Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
2.
Artigo em Inglês | MEDLINE | ID: mdl-26736257

RESUMO

The fractal characteristics of heart rate variability are usually assessed by estimating short- and long-term scale coefficients, α1 and α2, by detrended fluctuation analysis. Recently we extended this approach introducing a temporal spectrum of scale coefficients, α(τ), that describes the deviations of self-similarity from the bi-fractal model at each scale τ. Until now relatively short recordings were considered and α(τ) was characterized only for scales τ<;100 s. Aim of this work is to describe α(τ) of cardiovascular signals extending the range τ by an order of magnitude with respect to previous studies. We considered 2-hour recordings of systolic and diastolic blood pressure (SBP and DBP) and of pulse interval (PI) in 68 volunteers (26 males, 42 females) sitting at rest. The α(τ) spectra were estimated for 5s ≤τ ≤1000s and compared. We found important differences between α(τ) of SBP, DBP and PI. In particular, α(τ) of PI was lower than α(τ) of SBP at all the scales τ, with a relative maximum at τ =26 s and a minimum at τ =300 s that were completely missing in α(τ) of DBP. Significant differences were also found between α(τ) of males and females, probably linked to gender differences in the cardiovascular autonomic tone.


Assuntos
Pressão Sanguínea/fisiologia , Frequência Cardíaca/fisiologia , Adulto , Fenômenos Fisiológicos Cardiovasculares , Feminino , Voluntários Saudáveis , Humanos , Masculino , Caracteres Sexuais , Adulto Jovem
5.
Hypertension ; 57(2): 180-5, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21199997

RESUMO

Sodium sensitivity is an important cardiovascular risk factor for which a diagnosis requires a time-consuming protocol, the implementation of which is often challenging for patients and physicians. Our aim was to assess the reliability of an easier approach based on data from 24-hour ambulatory blood pressure monitoring performed in hypertensive subjects during daily-life conditions and habitual diet. We enrolled 46 mild to moderate hypertensive subjects who underwent 24-hour ambulatory blood pressure monitoring during usual sodium intake. Patients were divided into 3 classes of sodium sensitivity risk on the basis of ambulatory blood pressure monitoring data: low risk if dippers and a 24-hour heart rate ≤ 70 bpm; high risk if nondippers and a 24-hour heart rate of > 70 bpm; intermediate risk with the remaining combinations (dippers with heart rate > 70 bpm or nondippers with heart rate ≤ 70 bpm). Then patients underwent a traditional sodium sensitivity test for the dichotomous classification as sodium sensitive or sodium resistant and for evaluating the sodium sensitivity index. Prevalence of sodium-sensitive patients and mean value of sodium sensitivity index were calculated in the 3 risk classes. The sodium sensitivity index markedly and significantly increased from the low-risk to the high-risk class, being equal to 19.9 ± 14.4, 37.8 ± 8.3, and 68.3 ± 17.0 mm Hg/(mol/day) in the low-risk, intermediate-risk, and high-risk classes, respectively (M ± SEM). Also, the prevalence of sodium-sensitive patients increased significantly from the low-risk class (25%) to the intermediate-risk (40%) and high-risk (70%) classes. Thus, performance of 24-hour ambulatory blood pressure monitoring in daily-life conditions and habitual diet may give useful information on the sodium sensitivity condition of hypertensive subjects in an easier manner than with the traditional sodium sensitivity test approach.


Assuntos
Monitorização Ambulatorial da Pressão Arterial/métodos , Pressão Sanguínea/efeitos dos fármacos , Hipertensão/fisiopatologia , Cloreto de Sódio na Dieta/administração & dosagem , Adulto , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Hipertensão/diagnóstico , Hipertensão/etiologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade
6.
G Ital Cardiol (Rome) ; 8(2): 107-14, 2007 Feb.
Artigo em Italiano | MEDLINE | ID: mdl-17402355

