Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 57(22): E218-E223, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-30117905

RESUMO

In this paper, we show the experimental results of a thermally stable Si3N4 external cavity (SiN EC) laser with high power output and the lowest SiN EC laser threshold to our knowledge. The device consists of a 250 µm sized reflective semiconductor optical amplifier butt-coupled to a passive chip based on a series of Si3N4 Bragg gratings acting as narrow reflectors. A threshold of 12 mA has been achieved, with a typical side-mode suppression ratio of 45 dB and measured power output higher than 3 mW. Furthermore, we achieved a mode-hop free-lasing regime in the range of 15-62 mA and wavelength thermal stability up to 80°C. This solves the challenges related to cavity resonances' thermal shift and shows the possibility for this device to be integrated in dense wavelength-division multiplexing (WDM) and heat-intensive optical interconnects technologies.

2.
J Synchrotron Radiat ; 22(6): 1364-71, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26524300

RESUMO

A fast atomic force microscope (AFM) has been developed that can be installed as a sample holder for grazing-incidence X-ray experiments at solid/gas or solid/liquid interfaces. It allows a wide range of possible investigations, including soft and biological samples under physiological conditions (hydrated specimens). The structural information obtained using the X-rays is combined with the data gathered with the AFM (morphology and mechanical properties), providing a unique characterization of the specimen and its dynamics in situ during an experiment. In this work, lipid monolayers and bilayers in air or liquid environment have been investigated by means of AFM, both with imaging and force spectroscopy, and X-ray reflectivity. In addition, this combination allows the radiation damage induced by the beam on the sample to be studied, as has been observed on DOPC and DPPC supported lipid bilayers under physiological conditions.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Bicamadas Lipídicas/química , Micromanipulação/instrumentação , Microscopia de Força Atômica/instrumentação , Manejo de Espécimes/instrumentação , Difração de Raios X/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Integração de Sistemas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...