Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Laryngoscope ; 128(5): 1230-1237, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28833232

RESUMO

OBJECTIVES: Adenotonsillectomy (AT) markedly improves but does not necessarily normalize polysomnographic findings in children with adenotonsillar hypertrophy and related sleep-disordered breathing (SDB). Adenotonsillectomy efficacy should be evaluated by follow-up polysomnography (PSG), but this method may underestimate persistent respiratory effort (RE). Mandibular movement (MMas) monitoring is an innovative measurement that readily identifies RE during upper airway obstruction. We hypothesized that MMas indices would decrease in parallel of PSG indices and that children with persistent RE more reliably could be identified with MMas. METHODS: Twenty-five children (3-12 years of age) with SDB were enrolled in this individual prospective-cohort study. Polysomnography was supplemented with a midsagittal movement magnetic sensor that measured MMas during each respiratory cycle before and > 3 months after AT. RESULTS: Adenotonsillectomy significantly improved PSG indices, except for RE-related arousals (RERA). Mandibular movement index changes after AT significantly were correlated with corresponding decreases in sleep apnea-hypopnea index (AHI) and O2 desaturation index (ODI) (Spearman's rho = 0.978 and 0.922, respectively), whereas changes in MMas duration significantly were associated with both RERA duration (rho = 0.475, P = 0.017) and index (rho = 0.564, P = 0.003). Conditional multivariate analysis showed that both AHI and RERA significantly contributed to the variance of MMas index after AT (P = 0.0003 and 0.0005, respectively), whereas MMas duration consistently was related to the duration of RERA regardless of AT. CONCLUSION: Adenotonsillectomy significantly reduced AHI. However, persistent RERA were apparent in a significant proportion of children, and this was reflected by the remaining abnormal MMas pattern. Follow-up of children after AT can be recommended and readily achieved by monitoring MMas to identify persistent RE. LEVEL OF EVIDENCE: 4. Laryngoscope, 128:1230-1237, 2018.


Assuntos
Adenoidectomia , Síndromes da Apneia do Sono/fisiopatologia , Síndromes da Apneia do Sono/cirurgia , Tonsilectomia , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Polissonografia
2.
Respir Res ; 18(1): 66, 2017 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-28427400

RESUMO

BACKGROUND: The patterns of mandibular movements (MM) during sleep can be used to identify increased respiratory effort periodic large-amplitude MM (LPM), and cortical arousals associated with "sharp" large-amplitude MM (SPM). We hypothesized that Cheyne Stokes breathing (CSB) may be identified by periodic abnormal MM patterns. The present study aims to evaluate prospectively the concordance between CSB detected by periodic MM and polysomnography (PSG) as gold-standard. The present study aims to evaluate prospectively the concordance between CSB detected by periodic MM and polysomnography (PSG) as gold-standard. METHODS: In 573 consecutive patients attending an in-laboratory PSG for suspected sleep disordered breathing (SDB), MM signals were acquired using magnetometry and scored manually while blinded from the PSG signal. Data analysis aimed to verify the concordance between the CSB identified by PSG and the presence of LPM or SPM. The data were randomly divided into training and validation sets (985 5-min segments/set) and concordance was evaluated using 2 classification models. RESULTS: In PSG, 22 patients (mean age ± SD: 65.9 ± 15.0 with a sex ratio M/F of 17/5) had CSB (mean central apnea hourly indice ± SD: 17.5 ± 6.2) from a total of 573 patients with suspected SDB. When tested on independent subset, the classification of CSB based on LPM and SPM is highly accurate (Balanced-accuracy = 0.922, sensitivity = 0.922, specificity = 0.921 and error-rate = 0.078). Logistic models based odds-ratios for CSB in presence of SPM or LPM were 172.43 (95% CI: 88.23-365.04; p < 0.001) and 186.79 (95% CI: 100.48-379.93; p < 0.001), respectively. CONCLUSION: CSB in patients with sleep disordered breathing could be accurately identified by a simple magnetometer device recording mandibular movements.