RESUMO

Healthcare costs for heart failure are increasing. The need for a better care, however, has to be matched with a policy of cost containment. A way to improve the cost-effectiveness of heart failure care is the disease management approach, in which therapy, education and follow-up are tailored for each patient by a multidisciplinary team. Such a complex intervention can be facilitated by the use of telemedicine, which allows the remote control of considerable amounts of clinical data. In Italy, a few studies with telemedicine have been reported. A recent development in this field is represented by the ICAROS project (Integrated Care vs Conventional Intervention in Cardiac Failure Patients: Randomized Open Label Study), whose aim is to improve the clinical and psychological care of heart failure patients employing advanced wireless telecommunication technology. So far, we randomized 60 patients: 30 in usual ambulatory care, 30 in an intensive treatment group. The latter patients were instructed to use a portable computer to get in touch daily with the heart failure clinic and receive feedback instruction for the management of drug therapy and daily problems. At the first year of follow-up, the treatment group showed good compliance to drug prescriptions, and could easily handle the portable computer. The preliminary results of this ongoing study support the feasibility and appropriateness of new technologies for the management of heart failure, even in elderly patients in whom a limited expertise with these appliances could have been anticipated.


Assuntos
Gerenciamento Clínico , Insuficiência Cardíaca/terapia , Telemedicina , Idoso , Assistência Ambulatorial , Computadores de Mão/estatística & dados numéricos , Cuidados Críticos , Estudos de Viabilidade , Feminino , Seguimentos , Insuficiência Cardíaca/psicologia , Serviços de Assistência Domiciliar , Humanos , Itália , Masculino , Microcomputadores/estatística & dados numéricos , Pessoa de Meia-Idade , Cooperação do Paciente , Inquéritos e Questionários , Fatores de Tempo
7.
Chest ; 130(5): 1362-8, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17099011

RESUMO

BACKGROUND: Patients with obstructive sleep apnea (OSA) are characterized by deranged cardiovascular variability, a well-established marker of cardiovascular risk. While long-term treatment with continuous positive airway pressure leads to a significant improvement of cardiovascular variability, little is known of the possibility of achieving the same results with other therapeutic approaches. The aim of our study was to investigate the responses of autonomic indexes of neural cardiac control to another type of OSA treatment based on an oral jaw-positioning appliance. METHODS: In 10 otherwise healthy subjects with OSA (OSA+) and in 10 subjects without OSA (OSA-) we measured heart rate, BP, and indices of autonomic cardiac regulation derived from time-domain and spectral analysis of R-R interval (RRI), before and after 3 months of treatment with the oral device. High-frequency (HF) power of RRI was taken as an index of parasympathetic cardiac modulation, and the ratio between low-frequency (LF) and HF RRI powers as an indirect marker of the balance between sympathetic and parasympathetic cardiac modulation. RESULTS: At baseline, in comparison with OSA- subjects, OSA+ subjects displayed a significantly lower RRI variance (p < 0.02) and reduced HF RRI powers (p < 0.001). After 3 months of treatment with the oral device, the OSA+ group showed a marked reduction in apnea-hypopnea index (p < 0.001), a lengthening in RRI and a significant increase in its variance (p < 0,02), an increased HF RRI power (from 134 +/- 26 to 502 +/- 48 ms2, p < 0.001), and a reduction in LF/HF RRI power ratio (from 3.11 +/- 0.8 to 1.5 +/- 0.5). As a result of these changes, after the 3-month treatment there were no more significant differences between the two groups in these parameters. In both OSA+ and OSA- groups, body weight, heart rate, and BP did not change over time. CONCLUSIONS: Three months of treatment with a specific oral jaw-positioning appliance improves cardiac autonomic modulation in otherwise healthy patients with OSA of mild degree.


