Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Int Conf Rehabil Robot ; 2023: 1-6, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37941194

RESUMO

The use of vibrotactile feedback is of growing interest in the field of prosthetics, but few devices fully integrate this technology in the prosthesis to transmit high-frequency contact information (such as surface roughness and first contact) arising from the interaction of the prosthetic device with external items. This study describes a wearable vibrotactile system for high-frequency tactile information embedded in the prosthetic socket. The device consists of two compact planar vibrotactile actuators in direct contact with the user's skin to transmit tactile cues. These stimuli are directly related to the acceleration profiles recorded with two IMUS placed on the distal phalanx of a soft under-actuated robotic prosthesis (Soft-Hand Pro). We characterized the system from a psychophysical point of view with fifteen able-bodied participants by computing participants' Just Noticeable Difference (JND) related to the discrimination of vibrotactile cues delivered on the index finger, which are associated with the exploration of different sandpapers. Moreover, we performed a pilot experiment with one SoftHand Pro prosthesis user by designing a task, i.e. Active Texture Identification, to investigate if our feedback could enhance users' roughness discrimination. Results indicate that the device can effectively convey contact and texture cues, which users can readily detect and distinguish.


Assuntos
Membros Artificiais , Biônica , Humanos , Desenho de Prótese , Retroalimentação Sensorial , Tato
2.
IEEE Int Conf Rehabil Robot ; 2023: 1-6, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37941211

RESUMO

One of the most frequent and severe aftermaths of a stroke is the loss of upper limb functionality. Therapy started in the sub-acute phase proved more effective, mainly when the patient participates actively. Recently, a novel set of rehabilitation and support robotic devices, known as supernumerary robotic limbs, have been introduced. This work investigates how a surface electromyography (sEMG) based control strategy would improve their usability in rehabilitation, limited so far by input interfaces requiring to subjects some level of residual mobility. After briefly introducing the phenomena hindering post-stroke sEMG and its use to control robotic hands, we describe a framework to acquire and interpret muscle signals of the forearm extensors. We applied it to drive a supernumerary robotic limb, the SoftHand-X, to provide Task-Specific Training (TST) in patients with sub-acute stroke. We propose and describe two algorithms to control the opening and closing of the robotic hand, with different levels of user agency and therapist control. We experimentally tested the feasibility of the proposed approach on four patients, followed by a therapist, to check their ability to operate the hand. The promising preliminary results indicate sEMG-based control as a viable solution to extend TST to sub-acute post-stroke patients.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Mãos/fisiologia , Extremidade Superior , Robótica/métodos , Reabilitação do Acidente Vascular Cerebral/métodos , Eletromiografia/métodos
3.
IEEE Int Conf Rehabil Robot ; 2023: 1-6, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37941253

RESUMO

Small obstacles on the ground often lead to a fall when caught with commercial prosthetic feet. Despite some recently developed feet can actively control the ankle angle, for instance over slopes, their flat and rigid sole remains a cause of instability on uneven grounds. Soft robotic feet were recently proposed to tackle that issue; however, they lack consistent experimental validation. Therefore, this paper describes the experimental setup realized to test soft and rigid prosthetic feet with lower-limb prosthetic users. It includes a wooden walkway and differently shaped obstacles. It was preliminary validated with an able-bodied subject, the same subject walking on commercial prostheses through modified walking boots, and with a prosthetic user. They performed walking firstly on even ground, and secondly on even ground stepping on one of the obstacles. Results in terms of vertical ground reaction force and knee moments in both the sagittal and frontal planes show how the poor performance of commonly used prostheses is exacerbated in case of obstacles. The prosthetic user, indeed, noticeably relies on the sound leg to compensate for the stiff and unstable interaction of the prosthetic limb with the obstacle. Therefore, since the limitations of non-adaptive prosthetic feet in obstacle-dealing emerge from the experiments, as expected, this study justifies the use of the setup for investigating the performance of soft feet on uneven grounds and obstacle negotiation.


