Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 110
Filtrar
1.
IEEE Trans Biomed Eng ; 70(9): 2540-2551, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37028021

RESUMO

OBJECTIVE: Development of a contact microphone-driven screening framework for the diagnosis of coexisting valvular heart diseases (VHDs). METHODS: A sensitive accelerometer contact microphone (ACM) is employed to capture heart-induced acoustic components on the chest wall. Inspired by the human auditory system, ACM recordings are initially transformed into Mel-frequency cepstral coefficients (MFCCs) and their first and second derivatives, resulting in 3-channel images. An image-to-sequence translation network based on the convolution-meets-transformer (CMT) architecture is then applied to each image to find local and global dependencies in images, and predict a 5-digit binary sequence, where each digit corresponds to the presence of a specific type of VHD. The performance of the proposed framework is evaluated on 58 VHD patients and 52 healthy individuals using a 10-fold leave-subject-out cross-validation (10-LSOCV) approach. RESULTS: Statistical analyses suggest an average sensitivity, specificity, accuracy, positive predictive value, and F1 score of 93.28%, 98.07%, 96.87%, 92.97%, and 92.4% respectively, for the detection of coexisting VHDs. Furthermore, areas under the curve (AUC) of 0.99 and 0.98 are respectively reported for the validation and test sets. CONCLUSION: The high performances achieved prove that local and global features of ACM recordings effectively characterize heart murmurs associated with valvular abnormalities. SIGNIFICANCE: Limited access of primary care physicians to echocardiography machines has resulted in a low sensitivity of 44% when using a stethoscope for the identification of heart murmurs. The proposed framework provides accurate decision-making on the presence of VHDs, thus reducing the number of undetected VHD patients in primary care settings.


Assuntos
Doenças das Valvas Cardíacas , Humanos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Sopros Cardíacos/diagnóstico , Auscultação Cardíaca , Ecocardiografia , Valor Preditivo dos Testes
2.
J Endovasc Ther ; 30(5): 711-720, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-35503774

RESUMO

PURPOSE: To investigate the clinical implication of additional below-the-ankle (BTA) intervention in patients with chronic limb-threatening ischemia (CLTI) undergoing below-the-knee (BTK) intervention. MATERIALS AND METHODS: A sub-analysis was performed using data from the LIBERTY trial (ClinicalTrials.gov identifier NCT01855412), a prospective, observational, core-laboratory adjudicated, multicenter study of endovascular intervention in 1204 patients. Patients with CLTI (Rutherford Classification 4-6) who underwent BTK intervention were included in this sub-analysis. Participants were then stratified into 2 treatment groups according to whether at least one lesion intervened on was BTA (n=66) or not (n=273). The decision on whether and where to intervene was made during the procedure. The main outcome measures included major amputation, target vessel revascularization (TVR), major adverse events (MAE), survival, amputation-free survival, major adverse limb events or peri-operative death (MALE-POD), and all-cause death. Other outcome measures included procedural success, procedural complications, and wound healing rate. RESULTS: There were no differences in procedural success or severe angiographic complications between the 2 groups. At 1-year post-procedure, patients in the BTK group had a higher rate of freedom from major amputation (95.0% vs. 86.9%, respectively; HR: 2.87, 95% CI: 1.17-7.03), a higher rate of freedom from TVR (80.1% vs. 66.9%, respectively; HR: 1.94, 95% CI: 1.14-3.32), a higher rate of freedom from MALE-POD (94.6% vs. 86.9%, respectively; HR: 2.65, 95% CI: 1.10-6.41), and a higher rate of freedom from MAE at both 1 (76.0% vs. 60.1%, respectively; HR: 2.00, 95% CI: 1.24-3.22) and 3 years post procedure (67.5% vs. 55.8%, respectively; HR: 1.69, 95% CI: 1.08-2.65). There was a significantly lower rate of survival in the BTK group at 3 years (74.3% vs. 91.1%, respectively; HR: 0.35, 95% CI: 0.14-0.87). After risk adjustment, there was a higher rate of all-cause death in the BTK group at 3 years (19.4% vs. 9.1%, respectively; p=0.023) post-intervention. CONCLUSION: Patients with disease requiring intervention to BTA lesions have a potential increased amputation rate in the short term, but BTA intervention carries a potential survival benefit in the long term when compared to BTK intervention alone.


