Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anal Methods ; 16(35): 5982-5989, 2024 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-39162061

RESUMO

The understanding of metabolic alterations triggered by intense exercise can provide a biological basis for the development of new training and recovery methods. One popular way to monitor these changes is the non-invasive analysis of the composition of urine. This work evaluates the use of attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) and multivariate analysis as a rapid and cost-effective way to investigate changes in urine composition after intense exercise. The urine FTIR spectra of 21 volunteers (14 going through aerobic exercise and 7 controls) were measured before and immediately, 2, 5, 11, and 24 h after running 10 km. Principal component analysis (PCA) and partial least squares analysis (PLS) regression were used to investigate the changes in the spectra as a function of the recovery time. PLS models obtained for the prediction of the time points in the exercise group were deemed significant (p < 0.05, rand t-test permutation testing in cross-validation), showing changes in the urine composition after the exercise, reaching a maximum after 11 hours as opposed to the control group which did not show any significant relationship with the recovery time. In a second step, spectra of the protean extract isolated from urines at significant timepoints (before, immediately after, and 11 hours after exercise) were measured. The PCA of the protein spectra showed clear differences in the spectra obtained at the separation between the recovery time points, especially after the end of the exercise, where the protein profile was significantly different from the other times. Results indicate that the technique was able to find differences in the urine after physical exertion and holds strong potential for an easy-to-use and simple screening metabolic evaluation of recovery methods.


Assuntos
Exercício Físico , Humanos , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Exercício Físico/fisiologia , Masculino , Adulto , Feminino , Sistemas Automatizados de Assistência Junto ao Leito , Análise dos Mínimos Quadrados , Urinálise/métodos , Análise de Componente Principal
2.
Talanta ; 243: 123330, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35272153

RESUMO

Up-to-date diagnostics is globally improved by point-of-care testing (POCT) analysis and bedside research works. Development in POCT analysis has been provided mostly by forward-looking engineering technology for biosensing and sensing assessments. Lately, lateral flow assays (LFAs) have attracted a lot of interest as a result of their noteworthy benefits including cost-effectiveness, better portability, being operator friendly and rapid detection. This technique has been employed broadly for monitoring diverse biomarkers linked to ultrasensitive detection of pathogenic bacteria, ecological monitoring, consumer protection, and infectious diseases. LFA analyses established on qualitative and optical outcomes have boosted the objectivity and data efficiency of the assessments. Therefore, developing novel methods with the capability of providing reliable and quantitative information regarding a target analyte in a model and preserving the qualities of LFAs is of great necessity. In this review, the main principles of LFAs, challenges, and prospects for more development in this field in sensing pathogenic bacteria have been summarized. Subsequently, visually-read LFAs improvement to further progressive platforms have been explored by considering the prospects of this very flexible method for ultrasensitive detection of pathogenic bacteria. In addition, novel labeling methodologies, electrochemical and optical transducers are described. Also, recent developments in these detection methods elements in combination with other considered approaches have been highlighted.


Assuntos
Doenças Transmissíveis , Sistemas Automatizados de Assistência Junto ao Leito , Bactérias , Bioensaio , Doenças Transmissíveis/diagnóstico , Humanos , Imunoensaio/métodos , Testes Imediatos
3.
Biosens Bioelectron ; 169: 112599, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-32931990

RESUMO

miRNAs are a large family of non-coding RNAs which play important roles in translational and post-transcriptional regulation of gene expression and biological processes. Abnormal expression of miRNAs is related to the initiation and progression of different diseases which make them be promising candidates for early medical diagnostics. Thus, accurate detection of miRNAs has great significance for disorder diagnosis. Nevertheless, their intrinsic characteristics such as short sequence, low concentration and sequence homology challenge routine techniques. The detection assays need to be extremely sensitive and selective in small value of intricate RNA samples. Biosensor-based strategies have emerged as potential alternatives to conventional methods in miRNA quantification. The surface plasmon resonance (SPR), an optical biosensor, possessing various advantages including excellent reliability, selectivity and reproducibility represents a wide range of applications in real-time monitoring of biomolecular interactions and detection of biological and chemical analytes with label-based or label free form. Various signal amplification methods can overcome the limitation of SPR methods for detection of small molecules, making it suitable for clinical diagnosis. This review discusses main concepts and performance characteristics of SPR biosensor. Mainly, it focuses on newly emerged enhanced SPR biosensors towards high-throughput and ultrasensitive screening of miRNAs using labeling processes with focusing on the future application in biomedical research and clinical diagnosis. Actually, label-based signal amplification strategies of SPR platforms including nanoparticle enhancement, supersandwich assembly, streptavidin/biotin complex, antibody amplification, enzymatic reactions, triplex structure formation and catalytic hairpin assembly are discussed. Finally label free detection of miRNAs and advantages of SPR-based method was presented.


