Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Adv Clin Exp Med ; 33(5): 543-548, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38742745

RESUMO

BACKGROUND: Recent studies have revealed the usefulness of synovial calprotectin (CLP) in diagnosing chronic periprosthetic joint infections (PJIs). However, there is still a lack of evidence to support the use of serum CLP in the diagnosis of early PJIs and surgical site infections (SSIs) after total joint arthroplasties (TJAs). OBJECTIVES: The primary aim of this study is to investigate the standard kinetics of CLP concentrations in the blood during the very early postoperative period after non-complicated total hip arthroplasty (THA) and total knee arthroplasty (TKA). The secondary aim was to perform a preliminary comparison of CLP concentrations between non-infected patients and patients with recognized SSIs. MATERIAL AND METHODS: A total of 64 consecutive patients who underwent primary THA and TKA were included in this prospective research. Sixty patients (30 THA and 30 TKA) were scheduled to determine the standard shape of the blood CLP curve and the expected concentrations during the first 5 postoperative days after non-complicated TJAs. In 4 additonal patients, early SSI was confirmed, and they were included in a separate SSI subgroup. RESULTS: Calprotectin demonstrated a linear increase during the first 5 postoperative days. Statistically significant differences in CLP concentrations between non-infected cases and SSIs were not observed. The preoperative median results with interquartile range (Q1-Q3) were 0.52 (0.39-0.64) mg/dL and 0.5 (0.47-0.52) mg/dL (p = 0.77), while post operation they were as follows: on postoperative day 1: 0.88 (0.53-1.3) mg/dL and 0.86 (0.62-1.1) mg/dL (p = 0.84), on postoperative day 3: 1.77 (1.29-2.08) mg/dL and 1.85 (1.70-1.95) mg/dL (p = 0.72), and on postoperative day 5: 2.32 (1.79-2.67) mg/dL and 2.56 (2.25-2.83) mg/dL (p = 0.55), respectively. CONCLUSION: Serial CLP measurements during the early postoperative period revealed a linear (statistically significant) increase in concentration to postoperative day 5 without an evident point of decrease. A significant difference in median values and the course of curve patterns between the non-complicated and SSI groups was not observed.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Complexo Antígeno L1 Leucocitário , Infecção da Ferida Cirúrgica , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Feminino , Masculino , Idoso , Infecção da Ferida Cirúrgica/diagnóstico , Infecção da Ferida Cirúrgica/sangue , Infecção da Ferida Cirúrgica/etiologia , Complexo Antígeno L1 Leucocitário/análise , Complexo Antígeno L1 Leucocitário/sangue , Pessoa de Meia-Idade , Estudos Prospectivos , Biomarcadores/sangue , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/sangue , Idoso de 80 Anos ou mais
2.
Int J Mol Sci ; 25(10)2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38791242

RESUMO

The objective of this study was to investigate if delivering multiple doses of N-acetylcysteine (NAC) post-surgery in addition to pre-incisional administration significantly impacts the wound healing process in a rat model. Full-thickness skin incisions were carried out on the dorsum of 24 Sprague-Dawley rats in six locations. Fifteen minutes prior to the incision, half of the sites were treated with a control solution, with the wounds on the contralateral side treated with solutions containing 0.015%, 0.03% and 0.045% of NAC. In the case of the NAC treated group, further injections were given every 8 h for three days. On days 3, 7, 14 and 60 post-op, rats were sacrificed to gather material for the histological analysis, which included histomorphometry, collagen fiber organization analysis, immunohistochemistry and Abramov scale scoring. It was determined that scars treated with 0.015% NAC had significantly lower reepithelization than the control at day 60 post-op (p = 0.0018). Scars treated with 0.045% NAC had a significantly lower collagen fiber variance compared to 0.015% NAC at day 14 post-op (p = 0.02 and p = 0.04) and a lower mean scar width than the control at day 60 post-op (p = 0.0354 and p = 0.0224). No significant differences in the recruitment of immune cells and histological parameters were found. The results point to a limited efficacy of multiple NAC injections post-surgery in wound healing.


Assuntos
Acetilcisteína , Ratos Sprague-Dawley , Cicatrização , Animais , Cicatrização/efeitos dos fármacos , Acetilcisteína/farmacologia , Acetilcisteína/administração & dosagem , Ratos , Injeções Intradérmicas , Modelos Animais de Doenças , Pele/efeitos dos fármacos , Pele/patologia , Pele/lesões , Masculino , Ferida Cirúrgica/tratamento farmacológico , Ferida Cirúrgica/patologia , Colágeno/metabolismo , Cicatriz/patologia , Cicatriz/tratamento farmacológico
3.
EFORT Open Rev ; 8(10): 748-758, 2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-37787477

