1.
Med Phys ; 51(2): 809-825, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37477551

RESUMO

BACKGROUND: There is increasing interest in using ultrasound for thermal ablation, histotripsy, and thermal or cavitational enhancement of drug delivery for the treatment of pancreatic cancer. Ultrasonic and thermal modelling conducted as part of the treatment planning process requires acoustic property values for all constituent tissues, but the literature contains no data for the human pancreas. PURPOSE: This study presents the first acoustic property measurements of human pancreatic samples and provides examples of how these properties impact a broad range of ultrasound therapies. METHODS: Data were collected on human pancreatic tissue samples at physiological temperature from 23 consented patients in cooperation with a hospital pathology laboratory. Propagation of ultrasound over the 2.1-4.5 MHz frequency range through samples of various thicknesses and pathologies was measured using a set of custom-built ultrasonic calipers, with the data processed to estimate sound speed and attenuation. The results were used in acoustic and thermal simulations to illustrate the impacts on extracorporeal ultrasound therapies for mild hyperthermia, thermal ablation, and histotripsy implemented with a CE-marked clinical system operating at 0.96 MHz. RESULTS: The mean sound speed and attenuation coefficient values for human samples were well below the range of values in the literature for non-human pancreata, while the human attenuation power law exponents were substantially higher. The simulated impacts on ultrasound mediated therapies for the pancreas indicated that when using the human data instead of the literature average, there was a 30% reduction in median temperature elevation in the treatment volume for mild hyperthermia and 43% smaller volume within a 60°C contour for thermal ablation, all driven by attenuation. By comparison, impacts on boiling and intrinsic threshold histotripsy were minor, with peak pressures changing by less than 15% (positive) and 1% (negative) as a consequence of the counteracting effects of attenuation and sound speed. CONCLUSION: This study provides the most complete set of speed of sound and attenuation data available for the human pancreas, and it reiterates the importance of acoustic material properties in the planning and conduct of ultrasound-mediated procedures, particularly thermal therapies.


Assuntos
Neoplasias Pancreáticas , Terapia por Ultrassom , Humanos , Som , Ultrassonografia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/terapia , Pâncreas/diagnóstico por imagem
2.
ACS Appl Bio Mater ; 6(12): 5746-5758, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38048163

RESUMO

Delivering cargo to the cell membranes of specific cell types in the body is a major challenge for a range of treatments, including immunotherapy. This study investigates employing protein-decorated microbubbles (MBs) and ultrasound (US) to "tag" cellular membranes of interest with a specific protein. Phospholipid-coated MBs were produced and functionalized with a model protein using a metallochelating complex through an NTA(Ni) and histidine residue interaction. Successful "tagging" of the cellular membrane was observed using microscopy in adherent cells and was promoted by US exposure. Further modification of the MB surface to enable selective binding to target cells was then achieved by functionalizing the MBs with a targeting protein (transferrin) that specifically binds to a receptor on the target cell membrane. Attachment and subsequent transfer of material from MBs functionalized with transferrin to the target cells significantly increased, even in the absence of US. This work demonstrates the potential of these MBs as a platform for the noninvasive delivery of proteins to the surface of specific cell types.


Assuntos
Microbolhas , Fosfolipídeos , Ultrassonografia , Membrana Celular/metabolismo , Transferrinas/metabolismo
3.
Artigo em Inglês | MEDLINE | ID: mdl-36112556

RESUMO

Nonlinear ultrasonic emissions produced during a therapeutic ultrasound procedure can be detected, localized, and quantified through a class of methods that can be referred to as passive acoustic mapping (PAM). While a variety of PAM beamforming algorithms may be employed, they share a common limitation that a single sound speed is specified for both phase steering of array elements and for calculation of source power or energy. The specified value may be inadequate whether derived from B-mode-based metrics or literature values for constituent materials. This study employed experiments and simulations with linear and curvilinear array geometries to investigate the impact of in situ sound speed uncertainties on source localization in layered media. The data were also used to evaluate a new method for optimizing coregistration of PAM and B-mode images. Coregistration errors as large as 10 mm were observed with the curvilinear array, which also showed much greater sound speed sensitivity than the linear array. Errors with both array geometries were typically reduced to the order of 0.1 mm using the proposed optimization method regardless of beamformer choice or whether the array was calibrated. In a further step toward reliable implementation of PAM, the current work provides an approach that can help ensure that therapeutic ultrasound procedures are accurately guided by cavitation emissions.