Assuntos
Amputados , Membros Artificiais , Humanos , Marcha , Fenômenos Biomecânicos , , Caminhada , Desenho de Prótese
4.
IEEE Trans Haptics ; 16(4): 760-769, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37801383

RESUMO

Despite technological advancements, upper limb prostheses still face high abandonment/rejection rates due to limitations in control interfaces and the absence of force/tactile feedback. Improving these aspects is crucial for enhancing user acceptance and optimizing functional performance. This pilot study, therefore, aims to understand which sensory feedback in combination with a soft robotic prosthetic hand could provide advantages for amputees, including performing everyday tasks. Tactile cues provided are contact information, grasping force, degree of hand opening, and combinations of this information. To transfer such feedback, different wearable systems are used, based on either vibrotactile or force stimulation in a non-invasive modality matching approach. Five volunteers with a trans-radial amputation controlling the new prosthetic hand SoftHand Pro performed a study protocol including everyday tasks. The results indicate the preference of amputees for a single, i.e. non-combined, feedback modality. The choice of appropriate haptic feedback seems to be subject and task-specific. Furthermore, in alignment with the participants' feedback, force feedback, with adequate granularity and clarity, could potentially be the most valuable feedback among those presented. Finally, the study suggests that prosthetic solutions should be preferred where amputees are able to choose their feedback system.


Assuntos
Amputados , Membros Artificiais , Percepção do Tato , Humanos , Projetos Piloto , Retroalimentação , Tecnologia Háptica , Percepção do Tato/fisiologia , Extremidade Superior , Retroalimentação Sensorial/fisiologia
5.
PLoS One ; 18(8): e0289978, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37585427

RESUMO

Although recent technological developments in the field of bionic upper limb prostheses, their rejection rate remains excessively high. The reasons are diverse (e.g. lack of functionality, control complexity, and comfortability) and most of these are reported only through self-rated questionnaires. Indeed, there is no quantitative evaluation of the extent to which a novel prosthetic solution can effectively address users' needs compared to other technologies. This manuscript discusses the challenges and limitations of current upper limb prosthetic devices and evaluates their functionality through a standard functional assessment, the Assessment of Capacity for Myoelectric Control (ACMC). To include a good representation of technologies, the authors collect information from participants in the Cybathlon Powered Arm Prostheses Race 2016 and 2020. The article analyzes 7 hour and 41 min of video footage to evaluate the performance of different prosthetic devices in various tasks inspired by activities of daily living (ADL). The results show that commercially-available rigid hands perform well in dexterous grasping, while body-powered solutions are more reliable and convenient for competitive environments. The article also highlights the importance of wrist design and control modality for successful execution of ADL. Moreover, we discuss the limitations of the evaluation methodology and suggest improvements for future assessments. With regard to future development, this work highlights the need for research in intuitive control of multiple degrees of freedom, adaptive solutions, and the integration of sensory feedback.


Assuntos
Amputados , Membros Artificiais , Humanos , Atividades Cotidianas , Desenho de Prótese , Extremidade Superior , Mãos
6.
J Neuroeng Rehabil ; 20(1): 20, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36755249

RESUMO

BACKGROUND: Among commercially-available upper-limb prostheses, the two most often used solutions are simple hook-style grippers and poly-articulated hands, which present a higher number of articulations and show a closer resemblance to biological limbs. In their majority, the former type of prostheses is body-powered, while the second type is controlled by myoelectric signals. Body-powered grippers are easy to control and allow a simple form of force feedback, frequently appreciated by users. However, they present limited versatility. Poly-articulated hands afford a wide range of grasp and manipulation types, but require enough residual muscle activation for dexterous control. Several factors, e.g. level of limb loss, personal preferences, cost, current occupation, and hobbies can influence the preference for one option over the other, and is always a result of the trade-off between system performance and users' needs. METHODS: The SoftHand Pro (SHP) is an artificial hand platform that has 19 independent joints (degrees-of-freedom), but is controlled by a single input. The design of this prosthesis is inspired by the concept of postural synergies in motor control and implemented with soft-robotic technologies. Their combination provides increased robustness, safe interaction and the execution of diverse grasps. The potential of the SHP is fully unleashed when users learn how to exploit its features and create an intimate relationship between the technical aspects of the prosthesis design and its control by the user. RESULTS: The great versatility of the SoftHand Pro (a reasearch protpotype) permitted its adaptation to the user requirements. This was experienced by the SoftHand Pro Team during the preparation for different CYBATHLON events (from 2016 to 2020). The mixed power and dexterous hand operations required by each task of the race is inspired by everyday tasks. Our prosthesis was driven by different pilots, with different habits and backgrounds. Consequently, the hand control modality was customized according to the user's preferences. Furthermore, the CYBATHLON tasks had some variations in this period, promoting the continuous development of our technology with a user-centered approach. In this paper, we describe the participation and preparation of the SoftHand Pro Team from 2016 to 2020 with three pilots and two different activation modalities, hybrid body-controlled and myoelectric control. CONCLUSIONS: We introduced our pilots, the implementation of the two control modalities, and describe the successful participation in all CYBATHLON events. This work proves the versatility of the system towards the user's preferences and the changes in the race requirements. Finally, we discussed how the CYBATHLON experience and the training in the real-world scenario have driven the evolution of our system and gave us remarkable insights for future perspectives.


