Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 95(44): e5225, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27858870

RESUMO

Rapidly progressive glomerulonephritis (RPGN) is mainly caused by anti-glomerular basement membrane (GBM) antibody-mediated glomerulonephritis, immune-complex or anti-neutrophil cytoplasmic antibody (ANCA)-associated vasculitides and leads to rapid loss of renal function. Detection of ANCA and autoantibodies (autoAbs) to GBM and dsDNA enables early diagnosis and appropriate treatment of RPGN aiding in preventing end-stage renal disease.Determination of ANCA on neutrophils (ANCA) as well as autoAbs to myeloperoxidase (MPO-ANCA), proteinase 3 (PR3-ANCA), GBM, and dsDNA was performed by the novel multiplex CytoBead technology combining cell- and microbead-based autoAb analyses by automated indirect immunofluorescence (IIF). Forty patients with granulomatosis with polyangiitis (GPA), 48 with microscopic polyangiitis (MPA), 2 with eosinophilic GPA, 42 with systemic lupus erythematosus (SLE), 43 with Goodpasture syndrome (GPS), 57 with infectious diseases (INF), and 55 healthy subjects (HS) were analyzed and findings compared with classical single testing.The CytoBead assay revealed for GPA, MPA, GPS, and SLE the following diagnostic sensitivities and for HS and INF the corresponding specificities: PR3-ANCA, 85.0% and 100.0%; MPO-ANCA, 77.1% and 99.1%; anti-GBM autoAb, 88.4% and 96.4%; anti-dsDNA autoAb, 83.3% and 97.3%; ANCA, 91.1% and 99.1%, respectively. Agreement with classical enzyme-linked immunosorbent assay and IIF was very good for anti-GBM autoAb, MPO-ANCA, PR3-ANCA, and ANCA, respectively. Anti-dsDNA autoAb comparative analysis demonstrated fair agreement only and a significant difference (P = 0.0001).The CytoBead technology provides a unique multiplex reaction environment for simultaneous RPGN-specific autoAb testing. CytoBead RPGN assay is a promising alternative to time-consuming single parameter analysis and, thus, is well suited for emergency situations.


Assuntos
Anticorpos Anticitoplasma de Neutrófilos/análise , Glomerulonefrite/sangue , Glomerulonefrite/imunologia , Neutrófilos/química , Adulto , Idoso , Estudos de Casos e Controles , Pré-Escolar , Progressão da Doença , Feminino , Técnica Indireta de Fluorescência para Anticorpo , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
2.
Auto Immun Highlights ; 7(1): 2, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26831868

RESUMO

PURPOSE: Celiac disease (CD) serology requires analysis of tissue transglutaminase type-2 (TG2autoAbs), deamidated gliadin (DGAbs), and as reference endomysial autoantibodies (EmA). Total IgA assessment helps to determine IgA-deficient CD patients. The novel multiplex indirect immunofluorescence (IIF) technique CytoBead was used to develop the first quantitative one-step serological CD assay comprising both simultaneous IgA autoAb and total IgA testing. METHODS: CytoBead CeliAK detecting TG2autoAb, DGAb, EmA, and simultaneously total IgA uses fluorescent microparticles for antigen and antibody immobilization along with monkey-esophagus tissue sections on glass slides. The assay was interpreted visually by classical fluorescent microscopy and digital IIF using AKLIDES(®). Overall, 380 samples (155 CD patients, 5 with IgA deficiency, 68 with cystic fibrosis, 59 with eye disease, 93 blood donors) were run for performance analysis. Data were compared with classical IgA autoAb analysis by ELISA and IIF. RESULTS: Comparing CD-specific IgA autoAb testing by CytoBead with classical IIF and ELISA, very good agreements for EmA, TG2autoAb, and DGAb were determined (Cohen's κ = 0.98, 0.96, 0.85, respectively). The difference between multiplex and single testing revealed a significant difference for TG2autoAb testing only (McNemar, p = 0.0078). Four CD patients and 4 controls demonstrated TG2autoAb positivity by ELISA but were negative by CytoBead. Further, 140/155 (90.9 %) CD patients demonstrated TG2autoAb levels above ten times the upper normal and all five IgA-deficient samples IgA levels <0.2 g/L by CytoBead. CONCLUSIONS: The novel multiplex CytoBead CeliAK enables simultaneous CD-specific autoAb and IgA deficiency analyses comparable with classical testing by single-parameter assays. Thus, comprehensive CD serology by CytoBead can alleviate the workload in routine laboratories.