Assuntos
Acústica , Terapia por Ultrassom , Terapia por Ultrassom/métodos , Ultrassonografia/métodos , Algoritmos , Som
4.
Ultrasound Med Biol ; 47(6): 1596-1615, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33707089

RESUMO

In this study we compared three different microbubble-based approaches to the delivery of a widely used chemotherapy drug, gemcitabine: (i) co-administration of gemcitabine and microbubbles (Gem+MB); (ii) conjugates of microbubbles and gemcitabine-loaded liposomes (GemlipoMB); and (iii) microbubbles with gemcitabine directly bound to their surfaces (GembioMB). Both in vitro and in vivo investigations were carried out, respectively, in the RT112 bladder cancer cell line and in a murine orthotopic muscle-invasive bladder cancer model. The in vitro (in vivo) ultrasound exposure conditions were a 1 (1.1) MHz centre frequency, 0.07 (1.0) MPa peak negative pressure, 3000 (20,000) cycles and 100 (0.5) Hz pulse repetition frequency. Ultrasound exposure produced no significant increase in drug uptake either in vitro or in vivo compared with the drug-only control for co-administered gemcitabine and microbubbles. In vivo, GemlipoMB prolonged the plasma circulation time of gemcitabine, but only GembioMB produced a statistically significant increase in cleaved caspase 3 expression in the tumor, indicative of gemcitabine-induced apoptosis.


Assuntos
Antimetabólitos Antineoplásicos/administração & dosagem , Antimetabólitos Antineoplásicos/farmacocinética , Desoxicitidina/análogos & derivados , Sistemas de Liberação de Medicamentos/métodos , Microbolhas , Terapia por Ultrassom , Neoplasias da Bexiga Urinária/metabolismo , Neoplasias da Bexiga Urinária/terapia , Animais , Antimetabólitos Antineoplásicos/uso terapêutico , Desoxicitidina/administração & dosagem , Desoxicitidina/farmacocinética , Desoxicitidina/uso terapêutico , Modelos Animais de Doenças , Feminino , Camundongos , Camundongos Nus , Células Tumorais Cultivadas , Gencitabina
5.
Artigo em Inglês | MEDLINE | ID: mdl-32845836

RESUMO

Passive acoustic mapping (PAM) techniques have been developed for the purposes of detecting, localizing, and quantifying cavitation activity during therapeutic ultrasound procedures. Implementation with conventional diagnostic ultrasound arrays has allowed planar mapping of bubble acoustic emissions to be overlaid with B-mode anatomical images, with a variety of beamforming approaches providing enhanced resolution at the cost of extended computation times. However, no passive signal processing techniques implemented to date have overcome the fundamental physical limitation of the conventional diagnostic array aperture that results in point spread functions with axial/lateral beamwidth ratios of nearly an order of magnitude. To mitigate this problem, the use of a pair of orthogonally oriented diagnostic arrays was recently proposed, with potential benefits arising from the substantially expanded range of observation angles. This article presents experiments and simulations intended to demonstrate the performance and limitations of the dual-array system concept. The key finding of this study is that source pair resolution of better than 1 mm is now possible in both dimensions of the imaging plane using a pair of 7.5-MHz center frequency conventional arrays at a distance of 7.6cm. With an eye toward accelerating computations for real-time applications, channel count reductions of up to a factor of eight induce negligible performance losses. Modest sensitivities to sound speed and relative array position uncertainties were identified, but if these can be kept on the order of 1% and 1 mm, respectively, then the proposed methods offer the potential for a step improvement in cavitation monitoring capability.