Assuntos
Amputados , Membros Artificiais , Humanos , Desenho de Prótese , Mãos/fisiologia , Músculos
7.
Sci Rep ; 12(1): 21504, 2022 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-36513775

RESUMO

In patients with subacute stroke, task specific training (TST) has been shown to accelerate functional recovery of the upper limb. However, many patients do not have sufficient active extension of the fingers to perform this treatment. In these patients, here we propose a new rehabilitation technique in which TST is performed through a soft robotic hand (SoftHand-X). In short, the extension of the robotic fingers is controlled by the patient through his residual, albeit minimal, active extension of the fingers or wrist, while the patient was required to relax the muscles to achieve full flexion of the robotic fingers. TST with SoftHand-X was attempted in 27 subacute stroke patients unable to perform TST due to insufficient active extension of the fingers. Four patients (14.8%) were able to perform the proposed treatment (10 daily sessions of 60 min each). They reported an excellent level of participation. After the treatment, both clinical score of spasticity and its electromyographic correlate (stretch reflex) decreased. In subacute stroke patients, TST using SoftHand-X is a well-accepted treatment, resulting in a decrease of spasticity. At present, it can be applied only in a small proportion of the patients who cannot perform conventional TST, though extensions are possible.


Assuntos
Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Reabilitação do Acidente Vascular Cerebral/métodos , Projetos Piloto , Extremidade Superior , Mãos , Espasticidade Muscular , Resultado do Tratamento
9.
Front Robot AI ; 9: 817870, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36743293

RESUMO

Robots that work in unstructured scenarios are often subjected to collisions with the environment or external agents. Accordingly, recently, researchers focused on designing robust and resilient systems. This work presents a framework that quantitatively assesses the balancing resilience of self-stabilizing robots subjected to external perturbations. Our proposed framework consists of a set of novel Performance Indicators (PIs), experimental protocols for the reliable and repeatable measurement of the PIs, and a novel testbed to execute the protocols. The design of the testbed, the control structure, the post-processing software, and all the documentation related to the performance indicators and protocols are provided as open-source material so that other institutions can replicate the system. As an example of the application of our method, we report a set of experimental tests on a two-wheeled humanoid robot, with an experimental campaign of more than 1100 tests. The investigation demonstrates high repeatability and efficacy in executing reliable and precise perturbations.

10.
Sci Rep ; 11(1): 23952, 2021 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-34907228

RESUMO

Notwithstanding the advancement of modern bionic hands and the large variety of prosthetic hands in the market, commercial devices still present limited acceptance and percentage of daily use. While commercial prostheses present rigid mechanical structures, emerging trends in the design of robotic hands are moving towards soft technologies. Although this approach is inspired by nature and could be promising for prosthetic applications, there is scant literature concerning its benefits for end-users and in real-life scenarios. In this work, we evaluate and assess the role and the benefits of soft robotic technologies in the field of prosthetics. We propose a thorough comparison between rigid and soft characteristics of two poly-articulated hands in 5 non-expert myo-electric prosthesis users in pre- and post-therapeutic training conditions. The protocol includes two standard functional assessments, three surveys for user-perception, and three customized tests to evaluate the sense of embodiment. Results highlight that rigid hands provide a more precise grasp, while soft properties show higher functionalities thanks to their adaptability to different requirements, intuitive use and more natural execution of activities of daily living. This comprehensive evaluation suggests that softness could also promote a quick integration of the system in non-expert users.

