Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Physiol Meas ; 38(2): 374-386, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28134135

RESUMO

The differences and commonalities between x-ray fluorescence results obtained using synchrotron radiation and a portable x-ray fluorescence device were examined using arsenic in soft tissue phantoms and lead in bone phantoms. A monochromatic beam energy of 15.8 keV was used with the synchrotron, while the portable device employed a rhodium anode x-ray tube operated at 40 kV. Bone phantoms, dosed with varying quantities of lead, were made of Plaster of Paris and placed underneath skin phantoms of either 3.1 mm or 3.9 mm thickness. These skin phantoms were constructed from polyester resin, and dosed with varying amounts of arsenic. Using an irradiation time of 120 s, arsenic Kα and Kß, and lead Lα and Lß characteristic x-ray peaks were analysed. This information was used to calculate calibration line slopes and minimum detection limits for each data set. As expected, minimum detection limits were much lower at the synchrotron for detecting arsenic and lead. Both approaches produced lower detection limits for arsenic in soft tissue than for lead in bone when simultaneous detection was attempted. Although arsenic Kα and lead Lα emissions share similar energies, it was possible to detect both elements in isolation by using the arsenic Kß and lead Lß characteristic x-rays. Greater thickness of soft tissue phantom reduced the ability to detect the underlying lead. Experiments with synchrotron radiation could help guide future efforts toward optimizing a portable x-ray fluorescence in vivo measurement device.


Assuntos
Arsênio/análise , Osso e Ossos/química , Chumbo/análise , Imagens de Fantasmas , Espectrometria por Raios X/instrumentação , Síncrotrons , Humanos , Limite de Detecção
2.
Appl Radiat Isot ; 120: 1-6, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27889549

RESUMO

The feasibility of measuring arsenic and selenium contents in a single nail clipping was investigated using a small-focus portable X-ray fluorescence (XRF) instrument with monochromatic excitation beams. Nail clipping phantoms supplemented with arsenic and selenium to produce materials with 0, 5, 10, 15, and 20µg/g were used for calibration purposes. In total, 10 different clippings were analyzed at two different measurement positions. Energy spectra were fit with detection peaks for arsenic Kα, selenium Kα, arsenic Kß, selenium Kß, and bromine Kα characteristic X-rays. Data analysis was performed under two distinct conditions of fitting constraint. Calibration lines were established from the amplitude of each of the arsenic and selenium peaks as a function of the elemental contents in the clippings. The slopes of the four calibration lines were consistent between the two conditions of analysis. The calculated minimum detection limit (MDL) of the method, when considering the Kα peak only, ranged from 0.210±0.002µg/g selenium under one condition of analysis to 0.777±0.009µg/g selenium under another. Compared with previous portable XRF nail clipping studies, MDLs were substantially improved for both arsenic and selenium. The new measurement technique had the additional benefits of being short in duration (~3min) and requiring only a single nail clipping. The mass of the individual clipping used did not appear to play a major role in signal strength, but positioning of the clipping is important.


Assuntos
Arsênio/análise , Unhas/química , Selênio/análise , Espectrometria por Raios X/instrumentação , Arsênio/toxicidade , Calibragem , Exposição Ambiental , Estudos de Viabilidade , Humanos , Limite de Detecção , Imagens de Fantasmas , Selênio/toxicidade , Espectrometria por Raios X/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...