RESUMO

Purpose: The goal of this study was to review available literature on periprosthetic shoulder fractures to evaluate epidemiology, risk factors and support clinical decision-making regarding diagnostics, preoperative planning, and treatment options. Methods: Two authors cross-checked the PubMed and Web of Science medical databases. The inclusion criteria were as follows: original human studies published in English, with the timeframe not limited, and the following keywords were used: 'periprosthetic shoulder fracture,' 'total shoulder arthroplasty periprosthetic fractures,' 'total shoulder arthroplasty fracture,' and 'total shoulder replacement periprosthetic fracture.' Seventy articles were included in the review. All articles were retrieved using the aforementioned criteria. Results: The fracture rate associated with total shoulder arthroplasty varied between 0 and 47.6%. Risk factors for periprosthetic fractures were female gender, body mass index < 25 kg/m2, smoking, rheumatoid arthritis, and Parkinson's disease. The most commonly used classification is the Wright and Coefield classification. Periprosthetic fractures can be treated both, conservatively and operatively. Conclusion: Periprosthetic fracture frequency after shoulder arthroplasty ranges from 0 to 47.6%. The most common location of the fracture is the humerus and most commonly occurs intraoperatively. The most important factor influencing treatment is stem stability. Fractures with stem instability require revision arthroplasty with stem replacement. Fractures with a stable stem depending on the location, displacement and bone stock quality can be treated both conservatively and operatively. For internal fixation plates with cables and screws are most commonly used.

4.
J Bone Joint Surg Am ; 105(22): 1759-1767, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37733911

RESUMO

BACKGROUND: Despite the fact that many synovial fluid biomarkers have found application in the routine diagnosis of periprosthetic joint infection (PJI), this process still remains a challenge for orthopaedic surgeons. To simplify this process, fast point-of-care (POC) tests can be used during ambulatory visits and in operating room conditions. However, before such tests can be routinely used in clinical practice, they require validation. The purpose of the present study was to evaluate the diagnostic accuracy of different fast POC tests for detecting C-reactive protein (CRP) in synovial fluid for the diagnosis of PJI. METHODS: Synovial fluid samples were collected from 120 consecutive patients who underwent revision total joint arthroplasty (TJA). The patients were divided into 2 groups. The first group included 76 patients who underwent revision for reasons other than infection (the aseptic revision TJA [arTJA] group), and the second group included 44 patients who underwent revision because of periprosthetic joint infection (PJI). The diagnosis of infection was made according to the International Consensus Meeting (ICM) 2018 criteria. All patients were operatively treated at a single orthopaedic center from January 2022 to February 2023. Four fast CRP tests with different cutoff values (1 and 3 mg/L, ≥8 mg/L, ≥10 mg/L [cassette], ≥10 mg/L [strip]) were used off-label for synovial fluid testing. Tests were performed on the same synovial fluid samples, and the results of these tests were compared with those obtained with the laboratory method. RESULTS: The cassette test with a minimum cutoff value of ≥8 mg/L demonstrated the best accuracy for the diagnosis of chronic PJI, with a sensitivity and specificity of 90.9% and 90.8%, respectively. For the cassette test with a cutoff value of >3 mg/L, the sensitivity and specificity were 68.2% and 77.6%, respectively. For the tests with a minimum cutoff value of ≥10 mg/L, the sensitivity and specificity were 77.3% and 94.7%, respectively, for the cassette test and 77.3% and 96.1%, respectively, for the strip test. The laboratory method with the statistically calculated threshold (2.7 mg/L) revealed the highest AUC (area under the receiver operating characteristic curve) value (0.95), with 90.9% sensitivity and 94.7% specificity. CONCLUSIONS: The cassette POC test with the minimum cutoff value of ≥8 mg/L had very good accuracy for the diagnosis of chronic PJI. This test had comparable sensitivity and slightly lower specificity in comparison with the laboratory method with the calculated threshold of 2.7 mg/L. LEVEL OF EVIDENCE: Diagnostic Level III . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Artroplastia do Joelho , Infecções Relacionadas à Prótese , Humanos , Proteína C-Reativa/análise , Artroplastia do Joelho/efeitos adversos , Líquido Sinovial/química , Infecções Relacionadas à Prótese/etiologia , Sensibilidade e Especificidade , Biomarcadores , Artroplastia de Quadril/efeitos adversos , Artrite Infecciosa/cirurgia
5.
World J Orthop ; 14(6): 387-398, 2023 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-37377994

