Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 89(10): 10E116, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399980

RESUMO

Wendelstein 7-X aims at quasi-steady state operation with up to 10 MW of heating power for 30 min. Power exhaust will be handled predominantly via 10 actively water cooled CFC (carbon-fiber-reinforced carbon) based divertor units designed to withstand power loads of 10 MW/m2 locally in steady state. If local loads exceed this value, a risk of local delamination of the CFC and failure of entire divertor modules arises. Infrared endoscopes to monitor all main plasma facing components are being prepared, and near real time software tools are under development to identify areas of excessive temperature rise, to distinguish them from non-critical events, and to trigger alarms. Tests with different cameras were made in the recent campaign. Long pulse operation enforces additional diagnostic design constraints: for example, the optics need to be thermally decoupled from the endoscope housing. In the upcoming experimental campaign, a graphite scraper element, in front of the island divertor throat, will be tested as a possible means to protect the divertor pumping gap edges during the transient discharge evolution.

2.
Langmuir ; 23(4): 2091-4, 2007 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-17243731

RESUMO

Superhydrophobicity and superhydrophilicity of surfaces are key properties for fabrication of self-cleaning surfaces (Lotus effect). It is well known that the mechanism behind this is based on the surface roughness and surface functionalization. To obtain an understanding of the details of the underlying mechanism, a metal system based on a eutectic is suggested. In this study, a wide range tunability of its needlelike narrow size distributed nanostructure is demonstrated. The length of the needles as well as their density can be varied independently. In addition, an important parameter for the wettability, the roughness, is related directly to the growth parameters, which lead to excellent controllable and reproducible eutectic structures. Simply by varying etching time very high aspect ratios can be achieved, allowing studying the interaction of the very long needles with liquids. Moreover, the surface functionality can be tuned by RF-magnetron sputtering of PTFE onto the metal needles. As those layers can be very thin, our system allows, in principle, studying the transition from a metal to a polymer surface using submonolayers. Furthermore, the first contact angle measurements on the nanostructured and functionalized eutectic structures are presented and discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...