Assuntos
Acústica , Terapia por Ultrassom , Processamento de Sinais Assistido por Computador , Som , Ultrassonografia
6.
J Control Release ; 317: 23-33, 2020 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-31733295

RESUMO

Recent pre-clinical studies have demonstrated the potential of combining chemotherapy and sonodynamic therapy for the treatment of pancreatic cancer. Oxygen-loaded magnetic microbubbles have been explored as a targeted delivery vehicle for this application. Despite preliminary positive results, a previous study identified a significant practical challenge regarding the co-alignment of the magnetic and ultrasound fields. The aim of this study was to determine whether this challenge could be addressed through the use of a magnetic-acoustic device (MAD) combining a magnetic array and ultrasound transducer in a single unit, to simultaneously concentrate and activate the microbubbles at the target site. in vitro experiments were performed in tissue phantoms and followed by in vivo treatment of xenograft pancreatic cancer (BxPC-3) tumours in a murine model. In vitro, a 1.4-fold (p < .01) increase in the deposition of a model therapeutic payload within the phantom was achieved using the MAD compared to separate magnetic and ultrasound devices. In vivo, tumours treated with the MAD had a 9% smaller mean volume 8 days after treatment, while tumours treated with separate devices or microbubbles alone were respectively 45% and 112% larger. This substantial and sustained decrease in tumour volume suggests that the proposed drug delivery approach has the potential to be an effective neoadjuvant therapy for pancreatic cancer patients.


Assuntos
Microbolhas , Neoplasias Pancreáticas , Acústica , Animais , Sistemas de Liberação de Medicamentos , Humanos , Fenômenos Magnéticos , Camundongos , Neoplasias Pancreáticas/tratamento farmacológico
7.
J Acoust Soc Am ; 146(1): EL78, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31370617

RESUMO

Passive acoustic mapping (PAM) techniques offer a simple means of spatio-temporal cavitation monitoring during therapeutic ultrasound procedures. Implementation with a conventional diagnostic ultrasound system allows natural integration of PAM with B-mode imaging. However, the refracting properties of diagnostic array lenses may introduce PAM image registration errors that could lead to inaccuracies in treatment monitoring and guidance. To address these concerns, this paper presents lens characterization of two different array designs, analytical estimation of lens-induced source mapping errors in simple media, and experimental demonstration and correction of lens effects, reducing the depth-averaged image co-registration errors to no more than 0.52 mm.

8.
Radiology ; 291(1): 232-238, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30644817

RESUMO

Purpose To demonstrate the feasibility and safety of using focused ultrasound planning models to determine the treatment parameters needed to deliver volumetric mild hyperthermia for targeted drug delivery without real-time thermometry. Materials and Methods This study was part of the Targeted Doxorubicin, or TARDOX, phase I prospective trial of focused ultrasound-mediated, hyperthermia-triggered drug delivery to solid liver tumors ( ClinicalTrials.gov identifier NCT02181075). Ten participants (age range, 49-68 years; average age, 60 years; four women) were treated from March 2015 to March 2017 by using a clinically approved focused ultrasound system to release doxorubicin from lyso-thermosensitive liposomes. Ultrasonic heating of target tumors (treated volume: 11-73 cm3 [mean ± standard deviation, 50 cm3 ± 26]) was monitored in six participants by using a minimally invasive temperature sensor; four participants were treated without real-time thermometry. For all participants, CT images were used with a patient-specific hyperthermia model to define focused ultrasound treatment plans. Feasibility was assessed by comparing model-prescribed focused ultrasound powers to those implemented for treatment. Safety was assessed by evaluating MR images and biopsy specimens for evidence of thermal ablation and monitoring adverse events. Results The mean difference between predicted and implemented treatment powers was -0.1 W ± 17.7 (n = 10). No evidence of focused ultrasound-related adverse effects, including thermal ablation, was found. Conclusion In this 10-participant study, the authors confirmed the feasibility of using focused ultrasound-mediated hyperthermia planning models to define treatment parameters that safely enabled targeted, noninvasive drug delivery to liver tumors while monitored with B-mode guidance and without real-time thermometry. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Dickey and Levi-Polyachenko in this issue.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Doxorrubicina/administração & dosagem , Hipertermia Induzida/métodos , Neoplasias Hepáticas/terapia , Terapia por Ultrassom/métodos , Idoso , Sistemas de Liberação de Medicamentos , Liberação Controlada de Fármacos , Estudos de Viabilidade , Feminino , Humanos , Lipossomos , Masculino , Pessoa de Meia-Idade , Veículos Farmacêuticos , Estudos Prospectivos
9.
Artigo em Inglês | MEDLINE | ID: mdl-30130184