RESUMO

BACKGROUND: Artificial intelligence and deep learning have shown promising results in medical imaging and interpreting radiographs. Moreover, medical community shows a gaining interest in automating routine diagnostics issues and orthopedic measurements. AIM: To verify the accuracy of automated patellar height assessment using deep learning-based bone segmentation and detection approach on high resolution radiographs. METHODS: 218 Lateral knee radiographs were included in the analysis. 82 radiographs were utilized for training and 10 other radiographs for validation of a U-Net neural network to achieve required Dice score. 92 other radiographs were used for automatic (U-Net) and manual measurements of the patellar height, quantified by Caton-Deschamps (CD) and Blackburne-Peel (BP) indexes. The detection of required bones regions on high-resolution images was done using a You Only Look Once (YOLO) neural network. The agreement between manual and automatic measurements was calculated using the interclass correlation coefficient (ICC) and the standard error for single measurement (SEM). To check U-Net's generalization the segmentation accuracy on the test set was also calculated. RESULTS: Proximal tibia and patella was segmented with accuracy 95.9% (Dice score) by U-Net neural network on lateral knee subimages automatically detected by the YOLO network (mean Average Precision mAP greater than 0.96). The mean values of CD and BP indexes calculated by orthopedic surgeons (R#1 and R#2) was 0.93 (± 0.19) and 0.89 (± 0.19) for CD and 0.80 (± 0.17) and 0.78 (± 0.17) for BP. Automatic measurements performed by our algorithm for CD and BP indexes were 0.92 (± 0.21) and 0.75 (± 0.19), respectively. Excellent agreement between the orthopedic surgeons' measurements and results of the algorithm has been achieved (ICC > 0.75, SEM < 0.014). CONCLUSION: Automatic patellar height assessment can be achieved on high-resolution radiographs with the required accuracy. Determining patellar end-points and the joint line-fitting to the proximal tibia joint surface allows for accurate CD and BP index calculations. The obtained results indicate that this approach can be valuable tool in a medical practice.

6.
Clin Orthop Relat Res ; 481(1): 120-129, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-35944072

RESUMO

BACKGROUND: D-lactic acid is a specific marker produced almost exclusively by bacterial species; thus, the appearance of this marker in synovial fluid may indicate periprosthetic joint infection (PJI). Recently, studies have investigated the accuracy of enzyme-linked laboratory tests that detect D-lactic acid in synovial fluid to diagnose PJI. However, to our knowledge, no studies have determined the usefulness of rapid strip tests that detect D-lactic acid in synovial fluid in the diagnosis of PJI. QUESTIONS/PURPOSES: (1) What is the best cutoff value for the rapid D-lactic acid strip test for diagnosing PJI? (2) What are the diagnostic accuracies (sensitivity, specificity, positive predictive value [PPV], and negative predictive value [NPV]) of the rapid D-lactic acid strip test and two different rapid leukocyte esterase (LE) strip tests? METHODS: This prospective study enrolled 157 patients who underwent revision THA or TKA from May 2021 to February 2022 at a single orthopaedic center. Seventy percent (110 of 157) were eligible for analysis; 10% of these patients (15 of 157) were excluded based on the exclusion criteria (causes of revisions and additional comorbidities that may interfere with the results), and 20% (32 of 157) of the synovial fluid samples could not be tested (dry taps and blood-contaminated samples that could not be centrifuged). We performed the following off-label diagnostic tests on synovial fluid samples collected from all patients: the D-lactic acid strip test (QuantiQuick TM , BioAssay System), two different LE strip tests (10 EA from ARKRAY and BM 10 from BioMaxima). Differently colored strips were marked with symbols (from [-] to [++++] for D-lactic acid and from [-] to [+++] for LE tests) according to the manufacturers' instructions. For the LE tests, results were different for (++), which corresponds to a minimal value of 250 leu/mL for 10 EA and 125 leu/mL for BM 10 tests. The diagnostic standard for the presence or absence of PJI in this study was the International Consensus Meeting (ICM) 2018 criteria; based on these criteria (without the application of an LE test as a minor criterion), all patients were assessed and divided into two groups. Patients who did not meet the criteria for PJI and underwent revision for aseptic loosening, implant malposition, instability, or implant damage were included in the aseptic revision total joint arthroplasty group (68 patients). Patients with a fistula penetrating the joint, those with two positive culture results of the same pathogen, or those with ≥ 6 points according to ICM 2018 minor criteria were enrolled in the PJI group (42 patients). To ascertain the best cutoff value for the rapid D-lactic acid and both LE strip tests for diagnosing PJI, we used collected results, generated a receiver operating characteristic curve, and calculated the Youden index. To determine the accuracies of the diagnostic tests, we calculated their sensitivities, specificities, PPVs, and NPVs against the diagnostic standard (the ICM 2018 criteria). RESULTS: The best cutoff value for D-lactic acid was 22.5 mg/L, which corresponded to a reading of (+) on the test strip. For D-lactic acid, in the diagnosis of PJI, the sensitivity was 83% (95% confidence interval [CI] 68% to 92%) and specificity was 100% (95% CI 93% to 100%). For both LE strip tests, the best cutoff value was the same as that proposed in the ICM 2018 criteria. For LE (10 EA), the sensitivity was 81% (95% CI 66% to 91%) and specificity was 99% (95% CI 91% to 100%); for LE (BM 10), sensitivity was 81% (95% CI 65% to 91%) and specificity was 97% (95% CI 89% to 100%). CONCLUSION: A rapid off-label D-lactic acid strip test is valuable for diagnosing PJI. The results of this study indicate very good accuracy with comparable sensitivity and specificity for both LE strip tests. The usefulness of the test in a group of patients with chronic inflammatory diseases and the reproducibility of the reading by different researchers were not analyzed in this study and require further investigations. Before a rapid D-lactic strip test is routinely used for diagnosing PJI, multicenter studies on a larger group of patients should be conducted.Level of Evidence Level II, diagnostic study.


