Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
JRSM Cardiovasc Dis ; 11: 20480040221087556, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35342625

RESUMO

A high temporal resolution, 4-chamber (4CH) cine is the standard method for determining cardiac rest periods during whole heart coronary magnetic resonance angiography (CMRA). We evaluated the image quality and reproducibility between the 4CH cine method and a novel approach using a velocity encoded mitral valve inflow cine (MVI). The goal of this study was to compare the quality of CMRAs utilizing MVI versus 4CH methods. Sharpness and vessel length for the LCA and RCA using each method were determined using Soap Bubble and two blinded observers independently assessed coronary image quality. Offline analysis on a separate, retrospective cohort (n = 25) was used to compare MVI and 4CH reproducibility. In the prospectively evaluated cohort there was no difference in overall vessel sharpness (4CH vs MVI mean ± SD) (31.0 ± 5.5% vs 30.5 ± 5.7%, p = .63), LCA vessel sharpness (30.0 ± 5.4% vs 31.1 ± 8.2%, p = .44), LCA length (4.7 ± 1.4 cm vs 4.6 ± 1.6 cm, p = .66), RCA vessel sharpness (32.1 ± 6.9% vs 31.1 ± 7.7%, p = .55), RCA length (5.51 ± 2.6 cm vs 5.95 ± 2.4 cm, p = .38), or image quality rating (2.66 vs 2.62, p = .80) between methods. In the retrospective cohort, the MVI method had 5.4% lower inter-observer variability (95% CI 3.7,7.2%, p < .0001) and 3.9% lower intra-observer variability (95% CI 2.4,5.4%, p < .0001) than the 4CH method. MVI is a technically feasible and more reproducible method to determine cardiac rest periods compared to 4CH while preserving vessel sharpness, vessel length & image quality.

2.
J Cardiovasc Magn Reson ; 23(1): 16, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33641664

RESUMO

BACKGROUND: Due to passive blood flow in palliated single ventricle, central venous pressure increases chronically, ultimately impeding lymphatic drainage. Early visualization and treatment of these malformations is essential to reduce morbidity and mortality. Cardiovascular magnetic resonance (CMR) T2-weighted lymphangiography (T2w) is used for lymphatic assessment, but its low signal-to-noise ratio may result in incomplete visualization of thoracic duct pathway. 3D-balanced steady state free precession (3D-bSSFP) is commonly used to assess congenital cardiac disease anatomy. Here, we aimed to improve diagnostic imaging of thoracic duct pathway using 3D-bSSFP. METHODS: Patients underwent CMR during single ventricle or central lymphatic system assessment using T2w and 3D-bSSFP. T2w parameters included 3D-turbo spin echo (TSE), TE/TR = 600/2500 ms, resolution = 1 × 1 × 1.8 mm, respiratory triggering with bellows. 3D-bSSFP parameters included electrocardiogram triggering and diaphragm navigator, 1.6 mm isotropic resolution, TE/TR = 1.8/3.6 ms. Thoracic duct was identified independently in T2w and 3D-bSSFP images, tracked completely from cisterna chyli to its drainage site, and classified based on severity of lymphatic abnormalities. RESULTS: Forty-eight patients underwent CMR, 46 of whom were included in the study. Forty-five had congenital heart disease with single ventricle physiology. Median age at CMR was 4.3 year (range 0.9-35.1 year, IQR 2.4 year), and median weight was 14.4 kg (range, 7.9-112.9 kg, IQR 5.2 kg). Single ventricle with right dominant ventricle was noted in 31 patients. Thirty-eight patients (84%) were status post bidirectional Glenn and 7 (16%) were status post Fontan anastomosis. Thoracic duct visualization was achieved in 45 patients by T2w and 3D-bSSFP. Complete tracking to drainage site was attained in 11 patients (24%) by T2w vs 25 (54%) by 3D-bSSFP and in 28 (61%) by both. Classification of lymphatics was performed in 31 patients. CONCLUSION: Thoracic duct pathway can be visualized by 3D-bSSFP combined with T2w lymphangiography. Cardiac triggering and respiratory navigation likely help retain lymphatic signal in the retrocardiac area by 3D-bSSFP. Visualizing lymphatic system leaks is challenging on 3D-bSSFP images alone, but 3D-bSSFP offers good visualization of duct anatomy and landmark structures to help plan interventions. Together, these sequences can define abnormal lymphatic pathway following single ventricle palliative surgery, thus guiding lymphatic interventional procedures.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Imageamento Tridimensional , Linfografia , Imageamento por Ressonância Magnética , Ducto Torácico/diagnóstico por imagem , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Lactente , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ducto Torácico/fisiopatologia , Adulto Jovem
3.
Pediatr Cardiol ; 42(3): 578-589, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33394116