3.
Methods Mol Biol ; 1312: 165-73, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26044001

RESUMO

Sera of tumor patients frequently contain autoantibodies to tumor associated antigens. Here we describe a miniaturized immunoblot platform allowing us to screen sera of patients for the presence of autoantibodies to ten autoantigens in parallel.


Assuntos
Autoanticorpos/análise , Western Blotting/métodos , Miniaturização/métodos , Autoanticorpos/química , Autoanticorpos/genética , Autoanticorpos/imunologia , Autoantígenos/imunologia , Bactérias/genética , Eletroforese em Gel de Poliacrilamida , Histidina/química , Humanos , Fatores de Tempo
4.
Clin Chem Lab Med ; 53(12): 1991-2002, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26020561

RESUMO

BACKGROUND: For the serological diagnosis of systemic autoimmune rheumatic diseases, a two-tier approach starting with sensitive antinuclear antibody (ANA) detection by indirect immunofluorescence (IIF) on HEp-2 cells followed by characterization of positive findings with different immunoassays is recommended. To overcome drawbacks of this approach, we developed a novel technique allowing the combination of screening and simultaneous confirmatory testing. For the first time, this creates the basis for second generation ANA testing. METHODS: ANA and autoantibodies (autoAbs) to double-stranded DNA (dsDNA), CENP-B, SS-A/Ro52, SS-A/Ro60, SS-B/La, RNP-Sm, Sm, and Scl-70 were determined by IIF and enzyme-linked immunosorbent assay (ELISA), respectively, and compared to simultaneous analysis thereof by second generation ANA analysis in patients with systemic lupus erythematosus (n=174), systemic sclerosis (n=103), Sjögren's syndrome (n=46), rheumatoid arthritis (n=36), mixed and undetermined connective tissue diseases (n=13), myositis (n=21), infectious disease (n=21), autoimmune liver disease (n=93), inflammatory bowel disease (n=78), paraproteinemia (n=11), and blood donors (n=101). RESULTS: There was very good agreement of second generation ANA testing with classical one by IIF and ELISA regarding testing for ANA and autoAbs to dsDNA, CENP-B, SS-B, RNP-Sm, Scl-70, SS-A/Ro52, and SS-A/Ro60 (Cohen's κ>0.8). The agreement for anti-Sm autoAb was good (κ=0.77). The differences of both approaches were not significant for autoAbs to SS-B/La, RNP-Sm, Scl-70, SS-A/Ro60, and SS-A/Ro52 (McNemar's test, p>0.05, respectively). CONCLUSIONS: Second generation ANA testing can replace the two-tier analysis by combining IIF screening with multiplex confirmative testing. This addresses shortcomings of classical ANA analysis like false-negative ANA findings and lack of laboratory efficiency and standardization.


Assuntos
Anticorpos Antinucleares/sangue , Doenças Autoimunes/diagnóstico , Imunoensaio , Doenças Reumáticas/diagnóstico , Doenças Autoimunes/sangue , Doenças Autoimunes/imunologia , Técnica Indireta de Fluorescência para Anticorpo , Células Hep G2 , Humanos , Doenças Reumáticas/sangue , Doenças Reumáticas/imunologia
6.
PLoS One ; 9(9): e107743, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25225805