Assuntos
Artrite Infecciosa , Infecções Relacionadas à Prótese , Humanos , Biomarcadores/análise , Líquido Sinovial/química , Estudos Prospectivos , Ácido Láctico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Artrite Infecciosa/diagnóstico , Infecções Relacionadas à Prótese/microbiologia
7.
J Clin Med ; 11(19)2022 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-36233820

RESUMO

Aims: Total knee arthroplasty in patients with fixed valgus deformity is a demanding procedure. The aim of this study was to compare the clinical results of using the lateral approach [LA] versus the medial approach [MA] in the treatment of fixed valgus knee deformities. Methods: This single-center study compared the results of 143 consecutive patients with fixed valgus deformity (mean 21.55° valgus, mean age 68.2 years) undergoing LA Total Knee Arthroplasty [TKA] to 50 patients (mean 16.58° valgus, mean age 67.2 years) undergoing MA TKA. The mean follow-up period was 5.1 years (2−10 years). Data was collected from operative notes, routine postoperative visits, and radiological findings. Apart from a radiological evaluation, patients were clinically assessed both pre- and postoperatively using the Knee Society Score [KSS]. Descriptive statistics together with the Kolmogorov-Smirnov test, the Student's t-test for independent samples, and the Mann-Whitney U test were used. The level of significance in this study was α = 0.05. Results: In the LA group, the KSS Knee was significantly higher than in the MA group [85.31 vs. 77.42, respectively, p-value < 0.001]. The difference was also in the KSS total but with no statistical significance [155.17 vs. 149.22, p-value 0.087]. The surgery time in the LA group was shorter than in the MA group [81 vs. 91 min, respectively, p-value­0.002]. The complication rate after surgery was higher in the MA group than in the LA group (14% vs. 9%, respectively). Conclusions: The lateral approach is a good alternative to the standard medial parapatellar approach in the treatment of fixed valgus knee deformities. A higher postoperative KSS Knee, shorter surgery time, and similar complication rate make the lateral approach a valuable option for treating patients with osteoarthritis and fixed valgus knee deformity.

8.
J Fungi (Basel) ; 8(8)2022 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-36012786

RESUMO

BACKGROUND: The aim of this study was to analyze the treatment results of fungal periprosthetic joint infections (PJI) caused by Candida species from a single orthopedic center and to compare them with reports from other institutions. METHODS: Eight patients operated on from January 2014 to December 2021 met the inclusion criteria and were analyzed in terms of clinical outcomes. A systematic review of the literature identified 153 patients with Candida PJIs extracted from 12 studies according to the PRISMA (Preferred Reporting Item for Systematic Reviews and Meta-Analyses) guidelines. RESULTS: The success rate of the treatment in the case series was 50%. The most frequent pathogens were Candida albicans (three cases; 37.5%) and Candida parapsilosis (three cases; 37.5%). In one patient (12.5%), bacterial co-infection was noted, and in five patients (62.5%) significant risk factors of PJI were confirmed. The overall success rate on the basis of data collected for systematic review was 65.5%. A sub-analysis of 127 patients revealed statistically significant differences (p = 0.02) with a higher success rate for the knees (77.6%) than for the hips (58%). In 10 studies the analysis of risk factors was performed and among 106 patients in 77 (72.6%) comorbidities predispose to fungal PJI were confirmed. Bacterial co-infection was noted in 84 patients (54.9%). In 93 patients (60.7%) Candida albicans was the culprit pathogen, and in 39 patients (25.5%) Candida parapsilosis was the culprit pathogen. Based on these two most frequent Candida species causing PJI, the success rate of the treatment was statistically different (p = 0.03), and was 60.3% and 83.3%, respectively. The two-stage strategy was more favorable for patients with Candida parapsilosis infections (94.4% success rate) than the one-stage protocol (50% success rate; p = 0.02); as well as in comparison to the two-stage treatment of Candida albicans (65% success rate; p = 0.04). CONCLUSIONS: The analysis of the literature showed no differences in the overall success rate between one- and two-stage surgical strategies for all Candida species, but differed significantly comparing the two most frequent strains and concerning PJI localization. The frequent presence of bacterial co-infections makes it necessary to consider the additional administration of antibiotics in the case of fungal PJI.