11.
Front Neurorobot ; 15: 683253, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34803645

RESUMO

Poly-articulated hands, actuated by multiple motors and controlled by surface myoelectric technologies, represent the most advanced aids among commercial prostheses. However, simple hook-like body-powered solutions are still preferred for their robustness and control reliability, especially for challenging environments (such as those encountered in manual work or developing countries). This study presents the mechatronic implementation and the usability assessment of the SoftHand Pro-Hybrid, a family of poly-articulated, electrically-actuated, and body-controlled artificial hands, which combines the main advantages of both body-powered and myoelectric systems in a single device. An assessment of the proposed system is performed with individuals with and without limb loss, using as a benchmark the SoftHand Pro, which shares the same soft mechanical architecture, but is controlled using surface electromyographic sensors. Results indicate comparable task performance between the two control methods and suggest the potential of the SoftHand Pro-Hybrid configurations as a viable alternative to myoelectric control, especially in work and demanding environments.

12.
Front Robot AI ; 8: 713083, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34458326

RESUMO

To enable the design of planning and control strategies in simulated environments before their direct application to the real robot, exploiting the Sim2Real practice, powerful and realistic dynamic simulation tools have been proposed, e.g., the ROS-Gazebo framework. However, the majority of such simulators do not account for some of the properties of recently developed advanced systems, e.g., dynamic elastic behaviors shown by all those robots that purposely incorporate compliant elements into their actuators, the so-called Articulated Soft Robots ASRs. This paper presents an open-source ROS-Gazebo toolbox for simulating ASRs equipped with the aforementioned types of compliant actuators. To achieve this result, the toolbox consists of two ROS-Gazebo modules: a plugin that implements the custom compliant characteristics of a given actuator and simulates the internal motor dynamics, and a Robotic Operation System (ROS) manager node used to organize and simplify the overall toolbox usage. The toolbox can implement different compliant joint structures to perform realistic and representative simulations of ASRs, also when they interact with the environment. The simulated ASRs can be also used to retrieve information about the physical behavior of the real system from its simulation, and to develop control policies that can be transferred back to the real world, leveraging the Sim2Real practice. To assess the versatility of the proposed plugin, we report simulations of different compliant actuators. Then, to show the reliability of the simulated results, we present experiments executed on two ASRs and compare the performance of the real hardware with the simulations. Finally, to validate the toolbox effectiveness for Sim2Real control design, we learn a control policy in simulation, then feed it to the real system in feed-forward comparing the results.

13.
Front Robot AI ; 8: 661354, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34179107

RESUMO

Upper-limb impairments are all-pervasive in Activities of Daily Living (ADLs). As a consequence, people affected by a loss of arm function must endure severe limitations. To compensate for the lack of a functional arm and hand, we developed a wearable system that combines different assistive technologies including sensing, haptics, orthotics and robotics. The result is a device that helps lifting the forearm by means of a passive exoskeleton and improves the grasping ability of the impaired hand by employing a wearable robotic supernumerary finger. A pilot study involving 3 patients, which was conducted to test the capability of the device to assist in performing ADLs, confirmed its usefulness and serves as a first step in the investigation of novel paradigms for robotic assistance.

14.
Front Robot AI ; 8: 614145, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33791339

RESUMO

Living beings modulate the impedance of their joints to interact proficiently, robustly, and safely with the environment. These observations inspired the design of soft articulated robots with the development of Variable Impedance and Variable Stiffness Actuators. However, designing them remains a challenging task due to their mechanical complexity, encumbrance, and weight, but also due to the different specifications that the wide range of applications requires. For instance, as prostheses or parts of humanoid systems, there is currently a need for multi-degree-of-freedom joints that have abilities similar to those of human articulations. Toward this goal, we propose a new compact and configurable design for a two-degree-of-freedom variable stiffness joint that can match the passive behavior of a human wrist and ankle. Using only three motors, this joint can control its equilibrium orientation around two perpendicular axes and its overall stiffness as a one-dimensional parameter, like the co-contraction of human muscles. The kinematic architecture builds upon a state-of-the-art rigid parallel mechanism with the addition of nonlinear elastic elements to allow the control of the stiffness. The mechanical parameters of the proposed system can be optimized to match desired passive compliant behaviors and to fit various applications (e.g., prosthetic wrists or ankles, artificial wrists, etc.). After describing the joint structure, we detail the kinetostatic analysis to derive the compliant behavior as a function of the design parameters and to prove the variable stiffness ability of the system. Besides, we provide sets of design parameters to match the passive compliance of either a human wrist or ankle. Moreover, to show the versatility of the proposed joint architecture and as guidelines for the future designer, we describe the influence of the main design parameters on the system stiffness characteristic and show the potential of the design for more complex applications.

15.
Wearable Technol ; 2: e5, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-38486629

RESUMO

Force feedback is often beneficial for robotic teleoperation, as it enhances the user's remote perception. Over the years, many kinesthetic haptic displays (KHDs) have been proposed for this purpose, which have different types of interaction and feedback, depending on their kinematics and their interface with the operator, including, for example, grounded and wearable devices acting either at the joint or operational space (OS) level. Most KHDs in the literature are for the upper limb, with a majority acting at the shoulder/elbow level, and others focusing on hand movements. A minority exists which addresses wrist motions. In this paper, we present the Wearable Delta (W), a proof-of-concept wearable wrist interface with hybrid parallel-serial kinematics acting in the OS, able to render a desired force directly to the hand involving just the forearm-hand subsystem. It has six degrees of freedom (DoFs), three of which are actuated, and is designed to reduce the obstruction of the range of the user's wrist. Integrated with positions/inertial sensors at the elbow and upper arm, the W allows the remote control of a full articulated robotic arm. The paper covers the whole designing process, from the concept to the validation, as well as a multisubject experimental campaign that investigates its usability. Finally, it presents a section that, starting from the experimental results, aims to discuss and summarize the W advantages and limitations and look for possible future improvements and research directions.

16.
Front Neurorobot ; 14: 33, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32670044

RESUMO

To physically interact with a rich variety of environments and to match situation-dependent requirements, humans adapt both the force and stiffness of their limbs. Reflecting this behavior in prostheses may promote a more natural and intuitive control and, consequently, improve prostheses acceptance in everyday life. This pilot study proposes a method to control a prosthetic robot hand and its impedance, and explores the utility of variable stiffness when performing activities of daily living and physical social interactions. The proposed method is capable of a simultaneous and proportional decoding of position and stiffness intentions from two surface electro-myographic sensors placed over a pair of antagonistic muscles. The feasibility of our approach is validated and compared to existing control modalities in a preliminary study involving one prosthesis user. The algorithm is implemented in a soft under-actuated prosthetic hand (SoftHand Pro). Then, we evaluate the usability of the proposed approach while executing a variety of tasks. Among these tasks, the user interacts with other 12 able-bodied subjects, whose experiences were also assessed. Several statistically significant aspects from the System Usability Scale indicate user's preference of variable stiffness control over low or high constant stiffness due to its reactivity and adaptability. Feedback reported by able-bodied subjects reveal a general tendency to favor soft interaction, i.e., low stiffness, which is perceived more human-like and comfortable. These combined results suggest the use of variable stiffness as a viable compromise between firm control and safe interaction which is worth investigating further.

17.
Front Robot AI ; 7: 587759, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33501345

RESUMO

Recently, extratheses, aka Supernumerary Robotic Limbs (SRLs), are emerging as a new trend in the field of assistive and rehabilitation devices. We proposed the SoftHand X, a system composed of an anthropomorphic soft hand extrathesis, with a gravity support boom and a control interface for the patient. In preliminary tests, the system exhibited a positive outlook toward assisting impaired people during daily life activities and fighting learned-non-use of the impaired arm. However, similar to many robot-aided therapies, the use of the system may induce side effects that can be detrimental and worsen patients' conditions. One of the most common is the onset of alternative grasping strategies and compensatory movements, which clinicians absolutely need to counter in physical therapy. Before embarking in systematic experimentation with the SoftHand X on patients, it is essential that the system is demonstrated not to lead to an increase of compensation habits. This paper provides a detailed description of the compensatory movements performed by healthy subjects using the SoftHand X. Eleven right-handed healthy subjects were involved within an experimental protocol in which kinematic data of the upper body and EMG signals of the arm were acquired. Each subject executed tasks with and without the robotic system, considering this last situation as reference of optimal behavior. A comparison between two different configurations of the robotic hand was performed to understand if this aspect may affect the compensatory movements. Results demonstrated that the use of the apparatus reduces the range of motion of the wrist, elbow and shoulder, while it increases the range of the trunk and head movements. On the other hand, EMG analysis indicated that muscle activation was very similar among all the conditions. Results obtained suggest that the system may be used as assistive device without causing an over-use of the arm joints, and opens the way to clinical trials with patients.