Assuntos
Tornozelo , Extremidade Inferior , Humanos , Estudos Prospectivos , Resultado do Tratamento , Extremidade Inferior/irrigação sanguínea , Cicatrização
3.
IEEE J Biomed Health Inform ; 27(1): 274-285, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36318550

RESUMO

OBJECTIVE: The development of an accurate, non-invasive method for the diagnosis of peripheral artery disease (PAD) from accelerometer contact microphone (ACM) recordings of the cardiac system. METHODS: Mel frequency cepstral coefficients (MFCCs) are initially extracted from ACM recordings. The extracted MFCCs are then used to fine-tune a pre-trained ResNet50 network whose middle layers provide streams of high-level-of-abstraction coefficients (HLACs) which could provide information on blood pressure backflow caused by arterial obstructions in PAD patients. A vision transformer is finally integrated with the feature extraction layer to detect PAD, and stratify the severity level. This architecture is coined multi-stream-powered vision transformer (MSPViT). The performance of MSPViT is evaluated on 74 PAD and 21 healthy subjects. RESULTS: Sensitivity, specificity, F1 score, and area under the curve (AUC) of 99.45%, 98.21%, 99.37%, and 0.99, respectively, are reported for the binary classification which ensures accurate detection of PAD. Furthermore, MSPViT suggests average sensitivity, specificity, F1 score, and AUC of 96.66%, 97.34%, 96.29%, and 0.96, respectively, for the classification of subjects into healthy, mild-PAD, and severe-PAD classes. The silhouette score is calculated to assess the separability of clusters formed for classes in the penultimate layer of MSPViT. An average silhouette score of 0.66 and 0.81 demonstrate excellent cluster separability in PAD detection and severity classification, respectively. CONCLUSION: The achieved performance suggests that the proximal ACM-driven framework can replace state-of-the-art techniques for PAD detection. SIGNIFICANCE: This study presents a fundamental step towards prompt and accurate diagnosis of PAD and stratification of its severity level.


Assuntos
Doença Arterial Periférica , Humanos , Pressão Sanguínea , Acelerometria
4.
Cardiovasc Revasc Med ; 40S: 170-173, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34303624

RESUMO

Popliteal artery aneurysm (PAA) has been increasingly treated with endovascular intervention in recent years. However, whether transpedal access can be utilized to treat PAA has not been widely reported. We report a case of successful treatment of a PAA with a covered stent via retrograde transpedal approach in an 80-year male with prohibitive surgical risk who initially failed antegrade approach. This case demonstrates the feasibility of treating PAA via a retrograde transpedal access in selected patients.


Assuntos
Aneurisma , Procedimentos Endovasculares , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Humanos , Masculino , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/cirurgia , Estudos Retrospectivos , Stents , Resultado do Tratamento , Grau de Desobstrução Vascular
5.
Cardiovasc Revasc Med ; 36: 115-120, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34020900

RESUMO

BACKGROUND/PURPOSE: The transradial approach has been proposed as an alternative to traditional transfemoral access for diagnostic and therapeutic purposes in several catheterization procedures. Historically, extended length devices for lower limb endovascular interventions have been limited. The aim of this study was to investigate the acute clinical outcomes of orbital atherectomy (OA) via transradial access (TRA) for the treatment of lower extremity peripheral artery disease (PAD). METHODS/MATERIALS: REACH PVI was a multicenter, prospective, observational study (NCT03943160) including subjects with PAD and target lesion morphology appropriate for OA. All patients were followed post-procedure through the first standard of care follow-up visit. RESULTS: A total of 50 patients were enrolled. In most cases the indication for intervention was disabling claudication (74.0%). Overall, 50 target lesions were treated, 92.0% of lesions were femoropopliteal and 8.0% were infrapopliteal. The average lesion length was 98.3 ± 87.5 mm and 78.0% of the lesions were severely calcified. Balloon angioplasty was performed in 98.0% of target lesions, while a stent was deployed in 16.0%. Treatment success was 98.0%; in only one case the result was sub-optimal (>30% stenosis with stent placement) and a significant dissection was reported. No serious distal embolization, serious thrombus formation or serious acute vessel closure were observed intra- or post-procedurally. CONCLUSIONS: Transradial OA followed by percutaneous transluminal angioplasty for lower extremity PAD is feasible and demonstrates a favorable safety profile. Extended length devices such as the Extended Length Orbital Atherectomy System could further facilitate transradial endovascular procedures by increasing its spectrum of application.


