Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acad Emerg Med ; 18(8): 816-21, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21843216

RESUMO

OBJECTIVES: Automated bladder ultrasound (ABUS) devices are portable and designed to provide automated measurement of bladder volume. They are simple and require minimal training compared to conventional real-time ultrasound (RTUS). Their most common application in the acute pediatric setting is to assess bladder volumes prior to performing invasive urine collection such as suprapubic aspiration (SPA) in children younger than 2 years of age. However, data on ABUS in young children are limited. The aim of this study was to assess the repeatability and accuracy of one type of ABUS, the BladderScan, in measuring of bladder volume in children aged 0 to 24 months when compared with RTUS. METHODS: Healthy children aged 24 months and younger were scanned twice, 1 hour apart, using ABUS and RTUS. ABUS readings were performed by two senior pediatric emergency physicians who both completed three readings for each child. The measurements were repeated using a second ABUS machine in case of machine variability. RTUS measurements were performed by a pediatric sonographer who was blinded to the ABUS results. ABUS and RTUS measurements were compared by Bland-Altman analysis to determine the repeatability coefficient (repeatability) and the limits of clinical agreement (accuracy). RESULTS: Bladder volume measurements were performed on 61 children aged 0 to 24 months (31 males; mean ± SD = age 11 ± 6.2 months; range = 0 to 24 months) using both the ABUS and the RTUS. There was wide variation between ABUS and RTUS measurements. The repeatability coefficient within ABUS readings was 20 mL. By Bland-Altman analysis, the 95% limits of agreement between ABUS and RTUS were -31 to +19 mL. ABUS also detected no values between 0 and 10 mL. CONCLUSIONS: This study showed poor repeatability and accuracy in bladder volume measurements using BladderScan ABUS when compared to RTUS. The ABUS method does not appear to be a reliable method for assessing bladder volumes in children aged 0 to 24 months prior to bladder instrumentation.


Assuntos
Ultrassonografia/métodos , Bexiga Urinária/diagnóstico por imagem , Retenção Urinária/diagnóstico por imagem , Automação , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia/normas , Vitória
2.
Reprod Biol ; 8(3): 229-43, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19092985

RESUMO

Ultrasound was used to measure growth of the spiny mouse fetus throughout gestation and to record Doppler measurements of heart rate and umbilical blood flow to monitor fetal blood supply and wellbeing. Female spiny mice were anesthetized on 6 occasions throughout pregnancy. Ultrasound was performed with a Philips HDI 5000 machine using a compact linear CL15-7 transducer. Fetal heart rate and growth parameters increased across gestation. Blood flow through the umbilical artery and vein showed increasing velocity over gestation, and reduced resistance index. Blood flow through the ductus venosus also increased in velocity over gestation; however the resistance index remained constant. We have determined changes in umbilical blood flow throughout pregnancy in the spiny mouse, which resemble those seen in human pregnancy. We also confirm that ultrasound can be used as a valuable, non-invasive technique for measuring fetal growth and wellbeing in the spiny mouse.


Assuntos
Desenvolvimento Fetal , Murinae/embriologia , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Sangue Fetal/fisiologia , Feto/irrigação sanguínea , Frequência Cardíaca Fetal , Gravidez , Ultrassonografia Pré-Natal , Artérias Umbilicais/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...