Assuntos
Sistema Nervoso Autônomo/fisiologia , Coração/fisiologia , Arcada Osseodentária/fisiologia , Placas Oclusais , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Adulto , Pressão Sanguínea/fisiologia , Estudos de Casos e Controles , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Pressão Positiva Contínua nas Vias Aéreas/métodos , Pressão Positiva Contínua nas Vias Aéreas/estatística & dados numéricos , Oclusão Dentária , Eletrocardiografia , Feminino , Coração/inervação , Frequência Cardíaca/fisiologia , Humanos , Arcada Osseodentária/anatomia & histologia , Masculino , Pessoa de Meia-Idade , Sistema Nervoso Parassimpático/fisiologia , Sistema Nervoso Simpático/fisiologia
8.
Acta Biomed ; 76(2): 86-94, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16350553

RESUMO

RATIONALE AND OBJECTIVES: to compare contrast material (CM) administration protocols in non-invasive coronary angiography (CA) using a 16-row multislice CT (16-MSCT). METHODS: 45 patients undergoing CA with 16-MSCT were divided into three CM protocols: group 1 (140 ml@4ml/s), group 2 (140 ml = 60 ml@5ml/s + 80 ml@3ml/s), and group 3 (100 ml@4ml/s). The attenuation at the origin of the coronary vessels was assessed. Three regions of interest were evaluated: 1) ascending aorta (ROI1); 2) descending aorta (ROI2); 3) pulmonary artery (ROI3). The resulting time-density curves generated the average attenuation and the slope of bolus geometry. RESULTS: the attenuation at the origin of the coronary vessels, and the average attenuation of bolus geometry were not significantly different (p > 0.05). The slope of bolus geometry was in ROI1 and ROI2 significantly lower for group 2, in ROI3 significantly lower for group 3 (p < 0.05). CONCLUSION: 100 ml of CM provide the same attenuation in 16-MSCT CA as mono- or multi-phasic 140 ml protocols.


Assuntos
Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos
9.
Hypertension ; 46(6): 1321-6, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16246970

RESUMO

Salt-sensitive hypertensive subjects, as defined by conventional categorical classification, exhibit alterations of autonomic cardiovascular control. The aim of our study was to explore whether, in hypertensive subjects, the degree of autonomic dysfunction and the level of salt sensitivity are correlated even when the latter is only mildly elevated and displays under-threshold values. Salt sensitivity of 34 essential hypertensive subjects was assessed on a continuous basis by the salt sensitivity index after low- and high-sodium diet. Beat-by-beat finger blood pressure was recorded after each diet period. Autonomic cardiovascular control was evaluated by spectral analysis of blood pressure and pulse interval and by assessment of spontaneous baroreflex sensitivity (sequence technique). Salt sensitivity and baroreflex sensitivity showed a negative relationship during low and high sodium intake, starting from low values of the salt sensitivity index. All spectral indexes of pulse interval, except the ratio between low- and high-frequency powers, were inversely related to salt sensitivity index after high sodium intake. In subjects with lower salt sensitivity, baroreflex sensitivity and pulse interval power in the high-frequency band were higher after high sodium intake than after low sodium intake. In contrast, subjects with a higher salt sensitivity index showed lower values of baroreflex sensitivity and pulse interval power in the high-frequency band, uninfluenced by salt intake. Our results provide the first demonstration of an impairment of parasympathetic cardiac control in parallel with the increase in the degree of salt sensitivity, also in subjects who were not ranked as salt-sensitive by the conventional categorical classification.


Assuntos
Sistema Nervoso Autônomo/fisiopatologia , Pressão Sanguínea/efeitos dos fármacos , Sistema Cardiovascular/fisiopatologia , Hipertensão/fisiopatologia , Cloreto de Sódio na Dieta/administração & dosagem , Barorreflexo/efeitos dos fármacos , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema Nervoso Parassimpático/fisiopatologia , Pulso Arterial , Cloreto de Sódio na Dieta/farmacologia
10.
Acta Biomed ; 76(1): 20-7, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16116821

RESUMO

PURPOSE: To evaluate the pitfalls occurring during the virtual colonoscopy examination performed with a protocol designed for screening purposes. MATERIALS AND METHODS: 40 patients underwent a spiral CT for virtual colonoscopic evaluation with the following parameters: collimation 3 mm, feed 6 mm.rot(-1), pitch 2 and increment 1 mm in supine position. Virtual colonography examination was carried out using a dedicated workstation equipped with a software which allows to generate 3D images and virtual endoscopic views. Colon distension, fluid and fecal material were assessed on a 3 point scale. RESULTS: Distension score was 0.50. Left colon and cecum score was 0.32 while in the sigmoid and rectum the score was worse with 0.86. Fluid and fecal residues scores were 0.31 and 0.19 respectively. On almost half of the patients additional scans would be necessary. The main cause of additional scans is suboptimal intestinal preparation and colon distension. CONCLUSION: The use of virtual colonoscopy for screening purposes will be possible through the further technical development and with the optimisation of the protocols, particularly by the improvement of colon cleansing and distension.