Assuntos
Angioplastia Coronária com Balão , Doença Arterial Periférica , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Humanos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Estudos Prospectivos , Artéria Radial/diagnóstico por imagem , Artéria Radial/cirurgia , Resultado do Tratamento
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 7170-7173, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34892754

RESUMO

This study presents our recent findings on the classification of mean pressure gradient using angular chest movements in aortic stenosis (AS) patients. Currently, the severity of aortic stenosis is measured using ultra-sound echocardiography, which is an expensive technology. The proposed framework motivates the use of low-cost wearable sensors, and is based on feature extraction from gyroscopic readings. The feature space consists of the cardiac timing intervals as well as heart rate variability (HRV) parameters to determine the severity of disease. State-of-the-art machine learning (ML) methods are employed to classify the severity levels into mild, moderate, and severe. The best performance is achieved by the Light Gradient-Boosted Machine (Light GBM) with an F1-score of 94.29% and an accuracy of 94.44%. Additionally, game theory-based analyses are employed to examine the top features along with their average impacts on the severity level. It is demonstrated that the isovolumetric contraction time (IVCT) and isovolumetric relaxation time (IVRT) are the most representative features for AS severity.Clinical Relevance- The proposed framework could be an appropriate low-cost alternative to ultra-sound echocardiography, which is a costly method.


Assuntos
Estenose da Valva Aórtica , Algoritmos , Ecocardiografia , Frequência Cardíaca , Humanos , Respiração
7.
Sci Rep ; 11(1): 23817, 2021 12 10.
Artigo em Inglês | MEDLINE | ID: mdl-34893693

RESUMO

Recent research has shown promising results for the detection of aortic stenosis (AS) using cardio-mechanical signals. However, they are limited by two main factors: lacking physical explanations for decision-making on the existence of AS, and the need for auxiliary signals. The main goal of this paper is to address these shortcomings through a wearable inertial measurement unit (IMU), where the physical causes of AS are determined from IMU readings. To this end, we develop a framework based on seismo-cardiogram (SCG) and gyro-cardiogram (GCG) morphologies, where highly-optimized algorithms are designed to extract features deemed potentially relevant to AS. Extracted features are then analyzed through machine learning techniques for AS diagnosis. It is demonstrated that AS could be detected with 95.49-100.00% confidence. Based on the ablation study on the feature space, the GCG time-domain feature space holds higher consistency, i.e., 95.19-100.00%, with the presence of AS than HRV parameters with a low contribution of 66.00-80.00%. Furthermore, the robustness of the proposed method is evaluated by conducting analyses on the classification of the AS severity level. These analyses are resulted in a high confidence of 92.29%, demonstrating the reliability of the proposed framework. Additionally, game theory-based approaches are employed to rank the top features, among which GCG time-domain features are found to be highly consistent with both the occurrence and severity level of AS. The proposed framework contributes to reliable, low-cost wearable cardiac monitoring due to accurate performance and usage of solitary inertial sensors.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/fisiopatologia , Frequência Cardíaca , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Análise de Dados , Eletrocardiografia , Feminino , Humanos , Masculino , Modelos Teóricos
8.
Front Physiol ; 12: 750221, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34658932