9.
PLoS One ; 17(6): e0269164, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35657800

RESUMO

The coronavirus disease (COVID-19) has significantly affected society, especially healthcare systems worldwide. The aim of this retrospective study is to evaluate the impact of the COVID-19 pandemic on orthopaedic and trauma healthcare at the largest university hospital in the Czech Republic. The evaluated periods were in accordance with three waves of the disease and three respective lockdowns. To correlate the results, we evaluated the number of patients (inpatients and outpatients) treated in the same period in the last 3 years before the pandemic. The number of orthopaedic outpatients during the lockdown period decreased by 54.12% (p = 0.002), 42.88% (p <0.001), and 34.53% (p = 0.03) in the first, second, and third lockdowns, respectively. The number of elective surgeries decreased by 69.01% (p <0.001), 87.57% (p <0.001), and 74.89% (p = 0.007) and the number of acute surgeries decreased by 33.15% (p = 0.002), 37.46% (p <0.001), and 27.24% (p = 0.034) in the first, second, and third lockdowns, respectively. This study showed a significant reduction in the healthcare of orthopaedic and trauma patients owing to the COVID-19 pandemic and emphasised the shortcomings of the healthcare system. In our study, there was a reduction in both outpatient (reduction of care by 24-54%) and inpatient care. The elective surgeries were reduced by 69-87% during different lockdown periods compared with the reference period. Based on the results of this study, we can formulate organisational measures to mitigate the impact of the pandemic on orthopaedic healthcare. Organisational procedures created based on acquired data and experience should maximise the bed capacity of the workplace and work efficiency with regard to the safety of medical staff.


Assuntos
COVID-19 , Ortopedia , COVID-19/epidemiologia , Controle de Doenças Transmissíveis , República Tcheca/epidemiologia , Humanos , Pandemias , Estudos Retrospectivos , SARS-CoV-2
10.
Biomed Res Int ; 2022: 8939359, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35419460

RESUMO

The aim of this study is to demonstrate the relationship between the proximal attachment of the coracobrachialis muscle and the short head of the biceps brachii and the distal attachment of the pectoralis minor. Their correlation with the bifurcated coracoid process (CP) will be also assessed. On the basis of these observations, a new classification of structures attached to the coracoid process is proposed. Classical anatomical dissection was performed on one hundred forty-five upper limbs. Three types of relationship between the coracobrachialis muscle and the short head of the biceps brachii were observed in the cadavers. In type I (occurring in 54%), the coracobrachialis and the short head of the biceps brachii created a common junction attached to a single CP. Type II was divided into two subtypes (a and b). Subtype IIa (frequency 10%) was represented by independent proximal attachments of the short head of the biceps brachii and the coracobrachialis muscles to the CP. In subtype IIb (frequency 5%), the coracobrachialis muscle was two-headed (the first head located under the second) and not connected to the short head of the biceps brachii; all heads were attached to a single CP. Type III (frequency 31%) was characterized by a two-headed coracobrachialis muscle, the first head originating from a bifurcated CP laterally to the short head of the biceps brachii and the second medially to this structure. Different variations connected with the mentioned structures could be problematic for surgeons during operations, so detailed knowledge of them could contribute to more efficient procedures.


Assuntos
Processo Coracoide , Músculos Peitorais , Braço , Cadáver , Humanos , Músculo Esquelético
11.
ACS Biomater Sci Eng ; 8(2): 859-870, 2022 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-35020357

RESUMO

This study aimed to evaluate, for the first time, implantable, biodegradable fiducial markers (FMs), which were designed for bimodal, near-infrared fluorescence-based (NIRF) and X-ray-based imaging. The developed FMs had poly(l-lactide-co-caprolactone)-based core-shell structures made of radiopaque (core) and fluorescent (shell) composites with a poly(l-lactide-co-caprolactone) matrix. The approved for human use contrast agents were utilized as fillers. Indocyanine green was applied to the shell material, whereas in the core materials, iohexol and barium sulfate were compared. Moreover, the possibility of tailoring the stability of the properties of the core materials by the addition of hydroxyapatite (HAp) was examined. The performed in situ (porcine tissue) and in vivo experiment (rat model) confirmed that the developed FMs possessed pronounced contrasting properties in NIRF and X-ray imaging. The presence of HAp improved the radiopacity of FMs at the initial state. It was also proved that, in iohexol-containing FMs, the presence of HAp slightly decreased the stability of contrasting properties, while in BaSO4-containing ones, changes were less pronounced. A comprehensive material analysis explaining the differences in the stability of the contrasting properties was also presented. The tissue response around the FMs with composite cores was comparable to that of the FMs with a pristine polymeric core. The developed composite FMs did not cause serious adverse effects on the surrounding tissues even when irradiated in vivo. The developed FMs ensured good visibility for NIRF image-supported tumor surgery and the following X-ray image-guided radiotherapy. Moreover, this study replenishes a scanty report regarding similar biodegradable composite materials with a high potential for application.


Assuntos
Marcadores Fiduciais , Radioterapia Guiada por Imagem , Animais , Durapatita/química , Polímeros , Radioterapia Guiada por Imagem/métodos , Ratos , Suínos , Raios X
12.
Sci Rep ; 12(1): 881, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-35043012

RESUMO

Suction drainage after primary total hip arthroplasties (THA) offers no benefits. Revision hip arthroplasties (RHA) are more demanding procedures and associated with greater blood loss compared to primary cases. There is still a lack of literature regarding the application of drainage in RHA. A total of 40 patients who underwent RHA were included in this prospective study. Simple randomization with an allocation ratio 1:1 was performed. Primary outcomes: total blood loss, hemoglobin drop, joint hematoma size in USG, infection. Secondary outcomes: blood transfusion rate, soft tissue hematomas, C-reactive protein levels, Visual Analogue Scale before and on 3rd day after surgery, Harris Hip Score before and 6 weeks after surgery. An intention to treat analysis was performed, with a 2-year follow up. Statistically significant differences between groups was in blood loss: drainage 1559.78 ml, non-drainage 1058.27 ml, (p = 0.029) and hemoglobin level on 1st day after surgery: drainage 10.58 g/dl, non-drainage 11.61 g/dl (p = 0.0496). In terms of the other analyzed parameters, statistical differences were not found. Our study revealed that the use of suction drainage may lead to higher blood loss in the early postoperative period. Further studies are needed to evaluate our results.


Assuntos
Artroplastia de Quadril
13.
J Clin Med ; 10(24)2021 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-34945254

RESUMO

The aim of this study is to evaluate the course of the treatment and clinical and functional outcomes of femur lengthening in adolescents with congenital disorders by the application of different surgical methods. This retrospective study comprised 35 patients (39 procedures). A total of 11 patients underwent femur lengthening with the use of the intramedullary magnetic nail (IMN) Precise 2 (NuVasive, San Diego, CA, USA), 7 patients (11 procedures) with the use of the monolateral external distractor Modular Rail System (MRS) (Smith and Nephew, Memphis, TN, USA), and 17 with the use of the computer-assisted external fixator Taylor Spatial Frame (TSF) (Smith and Nephew, Memphis, TN, USA). The inclusion criteria were as follows: (1) congenital femoral length deficiency without any axial deformities and (2), independently of the finally applied treatment, the technical possibility of use of each of the analyzed methods. The distraction index did not differ significantly between the groups (p = 0.89). The median lengthening index was the lowest in the IMN group (24.3 d/cm; IQR 21.8-33.1) and statistically different in comparison to the MRS (44.2 d/cm; IQR 42-50.9; p < 0.001) and the TSF groups (48.4 d/cm; IQR 38.6-63.5; p < 0.001). Similarly, the consolidation index in the IMN group (12.9 d/cm; IQR 10.7-21.3) was statistically lower than that in the MRS (32.9 d/cm; IQR 30.2-37.6; p < 0.001) and the TSF (36.9 d/cm; IQR 26.6-51.5; p < 0.001) groups. This study indicates that IMN is a more valuable method of treatment for femoral length discrepancy without axial deformity than MRS and TSF in complication rate and indexes of lengthening and consolidation.

14.
J Clin Med ; 10(21)2021 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-34768444

RESUMO

The aim of this study was to evaluate the bone union, complication rate, clinical and functional outcomes of long-stemmed total knee arthroplasty (TKA) in patients with periprosthetic femoral or tibial shaft fractures and in patients with femoral or tibial shaft fractures with coexisting advanced knee osteoarthritis (OA). This retrospective study comprised 25 patients who underwent surgery due to tibial or femoral shaft fractures: (1) with coexisting severe knee OA or (2) with a periprosthetic fracture requiring implant exchange. In all cases, fracture stabilization was performed intramedullary with the use of long-stemmed implants without the use of additional fixation material (plates, screws, or cerclage). Bone union was achieved in 22/25 patients (88%). One patient required revision with additional plate stabilization due to non-union, and asymptomatic partial bone union was observed in two cases. The group with periprosthetic fractures demonstrated good clinical (mean 73.1 ± 13.3) and moderate functional (mean 59.2 ± 18.8) outcomes in the Knee Society Scoring system (KSS). In the group with shaft fracture and coexisting OA significantly higher clinical (excellent results, mean 84.1 ± 11; p = 0.03) and functional (good results, mean 76.2 ± 20.6; p = 0.04) results were noted. There were no statistically significant differences in terms of range of motion (ROM) or complication rate between these two groups. One-stage TKA with a long-stemmed implant without the use of additional fixation material is an effective method for the treatment of femoral or tibial shaft fractures in patients who require joint replacement. Despite being technically demanding, the approach yields bone union and moderate to excellent clinical and functional outcomes with a relatively low complication rate.