Assuntos
Colonografia Tomográfica Computadorizada , Neoplasias Colorretais/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Lesões Pré-Cancerosas/diagnóstico por imagem , Tomografia Computadorizada Espiral , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Brometo de Butilescopolamônio/administração & dosagem , Estudos de Coortes , Pólipos do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/métodos , Colonoscopia , Enema , Feminino , Previsões , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Antagonistas Muscarínicos/administração & dosagem , Parassimpatolíticos/administração & dosagem , Estudos Prospectivos , Software
11.
Radiol Med ; 109(4): 376-84, 2005 Apr.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-15883522

RESUMO

AIM: To assess the influence of pre-set volume-rendering opacity curves (OC) on image quality and to identify which absolute parameters (density of aorta, hepatic parenchyma and portal vein) affect visualization of portal vascular structures (low-contrast structures). MATERIALS AND METHODS: Twenty-two patients underwent a dual-phase spiral CT with the following parameters: collimation 3 mm, pitch 2, increment 1 mm. Three scans were performed: one without contrast medium and the latter two after the injection of contrast material (conventionally identified as ''arterial'' and ''portal''). The images were sent to a workstation running on an NT platform equipped with post-processing software allowing three-dimensional (3D) reconstructions to generate volume-rendered images of the vascular supply to the liver. Correlation between the absolute values of aorta, liver and portal vein density, OC parameters, and image quality were assessed. RESULTS: 3D images generated using pre-set OC obtained a much lower overall quality score than those produced with OC set by the operator. High contrast between the liver and the portal vein, for example during the portal vascular phase, allows wider windows, thus improving image quality. Conversely, the OC in the parenchymal phase scans must have a high gradient in order to better differentiate between the vascular structures and the surrounding hepatic parenchyma. CONCLUSIONS: Image features considered to be of interest by the operator cannot be simplified by the mean of pre-set OC. Due to their strong individual variability automatic 3D algorithms cannot be universally applied: they should be adapted to both image and patient characteristics.


Assuntos
Algoritmos , Imageamento Tridimensional , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia
12.
Radiol Med ; 109(3): 198-207, 2005 Mar.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-15775888

RESUMO

AIM: To investigate the diagnostic accuracy of two different protocols for image evaluation used in multislice computed tomography coronary angiography (MSCT-CA). MATERIALS AND METHODS: Sixty patients with suspected coronary artery disease undergoing conventional coronary angiography (CA) were enrolled for MSCT-CA. All patients underwent 16-row MSCT (Sensation 16, Siemens, Germany) with the following parameters: detector rows 16, collimation 0.75 mm, gantry rotation time 375 ms. Two independent observers assessed the images for significant stenosis using a a protocol with standard projections and a three-dimensional protocol. The diagnostic accuracy for both methods was calculated using quantitative CA as a reference standard. RESULTS: The sensitivity, specificity, negative predictive value and positive predictive value obtained with the conventional projection protocol and with three-dimensional protocol were: 54% and 93%, 97% and 97%, 76% and 86%, 92% and 99%, respectively. CONCLUSIONS: Conventional projections in the assessment of MSCT-CA provide insufficient diagnostic accuracy compared with three-dimensional processing.