RESUMO

Ventricular contouring of cardiac magnetic resonance imaging is the gold standard for volumetric analysis for repaired tetralogy of Fallot (rTOF), but can be time-consuming and subject to variability. A convolutional neural network (CNN) ventricular contouring algorithm was developed to generate contours for mostly structural normal hearts. We aimed to improve this algorithm for use in rTOF and propose a more comprehensive method of evaluating algorithm performance. We evaluated the performance of a ventricular contouring CNN, that was trained on mostly structurally normal hearts, on rTOF patients. We then created an updated CNN by adding rTOF training cases and evaluated the new algorithm's performance generating contours for both the left and right ventricles (LV and RV) on new testing data. Algorithm performance was evaluated with spatial metrics (Dice Similarity Coefficient (DSC), Hausdorff distance, and average Hausdorff distance) and volumetric comparisons (e.g., differences in RV volumes). The original Mostly Structurally Normal (MSN) algorithm was better at contouring the LV than the RV in patients with rTOF. After retraining the algorithm, the new MSN + rTOF algorithm showed improvements for LV epicardial and RV endocardial contours on testing data to which it was naïve (N = 30; e.g., DSC 0.883 vs. 0.905 for LV epicardium at end diastole, p < 0.0001) and improvements in RV end-diastolic volumetrics (median %error 8.1 vs 11.4, p = 0.0022). Even with a small number of cases, CNN-based contouring for rTOF can be improved. This work should be extended to other forms of congenital heart disease with more extreme structural abnormalities. Aspects of this work have already been implemented in clinical practice, representing rapid clinical translation. The combined use of both spatial and volumetric comparisons yielded insights into algorithm errors.


Assuntos
Algoritmos , Ventrículos do Coração/diagnóstico por imagem , Redes Neurais de Computação , Tetralogia de Fallot/diagnóstico por imagem , Adulto , Estudos de Casos e Controles , Feminino , Ventrículos do Coração/anatomia & histologia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino
6.
J Cardiovasc Magn Reson ; 20(1): 76, 2018 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-30474554

RESUMO

BACKGROUND: Volumetric black-blood cardiovascular magnetic resonance (CMR) has been hampered by long scan times and flow sensitivity. The purpose of this study was to assess the feasibility of black-blood, electrocardiogram (ECG)-triggered and respiratory-navigated 3D fast spin echo (3D FSE) for the visualization of the whole heart and great vessels. METHODS: The implemented 3D FSE technique used slice-selective excitation and non-selective refocusing pulses with variable flip angles to achieve constant echo signal for tissue with T1 (880 ms) and T2 (40 ms) similar to the vessel wall. Ten healthy subjects and 21 patients with congenital heart disease (CHD) underwent 3D FSE and conventional 3D balanced steady-state free precession (bSSFP). The sequences were compared in terms of ability to perform segmental assessment, local signal-to-noise ratio (SNRl) and local contrast-to-noise ratio (CNRl). RESULTS: In both healthy subjects and patients with CHD, 3D FSE showed superior pulmonary vein but inferior coronary artery origin visualisation compared to 3D bSFFP. However, in patients with CHD the combination of 3D bSSFP and 3D FSE whole-heart imaging improves the success rate of cardiac morphological diagnosis to 100% compared to either technique in isolation (3D FSE, 23.8% success rate, 3D bSSFP, 5% success rate). In the healthy subjects SNRl for 3D bSSFP was greater than for 3D FSE (30.1 ± 7.3 vs 20.9 ± 5.3; P = 0.002) whereas the CNRl was comparable (17.3 ± 5.6 vs 17.4 ± 4.9; P = 0.91) between the two scans. CONCLUSIONS: The feasibility of 3D FSE for whole-heart black-blood CMR imaging has been demonstrated. Due to their high success rate for segmental assessment, the combination of 3D bSSFP and 3D FSE may be an attractive alternative to gadolinium contrast enhanced morphological CMR in patients with CHD.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Cardiopatias Congênitas/diagnóstico por imagem , Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Eletrocardiografia , Estudos de Viabilidade , Feminino , Coração/fisiopatologia , Cardiopatias Congênitas/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Circulação Pulmonar , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Adulto Jovem
7.
BMC Med Imaging ; 18(1): 36, 2018 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-30326847