RESUMO

Several active and passive techniques have been developed to detect, localize, and quantify cavitation activity during therapeutic ultrasound procedures. Much of the prior cavitation monitoring research has been conducted using lossless in vitro systems or small animal models in which path attenuation effects were minimal. However, the performance of these techniques may be substantially degraded by attenuation between the internal therapeutic target and the external monitoring system. As a further step toward clinical application of passive acoustic mapping (PAM), this paper presents methods for attenuation estimation and compensation based on broadband cavitation data measured with a linear ultrasound array. Soft tissue phantom experiment results are used to illustrate: 1) the impact of realistic attenuation on PAM; 2) the possibility of estimating attenuation from cavitation data; 3) cavitation source energy estimation following attenuation compensation; and 4) the impact of sound speed uncertainty on PAM-related processing. Cavitation-based estimates of attenuation were within 1.5%-6.2% of the values found from conventional through-transmission measurements. Tissue phantom attenuation reduced the PAM energy estimate by an order of magnitude, but array data compensation using the cavitation-based attenuation spectrum enabled recovery of the PAM energy estimate to within 2.9%-5.9% of the values computed in the absence of the phantom. Sound speed uncertainties were found to modestly impact attenuation-compensated PAM energies, inducing errors no larger than 28% for a 40-m/s path-averaged speed error. Together, the results indicate the potential to significantly enhance the quantitative capabilities of PAM for ensuring therapeutic safety and efficacy.

10.
IEEE Trans Med Imaging ; 37(12): 2582-2592, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29994701

RESUMO

Sources of nonlinear acoustic emissions, particularly those associated with cavitation activity, play a key role in the safety and efficacy of current and emerging therapeutic ultrasound applications, such as oncological drug delivery, blood-brain barrier opening, and histotripsy. Passive acoustic mapping (PAM) is the first technique to enable real-time and non-invasive imaging of cavitation activity during therapeutic ultrasound exposure, through the recording and passive beamforming of broadband acoustic emissions using an array of ultrasound detectors. Initial limitations in PAM spatial resolution led to the adoption of optimal data-adaptive beamforming algorithms, such as the robust capon beamformer (RCB), that provide improved interference suppression and calibration error mitigation compared to non-adaptive beamformers. However, such approaches are restricted by the assumption that the recorded signals have a Gaussian distribution. To overcome this limitation and further improve the source resolvability of PAM, we propose a new beamforming approach termed robust beamforming by linear programming (RLPB). Along with the variance, this optimization-based method uses higher-order-statistics of the recorded signals, making no prior assumption on the statistical distribution of the acoustic signals. The RLPB is found via numerical simulations to improve resolvability over time exposure acoustics and RCB. In vitro experimentation yielded improved resolvability with respect to the source-to-array distance on the order of 22% axially and 13% transversely relative to RCB, whilst successfully accounting for array calibration errors. The improved resolution and decreased dependence on accurate calibration of RLPB is expected to facilitate the clinical translation of PAM for diagnostic, including super-resolution, and therapeutic ultrasound applications.