Assuntos
Respiração de Cheyne-Stokes/diagnóstico , Diagnóstico por Computador/métodos , Mandíbula/fisiopatologia , Oscilometria/métodos , Polissonografia/métodos , Síndromes da Apneia do Sono/diagnóstico , Idoso , Respiração de Cheyne-Stokes/fisiopatologia , Feminino , Humanos , Aprendizado de Máquina , Masculino , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Síndromes da Apneia do Sono/fisiopatologia
3.
Respirology ; 22(3): 567-574, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28225162

RESUMO

BACKGROUND AND OBJECTIVE: Mandibular movements (MMs) and position during sleep reflect respiratory efforts related to increases in upper airway resistance and micro-arousals. The study objective was to assess whether MM identifies sleep-disordered breathing (SDB) in patients with moderate to high pre-test probability. METHODS: This was a prospective study of 87 consecutive patients referred for an in-laboratory sleep test. Magnetometer-derived MM signals were incorporated into standard polysomnography (PSG). Respiratory events detected with MM analysis were compared with PSG for respiratory disturbance index (RDI) with a blinded scoring. All records were scored manually according to American Academy of Sleep Medicine rules. Primary outcome was to rule-in obstructive sleep apnoea syndrome (OSAS) defined as RDI cut-off value ≥5 or 15/h total sleep time (TST). RESULTS: High concordance emerged between MM and PSG-derived RDI with high temporal coincidence between events (R2 = 0.906; P < 0.001). The mean diagnostic accuracy of MM for OSAS using RDI MM cut-off values of 5.9 and 13.5 was 0.935 (0.86-0.97) and 0.913 (0.84-0.95), with a mean positive likelihood ratio (LLR+) of 3.73 (2.7-20.4) and 8.46 (2.3-31.5), respectively. Receiver operating characteristic (ROC) curves at PSG cut-off values of 5 and 15/h TST had areas under the curve (AUC) of 0.96 (95% CI: 0.89-0.99) and 0.97 (95% CI: 0.91-0.99) (P < 0.001), respectively. MM analysis accurately identified SDB at different levels of severity. CONCLUSION: RDI assessed by MM is highly concordant with PSG, suggesting a role of ambulatory MM recordings to screen for SDB in patients with moderate to high pre-test probability.


Assuntos
Mandíbula/fisiopatologia , Movimento , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/fisiopatologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Feminino , Humanos , Magnetometria , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial , Polissonografia , Estudos Prospectivos , Curva ROC , Índice de Gravidade de Doença , Sono/fisiologia , Adulto Jovem
4.
Respir Physiol Neurobiol ; 228: 1-8, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26956743

RESUMO

Membrane conductance (Dm) and capillary lung volume (Vc) derived from NO and CO lung transfer measurements in humans depend on the blood conductance (θ) values of both gases. Many θ values have been proposed in the literature. In the present study, measurements of CO and NO transfer while breathing 15% or 21% O2 allowed the estimation of θNO and the calculation of the optimal equation relating 1/θCO to pulmonary capillary oxygen pressure (PcapO2). In 10 healthy subjects, the mean calculated θNO value was similar to the θNO value previously reported in the literature (4.5mmHgmin(-1)) provided that one among three θCO equations from the literature was chosen. Setting 1/θCO=a·PcapO2+b, optimal values of a and b could be chosen using two methods: 1) by minimizing the difference between Dm/Vc ratios for any PcapO2, 2) by establishing a linear equation relating a and b. Using these methods, we are proposing the equation 1/θCO=0.0062·PcapO2+1.16, which is similar to two equations previously reported in the literature. With this set of θ values, DmCO reached the morphometric range.


Assuntos
Monóxido de Carbono/metabolismo , Hemoglobinas/metabolismo , Pulmão/metabolismo , Modelos Cardiovasculares , Óxido Nítrico/metabolismo , Troca Gasosa Pulmonar , Adulto , Idoso , Capilares/metabolismo , Monóxido de Carbono/sangue , Feminino , Humanos , Modelos Lineares , Pulmão/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Óxido Nítrico/sangue , Oxigênio/metabolismo , Pressão , Capacidade de Difusão Pulmonar , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...