RESUMO

BACKGROUND: Dual-phase 3-dimensional whole-heart acquisition allows simultaneous imaging during systole and diastole. Respiratory navigator gating and tracking of the diaphragm is used with limited accuracy. Prolonged scan time is common, and navigation often fails in patients with erratic breathing. Image-navigation (iNAV) tracks movement of the heart itself and is feasible in single phase whole heart imaging. To evaluate its diagnostic ability in congenital heart disease, we sought to apply iNAV to dual-phase sequencing. METHODS: Healthy volunteers and patients with congenital heart disease underwent dual-phase imaging using the conventional diaphragmatic-navigation (dNAV) and iNAV. Acquisition time was recorded and image quality assessed. Sharpness and length of the right coronary (RCA), left anterior descending (LAD), and circumflex (LCx) arteries were measured in both cardiac phases for both approaches. Qualitative and quantitative analyses were performed in a blinded and randomized fashion. RESULTS: In volunteers, there was no significant difference in vessel sharpness between approaches (p > 0.05). In patients, analysis showed equal vessel sharpness for LAD and RCA (p > 0.05). LCx sharpness was greater with dNAV (p < 0.05). Visualized length with iNAV was 0.5 ± 0.4 cm greater than that with dNAV for LCx in diastole (p < 0.05), 1.0 ± 0.3 cm greater than dNAV for LAD in diastole (p < 0.05), and 0.8 ± 0.7 cm greater than dNAV for RCA in systole (p < 0.05). Qualitative scores were similar between modalities (p = 0.71). Mean iNAV scan time was 5:18 ± 2:12 min shorter than mean dNAV scan time in volunteers (p = 0.0001) and 3:16 ± 1:12 min shorter in patients (p = 0.0001). CONCLUSIONS: Image quality of iNAV and dNAV was similar with better distal vessel visualization with iNAV. iNAV acquisition time was significantly shorter. Complete cardiac diagnosis was achieved. Shortened acquisition time will improve clinical applicability and patient comfort.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Distribuição Aleatória
8.
Magn Reson Imaging ; 49: 47-54, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29339139

RESUMO

BACKGROUND: CMRA in pediatrics remains challenging due to the smaller vessel size, high heart rates (HR), potential image degradation caused by limited patient cooperation and long acquisition times. High-relaxivity contrast agents have been shown to improve coronary imaging in adults, but limited data is available in children. We sought to investigate whether gadobenate dimeglumine (Gd-BOPTA) together with self-navigated inversion-prepared coronary magnetic resonance angiography (CMRA) sequence design improves coronary image quality in pediatric patients. METHODS: Forty consecutive patients (mean age 6±2.8years; 73% males) were prospectively recruited for a 1.5-T MRI study under general anesthesia. Two electrocardiographic-triggered free breathing steady-state free precession (SSFP) angiography sequences (A and B) with isotropic spatial resolution (1.3mm3) were acquired using a recently developed image-based self-navigation technique. Sequence A was acquired prior to contrast administration using T2 magnetization preparation (T2prep). Sequence B was acquired 5-8min after a bolus of Gd-BOPTA with the T2prep replaced by an inversion recovery (IR) pulse to null the signal from the myocardium. Scan time, signal-to noise and contrast-to-noise ratios (SNR and CNR), vessel wall sharpness (VWS) and qualitative visual score for each sequence were compared. RESULTS: Scan time was similar for both sequences (5.3±1.8 vs 5.2±1.5min, p=.532) and average heart rate (78±14.7 vs 78±14.5bpm, p=.443) remained constant throughout both acquisitions. Sequence B resulted in higher SNR (12.6±4.4 vs 31.1±7.4, p<.001) and CNR (9.0±1.8 vs 13.5±3.7, p<.001) and provided improved coronary visualization in all coronary territories (VWS A=0.53±0.07 vs B=0.56±0.07, p=.001; and visual scoring A=3.8±0.59 vs B=4.1±0.53, p<.001). The number of non-diagnostic coronary segments was lower for sequence B [A=42 (13.1%) segments vs B=33 (10.3%) segments; p=.002], and contrary to the pre-contrast sequence, never involved a proximal segment. These results were independent of the patients' age, body surface area and HR. CONCLUSIONS: The use of Gd-BOPTA with a 3D IR SSFP CMRA sequence results in improved coronary visualization in small infants and young children with high HR within a clinically acceptable scan time.