15.
Bone Joint J ; 103-B(8): 1345-1350, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34334049

RESUMO

AIMS: The aim of the study was to compare two methods of calculating pelvic incidence (PI) and pelvic tilt (PT), either by using the femoral heads or acetabular domes to determine the bicoxofemoral axis, in patients with unilateral or bilateral primary hip osteoarthritis (OA). METHODS: PI and PT were measured on standing lateral radiographs of the spine in two groups: 50 patients with unilateral (Group I) and 50 patients with bilateral hip OA (Group II), using the femoral heads or acetabular domes to define the bicoxofemoral axis. Agreement between the methods was determined by intraclass correlation coefficient (ICC) and the standard error of measurement (SEm). The intraobserver reproducibility and interobserver reliability of the two methods were analyzed on 31 radiographs in both groups to calculate ICC and SEm. RESULTS: In both groups, excellent agreement between the two methods was obtained, with ICC of 0.99 and SEm 0.3° for Group I, and ICC 0.99 and SEm 0.4° for Group II. The intraobserver reproducibility was excellent for both methods in both groups, with an ICC of at least 0.97 and SEm not exceeding 0.8°. The study also revealed excellent interobserver reliability for both methods in both groups, with ICC 0.99 and SEm 0.5° or less. CONCLUSION: Either the femoral heads or acetabular domes can be used to define the bicoxofemoral axis on the lateral standing radiographs of the spine for measuring PI and PT in patients with idiopathic unilateral or bilateral hip OA. Cite this article: Bone Joint J 2021;103-B(8):1345-1350.


Assuntos
Cabeça do Fêmur/diagnóstico por imagem , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/fisiopatologia , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/fisiopatologia , Acetábulo/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Postura , Estudos Prospectivos , Adulto Jovem
16.
Artigo em Inglês | MEDLINE | ID: mdl-34444581

RESUMO

The aim of this study was to analyse the effect of the first year of the COVID-19 pandemic on total hip arthroplasty (THA) and total knee arthroplasty (TKA) surgical volume in Poland. A retrospective analysis of data concerning THA and TKA collected by the National Health Fund in Poland in 2019 and in 2020 has been conducted. The number of primary hip or knee arthroplasties in 2020 was around 71% and 67% of the number registered in 2019, respectively. There was also a decline in the volume of revision arthroplasties observed, with 65% and 63% of THA and TKA revisions performed in 2019. The most significant decrease was observed in April and May, and during the second wave of the pandemic in November 2020, with a decline of 87%, 55% and 56%, respectively. The results of this study show the significant impacts that the COVID-19 pandemic had on the volume of elective hip and knee arthroplasties in Poland in 2020. In comparison with 2019, a decrease of around 30% for primary and of 40% for revision arthroplasties was observed. The most significant decline was observed in April and May 2020, and during the second wave of the COVID-19 pandemic in Poland in November 2020.


Assuntos
Artroplastia do Joelho , COVID-19 , Humanos , Pandemias , Polônia/epidemiologia , Estudos Retrospectivos , SARS-CoV-2
17.
Surg Radiol Anat ; 43(5): 735-739, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33590265

RESUMO

The coexistence of different muscular-neurovascular variations is of significant clinical importance. A male cadaver, 76 years old at death, was subjected to routine anatomical dissection; the procedure was performed for research and teaching purposes at the Department of Anatomical Dissection and Donation, Medical University of Lodz. The right forearm and hand were dissected using standard techniques according to a strictly specified protocol. The presence accessory head of the flexor pollicis longus may potentially compress the anterior interosseous nerve. The present case report describes a rare variant of the ulnar head of the pronator teres, characterized by two independent bands (i.e., two proximal attachments). The main band originates from the coronoid process and the second originates from the tendon of the biceps brachii. This type of attachment could potentially affect the compression of the ulnar artery running between the two bands. Additionally, the accessory head of the flexor pollicis longus was observed, which started on the medial epicondyle; its coexistence with a high division median nerve creates a potential pressure site on the anterior interesosseous nerve.


Assuntos
Variação Anatômica , Cotovelo/anormalidades , Nervo Mediano/lesões , Músculo Esquelético/anormalidades , Síndromes de Compressão Nervosa/etiologia , Idoso , Cadáver , Dissecação , Cotovelo/inervação , Humanos , Masculino
18.
Ann Anat ; 235: 151681, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33561523

RESUMO

PURPOSE: Although the plantaris muscle is vestigial in humans, it is far too important to remain omitted. The aim of this study is to provide a comprehensive review of the existing literature focused on plantaris muscle clinical value, grafting usefulness and its morphological variations. Hopefully this study will be of great use for every medical practitioner due to its clarity and conciseness despite such broaden scope of this article. MATERIAL AND METHODS: The article is written based on 100 studies published since 1868 until 2020. During careful selection process 12 papers were dismissed due to their insufficient sample size, wrong methods used or results that were previously discovered. RESULTS: Many aspects concerning the plantaris muscle are already well examined, summarized and described. However this study has shown how much we still do not know and which fields require further investigations. CONCLUSION: The anatomical variations of plantaris muscle morphology may cause mid-portion Achilles tendinopathy, tennis leg syndrome or increase the risk of failure while harvesting the tendons.