RESUMO

This paper describes an open-access database for seismo-cardiogram (SCG) and gyro-cardiogram (GCG) signals. The archive comprises SCG and GCG recordings sourced from and processed at multiple sites worldwide, including Columbia University Medical Center and Stevens Institute of Technology in the United States, as well as Southeast University, Nanjing Medical University, and the first affiliated hospital of Nanjing Medical University in China. It includes electrocardiogram (ECG), SCG, and GCG recordings collected from 100 patients with various conditions of valvular heart diseases such as aortic and mitral stenosis. The recordings were collected from clinical environments with the same types of wearable sensor patch. Besides the raw recordings of ECG, SCG, and GCG signals, a set of hand-corrected fiducial point annotations is provided by manually checking the results of the annotated algorithm. The database also includes relevant echocardiogram parameters associated with each subject such as ejection fraction, valve area, and mean gradient pressure.

9.
Am J Cardiol ; 153: 94-100, 2021 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-34217433

RESUMO

We aimed to investigate the relationship of modified body mass index (mBMI), the product of BMI and serum albumin, with survival after transcatheter (TAVI) and surgical aortic valve implantation (SAVI). Frailty is associated with poor outcomes after TAVI and SAVI for severe aortic stenosis (AS). However, clinical frailty is not routinely measured in clinical practice due to the cumbersome nature of its assessment. Modified BMI is an easily measurable surrogate for clinical frailty that is associated with survival in elderly cohorts with non-valvular heart disease. We utilized individual patient-level data from a pooled database of the Placement of Aortic Transcatheter Valves (PARTNER) trials from the PARNTER1, PARTNER2 and S3 cohorts. We estimated cumulative mortality at 1 year for quartiles of mBMI with the Kaplan-Meier method and compared them with the log-rank test. We performed Cox proportional hazards modeling to assess the association of mBMI strata with 1-year mortality adjusting for baseline clinical characteristics. A total of 6593 patients who underwent TAVI or SAVI (mean age 83±7.3 years, 57% male) were included. mBMI was independently associated with all-cause one-year mortality with the lowest mBMI quartile as most predictive (HR 2.33, 95% CI 1.80-3.02, p < 0.0001). Notably, mBMI performed as well as clinical frailty index to predict 1-year mortality in this cohort. In conclusion, modified BMI predicts 1-year survival after both TAVI and SAVI. Given that it performed similar to the clinical frailty index, it may be used as a clinical tool for assessment of frailty prior to valve implantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Índice de Massa Corporal , Fragilidade/epidemiologia , Mortalidade , Albumina Sérica/metabolismo , Atividades Cotidianas , Injúria Renal Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial , Doenças Cardiovasculares/mortalidade , Causas de Morte , Feminino , Fragilidade/diagnóstico , Fragilidade/metabolismo , Força da Mão , Implante de Prótese de Valva Cardíaca , Hemorragia/epidemiologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Marca-Passo Artificial , Readmissão do Paciente , Complicações Pós-Operatórias/epidemiologia , Hemorragia Pós-Operatória/epidemiologia , Prognóstico , Modelos de Riscos Proporcionais , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter , Velocidade de Caminhada
10.
BMJ Open ; 11(4): e046054, 2021 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-33820792

RESUMO

OBJECTIVE: Our aim was to explore general practitioners' (GPs) perceptions and experiences of discontinuing antidepressants. STUDY DESIGN: A qualitative study using semistructured interviews was undertaken between July 2019 and March 2020. The interviews were transcribed and analysed using a thematic analysis framework. SETTING: GPs affiliated with a university education and research network for general practice in Ireland. PARTICIPANTS: A purposive sample of GPs (n=10). RESULTS: Five themes emerged: shared decision-making; personalised therapy; medication-tapering toolkit; health service factors and concerns around tapering. GPs described being less likely to engage in deprescribing for patients with long-term and/or recurrent depression, older patients and those with comorbidities due to fear of relapse. Access to evidence-based psychological therapies, guidelines, information on rates of relapse, patient leaflets on discontinuing antidepressants and reminder prompts on GP-prescribing software were suggested to optimise appropriate antidepressant discontinuation. There was some suggestion that patients may use antidepressants for longer when talk therapy is not available or taken up. CONCLUSIONS: GPs are largely confident in their role of managing mild-to-moderate depression and deprescribing antidepressants. This study provides an insight into factors that influence GPs' decisions to deprescribe antidepressants. More information on rates of relapse after discontinuation would be helpful to inform decision-making.