Assuntos
Técnicas Biossensoriais , MicroRNAs , Reprodutibilidade dos Testes , Estreptavidina , Ressonância de Plasmônio de Superfície
4.
J Nucl Med Technol ; 48(1): 81-84, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31604895

RESUMO

131I-metaiodobenzylguanidine (131I-MIBG) is a theranostic agent useful for treatment of neuroendocrine malignancies. In this case, a child with a Curie score of 21 was administered 17.871 GBq (483 mCi) of 131I-MIBG. The elimination half-life progressively increased from 23 h to 77 h during the 11 d that the patient was hospitalized for radiation isolation. Six weeks after the posttherapy scan, a survey with an ion-chamber device yielded readings of 0.3 µSv/h (0.03 mR/h) on contact with spinal regions that had shown increased uptake on the scan. A planar image obtained using the 131I setting and a high-energy collimator did not demonstrate any focal uptake. 123I-MIBG was administered, and the 24-h scan was of diagnostic quality, without degradation from the remaining 131I-MIBG. Additional study is needed on whether the Curie score affects elimination of 131I-MIBG and on whether the period of hospitalized radiation isolation needs to be extended.


Assuntos
Radioisótopos do Iodo/farmacocinética , Radioisótopos do Iodo/uso terapêutico , Tumores Neuroendócrinos/radioterapia , Compostos Radiofarmacêuticos/farmacocinética , Imagem Corporal Total/métodos , Criança , Feminino , Humanos , Radioisótopos do Iodo/urina , Cintilografia/métodos , Compostos Radiofarmacêuticos/uso terapêutico , Compostos Radiofarmacêuticos/urina
5.
Anal Chem ; 90(15): 9093-9100, 2018 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-29939015

RESUMO

Oxidative stress monitoring in the neonatal period supports early outcome prediction and treatment. Glutathione (GSH) is the most abundant antioxidant in most cells and tissues, including whole blood, and its usefulness as a biomarker has been known for decades. To date, the available methods for GSH determination require laborious sample processing and the use of sophisticated laboratory equipment. To the best of our knowledge, no tools suitable for point-of-care (POC) sensing have been reported. Surface-enhanced Raman spectroscopy (SERS), performed in a microvolume capillary measurement cell, is proposed in this study as a robust approach for the quantification of GSH in human whole blood samples. The use of a silver colloid allowed a highly selective signal enhancement for GSH providing analytical enhancement factors of 3 to 4 orders of magnitude. A highly accurate determination of GSH in whole blood samples with recoveries ranging from 99 to 107% and relative standard deviations less than or equal to 18% were achieved by signal normalization with the intensity of an isotopically labeled internal standard. GSH concentrations were retrieved within 4 min using small-volume blood samples (2 µL). The developed procedure was applied to the analysis of blood of 20 healthy adults and 36 newborns, obtaining comparable results between literature and those found by SERS and a reference method. The characteristics of this novel tool are suitable for its implementation in a portable optical sensor device enabling POC testing of oxidative stress levels in newborns.


Assuntos
Glutationa/sangue , Prata/química , Análise Espectral Raman/métodos , Adulto , Humanos , Recém-Nascido , Limite de Detecção , Testes Imediatos , Tamanho da Amostra , Análise Espectral Raman/instrumentação , Propriedades de Superfície
6.
PLoS One ; 12(11): e0186340, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29117181

RESUMO

METHODS: After injecting 25.6 ± 8.8 MBq (0.7 ± 0.2 mCi) of 18F-Fluoro-L-DOPA intravenously, three static PET scans were acquired at 20, 30, and 40 min post injection in 3-D mode on 10 patients (6 male, 4 female) with congenital hyperinsulinism. Regions of interest (ROIs) were drawn over several organs visible in the reconstructed PET/CT images and time activity curves (TACs) were generated. Residence times were calculated using the TAC data. The radiation absorbed dose for the whole body was calculated by entering the residence times in the OLINDA/EXM 1.0 software. RESULTS: The mean residence times for the 18F-Fluoro-L-DOPA in the liver, lungs, kidneys, muscles, and pancreas were 11.54 ± 2.84, 1.25 ± 0.38, 4.65 ± 0.97, 17.13 ± 2.62, and 0.89 ± 0.34 min, respectively. The mean effective dose equivalent for 18F-Fluoro-L-DOPA was 0.40 ± 0.04 mSv/MBq. The CT scan used for attenuation correction delivered an additional radiation dose of 5.7 mSv. The organs receiving the highest radiation absorbed dose from 18F-Fluoro-L-DOPA were the urinary bladder wall (2.76 ± 0.95 mGy/MBq), pancreas (0.87 ± 0.30 mGy/MBq), liver (0.34 ± 0.07 mGy/MBq), and kidneys (0.61 ± 0.11 mGy/MBq). The renal system was the primary route for the radioactivity clearance and excretion. CONCLUSIONS: The estimated radiation dose burden from 18F-Fluoro-L-DOPA is relatively modest to newborns.


