia , Imageamento por Ressonância Magnética , Articulação Patelofemoral/patologia
4.
Orthop Rev (Pavia) ; 14(6): 38572, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36267216

RESUMO

Fragility fractures of the sacrum (FFS) are caused by low-energy trauma in the elderly population. Due to the nuanced symptomatology, many FFS remains unrecognized and the prevalence is underestimated. The clinical presentation varies, typically presenting with weightbearing low back pain without even remembering of a previous trauma. Radiographs are usually insufficient for the diagnosis and second level imaging modalities are required. In particular, magnetic resonance demonstrated the highest diagnostic accuracy. Treatment should aim to guarantee early mobilization and weightbearing, efficient pain relief and early discharge from the hospital to a proper facility for rehabilitation. Conservative treatment is reserved to non-displaced fractures with an adequate pain relief within one week allowing early mobilization. Otherwise, surgical treatment must be preferred. Nowadays, minimally invasive techniques, such as ileo-sacral screws or trans-sacral bar osteosynthesis, are safe and effective procedures and have overcome open procedures. In more complex patterns, with complete dissociation between the pelvic ring and the ilio-lumbar spine, spino-pelvic fixation is the procedure of choice.

5.
World J Orthop ; 3(2): 15-9, 2012 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-22470846

RESUMO

AIM: To measure the forces applied during distraction of growing-rods in early onset scoliosis (EOS), aimed at developing a motorized elongation device. METHODS: A consecutive series of measurements were carried out to analyze the forces applied by the surgeon during distraction of single growing-rods in 10 patients affected by EOS (mean age 8.3 years; range 6 to 10 years) undergoing the first distraction 6 months following implantation of the rods. For each measurement, output from the transducer of a dedicated pair of distraction calipers was recorded at zero load status and at every 1 mm of distraction, up to a maximum of 12 mm for each of the two connected rods. RESULTS: Twenty measurements were obtained showing a linear increase of the load with increasing distraction, with a mean peak force of 485 N at 12 mm distraction and a single reading over 500 N. We did not observe bone fractures or ligament disruptions during or after rod elongations. There was one case of superficial wound infection in the cohort. CONCLUSION: The safe peak force carrying capacity of a motorized device for distraction of growing-rods is 500N.

6.
Spine (Phila Pa 1976) ; 31(14): E441-7, 2006 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-16778673

RESUMO

STUDY DESIGN: Retrospective. OBJECTIVE: To report on the treatment of patients with cerebral palsy and neuropathic scoliosis with third-generation instrumented spinal fusion by Cotrel-Dubousset instrumentation. SUMMARY OF BACKGROUND DATA: Second-generation instrumented spinal fusion is considered the standard for progressive neuropathic scoliosis in cerebral palsy, despite high complication rates. Evidence is needed to evaluate the increasing use of third-generation instrumented spinal fusion in similar patients. METHODS: Patients with cerebral palsy and spinal deformity treated consecutively by 1 surgeon with Cotrel-Dubousset instrumentation and minimum 2-year follow-up were reviewed. An outcome questionnaire was administered at final follow-up. RESULTS: A total of 60 patients were included. Mean age was 15 years at surgery. Mean follow-up was 79 months. There were 26 anteroposterior and 34 posterior-only procedures. Correction of coronal deformity and pelvic obliquity averaged 60% and 40%, respectively. Major complications affected 13.5% of patients, and included implant loosening, deep infection, and pseudarthrosis. Minor complications affected 10% of patients. Outcome questionnaires showed marked improvements in the areas of satisfaction, function, and quality of life after surgery. CONCLUSIONS: Segmental, third-generation instrumented spinal fusion provides lasting correction of spinal deformity and improved quality of life in patients with cerebral palsy and neuropathic scoliosis, with a lower pseudarthrosis rate compared to reports on second-generation instrumented spinal fusion.


Assuntos
Paralisia Cerebral/complicações , Fixadores Internos , Escoliose/etiologia , Escoliose/cirurgia , Fusão Vertebral , Adolescente , Adulto , Criança , Estudos de Coortes , Feminino , Seguimentos , Humanos , Incidência , Infecções/etiologia , Fixadores Internos/efeitos adversos , Masculino , Satisfação do Paciente , Pseudoartrose/epidemiologia , Pseudoartrose/etiologia , Quadriplegia/complicações , Qualidade de Vida , Radiografia , Estudos Retrospectivos , Escoliose/diagnóstico por imagem , Escoliose/fisiopatologia , Fusão Vertebral/efeitos adversos , Inquéritos e Questionários , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...