Assuntos
Meios de Contraste , Vasos Coronários/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Criança , Pré-Escolar , Vasos Coronários/patologia , Feminino , Cardiopatias Congênitas/patologia , Humanos , Masculino , Estudos Prospectivos , Razão Sinal-Ruído
9.
J Appl Physiol (1985) ; 125(3): 889-900, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29369740

RESUMO

Ventricular volumetric ejection fraction (VV EF) is often normal in patients with single ventricle circulations despite them experiencing symptoms related to circulatory failure. We sought to determine if kinetic energy (KE) could be a better marker of ventricular performance. KE was prospectively quantified using four-dimensional flow MRI in 41 patients with a single ventricle circulation (aged 0.5-28 yr) and compared with 43 healthy volunteers (aged 1.5-62 yr) and 14 patients with left ventricular (LV) dysfunction (aged 28-79 yr). Intraventricular end-diastolic blood was tracked through systole and divided into ejected and residual blood components. Two ejection fraction (EF) metrics were devised based on the KE of the ejected component over the total of both the ejected and residual components using 1) instantaneous peak KE to assess KE EF or 2) summating individual peak particle energy (PE) to assess PE EF. KE EF and PE EF had a smaller range than VV EF in healthy subjects (97.9 ± 0.8 vs. 97.3 ± 0.8 vs. 60.1 ± 5.2%). LV dysfunction caused a fall in KE EF ( P = 0.01) and PE EF ( P = 0.0001). VV EF in healthy LVs and single ventricle hearts was equivalent; however, KE EF and PE EF were lower ( P < 0.001) with a wider range indicating a spectrum of severity. Those reporting the greatest symptomatic impairment (New York Heart Association II) had lower PE EF than asymptomatic subjects ( P = 0.0067). KE metrics are markers of healthy cardiac function. PE EF may be useful in grading dysfunction. NEW & NOTEWORTHY Kinetic energy (KE) represents the useful work of the heart in ejecting blood. This article details the utilization of KE indexes to assess cardiac function in health and a variety of pathophysiological conditions. KE ejection fraction and particle energy ejection fraction (PE EF) showed a narrow range in health and a lower wider range in disease representing a spectrum of severity. PE EF was altered by functional status potentially offering the opportunity to grade dysfunction.


Assuntos
Metabolismo Energético/fisiologia , Ventrículos do Coração/anatomia & histologia , Adolescente , Adulto , Idoso , Envelhecimento/fisiologia , Algoritmos , Biomarcadores , Circulação Sanguínea/fisiologia , Criança , Pré-Escolar , Feminino , Voluntários Saudáveis , Cardiopatias Congênitas/fisiopatologia , Humanos , Lactente , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Volume Sistólico , Função Ventricular Esquerda , Adulto Jovem
10.
PLoS One ; 12(11): e0188292, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29190694