Assuntos
Desprescrições , Clínicos Gerais , Antidepressivos/uso terapêutico , Atitude do Pessoal de Saúde , Humanos , Irlanda , Pesquisa Qualitativa
11.
Vasc Med ; 26(4): 426-433, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33818200

RESUMO

Coronavirus disease 2019 (COVID-19) may predispose patients to venous thromboembolism (VTE). Limited data are available on the utilization of the Pulmonary Embolism Response Team (PERT) in the setting of the COVID-19 global pandemic. We performed a single-center study to evaluate treatment, mortality, and bleeding outcomes in patients who received PERT consultations in March and April 2020, compared to historical controls from the same period in 2019. Clinical data were abstracted from the electronic medical record. The primary study endpoints were inpatient mortality and GUSTO moderate-to-severe bleeding. The frequency of PERT utilization was nearly threefold higher during March and April 2020 (n = 74) compared to the same period in 2019 (n = 26). During the COVID-19 pandemic, there was significantly less PERT-guided invasive treatment (5.5% vs 23.1%, p = 0.02) with a numerical but not statistically significant trend toward an increase in the use of systemic fibrinolytic therapy (13.5% vs 3.9%, p = 0.3). There were nonsignificant trends toward higher in-hospital mortality or moderate-to-severe bleeding in patients receiving PERT consultations during the COVID-19 period compared to historical controls (mortality 14.9% vs 3.9%, p = 0.18 and moderate-to-severe bleeding 35.1% vs 19.2%, p = 0.13). In conclusion, PERT utilization was nearly threefold higher during the COVID-19 pandemic than during the historical control period. Among patients evaluated by PERT, in-hospital mortality or moderate-to-severe bleeding were not significantly different, despite being numerically higher, while invasive therapy was utilized less frequently during the COVID-19 pandemic.


Assuntos
COVID-19/terapia , Recursos em Saúde/tendências , Necessidades e Demandas de Serviços de Saúde/tendências , Equipe de Assistência ao Paciente/tendências , Padrões de Prática Médica/tendências , Embolia Pulmonar/terapia , Terapia Trombolítica/tendências , Tromboembolia Venosa/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/complicações , COVID-19/diagnóstico , COVID-19/mortalidade , Feminino , Hemorragia/etiologia , Hemorragia/mortalidade , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/etiologia , Embolia Pulmonar/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/etiologia , Tromboembolia Venosa/mortalidade
12.
CVIR Endovasc ; 4(1): 9, 2021 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-33409988

RESUMO

BACKGROUND: Transpedal access is increasingly utilized for the treatment of peripheral artery disease (PAD). Femoral-popliteal artery chronic total occlusions (CTOs) are some of the most difficult lesion subsets that sometimes require the use of re-entry support devices during percutaneous intervention. Limited data is available on the use of re-entry devices when treating femoral-popliteal CTOs via transpedal access. The aim of this study was to demonstrate the feasibility of using the Outback® Elite re-entry device for the treatment of femoral-popliteal CTOs via the transpedal approach in an outpatient based lab setting. METHODS: Seventeen patients presented with femoral-popliteal CTOs in which treatment required the use of the Outback® Elite re-entry device. All procedures were performed in a single outpatient based lab. Patients were followed at 1 week and 1 month post-procedure, with lower extremity arterial duplex ultrasound assessment during the 1 month follow-up. RESULTS: The average patient age was 78 years-old, with 71% being males. Most patients presented with Rutherford class IV symptoms. Procedural success was achieved in all patients with no requirement to convert to femoral artery access in any of the cases. No immediate post-procedural complications nor at any time during follow-up were observed. Ultrasonography at 1 month follow-up showed patent intervention sites and access site vessels in all patients. CONCLUSION: The use of the Outback® Elite re-entry device for the treatment of femoral-popliteal CTOs via transpedal access is a feasible option and may have potential benefits by avoiding risks associated with traditional femoral artery access.

