1.
Med Phys ; 41(4): 041710, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24694130

RESUMO

PURPOSE: To provide specific experience-based guidance and recommendations for centers wishing to develop, validate, and implement an accurate and efficient process for directly using positron emission tomography-computed tomography (PET-CT) for the radiotherapy planning of head and neck cancer patients. METHODS: A PET-CT system was modified with hard-top couch, external lasers and radiotherapy immobilization and indexing devices and was subject to a commissioning and quality assurance program. PET-CT imaging protocols were developed specifically for radiotherapy planning and the image quality and pathway tested using phantoms and five patients recruited into an in-house study. Security and accuracy of data transfer was tested throughout the whole data pathway. The patient pathway was fully established and tested ready for implementation in a PET-guided dose-escalation trial for head and neck cancer patients. RESULTS: Couch deflection was greater than for departmental CT simulator machines. An area of high attenuation in the couch generated image artifacts and adjustments were made accordingly. Using newly developed protocols CT image quality was suitable to maintain delineation and treatment accuracy. Upon transfer of data to the treatment planning system a half pixel offset between PET and CT was observed and corrected. By taking this into account, PET to CT alignment accuracy was maintained below 1 mm in all systems in the data pathway. Transfer of structures delineated in the PET fusion software to the radiotherapy treatment planning system was validated. CONCLUSIONS: A method to perform direct PET-guided radiotherapy planning was successfully validated and specific recommendations were developed to assist other centers. Of major concern is ensuring that the quality of PET and CT data is appropriate for radiotherapy treatment planning and on-treatment verification. Couch movements can be compromised, bore-size can be a limitation for certain immobilization techniques, laser positioning may affect setup accuracy and couch deflection may be greater than scanners dedicated to radiotherapy. The full set of departmental commissioning and routine quality assurance tests applied to radiotherapy CT simulators must be carried out on the PET-CT scanner. CT image quality must be optimized for radiotherapy planning whilst understanding that the appearance will differ between scanners and may affect delineation. PET-CT quality assurance schedules will need to be added to and modified to incorporate radiotherapy quality assurance. Methods of working for radiotherapy and PET staff will change to take into account considerations of both parties. PET to CT alignment must be subject to quality control on a loaded and unloaded couch preferably using a suitable emission phantom, and tested throughout the whole data pathway. Data integrity must be tested throughout the whole pathway and a system included to verify that delineated structures are transferred correctly. Excellent multidisciplinary team communication and working is vital, and key staff members on both sides should be specifically dedicated to the project. Patient pathway should be clearly devised to optimize patient care and the resources of all departments. Recruitment of a cohort of patients into a methodology study is valuable to test the quality assurance methods and pathway.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico , Neoplasias de Cabeça e Pescoço/radioterapia , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada por Raios X , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem/instrumentação
2.
Phys Med Biol ; 50(12): 2739-48, 2005 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-15930599

RESUMO

This addendum to the code of practice for the determination of absorbed dose for x-rays below 300 kV has recently been approved by the IPEM and introduces three main changes: (i) Due to a lack of available data the original code recommended a value of unity for k(ch) in the very-low-energy range (0.035-1.0 mm Al HVL). A single table of k(ch) values, ranging from 1.01 to 1.07, applicable to both designated chamber types is now presented. (ii) For medium-energy x-rays (0.5-4 mm Cu HVL) methods are given to determine the absorbed dose to water either at 2 cm depth or at the surface of a phantom depending on clinical needs. Determination of the dose at the phantom surface is derived from an in-air measurement and by extending the low-energy range up to 4 mm Cu HVL. Relevant backscatter factors and ratios of mass energy absorption coefficients are given in the addendum. (iii) Relative dosimetry: although not normally forming part of a dosimetry code of practice a brief review of the current literature on this topic has been added as an appendix. This encompasses advice on techniques for measuring depth doses, applicator factors for small field sizes, dose fall off with increasing SSD and choice of appropriate phantom materials and ionization chambers.


Assuntos
Dosagem Radioterapêutica , Radioterapia/métodos , Humanos , Imagens de Fantasmas , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Espalhamento de Radiação , Raios X
3.
J Stone Dis ; 4(3): 216-9, 1992 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10147668

RESUMO

Extracorporeal shock wave lithotripsy (ESWL) uses either X-ray fluoroscopy or ultrasound to localize and determine the end point of treatment. We report radiation doses to patients and personnel from the Storz Modulith lithotripter system recently installed in the Lithotripter Centre, St. Thomas' Hospital, London. The mean annual radiation dose to patients and staff was calculated at 0.73 mSv and 4.8 mSv, respectively.


Assuntos
Litotripsia/efeitos adversos , Litotripsia/instrumentação , Humanos , Exposição Ocupacional , Doses de Radiação , Raios X