RESUMO

PURPOSE: X-ray coronary angiography (XCA) is the current gold standard for the assessment of lumen encroaching coronary stenosis but XCA does not allow for early detection of rupture-prone vulnerable plaques, which are thought to be the precursor lesions of most acute myocardial infarctions (AMI) and sudden death. The aim of this study was to investigate the potential of delayed contrast-enhanced magnetic resonance coronary vessel wall imaging (CE-MRCVI) for the detection of culprit lesions in the coronary arteries. METHODS: 16 patients (13 male, age 61.9±8.6 years) presenting with sub-acute MI underwent CE-MRCVI within 24-72h prior to invasive XCA. CE-MRCVI was performed using a T1-weighted 3D gradient echo inversion recovery sequence (3D IR TFE) 40±4 minutes following the administration of 0.2 mmol/kg gadolinium-diethylenetriamine-pentaacetic acid (DTPA) on a 3T MRI scanner equipped with a 32-channel cardiac coil. RESULTS: 14 patients were found to have culprit lesions (7x LAD, 1xLCX, 6xRCA) as identified by XCA. Quantitative CE-MRCVI correctly identified the culprit lesion location with a sensitivity of 79% and excluded culprit lesion formation with a specificity of 99%. The contrast to noise ratio (CNR) of culprit lesions (9.7±4.1) significantly exceeded CNR values of segments without culprit lesions (2.9±1.9, p<0.001). CONCLUSION: CE-MRCVI allows the selective visualization of culprit lesions in patients immediately after myocardial infarction (MI). The pronounced contrast uptake in ruptured plaques may represent a surrogate biomarker of plaque activity and/or vulnerability.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
12.
Artigo em Inglês | MEDLINE | ID: mdl-28144782

RESUMO

OPINION STATEMENT: Cardiac magnetic resonance imaging (CMR) is an important imaging modality in the evaluation of congenital heart diseases (CHD). CMR has several strengths including good spatial and temporal resolutions, wide field-of-view, and multi-planar imaging capabilities. CMR provides significant advantages for imaging in CHD through its ability to measure function, flow and vessel sizes, create three-dimensional reconstructions, and perform tissue characterization, all in a single imaging study. Thus, CMR is the most comprehensive imaging modality available today for the evaluation of CHD. Newer MRI sequences and post-processing tools will allow further development of quantitative methods of analysis, and opens the door for risk stratification in CHD. CMR also can interface with computer modeling, 3D printing, and other methods of understanding the complex anatomic and physiologic relationships in CHD.

13.
Int J Cardiol ; 230: 439-446, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28043677

RESUMO

BACKGROUND: Children with a single systemic right ventricle, such as in hypoplastic left heart syndrome (HLHS), frequently experience reduced exercise capacity. Elucidating the causes could help with optimising treatment strategies. METHODS: Prospective data from 10 consecutive symptomatic patients with HLHS undergoing clinical cardiac magnetic resonance with catheterisation (XMR) were analysed. Mean age 8.6years (range 3.5-11.6years), mean time since Fontan completion 5.5years. MR-compatible catheters were placed in the systemic right ventricle and branch pulmonary arteries to record pressures at rest, with dobutamine infusion at 10mcg/kg/min and at 20mcg/kg/min. Cine short-axis stacks of the ventricle were performed at each condition and used to construct pressure-volume loops. RESULTS: Compared to rest, cardiac index increased with low-dose dobutamine (p<0.01) with no further rise at peak stress despite a further, albeit, blunted rise in heart rate (p=0.002). A fall in stroke volume occurred (p=0.014) despite good contractility (74% increase, p=0.045) and a well-coupled ventriculo-arterial ratio. End-diastolic pressure and early active relaxation, markers of diastolic function, were normal at rest. However, preload fell at peak stress (p<0.008) while pulmonary vascular resistance (PVR) was low throughout. This group of HLHS patients demonstrated a fall in SV at peak stress, coinciding with a fall in preload. CONCLUSIONS: Markers of systolic and diastolic function remained normal. Failure to adequately fill the ventricle implies a ceiling of maximal flow through the Fontan circuit despite low PVR.


Assuntos
Débito Cardíaco/fisiologia , Tolerância ao Exercício/fisiologia , Síndrome do Coração Esquerdo Hipoplásico/fisiopatologia , Pressão Sanguínea/fisiologia , Cateterismo Cardíaco , Criança , Pré-Escolar , Dobutamina , Teste de Esforço , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Resistência Vascular/fisiologia
14.
Eur J Cardiothorac Surg ; 51(1): 50-57, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27422888