RESUMO

Anti-neutrophil cytoplasmic antibodies (ANCA) are the serological hallmark of small vessel vasculitis, so called ANCA-associated vasculitis. The international consensus requires testing by indirect immunofluorescence (IIF) on human ethanol-fixed neutrophils (ethN) as screening followed by confirmation with enzyme-linked immunosorbent assays (ELISAs). This study evaluates the combination of cell- and microbead-based digital IIF analysis of ANCA in one reaction environment by the novel multiplexing CytoBead technology for simultaneous screening and confirmatory ANCA testing. Sera of 592 individuals including 118 patients with ANCA-associated vasculitis, 133 with rheumatoid arthritis, 49 with infectious diseases, 77 with inflammatory bowel syndrome, 20 with autoimmune liver diseases, 70 with primary sclerosing cholangitis and 125 blood donors were tested for cytoplasmic ANCA (C-ANCA) and perinuclear ANCA (P-ANCA) by classical IIF and ANCA to proteinase 3 (PR3) and myeloperoxidase (MPO) by ELISA. These findings were compared to respective ANCA results determined by automated multiplex CytoBead technology using ethN and antigen-coated microbeads for microbead immunoassays. There was a good agreement for PR3- and MPO-ANCA and a very good one for P-ANCA and C-ANCA by classical and multiplex analysis (Cohen's kappa [κ] = 0.775, 0.720, 0.876, 0.820, respectively). The differences between classical testing and CytoBead analysis were not significant for PR3-ANCA, P-ANCA, and C-ANCA (p<0.05, respectively). The prevalence of confirmed positive ANCA findings by classical testing (IIF and ELISA) compared with multiplex CytoBead analysis (IIF and microbead immunoassay positive) resulted in a very good agreement (κ = 0.831) with no significant difference of both methods (p = 0.735). Automated endpoint-ANCA titer detection in one dilution demonstrated a very good agreement with classical analysis requiring dilution of samples (κ = 0.985). Multiplexing by CytoBead technology can be employed for simultaneous screening and quantitative confirmation of ANCA. This novel technique provides fast and cost-effective ANCA analysis by automated digital IIF for the first time.


Assuntos
Anticorpos Anticitoplasma de Neutrófilos/imunologia , Vasculite/diagnóstico , Vasculite/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Feminino , Técnica Indireta de Fluorescência para Anticorpo/métodos , Técnica Indireta de Fluorescência para Anticorpo/normas , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
7.
Arthritis Res Ther ; 14(6): R271, 2012 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-23241527

RESUMO

INTRODUCTION: Indirect immunofluorescence (IIF) employing ethanol-fixed neutrophils (ethN) is still the method of choice for assessing antineutrophil cytoplasmic antibodies (ANCA) in ANCA-associated vasculitides (AAV). However, conventional fluorescence microscopy is subjective and prone to high variability. The objective of this study was to evaluate novel pattern recognition algorithms for the standardized automated interpretation of ANCA patterns. METHODS: Seventy ANCA-positive samples (20 antimyeloperoxidase ANCA, 50 antiproteinase3 ANCA) and 100 controls from healthy individuals analyzed on ethN and formalin-fixed neutrophils (formN) by IIF were used as a 'training set' for the development of pattern recognition algorithms. Sera from 342 patients ('test set') with AAV and other systemic rheumatic and infectious diseases were tested for ANCA patterns using the novel pattern recognition algorithms and conventional fluorescence microscopy. RESULTS: Interpretation software employing pattern recognition algorithms was developed enabling positive/negative discrimination and classification of cytoplasmic ANCA (C-ANCA) and perinuclear ANCA (P-ANCA). Comparison of visual reading of the 'test set' samples with automated interpretation revealed Cohen's kappa (κ) values of 0.955 on ethN and 0.929 on formN for positive/negative discrimination. Analysis of the 'test set' with regard to the discrimination between C-ANCA and P-ANCA patterns showed a high agreement for ethN (κ = 0.746) and formN (κ = 0.847). There was no significant difference between visual and automated interpretation regarding positive/negative discrimination on ethN and formN, as well as ANCA pattern recognition (P > 0.05, respectively). CONCLUSIONS: Pattern recognition algorithms can assist in the automated interpretation of ANCA IIF. Automated reading of ethN and formN IIF patterns demonstrated high consistency with visual ANCA assessment.


Assuntos
Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/sangue , Vasculite Associada a Anticorpo Anticitoplasma de Neutrófilos/diagnóstico , Anticorpos Anticitoplasma de Neutrófilos/sangue , Técnica Indireta de Fluorescência para Anticorpo/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Processamento Eletrônico de Dados , Feminino , Humanos , Masculino , Microscopia de Fluorescência , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Software , Adulto Jovem
8.
Anal Chem ; 83(9): 3379-85, 2011 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-21413805

RESUMO

Microbead-based assays have evolved into powerful tools for the multiplex detection of biomolecules. Analytes are captured by DNA or protein capture molecules which are coupled on microbead surfaces. A homogeneous carboxylation of microbeads is essential for the optimal and reproducible coupling of capture molecules and thus a prerequisite for an optimal multiplex microbead-based assay performance. We developed a simple fluorescence dye adsorption assay for the description of microbead carboxylation and for the prediction of coupling successes of capture molecules. Using the fluorescence dye SYTO-62 it is possible to quantify the degree of carboxylation of poly(methyl methacrylate) (PMMA) microbeads within 1 h in a multiplex format by fluorescence microscopy or flow cytometry. Compared to conventional bulk assays which only provide an average degree of carboxylation the main advantage of the SYTO-62 assay is the single microbead analysis and therefore the description of the qualitative distribution of carboxylation in microbead populations. The SYTO-62 assay is sensitive enough to even determine weak carboxylation. Also, the quality of microbeads can be evaluated. To our knowledge this is the first report which applies a reversible noncovalent fluorescent dye adsorption assay to quantify the degree of carboxylation on surfaces.


Assuntos
Dióxido de Carbono/análise , Corantes Fluorescentes/química , Microesferas , Polimetil Metacrilato/química , Adsorção , Dióxido de Carbono/química , Citometria de Fluxo , Concentração de Íons de Hidrogênio , Sondas de Oligonucleotídeos/química , Controle de Qualidade , Estreptavidina/química , Propriedades de Superfície , Fatores de Tempo
9.
Cytometry A ; 79(2): 118-25, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21265005

RESUMO

Advances in immunofluorescence assay development paved the way for the simultaneous detection of several antibodies in one sample, for the serological diagnosis of systemic rheumatic diseases. Standardized automated screening of such antibodies can be achieved by HEp-2 cell-based indirect immunofluorescence (IIF) using a multicolor fluorescence imaging technical platform. To create a common platform for both screening and specific antibody assessment, multiplex measurement of antibodies using fluorescence-coded immobilized microbeads was employed on the same platform. The multicolor fluorescence detection system VideoScan (AKLIDES®) was used for the fluorescence analysis of a multiplex microbead-based immunoassay (MIA). First, immunoglobulin G (IgG) was covalently coupled to one microbead population in duplicate and in three independent experiments. The coupled IgG was detected by a Cy™5-conjugated secondary antibody. Thus, intra- and interassay coefficients of variation (CV) were obtained. Second, a multiplex determination of antinuclear autoantibodies (ANA) to Scl-70, Sm, dsDNA, SS-A (Ro60), CENP-B, and La/SS-B by solid-phase MIA was investigated, using 72 sera from patients with autoimmune diseases such as systemic lupus erythematosus and systemic sclerosis (SS). The reproducibility study revealed intra-assay CVs ranging from 3.2% to 9.9%, and interassay CVs ranging from 9.6% to 14.7%. The detection of Scl-70-, Sm-, CENP-B-, and La/SS-B-ANA with MIA showed very good agreement with the ELISA results (kappa = 1.0). The resulting relative sensitivities and specificities for Scl-70-, Sm-, CENP-B-, dsDNA-, and La/SS-B-ANA were 100%, respectively, with the exception of dsDNA (specificity 97%). Multiplex detection by immobilized fluorescence-coded microbeads using multicolor fluorescence is a reliable method for the assessment of rheumatic-disease-specific antibodies. Multicolor fluorescence analyses with pattern detection algorithms provide a common platform technique for both the screening of ANA by cell-based IIF and specific antibody assessment by multiplex detection.


Assuntos
Autoanticorpos/análise , Técnica Indireta de Fluorescência para Anticorpo/métodos , Imunoensaio/métodos , Microesferas , Doenças Reumáticas/imunologia , Adulto , Anticorpos Antinucleares/análise , Anticorpos Antinucleares/sangue , Especificidade de Anticorpos , Antígenos Nucleares/análise , Antígenos Nucleares/imunologia , Autoanticorpos/sangue , Autoanticorpos/imunologia , DNA/análise , DNA/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Feminino , Humanos , Imunoglobulina G/imunologia , Masculino , Microscopia de Fluorescência por Excitação Multifotônica/métodos , Pessoa de Meia-Idade , Doenças Reumáticas/sangue , Sensibilidade e Especificidade , Testes Sorológicos/métodos
10.
Methods Mol Biol ; 536: 129-37, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19378052

RESUMO

Sera of tumor patients frequently contain autoantibodies to tumor-associated antigens. Here we describe a miniaturized immunoblot platform allowing us to screen sera of patients for the presence of autoantibodies to ten autoantigens in parallel.


Assuntos
Autoanticorpos/imunologia , Immunoblotting , Autoanticorpos/genética , Autoantígenos/imunologia , Humanos , Immunoblotting/instrumentação , Immunoblotting/métodos , Proteínas Recombinantes de Fusão/genética , Proteínas Recombinantes de Fusão/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...