13.
Catheter Cardiovasc Interv ; 97(1): E154-E160, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32521123

RESUMO

BACKGROUND: While slow gait speed is known to be associated with poor outcomes in patients at high surgical risk who undergo transcatheter aortic valve replacement (TAVR), the prognostic significance of slow gait speed in intermediate risk TAVR patients is poorly understood. OBJECTIVES: We assessed the association between baseline 6-min walk test (6MWT) performance and both 2-year mortality and health status in intermediate risk patients undergoing TAVR as a part of the PARTNER II/S3i studies. METHODS: The association of baseline 6MWT with mortality over 2-years after TAVR was examined using Cox regression; both unadjusted and adjusted for age, left ventricular ejection fraction, coronary artery disease, pulmonary disease, renal insufficiency, and STS score. Patients were divided into four groups according to baseline 6MWT: unable to walk and in three equal tertiles of slow, medium, and fast walkers. Among surviving patients, improvement in 6MWT and quality of life were compared. RESULTS: Among 2,037 intermediate risk TAVR patients (mean age 81.7 years, STS score 5.6%), 8.2% were unable to walk. Baseline 6MWT was associated with all-cause mortality over 2 years (Hazard ratio (HR) 0.87 per 50 m, 95% confidence interval [CI] 0.83 to 0.92, p < .0001). Among surviving patients, the adjusted absolute change in 6MWT at 2 years improved for patients unable to walk (+134.1 m, 95% CI 102.1 to 166 m, p < .0001) and slow walkers (+60.5 m, 95% CI 42.8 to 78.2 m, p < .0001), but was unchanged for medium walkers (-7.3 m, 95% CI -24.3 to 9.6 m, p = .4), and declined for fast walkers (-41.3 m, 95% CI -58.7 to -23.9 m, p < .0001). CONCLUSION: Poor functional capacity is predictive of 2-year mortality in elderly intermediate risk patients undergoing TAVR. However, surviving patients with poor baseline functional capacity had significant improvement in 6MWT performance and quality of life at 2-years following TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Prognóstico , Qualidade de Vida , Fatores de Risco , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Teste de Caminhada
14.
Circ Cardiovasc Interv ; 14(1): e009611, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33356383

RESUMO

BACKGROUND: The Bashir Endovascular Catheter (BEC) is a novel pharmaco-mechanical device designed to enhance thrombolysis by increasing the exposure of thrombus to endogenous and exogenous thrombolytics. The aim of this prospective, multicenter, single-arm study was to evaluate the feasibility and initial safety of the BEC in patients with acute intermediate-risk pulmonary embolism (PE). METHODS: Patients with symptomatic PE and right ventricular to left ventricular diameter ratio ≥0.9 as documented by computer tomography angiography were eligible for enrollment. The primary safety end points were device related death or adverse events, and major bleeding within 72 hours after BEC directed therapy. RESULTS: Nine patients were enrolled across 4 US sites. The total dose of r-tPA (recombinant tissue-type plasminogen activator) was 14 mgs in bilateral PE and 12 mgs in unilateral PE over 8 hours delivered via the expanded BEC. At 30-day follow-up, there were no deaths or device-related adverse events. At 48 hours post-BEC therapy, the right ventricular to left ventricular diameter ratio decreased from 1.52±0.26 to 0.97±0.06 (P=0.0009 [95% CI, 0.33-0.82]; 37.0% reduction). Thrombus burden as measured by the Modified Miller Index decreased from 25.4±5.3 to 16.0±4.0 (P=0.0005; [95% CI, 5.5-13.4]; 37.1% reduction). CONCLUSIONS: In this early feasibility study of the BEC for intermediate-risk PE, there were no deaths or device-related adverse events and a significant reduction in right ventricular to left ventricular diameter ratio and thrombus burden. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03927508.