Assuntos
Hiperinsulinismo Congênito/diagnóstico por imagem , Levodopa/administração & dosagem , Doses de Radiação , Hiperinsulinismo Congênito/metabolismo , Hiperinsulinismo Congênito/patologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Lactente , Recém-Nascido , Rim/efeitos da radiação , Fígado/efeitos da radiação , Pulmão/efeitos da radiação , Masculino , Músculos/efeitos da radiação , Pâncreas/efeitos da radiação , Tomografia por Emissão de Pósitrons , Radiometria/métodos , Distribuição Tecidual/efeitos da radiação
7.
J Pharm Biomed Anal ; 131: 48-53, 2016 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-27521989

RESUMO

A selective solid-phase extraction was employed for the improvement of the determination of non-steroidal anti-inflammatory drugs (NSAIDs) in continental water and urine samples. Ketoprofen, naproxen, diclofenac, and ibuprofen were selected as target analytes due to they are the most frequently administered and consumed NSAIDs. These compounds were extracted using molecular imprinted polymers and determined by liquid chromatography with diode array (DAD), and tandem-mass spectrometry (MS-MS) detectors. Performance of DAD and MS-MS detectors was evaluated throughout this study. The obtained limits of quantification, after a 50-fold preconcentration solid-phase extraction, varied from 20 to 30µgL-1 for DAD, and from 0.007 to 0.017µgL-1 for MS-MS for both types of sample matrixes. Quantitative recoveries were found for blank-samples spiked at different NSAIDs concentration levels, ranging from 0.05 to 10mgL-1 for urine and from 0.5 to 500µgL-1 for water. The proposed methodology was applied for the determination of NSAID residues in urine of prescribed individuals, and continental waters.


Assuntos
Anti-Inflamatórios não Esteroides/urina , Impressão Molecular/métodos , Polímeros/química , Espectrometria de Massas em Tandem/métodos , Poluentes Químicos da Água/análise , Anti-Inflamatórios não Esteroides/análise , Cromatografia Líquida/métodos , Água
8.
Anal Chim Acta ; 853: 116-126, 2015 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25467453

RESUMO

This review summarizes the different tools and concepts that are commonly applied in air quality monitoring. The monitoring of atmosphere is extremely important as the air quality is an important problem for large communities. Main requirements for analytical devices used for monitoring include a long period of autonomic operation and portability. These instruments, however, are often characterized by poor analytical performance. Monitoring networks are the most common tools used for monitoring, so large-scale monitoring programmes are summarized here. Biomonitoring, as a cheap and convenient alternative to traditional sample collection, is becoming more and more popular, although its main drawback is the lack of standard procedures. Telemonitoring is another approach to air monitoring, which offers some interesting opportunities, such as ease of coverage of large or remote areas, constituting a complementary approach to traditional strategies; however, it requires huge costs.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/métodos , Cromatografia Gasosa , Técnicas Eletroquímicas , Monitoramento Ambiental/instrumentação , Dispositivos Lab-On-A-Chip , Casca de Planta/química , Casca de Planta/metabolismo , Plantas/química , Plantas/metabolismo , Tecnologia de Sensoriamento Remoto
9.
Talanta ; 107: 368-75, 2013 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-23598236

RESUMO

Locally weighted partial least squares regression (LW-PLSR) has been applied to the determination of four clinical parameters in human serum samples (total protein, triglyceride, glucose and urea contents) by Fourier transform infrared (FTIR) spectroscopy. Classical LW-PLSR models were constructed using different spectral regions. For the selection of parameters by LW-PLSR modeling, a multi-parametric study was carried out employing the minimum root-mean square error of cross validation (RMSCV) as objective function. In order to overcome the effect of strong matrix interferences on the predictive accuracy of LW-PLSR models, this work focuses on sample selection. Accordingly, a novel strategy for the development of local models is proposed. It was based on the use of: (i) principal component analysis (PCA) performed on an analyte specific spectral region for identifying most similar sample spectra and (ii) partial least squares regression (PLSR) constructed using the whole spectrum. Results found by using this strategy were compared to those provided by PLSR using the same spectral intervals as for LW-PLSR. Prediction errors found by both, classical and modified LW-PLSR improved those obtained by PLSR. Hence, both proposed approaches were useful for the determination of analytes present in a complex matrix as in the case of human serum samples.