Assuntos
Algoritmos , Terapia por Ultrassom/métodos , Ultrassonografia/métodos , Simulação por Computador , Desenho de Equipamento , Processamento de Sinais Assistido por Computador , Transdutores , Terapia por Ultrassom/instrumentação , Ultrassonografia/instrumentação
11.
Lancet Oncol ; 19(8): 1027-1039, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30001990

RESUMO

BACKGROUND: Previous preclinical research has shown that extracorporeal devices can be used to enhance the delivery and distribution of systemically administered anticancer drugs, resulting in increased intratumoural concentrations. We aimed to assess the safety and feasibility of targeted release and enhanced delivery of doxorubicin to solid tumours from thermosensitive liposomes triggered by mild hyperthermia, induced non-invasively by focused ultrasound. METHODS: We did an open-label, single-centre, phase 1 trial in a single UK hospital. Adult patients (aged ≥18 years) with unresectable and non-ablatable primary or secondary liver tumours of any histological subtype were considered for the study. Patients received a single intravenous infusion (50 mg/m2) of lyso-thermosensitive liposomal doxorubicin (LTLD), followed by extracorporeal focused ultrasound exposure of a single target liver tumour. The trial had two parts: in part I, patients had a real-time thermometry device implanted intratumourally, whereas patients in part II proceeded without thermometry and we used a patient-specific model to predict optimal exposure parameters. We assessed tumour biopsies obtained before and after focused ultrasound exposure for doxorubicin concentration and distribution. The primary endpoint was at least a doubling of total intratumoural doxorubicin concentration in at least half of the patients treated, on an intention-to-treat basis. This study is registered with ClinicalTrials.gov, number NCT02181075, and is now closed to recruitment. FINDINGS: Between March 13, 2015, and March 27, 2017, ten patients were enrolled in the study (six patients in part I and four in part II), and received a dose of LTLD followed by focused ultrasound exposure. The treatment resulted in an average increase of 3·7 times in intratumoural biopsy doxorubicin concentrations, from an estimate of 2·34 µg/g (SD 0·93) immediately after drug infusion to 8·56 µg/g (5·69) after focused ultrasound. Increases of two to ten times were observed in seven (70%) of ten patients, satisfying the primary endpoint. Serious adverse events registered were expected grade 4 transient neutropenia in five patients and prolonged hospital stay due to unexpected grade 1 confusion in one patient. Grade 3-4 adverse events recorded were neutropenia (grade 3 in one patient and grade 4 in five patients), and grade 3 anaemia in one patient. No treatment-related deaths occurred. INTERPRETATION: The combined treatment of LTLD and non-invasive focused ultrasound hyperthermia in this study seemed to be clinically feasible, safe, and able to enhance intratumoural drug delivery, providing targeted chemo-ablative response in human liver tumours that were refractory to standard chemotherapy. FUNDING: Oxford Biomedical Research Centre, National Institute for Health Research.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Doxorrubicina/análogos & derivados , Hipertermia Induzida , Neoplasias Hepáticas/tratamento farmacológico , Ultrassonografia , Idoso , Doxorrubicina/administração & dosagem , Sistemas de Liberação de Medicamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polietilenoglicóis/administração & dosagem
12.
Artigo em Inglês | MEDLINE | ID: mdl-29389657