Assuntos
Embolia Pulmonar , Catéteres , Estudos de Viabilidade , Fibrinolíticos/efeitos adversos , Humanos , Estudos Prospectivos , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/terapia , Fatores de Risco , Terapia Trombolítica/efeitos adversos , Resultado do Tratamento
15.
J Clin Child Adolesc Psychol ; 50(2): 215-228, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32058822

RESUMO

OBJECTIVE: The current study examined associations among organizational social context, after-school program (ASP) quality, and children's social behavior in a large urban park district. METHOD: Thirty-two park-based ASPs are included in the final sample, including 141 staff and 593 children. Staff reported on organizational culture (rigidity, proficiency, resistance) and climate (engagement, functionality, stress), and children's social skills and problem behaviors. Children and their parents reported on program quality indicators (e.g., activities, routines, relationships). Parents also completed a children's mental health screener. RESULTS: A series of Hierarchical Linear Models revealed that proficiency and stress were the only organizational predictors of program quality; associations between stress and program quality were moderated by program enrollment and aggregated children's mental health need. Higher child- and parent-perceived program quality related to fewer staff-reported problem behaviors, while overall higher enrollment and higher aggregated mental health need were associated with fewer staff-reported social skills. CONCLUSIONS: Data are informing ongoing efforts to improve organizational capacity of urban after-school programs to support children's positive social and behavior trajectories.


Assuntos
Saúde Mental , Instituições Acadêmicas , Comportamento Social , Meio Social , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Habilidades Sociais
16.
Am J Med ; 134(1): 95-103, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32805225

RESUMO

BACKGROUND: Oldest-old patients (≥85 years) constitute half the acute myocardial infarction hospitalizations among older adults and more commonly have atypical presentation, under-treatment, and functional impairments. Yet this group has not been well characterized. We characterized differences in presentation, functional impairments, treatments, health status, and mortality among middle-old (75-84 years) and oldest-old patients with myocardial infarction. METHODS: We analyzed data from the ComprehenSIVe Evaluation of Risk Factors in Older Patients with AMI (SILVER-AMI) study that enrolled 3041 patients ≥75 years of age from 94 hospitals across the US between 2013 and 2016. We performed Cox proportional hazards regression to examine the association between the oldest-old (n = 831) and middle-old (n = 2210) age categories with postdischarge 6-month case fatality rate adjusting for sociodemographic and clinical variables, and mobility impairment. RESULTS: The oldest-old were less likely to present with chest pain (52.7% vs 57.7%) as their primary symptom or to receive coronary revascularization (58.1% vs 71.8) (P < .01 for both). The oldest-old were more likely to have functional impairments and had higher 6-month mortality compared with the middle-old patients (hazard ratio 1.78, 95% confidence interval, 1.39-2.28). This association was substantially attenuated after adjusting for mobility impairment (hazard ratio 1.29, confidence interval, 0.99-1.68). CONCLUSIONS: There is considerable heterogeneity in presentation, treatment, and outcomes among older patients with myocardial infarction. Mobility impairment, a marker for frailty, modifies the association between advanced age and treatments as well as outcomes.


Assuntos
Fatores Etários , Infarto do Miocárdio/complicações , Resultado do Tratamento , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Feminino , Geriatria/métodos , Humanos , Masculino , Infarto do Miocárdio/epidemiologia , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Modelos de Riscos Proporcionais
17.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 2820-2823, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-33018593