Assuntos
Glicemia/análise , Proteínas Sanguíneas/análise , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Triglicerídeos/sangue , Ureia/sangue , Humanos , Análise dos Mínimos Quadrados
10.
Talanta ; 68(4): 1230-5, 2006 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-18970454

RESUMO

An analytical procedure was developed for the determination of the total amount of sterols in the red alga Asparagopsis armata, globally determined as cholesterol, which is the major sterol contained in red algae. Samples, previously saponified with KOH were preconcentrated on DSC-18 solid phase cartridges (SPE) and eluted with dichloromethane stabilized with beta-amylene. Fourier transform infrared (FTIR) spectrometry was employed for selective detection at 1049cm(-1) with a baseline established between 1000 and 1079cm(-1). The results were compared to those obtained by high performance liquid chromatography (HPLC). The concentration obtained in actual samples from alga was 3.37% (w/w) by FTIR and 3.30% (w/w) by HPLC, showing a good comparability between the two methods.

11.
Talanta ; 66(4): 895-901, 2005 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-18970069

RESUMO

A rapid, sensitive and economic method has been developed for the direct determination of toxic species of arsenic present in fish and mussel samples. As(III), As(V), dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) were determined by hydride generation-atomic fluorescence spectrometry using a series of proportional equations without the need of a chromatographic previous separation. The method is based on the extraction of arsenic species from fish through sonication with HNO(3) 3moll(-1) and 0.1% (m/v) Triton and washing of the solid phase with 0.1% (m/v) EDTA, followed by direct measurement of the corresponding hydrides in four different experimental conditions. The limit of detection of the method was 0.62ngg(-1) for As(III), 2.1ngg(-1) for As(V), 1.8ngg(-1) for MMA and 5.4ngg(-1) for DMA, in all cases expressed in terms of sample dry weight. The mean relative standard deviation values (R.S.D.) in actual sample analysis were: 6.8% for As(III), 10.3% for As(V), 8.5% for MMA and 7.4% for DMA at concentration levels from 0.08mgkg(-1) As(III) to 1.3mgkg(-1) DMA. Recovery studies provided percentages greater than 93% for all species in spiked samples. The analysis of SRM DORM-2 and CRM 627 certified materials evidenced that the method is suitable for the accurate determination of arsenic species in fish.

12.
Talanta ; 67(4): 673-7, 2005 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-18970223

RESUMO

A compact, reliable and low cost flow injection chemiluminescence system is described. The flow system consists of a set of solenoid micro-pumps that can dispense reproductive micro-volumes of solutions. The luminometer was based on a coiled cell constructed from polyethylene tubing that was sandwiched between two large area photodiodes. The whole equipment costs about US$ 750 and weights ca. 3 kg. Equipment performance was evaluated by measuring low concentrations of hydrogen peroxide by oxidation of luminol and for the determination of ammonium, based on its inhibition of the luminescence provided by the reaction of luminol and sodium hypochlorite. Linear responses were achieved within 1.0-80 micromol L(-1) H(2)O(2) and 0.6-60 micromol L(-1) NH(4)(+) with detection limits estimated as 400 nmol L(-1) H(2)O(2) and 60 nmol L(-1) NH(4)(+) at the 99.7% confidence level. Coefficients of variation were 1.0 and 1.8%, estimated for 20 micromol L(-1) H(2)O(2) and 15 micromol L(-1) NH(4)(+) (n=20), respectively. Reagent consumption of 55 microg luminol, effluent volume of 950 microL per determination and sampling rate of 120 samples per hour were also achieved.

13.
Talanta ; 62(4): 807-11, 2004 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-18969366

RESUMO

An on-line automated flow injection system with microwave-assisted sample digestion was used to perform silicate rock dissolution in acid medium for iron determination. For this purpose, a continuous flow system was built up by using an automatic flow injection analysis (FIA) system coupled to a flame atomic absorption spectrometer (FAAS), including a focused microwave oven unit. Inside the microwave cavity was inserted a polytetrafluoroethylene (PTFE) reactor coil (300cm length and 0.8mm i.d.) where the dissolution takes place. Chemical and flow variables as well as iron determination parameters were studied. In the flow system, a slurry of the rock sample (50mg in 200ml of acid mixture HF+HCl+HNO(3)) is pumped through the reaction coil and the microwaves are turned on. After elapsed the time required to complete the sample dissolution, the mixture is pumped again in order to fill the sampling loop (500mul). Then, by changing the valve position, a water carrier stream pushes the sample solution through the flame atomic absorption spectrometer nebulizer. To achieve an accurate determination of the rock certified materials, the slurry sample was irradiated during 210s at 90W power. Working in that condition, a detection limit of 0.80mugml(-1) (which corresponds to an Fe(2)O(3) content of 0.46%) and an analytical throughput of 10h(-1) were achieved. The relative standard deviation (R.S.D.) of the method varied between 1 and 11% when applied to the rock certified materials.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA