1.
J Mass Spectrom ; 59(4): e5006, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38501497

RESUMO

Space charge effects are the Achilles' heel of all high-resolution ion optical devices. In time-of-flight mass analyzers, these may manifest as reduction of resolving power, mass measurement shift, peak coalescence, and/or transmission losses, while highly sensitive modern ion sources and injection devices ensure that such limits are easily exceeded. Space charge effects have been investigated, by experiment and simulation study, for the astral multi-reflection analyzer, incorporating ion focusing via a pair of converging ion mirrors, and fed by a pulsed extraction ion trap. Major factors were identified as the resonant effect between ~103 ions of similar m/z in-flight and the expansion of trapped packets of ~104-5 ions prior to extraction. Optimum operation and compensated ion mirror calibration strategies were then generated and described based on these findings.

2.
J Am Soc Mass Spectrom ; 35(4): 658-662, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38286823

RESUMO

The quality of data in charge detection mass spectrometry depends on accurate determination of ion charge. While the method of selective temporal overview of resonant ions (STORI) has proven to be highly enabling for determining the charge of ions that survive for variable amounts of time, it assumes that the ion frequency exactly matches the frequency being used in the calculation. Any mismatches result in low charge estimates. To address this, the misSTORI method was developed to correct these discrepancies. This can significantly reduce the charge measurement errors for samples with unstable masses. As an example, the misSTORI approach can eliminate a 5.7% charge determination error for a VP3-only AAV capsid that shifts 25 ppm in mass.

3.
Mol Cell Proteomics ; 23(2): 100713, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38184013

RESUMO

Optimizing data-independent acquisition methods for proteomics applications often requires balancing spectral resolution and acquisition speed. Here, we describe a real-time full mass range implementation of the phase-constrained spectrum deconvolution method (ΦSDM) for Orbitrap mass spectrometry that increases mass resolving power without increasing scan time. Comparing its performance to the standard enhanced Fourier transformation signal processing revealed that the increased resolving power of ΦSDM is beneficial in areas of high peptide density and comes with a greater ability to resolve low-abundance signals. In a standard 2 h analysis of a 200 ng HeLa digest, this resulted in an increase of 16% in the number of quantified peptides. As the acquisition speed becomes even more important when using fast chromatographic gradients, we further applied ΦSDM methods to a range of shorter gradient lengths (21, 12, and 5 min). While ΦSDM improved identification rates and spectral quality in all tested gradients, it proved particularly advantageous for the 5 min gradient. Here, the number of identified protein groups and peptides increased by >15% in comparison to enhanced Fourier transformation processing. In conclusion, ΦSDM is an alternative signal processing algorithm for processing Orbitrap data that can improve spectral quality and benefit quantitative accuracy in typical proteomics experiments, especially when using short gradients.


Assuntos
Proteoma , Espectrometria de Massas em Tandem , Humanos , Proteoma/metabolismo , Espectrometria de Massas em Tandem/métodos , Peptídeos/análise , Células HeLa , Proteômica/métodos
4.
J Am Soc Mass Spectrom ; 35(1): 74-81, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-37925680

RESUMO

Ion traps are routinely directly coupled to mass analyzers, where they serve to suitably cool and shape an ion population prior to pulsed extraction into the analyzer proper. Such devices benefit from high duty cycle and transmission but suffer slow ion processing times caused by a compromise in the buffer gas pressure range that suitably dampens the ion kinetic energy without causing excessive scatter during extraction or within the analyzer. A rectilinear RF quadrupole ion trap has been characterized, conjoining a pressurized collision region with a pumped extraction region, and an unbroken RF interface for seamless ion transfer between them. Auxiliary electrodes mounted between the RF electrodes provide DC voltage gradients that serve to both guide ions through the device and position them at the extraction slot. The influence of the auxiliary DC upon the trapping RF field was measured, and suitable parameters were defined. A mode of operation was developed that allowed parallel processing of ions in both regions, enabling a repetition rate of 200 Hz when the device was coupled to a high-resolution accurate-mass analyzer.

5.
Anal Chem ; 95(42): 15656-15664, 2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37815927

RESUMO

The growing trend toward high-throughput proteomics demands rapid liquid chromatography-mass spectrometry (LC-MS) cycles that limit the available time to gather the large numbers of MS/MS fragmentation spectra required for identification. Orbitrap analyzers scale performance with acquisition time and necessarily sacrifice sensitivity and resolving power to deliver higher acquisition rates. We developed a new mass spectrometer that combines a mass-resolving quadrupole, the Orbitrap, and the novel Asymmetric Track Lossless (Astral) analyzer. The new hybrid instrument enables faster acquisition of high-resolution accurate mass (HRAM) MS/MS spectra compared with state-of-the-art mass spectrometers. Accordingly, new proteomics methods were developed that leverage the strengths of each HRAM analyzer, whereby the Orbitrap analyzer performs full scans with a high dynamic range and resolution, synchronized with the Astral analyzer's acquisition of fast and sensitive HRAM MS/MS scans. Substantial improvements are demonstrated over previous methods using current state-of-the-art mass spectrometers.

6.
Anal Chem ; 95(19): 7656-7664, 2023 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-37133913

RESUMO

The measurement of collision cross sections (CCS, σ) offers supplemental information about sizes and conformations of ions beyond mass analysis alone. We have previously shown that CCSs can be determined directly from the time-domain transient decay of ions in an Orbitrap mass analyzer as ions oscillate around the central electrode and collide with neutral gas, thus removing them from the ion packet. Herein, we develop the modified hard collision model, thus deviating from the prior FT-MS hard sphere model, to determine CCSs as a function of center-of-mass collision energy in the Orbitrap analyzer. With this model, we aim to increase the upper mass limit of CCS measurement for native-like proteins, characterized by low charge states and presumed to be in more compact conformations. We also combine CCS measurements with collision induced unfolding and tandem mass spectrometry experiments to monitor protein unfolding and disassembly of protein complexes and measure CCSs of ejected monomers from protein complexes.


Assuntos
Proteínas , Proteínas/química , Íons/química
7.
Commun Chem ; 6(1): 64, 2023 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-37024568

RESUMO

Mass spectrometry (MS)-based thermal stability assays have recently emerged as one of the most promising solutions for the identification of protein-ligand interactions. Here, we have investigated eight combinations of several recently introduced MS-based advancements, including the Phase-Constrained Spectral Deconvolution Method, Field Asymmetric Ion Mobility Spectrometry, and the implementation of a carrier sample as improved MS-based acquisition approaches for thermal stability assays (iMAATSA). We used intact Jurkat cells treated with a commercially available MEK inhibitor, followed by heat treatment, to prepare a set of unfractionated isobarically-labeled proof-of-concept samples to compare the performance of eight different iMAATSAs. Finally, the best-performing iMAATSA was compared to a conventional approach and evaluated in a fractionation experiment. Improvements of up to 82% and 86% were demonstrated in protein identifications and high-quality melting curves, respectively, over the conventional approach in the proof-of-concept study, while an approximately 12% improvement in melting curve comparisons was achieved in the fractionation experiment.

8.
Anal Chem ; 94(45): 15613-15620, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-36326832

RESUMO

Measurement of collision cross section (CCS), a parameter reflecting an ion's size and shape, alongside high-resolution mass analysis extends the depth of molecular analysis by providing structural information beyond molecular mass alone. Although these measurements are most commonly undertaken using a dedicated ion mobility cell coupled to a mass spectrometer, alternative methods have emerged to extract CCSs directly by analysis of the decay rates of either time-domain transient signals or the FWHM of frequency domain peaks in FT mass analyzers. This information is also accessible from FTMS mass spectra obtained in commonly used workflows directly without the explicit access to transient or complex Fourier spectra. Previously, these experiments required isolation of individual charge states of ions prior to CCS analysis, limiting throughput. Here we advance Orbitrap CCS measurements to more users and applications by determining CCSs from commonly available mass spectra files as well as estimating CCS for multiple charge states simultaneously and showcase these methods by the measurement of CCSs of fragment ions produced from collisional activation of proteins.


Assuntos
Proteínas , Espectrometria de Massas/métodos , Íons/química
9.
J Proteome Res ; 17(11): 4008-4016, 2018 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-30220210

RESUMO

A popular method for peptide quantification relies on isobaric labeling such as tandem mass tags (TMT), which enables multiplexed proteome analyses. Quantification is achieved by reporter ions generated by fragmentation in a tandem mass spectrometer. However, with higher degrees of multiplexing, the smaller mass differences between the reporter ions increase the mass resolving power requirements. This contrasts with faster peptide sequencing capabilities enabled by lowered mass resolution on Orbitrap instruments. It is therefore important to determine the mass resolution limits for highly multiplexed quantification when maximizing proteome depth. Here, we defined the lower boundaries for resolving TMT reporter ions with 0.0063 Da mass differences using an ultra-high-field Orbitrap mass spectrometer. We found the optimal method depends on the relative ratio between closely spaced reporter ions and that 64 ms transient acquisition time provided sufficient resolving power for separating TMT reporter ions with absolute ratio changes up to 16-fold. Furthermore, a 32 ms transient processed with phase-constrained spectrum deconvolution provides >50% more identifications with >99% quantified but with a slight loss in quantification precision and accuracy. These findings should guide decisions on what Orbitrap resolution settings to use in future proteomics experiments, relying on isobaric TMT reporter ion quantification.


Assuntos
Peptídeos/análise , Proteoma/isolamento & purificação , Proteômica/métodos , Coloração e Rotulagem/métodos , Espectrometria de Massas em Tandem/métodos , Linhagem Celular , Linhagem Celular Tumoral , Células Epiteliais/química , Células Epiteliais/citologia , Células HeLa , Humanos , Íons , Células Jurkat , Neurônios/química , Neurônios/patologia , Osteoblastos/química , Osteoblastos/patologia , Proteólise , Proteoma/genética , Proteoma/metabolismo , Epitélio Pigmentado da Retina/química , Epitélio Pigmentado da Retina/citologia
10.
Anal Chem ; 90(9): 5896-5902, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29608288

RESUMO

We demonstrate a method for determining the collision cross-sections (CCSs) of protein ions based on the decay rate of the time-domain transient signal from an Orbitrap mass analyzer. Multiply charged ions of ubiquitin, cytochrome c, and myoglobin were generated by electrospray ionization of both denaturing solutions and ones with high salt content to preserve native-like structures. A linear relationship between the pressure in the Orbitrap analyzer and the transient decay rate was established and used to demonstrate that the signal decay is primarily due to ion-neutral collisions for protein ions across the entire working pressure range of the instrument. The CCSs measured in this study were compared with previously published CCS values measured by ion mobility mass spectrometry (IMS), and results from the two methods were found to differ by less than 7% for all charge states known to adopt single gas-phase conformations.


Assuntos
Citocromos c/análise , Mioglobina/análise , Ubiquitina/análise , Animais , Bovinos , Cavalos , Espectrometria de Mobilidade Iônica , Íons , Espectrometria de Massas por Ionização por Electrospray
11.
Nat Methods ; 14(12): 1175-1183, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29131162

RESUMO

We report the development of a 3D OrbiSIMS instrument for label-free biomedical imaging. It combines the high spatial resolution of secondary ion mass spectrometry (SIMS; under 200 nm for inorganic species and under 2 µm for biomolecules) with the high mass-resolving power of an Orbitrap (>240,000 at m/z 200). This allows exogenous and endogenous metabolites to be visualized in 3D with subcellular resolution. We imaged the distribution of neurotransmitters-gamma-aminobutyric acid, dopamine and serotonin-with high spectroscopic confidence in the mouse hippocampus. We also putatively annotated and mapped the subcellular localization of 29 sulfoglycosphingolipids and 45 glycerophospholipids, and we confirmed lipid identities with tandem mass spectrometry. We demonstrated single-cell metabolomic profiling using rat alveolar macrophage cells incubated with different concentrations of the drug amiodarone, and we observed that the upregulation of phospholipid species and cholesterol is correlated with the accumulation of amiodarone.


Assuntos
Dopamina/análise , Hipocampo/metabolismo , Imagem Molecular/métodos , Serotonina/análise , Frações Subcelulares/metabolismo , Ácido gama-Aminobutírico/análise , Amiodarona/metabolismo , Animais , Células Cultivadas , Desenho de Equipamento , Feminino , Glicerofosfolipídeos/análise , Imageamento Tridimensional , Macrófagos Alveolares/metabolismo , Metabolômica/instrumentação , Metabolômica/métodos , Camundongos , Imagem Molecular/instrumentação , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Sulfoglicoesfingolipídeos/análise , Espectrometria de Massas em Tandem
12.
Anal Chem ; 89(2): 1202-1211, 2017 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-27982570

RESUMO

This Article introduces a new computationally efficient noise-tolerant signal processing method, referred to as phased spectrum deconvolution method (ΦSDM), designed for Fourier transform mass spectrometry (FT MS). ΦSDM produces interference-free mass spectra with resolution beyond the Fourier transform (FT) uncertainty limit. With a presumption that the oscillation phases are preserved, the method deconvolves an observed FT spectrum into a distribution of harmonic components bound to a fixed frequency grid, which is several times finer than that of FT. The approach shows stability under noisy conditions, and the noise levels in the resulting spectra are lower than those of the original FT spectra. Although requiring more computational power than standard FT algorithms, ΦSDM runs in a quasilinear time. The method was tested on both synthetic and experimental data, and consistently demonstrated performance superior to the FT-based methodologies, be it across the entire mass range or on a selected mass window of interest. ΦSDM promises substantial improvements in the spectral quality and the speed of FT MS instruments. It might also be beneficial for other spectroscopy approaches which require harmonic analysis for data processing.

13.
Eur J Mass Spectrom (Chichester) ; 20(2): 131-42, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24895773

RESUMO

The multireflection ion traps with isochronous properties offer a Lot of opportunities for time-of-flight mass spectrometry by elongation of the ion path, thus preserving the compact dimensions of an instrument. We have built and tested a two-mirror linear trap that provides at least 80,000 mass-resolving power. Although the mass resolution appears promising, there are substantial limitations that arise from Coulomb interactions of the trapped ions. Among these, the mutual repulsion of ions with same or close mass-to-charge ratios appears dominant, resulting in counterintuitive motion synchronization. The self-bunching and coalescence effects are also examined by numerical simulation.

14.
J Am Chem Soc ; 136(20): 7295-9, 2014 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-24787140

RESUMO

Accurate mass analysis can provide useful information on the stoichiometry and composition of protein-based particles, such as virus-like assemblies. For applications in nanotechnology and medicine, such nanoparticles are loaded with foreign cargos, making accurate mass information essential to define the cargo load. Here, we describe modifications to an Orbitrap mass spectrometer that enable high mass analysis of several virus-like nanoparticles up to 4.5 MDa in mass. This allows the accurate determination of the composition of virus-like particles. The modified instrument is utilized to determine the cargo load of bacterial encapsulin nanoparticles that were engineered to encapsulate foreign cargo proteins. We find that encapsulin packages from 8 up to 12 cargo proteins, thereby quantifying cargo load but also showing the ensemble spread. In addition, we determined the previously unknown stoichiometry of the three different splice variants of the capsid protein in adeno-associated virus (AAV) capsids, showing that symmetry is broken and assembly is heterogeneous and stochastic. These results demonstrate the potential of high-resolution mass analysis of protein-based nanoparticles, with widespread applications in chemical biology and nanotechnology.


Assuntos
Bactérias/química , Proteínas de Bactérias/química , Capsídeo/química , Dependovirus/química , Nanopartículas/química , Espectrometria de Massas