RESUMO

Over the last decade, a variety of noninvasive techniques have been developed to monitor therapeutic ultrasound procedures in support of safety or efficacy assessments. One class of methods employs diagnostic ultrasound arrays to sense acoustic emissions, thereby providing a means to passively detect, localize, and quantify the strength of nonlinear sources, including cavitation. Real array element diffraction patterns may differ substantially from those presumed in existing beamforming algorithms. However, diffraction compensation has received limited treatment in passive and active imaging, and measured diffraction data have yet to be used for array response correction. The objectives of this paper were to identify differences between ideal and real element diffraction patterns, and to quantify the impact of diffraction correction on cavitation mapping beamformer performance. These objectives were addressed by performing calibration measurements on a diagnostic linear array, using the results to calculate diffraction correction terms, and applying the corrections to cavitation emission data collected from soft tissue phantom experiments. Measured diffraction patterns were found to differ significantly from those of ideal element forms, particularly at higher frequencies and shorter distances from the array. Diffraction compensation of array data resulted in cavitation energy estimates elevated by as much as a factor of 5, accompanied by the elimination of a substantial bias between two established beamforming algorithms. These results illustrate the importance of using measured array responses to validate analytical field models and to minimize observation biases in imaging applications where quantitative analyses are critical for assessment of therapeutic safety and efficacy.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia/métodos , Algoritmos , Calibragem , Imagens de Fantasmas , Reprodutibilidade dos Testes
13.
Adv Healthc Mater ; 7(5)2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29205931

RESUMO

Exposure of carbon-black (CB) nanoparticles to near-infrared nanosecond-pulsed laser energy can cause efficient intracellular delivery of molecules by photoporation. Here, cellular bioeffects of multi-walled carbon nanotubes (MWCNTs) and single-walled carbon nanotubes (SWCNTs) are compared to those of CB nanoparticles. In DU145 prostate-cancer cells, photoporation using CB nanoparticles transitions from (i) cells with molecular uptake to (ii) nonviable cells to (iii) fragmented cells with increasing laser fluence, as seen previously. In contrast, photoporation with MWCNTs causes uptake and, at higher fluence, fragmentation, but does not generate nonviable cells, and SWCNTs show little evidence of bioeffects, except at extreme laser conditions, which generate nonviable cells and fragmentation, but no significant uptake. These different behaviors cannot be explained by photoacoustic pressure output from the particles. All particle types emit a single, ≈100 ns, mostly positive-pressure pulse that increases in amplitude with laser fluence. Different particle types emit different peak pressures, which are highest for SWCNTs, followed by CB nanoparticles and then MWCNTs, which does not correlate with cellular bioeffects between different particle types. This study concludes that cellular bioeffects depend strongly on the type of carbon nanoparticle used during photoporation and that photoacoustic pressure is unlikely to play a direct mechanistic role in the observed bioeffects.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Nanotubos de Carbono/química , Técnicas Fotoacústicas , Neoplasias da Próstata/tratamento farmacológico , Fuligem , Linhagem Celular Tumoral , Humanos , Masculino , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/patologia , Fuligem/química , Fuligem/farmacologia
14.
J Acoust Soc Am ; 141(2): EL83, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28253670

RESUMO

In vivo ultrasonic attenuation was estimated for extracranial soft tissues of two Tursiops truncatus and one Delphinapterus leucas. Backscatter data was non-invasively collected as part of routine health-based ultrasound examinations using a transducer operating in the 1.6-3.7 MHz frequency range. Data collected over the proximal mandible and temporal regions was processed to yield attenuation estimates using a reference tissue phantom whose properties had been independently determined. The estimated attenuations were at the low end of the range of literature-reported values for mammalian fatty and connective tissues. A companion model-based analysis quantified errors arising from tissue composition and sound speed uncertainties.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Beluga , Golfinho Nariz-de-Garrafa , Tecido Conjuntivo/diagnóstico por imagem , Ultrassonografia , Animais , Feminino , Masculino , Movimento (Física) , Imagens de Fantasmas , Espalhamento de Radiação , Transdutores , Ondas Ultrassônicas , Ultrassonografia/instrumentação
15.
Biophys J ; 112(6): 1258-1269, 2017 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-28355552