RESUMO

This paper reports our study on the impact of transcatheter aortic valve replacement (TAVR) on the classification of aortic stenosis (AS) patients using cardio-mechanical modalities. Machine learning algorithms such as decision tree, random forest, and neural network were applied to conduct two tasks. Firstly, the pre- and post-TAVR data are evaluated with the classifiers trained in the literature. Secondly, new classifiers are trained to classify between pre- and post-TAVR data. Using analysis of variance, the features that are significantly different between pre- and post-TAVR patients are selected and compared to the features used in the pre-trained classifiers. The results suggest that pre-TAVR subjects could be classified as AS patients but post-TAVR could not be classified as healthy subjects. The features which differentiate pre- and post-TAVR patients reveal different distributions compared to the features that classify AS patients and healthy subjects. These results could guide future work in the classification of AS as well as the evaluation of the recovery status of patients after TAVR treatment.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Aprendizado de Máquina , Resultado do Tratamento
18.
Sci Rep ; 10(1): 17521, 2020 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-33067495

RESUMO

This paper introduces a study on the classification of aortic stenosis (AS) based on cardio-mechanical signals collected using non-invasive wearable inertial sensors. Measurements were taken from 21 AS patients and 13 non-AS subjects. A feature analysis framework utilizing Elastic Net was implemented to reduce the features generated by continuous wavelet transform (CWT). Performance comparisons were conducted among several machine learning (ML) algorithms, including decision tree, random forest, multi-layer perceptron neural network, and extreme gradient boosting. In addition, a two-dimensional convolutional neural network (2D-CNN) was developed using the CWT coefficients as images. The 2D-CNN was made with a custom-built architecture and a CNN based on Mobile Net via transfer learning. After the reduction of features by 95.47%, the results obtained report 0.87 on accuracy by decision tree, 0.96 by random forest, 0.91 by simple neural network, and 0.95 by XGBoost. Via the 2D-CNN framework, the transfer learning of Mobile Net shows an accuracy of 0.91, while the custom-constructed classifier reveals an accuracy of 0.89. Our results validate the effectiveness of the feature selection and classification framework. They also show a promising potential for the implementation of deep learning tools on the classification of AS.


Assuntos
Estenose da Valva Aórtica/classificação , Estenose da Valva Aórtica/fisiopatologia , Aprendizado Profundo , Aprendizado de Máquina , Processamento de Sinais Assistido por Computador , Idoso , Algoritmos , Estenose da Valva Aórtica/diagnóstico , Engenharia Biomédica , Árvores de Decisões , Elasticidade , Feminino , Análise de Elementos Finitos , Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Redes Neurais de Computação , Projetos Piloto , Reprodutibilidade dos Testes , Análise de Ondaletas
19.
JACC Case Rep ; 2(9): 1391-1396, 2020 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-32835284

RESUMO

Severe acute respiratory syndrome coronavirus 2 is associated with a prothrombotic state in infected patients. After presenting a case of right ventricular thrombus in a patient with coronavirus disease-2019 (COVID-19), we discuss the unique challenges in the evaluation and treatment of COVID-19 patients, highlighting our COVID-19-modified pulmonary embolism response team algorithm. (Level of Difficulty: Beginner.).

20.
SAGE Open Med Case Rep ; 8: 2050313X20929194, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32547765

RESUMO

Growing endovascular strategies with TASC D lesions in aortoiliac disease reflect increasing technical success with evidenced safety and efficacy. In cases of failed transfemoral access, revascularization of iliac chronic total occlusions has prompted the utilization of other alternate access sites (e.g. transradial and transbrachial approaches) as important options in aortoiliac TASC D lesions. We describe a case of successful revascularization of an occluded ostial left common iliac artery in an 81-year-old man using a dual ulnar and tibioperoneal approach (absent radial artery). A Controlled Antegrade and Retrograde Tracking technique was performed where a balloon was advanced from the peroneal artery into the distal cap of the chronic total occlusion in the proximal common femoral artery. Balloon inflation was performed and a glidewire from transulnar access was advanced and re-entered into the true lumen in the common femoral artery. The wire was then snared and externalized out the transpedal access site creating a continuous true lumen from the ulnar artery to the peroneal artery. To reconstruct the aortic bifurcation, kissing balloon inflations were performed from the peroneal as well as the ulnar artery approaches. A 10 mm × 59 mm balloon expandable stent was placed in the ostial left common iliac artery and a 8 mm × 60 mm self-expanding stent was placed in the left external iliac artery successfully.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...