RESUMO

OBJECTIVES: The Norwood procedure for hypoplastic left heart syndrome (HLHS) is performed either via a right ventricle-to-pulmonary artery (RVPA) conduit or a modified Blalock-Taussig (MBT) shunt. Cardiac magnetic resonance (CMR) data was used to assess the effects of the RVPA conduit on ventricular shape and function through a computational analysis of anatomy and assessment of indices of strain. METHODS: A retrospective analysis of 93 CMR scans of subjects with HLHS was performed (59 with MBT shunt, 34 with RVPA conduit), incorporating data at varying stages of surgery from two congenital centres. Longitudinal and short-axis cine images were used to create a computational cardiac atlas and assess global strain. RESULTS: Those receiving an RVPA conduit had significant differences (P< 0.0001) in the shape of the RV corresponding to increased ventricular dilatation (P = 0.001) and increased sphericity (P = 0.006). Differences were evident only following completion of stage II surgery. Despite preserved ejection fraction in both groups, functional strain in the RVPA conduit group compared with that in the MBT shunt group was reduced across multiple ventricular axes, including a reduced systolic longitudinal strain rate (P< 0.0001), reduced diastolic longitudinal strain rate (P = 0.0001) and reduced midventricular systolic circumferential strain (P < 0.0001). CONCLUSIONS: Computational modelling analysis reveals differences in ventricular remodelling in patients with HLHS undergoing an RVPA conduit insertion with focal scarring and volume loading leading to decreased functional markers of strain. The need for continued surveillance is warranted, as deleterious effects may not become apparent until later years.


Assuntos
Procedimento de Blalock-Taussig/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Artéria Pulmonar/cirurgia , Função Ventricular Direita/fisiologia , Remodelação Ventricular/fisiologia , Anastomose Cirúrgica/métodos , Feminino , Humanos , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico , Síndrome do Coração Esquerdo Hipoplásico/fisiopatologia , Recém-Nascido , Imagem Cinética por Ressonância Magnética , Masculino , Procedimentos de Norwood/métodos , Estudos Retrospectivos , Resultado do Tratamento
15.
Eur Radiol ; 27(11): 4612-4618, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-27743116

RESUMO

OBJECTIVES: The aim of this study was to investigate the impact of BMI on late gadolinium enhancement (LGE) of the coronary artery wall in identical monozygous twins discordant for BMI. Coronary LGE represents a useful parameter for the detection and quantification of atherosclerotic coronary vessel wall disease. METHODS: Thirteen monozygote female twin pairs (n = 26) with significantly different BMIs (>1.6 kg/m2) were recruited out of >10,000 twin pairs (TwinsUK Registry). A coronary 3D-T2prep-TFE MR angiogram and 3D-IR-TFE vessel wall scan were performed prior to and following the administration of 0.2 mmol/kg of Gd-DTPA on a 1.5 T MR scanner. The number of enhancing coronary segments and contrast to noise ratios (CNRs) of the coronary wall were quantified. RESULTS: An increase in BMI was associated with an increased number of enhancing coronary segments (5.3 ± 1.5 vs. 3.5 ± 1.6, p < 0.0001) and increased coronary wall enhancement (6.1 ± 1.1 vs. 4.8 ± 0.9, p = 0.0027) compared to matched twins with lower BMI. CONCLUSIONS: This study in monozygous twins indicates that acquired factors predisposing to obesity, including lifestyle and environmental factors, result in increased LGE of the coronary arteries, potentially reflecting an increase in coronary atherosclerosis in this female study population. KEY POINTS: • BMI-discordant twins allow the investigation of the influence of lifestyle factors independent from genetic confounders. • Only thirteen obesity-discordant twins were identified underlining the strong genetic component of BMI. • In female twins, a BMI increase is associated with increased coronary late gadolinium enhancement. • Increased late gadolinium enhancement in the coronary vessel wall potentially reflects increased atherosclerosis.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/patologia , Doenças em Gêmeos , Gadolínio DTPA/farmacologia , Imageamento por Ressonância Magnética/métodos , Obesidade/complicações , Gêmeos Monozigóticos , Adulto , Idoso , Índice de Massa Corporal , Meios de Contraste/farmacologia , Doença da Artéria Coronariana/etiologia , Feminino , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade , Obesidade/diagnóstico , Curva ROC
16.
J Cardiovasc Magn Reson ; 18(1): 66, 2016 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-27716273