Assuntos
Angiografia Coronária/métodos , Processamento de Imagem Assistida por Computador/métodos , Iopamidol/análogos & derivados , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Angiografia Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Imageamento Tridimensional/métodos , Imageamento Tridimensional/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada Espiral/métodos , Tomografia Computadorizada Espiral/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos
13.
Radiol Med ; 110(5-6): 506-22, 2005.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-16437037

RESUMO

With the increasing diffusion of 4-row,16-row and 64-row multislice computed tomography scanners, widespread coronary calcium scoring has become possible in Europe. This relatively easy-to-perform test has a high sensitivity and low specificity for the detection of significant coronary artery stenosis, and may have an important role in the risk stratification for future coronary artery events in selected groups of patients, such as those immediately at risk. This study reviews the techniques available for coronary calcium scoring (electron beam tomography and multislice computed tomography) with their respective protocols, as well as their advantages and disadvantages. The methods for interpreting the results, the potential indications and the clinical applications of the techniques are also described.


Assuntos
Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Calcinose/fisiopatologia , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/prevenção & controle , Humanos
14.
Radiol Med ; 107(5-6): 489-96, 2004.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-15195011

RESUMO

PURPOSE: To compare two different techniques for the administration of the bolus of contrast material (cm) in coronary angiography with multislice CT (MSCT) scanner. MATERIALS AND METHODS: Thirty consecutive patients were divided into two groups. In group 1 contrast material was administered with the monophasic protocol (140 ml of cm at 4 ml/s). In group 2 contrast material was administered with the biphasic protocol (70 ml of cm at 4 ml/s and 70 ml at 3 ml/s). The angiographic scan was performed in both groups with a 16-row MSCT scanner. Three regions of interest were drawn in each scan throughout the data-set in order to measure attenuation: 1) ascending aorta (ROI1); 2) descending aorta (ROI2); 3) pulmonary artery (ROI3). Attenuation was also assessed at the origin of the main coronary arteries. RESULTS: No significant differences of the attenuation values were observed at the origin of the coronary arteries (p>0.05). The attenuation profile of the monophasic protocol showed higher and longer attenuation values than the biphasic protocol. CONCLUSIONS. The biphasic administration of contrast material does not supply significant advantages on the enhancement of the great vessels and the coronary arteries in 16-row MSCT coronary angiography.


Assuntos
Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X , Protocolos Clínicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos
15.
Metabolism ; 52(12): 1597-600, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14669162

RESUMO

Potassium depletion induced by dietary potassium restriction is known to cause sodium retention, while potassium supplementation is known to increase urinary sodium excretion. However, the ability of potassium deficiency to affect mineralocorticoid-induced sodium retention in aldosterone-producing adenoma (APA) subjects has not been extensively investigated, neither in baseline conditions nor when facilitating natriuresis through a physiological manoeuver such as central blood volume expansion. With the aim of testing the hypothesis that potassium supplementation would attenuate the mineralocorticoid-induced sodium retention, in 7 APA patients elevation of serum potassium was obtained by infusion of isosmotic potassium chloride (KCl) at a constant rate of 36 mmol/h for a 2-hour period for 5 consecutive days. The same patients were also submitted to acute central volume expansion by head-out water immersion (WI) associated with either low or normal serum potassium levels. The assessment of natriuresis in baseline condition and during WI was also performed in 10 age-matched control subjects. Central hypervolemia by WI induced a significant natriuretic response in APA hypokalemic subjects; on the other hand, in the same APA subjects giving potassium supplementation, WI-induced urinary sodium excretion was significantly higher (P <.001) than that obtained during WI at normal potassium intake (hypokalemic condition). Blood pressure responses and hormonal profiles were almost superimposable during the 2 WI experiments performed at different serum potassium levels. By confirming that amelioration of hypokalemia attenuates mineralocorticoid-induced sodium retention, this study also suggests that potassium intake may represent an important determinant of mineralocorticoid escape.