18.
Front Neurorobot ; 13: 26, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31191285

RESUMO

Proportional and simultaneous control algorithms are considered as one of the most effective ways of mapping electromyographic signals to an artificial device. However, the applicability of these methods is limited by the high number of electromyographic features that they require to operate-typically twice as many the actuators to be controlled. Indeed, extracting many independent electromyographic signals is challenging for a number of reasons-ranging from technological to anatomical. On the contrary, the number of actively moving parts in classic prostheses or extra-limbs is often high. This paper faces this issue, by proposing and experimentally assessing a set of algorithms which are capable of proportionally and simultaneously control as many actuators as there are independent electromyographic signals available. Two sets of solutions are considered. The first uses as input electromyographic signals only, while the second adds postural measurements to the sources of information. At first, all the proposed algorithms are experimentally tested in terms of precision, efficiency, and usability on twelve able-bodied subjects, in a virtual environment. A state-of-the-art controller using twice the amount of electromyographic signals as input is adopted as benchmark. We then performed qualitative tests, where the maps are used to control a prototype of upper limb prosthesis. The device is composed of a robotic hand and a wrist implementing active prono-supination movement. Eight able-bodied subjects participated to this second round of testings. Finally, the proposed strategies were tested in exploratory experiments involving two subjects with limb loss. Results coming from the evaluations in virtual and realistic settings show encouraging results and suggest the effectiveness of the proposed approach.

19.
Front Robot AI ; 6: 23, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-33501039

RESUMO

Inspired by nature, soft robotics aims at enhancing robots capabilities through the use of soft materials. This article presents the study of soft continuum robots which can change their dynamic behavior thanks to a proper design of their damping properties. It enables an under-actuated dynamic strategy to control multi-chamber pneumatic systems using a reduced number of feeding lines. The present work starts from the conceptual investigation of a way to tune the damping properties of soft continuum robots, and leverages on the introduction of viscous fluid within the soft chamber wall to produce dissipative actions. Several solutions are analyzed in simulations and the most promising one is tested experimentally. The proposed approach employs a layer of granular material immersed in viscous silicone oil to increase the damping effect. After validation and experimental characterization, the method is employed to build soft continuum actuators with different deformation patterns, i.e., extending, contracting and bending. Experimental results show the dynamic behavior of the presented actuators. Finally, the work reports information on how the actuators are designed and builded, together with a discussion about possible applications and uses.

20.
PLoS One ; 13(10): e0205653, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30321204

RESUMO

Roughly one quarter of active upper limb prosthetic technology is rejected by the user, and user surveys have identified key areas requiring improvement: function, comfort, cost, durability, and appearance. Here we present the first systematic, clinical assessment of a novel prosthetic hand, the SoftHand Pro (SHP), in participants with transradial amputation and age-matched, limb-intact participants. The SHP is a robust and functional prosthetic hand that minimizes cost and weight using an underactuated design with a single motor. Participants with limb loss were evaluated on functional clinical measures before and after a 6-8 hour training period with the SHP as well as with their own prosthesis; limb-intact participants were tested only before and after SHP training. Participants with limb loss also evaluated their own prosthesis and the SHP (following training) using subjective questionnaires. Both objective and subjective results were positive and illuminated the strengths and weaknesses of the SHP. In particular, results pre-training show the SHP is easy to use, and significant improvement in the Activities Measure for Upper Limb Amputees in both groups following a 6-8 hour training highlights the ease of learning the unique features of the SHP (median improvement: 4.71 and 3.26 and p = 0.009 and 0.036 for limb loss and limb-intact groups, respectively). Further, we found no difference in performance compared to participant's own commercial devices in several clinical measures and found performance surpassing these devices on two functional tasks, buttoning a shirt and using a cell phone, suggesting a functional prosthetic design. Finally, improvements are needed in the SHP design and/or training in light of poor results in small object manipulation. Taken together, these results show the promise of the SHP, a flexible and adaptive prosthetic hand, and pave a path forward to ensuring higher functionality in future.


Assuntos
Membros Artificiais , Atividades Cotidianas , Adulto , Idoso , Amputação Traumática , Feminino , Mãos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Robótica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...