RESUMO

BACKGROUND: The use of gadolinium contrast agents in cardiovascular magnetic resonance is well-established and serves to improve both vascular imaging as well as enable late gadolinium enhancement (LGE) imaging for tissue characterization. Currently, gadofosveset trisodium, an intravascular contrast agent, combined with a three-dimensional inversion recovery balanced steady state free precession (3D IR bSSFP) sequence, is commonly used in pediatric cardiac imaging and yields excellent vascular imaging, but cannot be used for late gadolinium enhancement. Gadofosveset use remains limited in clinical practice, and manufacture was recently halted, thus an alternative is needed to allow 3D IR bSSFP and LGE in the same study. METHODS: Here we propose a protocol to give a bolus of 0.1 mL/kg = 0.1 mmol/kg gadobutrol (GADAVIST/GADOVIST) for time-resolved magnetic resonance angiography (MRA). Subsequently, 0.1 mmol/kg is diluted up to 5 or 7.5 mL with saline and then loaded into intravenous tubing connected to the patient. A 0.5 mL short bolus is infused, then a slow infusion is given at 0.02 or 0.03 mL/s. Image navigated (iNAV) 3D IR bSSFP imaging is initiated 45-60 s after the initiation of the infusion, with a total image acquisition time of ~5 min. If necessary, LGE imaging using phase sensitive inversion recovery reconstruction (PSIR) is performed at 10 min after the infusion is initiated. RESULTS: We have successfully performed the above protocol with good image quality on 10 patients with both time-resolved MRA and 3D IR bSSFP iNAV imaging. Our initial attempts to use pencil beam respiratory navigation failed due to signal labeling in the liver by the navigator. We have also performed 2D PSIR LGE successfully, with both LGE positive and LGE negative results. CONCLUSION: A bolus of gadobutrol, followed later by a slow infusion, allows time-resolved MRA, 3D IR bSSFP using the iNAV navigation technique, and LGE imaging, all in a single study with a single contrast agent.


Assuntos
Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Coração/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Compostos Organometálicos/administração & dosagem , Coração/fisiopatologia , Cardiopatias Congênitas/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Infusões Intravenosas , Injeções Intravenosas , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Tempo
17.
Int J Cardiovasc Imaging ; 32(8): 1273-9, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27173489

RESUMO

Three-dimensional printing has an increasing number of clinical applications in pediatric cardiology. Time required for dataset segmentation and conversion to stereolithography (STL) format remains a significant limitation. We investigated the impact of semi-automated cardiovascular-specific segmentation software on time and reproducibility of segmentation. Magnetic resonance angiograms (MRAs) of 19 patients undergoing intervention for right ventricular outflow lesions were segmented to demonstrate the right heart. STLs were created by two independent clinicians using semi-automated cardiovascular segmentation (SAS) and traditional manual segmentation (MS). Time was recorded and geometric STL disagreement was determined (0 % = no disagreement, 100 % = complete disagreement). MRA datasets were categorized as clean when only right heart structures were present in the MRA, or contaminated when left heart structures were also present and required removal. Eighteen (seven clean and 11 contaminated) cases were successfully segmented with both methods. Time to STL for clean datasets was faster with MS than SAS [median 209 s (IQR 192-252) vs. 296 s (272-317), p = 0.018] while contaminated datasets were faster with SAS [455 s (384-561) vs. 866 s (310-1429), p = 0.033]. Interobserver STL geometric disagreement was significantly lower using SAS than MS overall (0.70 ± 1.15 % vs. 1.31 ± 1.52 %, p = 0.030), and for the contaminated subset (0.81 ± 1.08 % vs. 1.75 ± 1.57 %, p = 0.036). Most geometric disagreement occurred at areas where left heart contamination was removed. Semi-automated segmentation was faster and more reproducible for contaminated datasets, while MS was faster but equally reproducible for clean datasets. Semi-automated segmentation methods are preferable for contaminated datasets and continued refinement of these tools should be supported.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Impressão Tridimensional , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Adolescente , Automação , Cateterismo Cardíaco , Criança , Pré-Escolar , Meios de Contraste/administração & dosagem , Feminino , Cardiopatias Congênitas/complicações , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Adulto Jovem
18.
World J Clin Pediatr ; 5(1): 1-15, 2016 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-26862497

RESUMO

Cardiovascular magnetic resonance is a non-invasive imaging modality which is emerging as important tool for the investigation and management of pediatric cardiovascular disease. In this review we describe the key technical and practical differences between scanning children and adults, and highlight some important considerations that must be taken into account for this patient population. Using case examples commonly seen in clinical practice, we discuss the important clinical applications of cardiovascular magnetic resonance, and briefly highlight key future developments in this field.