Assuntos
Volume Sanguíneo/fisiologia , Hiperaldosteronismo/tratamento farmacológico , Hiperaldosteronismo/fisiopatologia , Natriurese/efeitos dos fármacos , Cloreto de Potássio/uso terapêutico , Adulto , Idoso , Aldosterona/sangue , Fator Natriurético Atrial/sangue , Pressão Sanguínea/fisiologia , Dieta , Suplementos Nutricionais , Feminino , Humanos , Imersão , Masculino , Pessoa de Meia-Idade , Renina/sangue , Sódio/urina
16.
Nephron Physiol ; 94(3): p51-8, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12902616

RESUMO

Our study aimed at elucidating the effects of acute central hypervolemia induced by water immersion (WI) on renal hemodynamics, hormonal responses and on cardiovascular control in hypertensive patients, as well as at evaluating the possible role of the opioidergic system (OS) in determining these effects. Thirteen essential hypertensives were studied for 2 h before and for 2 h during WI. This was done twice, without and with i.v. injection of the OS antagonist naloxone. Before and during WI alone, glomerular filtration rate (GFR), effective renal plasma flow (ERPF), renal vascular resistance (RVR), mean arterial pressure (MAP), pulse interval (PI), spontaneous baroreflex sensitivity (BRS), Low frequency to High frequency (LF/HF) ratio in PI spectra, hematocrit, urinary sodium excretion, plasma renin activity (PRA) and aldosterone (PA) were assessed. Based on their response to WI, hypertensives were subdivided into two groups: ERPF+ (n = 7) in whom WI increased ERPF, and ERPF- (n = 6) in whom WI reduced ERPF. ERPF+ displayed a higher BRS than ERPF- at baseline and during WI. A suppression of PRA and PA and an increase in MAP and urinary sodium excretion were found in both groups. In ERPF+ naloxone caused RVR and MAP to increase during WI and this response was associated with a blockade of the increase in ERPF in this group, while BRS and natriuresis were unchanged. In ERPF- naloxone did not affect WI-induced MAP, ERPF, RVR and BRS changes, while it blunted sodium excretion. Our data provide the first evidence of a differentiate renal hemodynamic response to WI in hypertension; they also suggest that while OS may significantly potentiate the renal vasodilatory response to WI in ERPF+, it does not affect the natriuretic response nor the changes in systemic cardiovascular regulation induced by central hypervolemia.


Assuntos
Hipertensão/fisiopatologia , Rim/fisiopatologia , Naloxona/farmacologia , Antagonistas de Entorpecentes/farmacologia , Adulto , Volume Sanguíneo , Hemodinâmica/efeitos dos fármacos , Humanos , Imersão , Rim/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Fluxo Plasmático Renal Efetivo , Água
17.
Metabolism ; 52(4): 508-13, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12701067

RESUMO

The purpose of the present study was to investigate the possible regulation of plasma fatty acids by an acute isotonic-isooncotic central volume expansion. We measured the levels of nonesterified fatty acids (NEFA) in plasma from 12 essential hypertensive patients subjected to water immersion (WI). Central hypervolemia by WI over 2 hours caused the levels of most NEFA to increase, concomitantly with a marked natriuretic and kaliuretic response. With respect to baseline values, serum insulin levels did not change during WI, while there was a profound suppression of plasma renin activity (PRA) and plasma aldosterone. In addition, when individual NEFA percent increase was expressed as a function of salt-sensitivity index (calculated as the change in mean arterial pressure [MAP] divided by the change in urinary sodium excretion rate), a greater percent increase in stearic acid (r =.72, P <.009), palmitic acid (r =.83, P <.001), and palmitoleic acid (r =.58, P <.048) was found during WI in those hypertensive subjects showing higher salt-sensitivity index. Thus, by demonstrating that an acute isotonic-isooncotic volume expansion may induce a significant increase of most NEFA plasma levels, we suggest that volume expansion per se could be included among the well-recognized risk factors for cardiovascular morbid events.


Assuntos
Volume Sanguíneo/fisiologia , Ácidos Graxos não Esterificados/sangue , Hipertensão/sangue , Cloreto de Sódio , Adulto , Aldosterona/sangue , Creatinina/sangue , Feminino , Humanos , Hipertensão/induzido quimicamente , Imersão/fisiopatologia , Insulina/sangue , Masculino , Pessoa de Meia-Idade , Ácidos Palmíticos/sangue , Renina/sangue , Sódio/urina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...