Arterial prosthetic graft infection is one of the most challenging issues in vascular surgery. We report a case of an infected descending thoracic aorta endograft, presenting itself several years after placement, with hemoptysis and back pain as referred symptoms. The patient was successfully treated by removing the thoracic aorta and replacing the infected endografts with a cryopreserved aortic allograft, running from the left subclavian artery to the aortic diaphragmatic hiatus.


Assuntos
Aorta Torácica/cirurgia , Aorta/transplante , Bioprótese , Implante de Prótese Vascular/efeitos adversos , Prótese Vascular/efeitos adversos , Criopreservação , Procedimentos Endovasculares/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Stents , Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , Dor nas Costas/etiologia , Implante de Prótese Vascular/instrumentação , Remoção de Dispositivo , Procedimentos Endovasculares/instrumentação , Hemoptise/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/etiologia , Reoperação , Tomografia Computadorizada por Raios X , Transplante Homólogo , Resultado do Tratamento