RESUMO

Previous studies have shown that exposure of carbon black nanoparticles to nanosecond pulsed near-infrared laser causes intracellular delivery of molecules through hypothesized transient breaks in the cell membrane. The goal of this study is to determine the underlying mechanisms of sequential energy transfer from laser light to nanoparticle to fluid medium to cell. We found that laser pulses on a timescale of 10 ns rapidly heat carbon nanoparticles to temperatures on the order of 1200 K. Heat is transferred from the nanoparticles to the surrounding aqueous medium on a similar timescale, causing vaporization of the surrounding water and generation of acoustic emissions. Nearby cells can be impacted thermally by the hot bubbles and mechanically by fluid mechanical forces to transiently increase cell membrane permeability. The experimental and theoretical results indicate that transfer of momentum and/or heat from the bubbles to the cells are the dominant mechanisms of energy transfer that results in intracellular uptake of molecules. We further conclude that neither thermal expansion of the nanoparticles nor a carbon-steam chemical reaction play a significant role in the observed effects on cells, and that acoustic pressure appears to be concurrent with, but not essential to, the observed bioeffects.


Assuntos
Transferência de Energia , Espaço Intracelular/metabolismo , Lasers , Nanopartículas , Fuligem/química , Fuligem/metabolismo , Transporte Biológico , Linhagem Celular Tumoral , Temperatura Alta , Humanos , Pressão
16.
Adv Exp Med Biol ; 875: 363-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26610980

RESUMO

In this paper, we discuss the issues encountered when trying to perform hearing experiments in water-filled tanks that are several meters in lateral extent, typically large in terms of the size of the animals under study but not necessarily so with respect to the wavelengths of interest. This paper presents measurements of pressure and particle motion fields in these "large" tanks. The observed characteristics and complexities are discussed in reference to their potential impact on the planning and interpretation of hearing experiments.


Assuntos
Acústica , Pesqueiros , Animais , Peixes , Pressão
17.
Adv Exp Med Biol ; 875: 933-41, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26611052

RESUMO

Researchers often perform hearing studies on fish in small tanks. The acoustic field in such a tank is considerably different from the acoustic field that occurs in the animal's natural environment. The significance of these differences is magnified by the nature of the fish's auditory system where either acoustic pressure (a scalar), acoustic particle velocity (a vector), or both may serve as the stimulus. It is essential for the underwater acoustician to understand the acoustics of small tanks to be able to carry out valid auditory research in the laboratory and to properly compare and interpret the results of others.


Assuntos
Acústica , Pesqueiros , Animais , Limiar Auditivo/fisiologia , Audição/fisiologia , Modelos Teóricos , Pressão , Salmo salar/fisiologia
18.
Artigo em Inglês | MEDLINE | ID: mdl-25732931

RESUMO

Pacific bluefin tuna (Thunnus orientalis) is a highly migratory, commercially valuable species potentially vulnerable to acoustic noise generated from human activities which could impact behavior and fitness. Although significant efforts have been made to understand hearing abilities of fishes, the large size and need to continuously swim for respiration have hindered investigations with tuna and other large pelagic species. In this study, Pacific bluefin tuna were trained to respond to a pure tone sound stimulus ranging 325-800 Hz and their hearing abilities quantified using a staircase psychophysical technique. Hearing was most sensitive from 400 to 500 Hz in terms of particle motion (radial acceleration -88 dB re 1 m s(-2); vertical acceleration -86 dB re 1 m s(-2)) and sound pressure (83 dB re 1 µPa). Compared to yellowfin tuna (Thunnus albacares) and kawakawa (Euthynnus affinis), Pacific bluefin tuna has a similar bandwidth of hearing and best frequency, but greater sensitivity overall. Careful calibration of the sound stimulus and experimental tank environment, as well as the adoption of behavioral methodology, demonstrates an experimental approach highly effective for the study of large fish species in the laboratory.


Assuntos
Limiar Auditivo/fisiologia , Audição/fisiologia , Percepção de Movimento/fisiologia , Natação/fisiologia , Atum/fisiologia , Estimulação Acústica , Animais , Oceano Pacífico , Psicoacústica , Especificidade da Espécie
19.
J Exp Biol ; 217(Pt 12): 2078-88, 2014 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-24675557

RESUMO

We investigated the roles of the swim bladder and the lateral line system in sound localization behavior by the plainfin midshipman fish (Porichthys notatus). Reproductive female midshipman underwent either surgical deflation of the swim bladder or cryoablation of the lateral line and were then tested in a monopolar sound source localization task. Fish with nominally 'deflated' swim bladders performed similar to sham-deflated controls; however, post-experiment evaluation of swim bladder deflation revealed that a majority of 'deflated' fish (88%, seven of the eight fish) that exhibited positive phonotaxis had partially inflated swim bladders. In total, 95% (21/22) of fish that localized the source had at least partially inflated swim bladders, indicating that pressure reception is likely required for sound source localization. In lateral line experiments, no difference was observed in the proportion of females exhibiting positive phonotaxis with ablated (37%) versus sham-ablated (47%) lateral line systems. These data suggest that the lateral line system is likely not required for sound source localization, although this system may be important for fine-tuning the approach to the sound source. We found that midshipman can solve the 180 deg ambiguity of source direction in the shallow water of our test tank, which is similar to their nesting environment. We also found that the potential directional cues (phase relationship between pressure and particle motion) in shallow water differs from a theoretical free-field. Therefore, the general question of how fish use acoustic pressure cues to solve the 180 deg ambiguity of source direction from the particle motion vector remains unresolved.


Assuntos
Sacos Aéreos/fisiologia , Batracoidiformes/fisiologia , Sistema da Linha Lateral/fisiologia , Localização de Som , Animais , California , Sinais (Psicologia) , Feminino , Movimento (Física) , Pressão
20.
Res Social Adm Pharm ; 10(1): 156-67, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-23746420

RESUMO

BACKGROUND: Observational data are useful for studying drug safety; however, to be effective, accurate outcome measurement is paramount. OBJECTIVES: This study compared alternative outcome definitions for acute liver injury (ALI) and explored opportunities for improving ALI identification in observational data. METHODS: The Truven MarketScan® Lab Database (MSLR) was used to identify patients meeting at least 1 of 4 ALI definitions, including definitions based on diagnosis codes, laboratory measures, or combinations of diagnoses, procedures, and/or laboratory measures. Expert panelists reviewed patient data using a Web dashboard. Panelists determined whether they believed the patient had ALI and identified factors influencing their decision. Logistic regression models explored which factors were influential in case determination. RESULTS: Overall, only 37 of 208 reviewed patients (17.8%) were classified as cases. The diagnosis-based definition yielded no positive cases and the laboratory-based definition yielded the most positive cases (31 of 60). The most influential factors in case classification were occurrence of procedures after the index date (OR = 13.2, 95% CI = 5.3-32.9), no occurrence of drug treatments before the index date (OR = 4.6; 95% CI = 1.6-13.2), occurrence of drug treatments before the index date (OR = 0.3; 95% CI = 0.1-0.6), and no drug treatments after the index date (OR = 0.2; 95% CI = 0.0-0.5). CONCLUSIONS: Comparing ALI definitions illustrated tradeoffs between the number of plausible cases identified and the likelihood of cases being classified as positive. Future research should refine ALI case definitions, considering the import of laboratory results, procedures, and drugs in defining a case.


Assuntos
Doença Hepática Induzida por Substâncias e Drogas/diagnóstico , Coleta de Dados/métodos , Avaliação de Resultados em Cuidados de Saúde/métodos , Doença Hepática Induzida por Substâncias e Drogas/epidemiologia , Bases de Dados Factuais , Tomada de Decisões , Humanos , Internet , Modelos Logísticos