19.
J Magn Reson Imaging ; 43(4): 947-55, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26451972

RESUMO

BACKGROUND: The purpose of this study was to evaluate a recently developed two-dimensional (2D) image-based navigation approach (iNAVG+C ) combined with respiratory bellows gating for CMRA in patients with congenital heart disease. METHODS: Nine healthy volunteers (mean age 32 ± 6 years [standard deviation]) and 29 patients (28 ± 9 years) were scanned on a 1.5 Tesla clinical scanner using iNAV(G+C) motion compensated T2prepared CMRA, and the conventional 1D NAV approach. Scan time was recorded for each CMRA scan. An image quality score was given to each coronary artery from (0, uninterpretable; to 4, excellent image quality). Additionally, vessel sharpness of each coronary artery was measured. RESULTS: Average scan time was significantly shorter (P < 0.01) using the proposed iNAVC+G approach (7:57 ± 1:34) compared with 1D NAV (9:15 ± 3:02). Improved visual scores of the right coronary artery (iNAV(G+C) : 4,3,4 (median, 25th percentile, 75th percentile) versus 1D NAV: 3,3,4; P < 0.001) and left anterior descending artery (iNAV(G+C) : 3,3,4 versus 1D NAV: 3,2,3; P < 0.001) were obtained using iNAV(G+C) compared with 1D NAV as well as an increased vessel sharpness of the right coronary artery (iNAV(G+C) : 65.3% ± 6.6% (mean ± standard deviation) versus 1D NAV: 60.2% ± 11.4%; P < 0.05) and left anterior descending artery (iNAV(G+C) : 63.2% ± 6.7% versus 1D NAV: 58.3% ± 9.5%; P < 0.05). CONCLUSION: Image-based navigation in combination with respiratory bellows gating allows for more robust suppression of respiratory motion artifacts for whole-heart CMRA compared with conventional 1D NAV as images can be acquired in a shorter time and with improved image quality.


Assuntos
Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Cardiopatias Congênitas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Algoritmos , Feminino , Voluntários Saudáveis , Cardiopatias Congênitas/patologia , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Movimento (Física) , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Respiração , Técnicas de Imagem de Sincronização Respiratória/métodos
20.
BMC Med Imaging ; 15: 48, 2015 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-26502883

RESUMO

BACKGROUND: The purpose of this study was to see how coronary magnetic resonance angiography (CMRA) compared to echocardiography for the detection of coronary artery origins and to compare CMRA measurements for coronary dimensions in children with published echocardiographic reference values. METHODS: Enrolled patients underwent dual cardiac phase CMRA and echocardiography under the same anesthetic. Echocardiographic measurements of the right coronary artery (RCA), left anterior descending (LAD) and left main (LM) were made. CMRA dimensions were assessed manually at the same points as the echocardiographic measurements. The number of proximal LAD branches imaged was also recorded in order to give an estimate of distal coronary tree visualization. RESULTS: Fifty patients (24 boys, mean age 4.0 years (range 18 days to 18 years)) underwent dual-phase CMRA. Coronary origins were identified in 47/50 cases for CMRA (remaining 3 were infants aged 3, 9 and 11 months). In comparison, origins were identified in 41/50 cases for echo (remaining were all older children). CMRA performed better than echocardiography in terms of distal visualization of the coronary tree (median 1 LAD branch vs. median 0; p = 0.001). Bland-Altman plots show poor agreement between echocardiography and CMRA for coronary measurements. CMRA measurements did vary according to cardiac phase (systolic mean 1.90, s.d. 0.05 mm vs. diastolic mean 1.84, s.d. 0.05 mm; p = 0.002). CONCLUSIONS: Dual-phase CMRA has an excellent (94 %) success rate for the detection of coronary origins in children. Newborn infants remain challenging and echocardiography remains the accepted imaging modality for this age group. Echocardiographic reference ranges are not applicable to CMRA measurements as agreement was poor between modalities. Future coronary reference values, using any imaging modality, should quote the phase in which it was measured.


Assuntos
Angiografia Coronária/métodos , Vasos Coronários/anatomia & histologia , Ecocardiografia/métodos , Angiografia por Ressonância Magnética/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Tamanho do Órgão , Estudos Prospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...