Assuntos
Tendão do Calcâneo , Tendinopatia , Comportamento Exploratório , Humanos , Músculo Esquelético , Tamanho da Amostra
19.
Orthopade ; 50(6): 464-470, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32761422

RESUMO

BACKGROUND: This study aimed to evaluate the efficiency of constant dose intravenous administration of tranexamic acid (TXA) in reducing postoperative blood loss, hemoglobin (Hb) concentration, and the number of transfusions in revision hip arthroplasty (RHA). METHODS: The study included 145 consecutive patients who had undergone RHA: a TXA group (75 patients) who received two doses of TXA (1.0 g 15 min before skin incision and 1.0 g during wound closure) and a no-TXA group (70 patients). Percentage blood loss and quantitative blood loss were calculated. RESULTS: The percentage blood loss (23.82 ± 10.6% vs. 39.17 ± 15.1%; P < 0.001), Hb drop (2.9 ± 1.14 g/dL vs. 4.22 ± 1.4 g/dL; P < 0.001), and total blood loss (1030 ± 477 mL vs. 1736 ± 761 mL; P < 0.001) were significantly lower in the TXA group than in the no-TXA group on postoperative day 1. Percentage blood loss (37.5 ± 10.4% vs. 43.1 ± 12.5%; P < 0.01), Hb drop (4.64 ± 1.5 g/dL vs. 5.22 ± 1.6 g/dL; P < 0.01) and total blood loss (1639 ± 543 mL vs. 1908 ± 681 mL; P = 0.02) were significantly lower in the TXA group than in the no-TXA group on the 5th postoperative day. The blood transfusion requirements were lower in the TXA group than those in the no-TXA group (30.7% vs. 71.4% of patients; P < 0.001), with a lower transfusion per patient ratio of 0.55 in the TXA group and 1.4 in the no-TXA group. No postoperative complications were associated with TXA administration, including deep-vein thrombosis and pulmonary embolism. CONCLUSION: Administration of TXA is an effective method to reduce perioperative blood loss, Hb drop and the number of transfusions in RHA.


Assuntos
Antifibrinolíticos , Artroplastia de Quadril , Ácido Tranexâmico , Administração Intravenosa , Perda Sanguínea Cirúrgica/prevenção & controle , Humanos , Hemorragia Pós-Operatória/prevenção & controle
20.
Bone Joint J ; 103-B(1): 46-55, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33380202

RESUMO

AIMS: Calprotectin (CLP) is produced in neutrophils and monocytes and released into body fluids as a result of inflammation or infection. The aim of this study was to evaluate the utility of blood and synovial CLP in the diagnosis of chronic periprosthetic joint infection (PJI). METHODS: Blood and synovial fluid samples were collected prospectively from 195 patients undergoing primary or revision hip and knee arthroplasty. Patients were divided into five groups: 1) primary total hip and knee arthroplasty performed due to idiopathic osteoarthritis (OA; n = 60); 2) revision hip and knee arthroplasty performed due to aseptic failure of the implant (AR-TJR; n = 40); 3) patients with a confirmed diagnosis of chronic PJI awaiting surgery (n = 45); 4) patients who have finished the first stage of the PJI treatment with the use of cemented spacer and were qualified for replantation procedure (SR-TJR; n = 25), and 5) patients with rheumatoid arthritis undergoing primary total hip and knee arthroplasty (RA; n = 25). CLP concentrations were measured quantitatively in the blood and synovial fluid using an immunoturbidimetric assay. Additionally, blood and synovial CRP, blood interleukin-6 (IL-6), and ESR were measured, and a leucocyte esterase (LE) strip test was performed. RESULTS: Patients with PJI had higher CLP concentrations than those undergoing aseptic revision in blood (median PJI 2.14 mg/l (interquartile range (IQR) 1.37 to 3.56) vs AR-TJR 0.66 mg/l (IQR 0.3 to 0.83); p < 0.001) and synovial fluid samples (median PJI 20.46 mg/l (IQR 14.3 to 22.36) vs AR-TJR 0.7 mg/l (IQR 0.41 to 0.95); p < 0.001). With a cut-off value of 1.0 mg/l, blood CLP showed a sensitivity, specificity, positive predictive value, and negative predictive value of 93.3%, 87.5%, 89.4%, and 92.1%, respectively. For synovial fluid with a cut-off value of 1.5 mg/l, these were 95.6%, 95%, 95.5%, and 95%, respectively. CONCLUSION: This small study suggests that synovial and blood CLP are useful markers in chronic PJI diagnosis with similar or higher sensitivity and specificity than routinely used markers such as CRP, ESR, IL-6, and LE. CLP was not useful to differentiate patients with PJI from those with rheumatoid arthritis. Cite this article: Bone Joint J 2021;103-B(1):46-55.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Biomarcadores/metabolismo , Complexo Antígeno L1 Leucocitário/metabolismo , Infecções Relacionadas à Prótese/diagnóstico , Líquido Sinovial/química , Idoso , Sedimentação Sanguínea , Proteína C-Reativa/metabolismo , Doença Crônica , Feminino , Humanos , Interleucina-6/sangue , Masculino , Estudos Prospectivos , Infecções Relacionadas à Prótese/metabolismo , Reoperação , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...