Circ Arrhythm Electrophysiol ; 2(6): 695-704, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19841033

RESUMO

BACKGROUND: The MRI-compatible electrophysiology system previously used for MR-guided left ventricular electroanatomic mapping was enhanced with improved MR tracking, an MR-compatible radiofrequency ablation system and higher-resolution imaging sequences to enable mapping, ablation, and ablation monitoring in smaller cardiac structures. MR-tracked navigation was performed to the left atrium (LA) and atrioventricular (AV) node, followed by LA electroanatomic mapping and radiofrequency ablation of the pulmonary veins (PVs) and AV node. METHODS AND RESULTS: One ventricular ablation, 7 PV ablations, 3 LA mappings, and 3 AV node ablations were conducted. Three MRI-compatible devices (ablation/mapping catheter, torqueable sheath, stimulation/pacing catheter) were used, each with 4 to 5 tracking microcoils. Transseptal puncture was performed under x-ray, with all other procedural steps performed in the MRI. Preacquired MRI roadmaps served for real-time catheter navigation. Simultaneous tracking of 3 devices was performed at 13 frames per second. LA mapping and PV radiofrequency ablation were performed using tracked ablation catheters and sheaths. Ablation points were registered and verified after ablation using 3D myocardial delayed enhancement and postmortem gross tissue examination. Complete LA electroanatomic mapping was achieved in 3 of 3 pigs, Right inferior PV circumferential ablation was achieved in 3 of 7 pigs, with incomplete isolation caused by limited catheter deflection. During AV node ablation, ventricular pacing was performed, 3 devices were simultaneously tracked, and intracardiac ECGs were displayed. 3D myocardial delayed enhancement visualized node injury 2 minutes after ablation. AV node block succeeded in 2 of 3 pigs, with 1 temporary block. CONCLUSIONS: LA mapping, PV radiofrequency ablation, and AV node ablation were demonstrated under MRI guidance. Intraprocedural 3D myocardial delayed enhancement assessed lesion positional accuracy and dimensions.


Assuntos
Nó Atrioventricular/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Imagem por Ressonância Magnética Intervencionista , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador , Animais , Nó Atrioventricular/patologia , Nó Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial , Ablação por Cateter/instrumentação , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Desenho de Equipamento , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Imagem por Ressonância Magnética Intervencionista/instrumentação , Modelos Animais , Valor Preditivo dos Testes , Veias Pulmonares/patologia , Veias Pulmonares/fisiopatologia , Cirurgia Assistida por Computador/instrumentação , Suínos
2.
Circulation ; 118(8): 853-62, 2008 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-18678773

RESUMO

BACKGROUND: X-ray fluoroscopy constitutes the fundamental imaging modality for catheter visualization during interventional electrophysiology procedures. The minimal tissue discriminative capability of fluoroscopy is mitigated in part by the use of electroanatomic mapping systems and enhanced by the integration of preacquired 3-dimensional imaging of the heart with computed tomographic or magnetic resonance (MR) imaging. A more ideal paradigm might be to use intraprocedural MR imaging to directly image and guide catheter mapping procedures. METHODS AND RESULTS: An MR imaging-based electroanatomic mapping system was designed to assess the feasibility of navigating catheters to the left ventricle in vivo using MR tracking of microcoils incorporated into the catheters, measuring intracardiac ventricular electrograms, and integrating this information with 3-dimensional MR angiography and myocardial delayed enhancement images to allow ventricular substrate mapping. In all animals (4 normal, and 10 chronically infarcted swine), after transseptal puncture under fluoroscopic guidance, catheters were successfully navigated to the left ventricle with MR tracking (13 to 15 frames per second) by both transseptal and retrograde aortic approaches. Electrogram artifacts related to the MR imaging gradient pulses were successfully removed with analog and digital signal processing. In all animals, it was possible to map the entire left ventricle and to project electrogram voltage amplitude maps to identify the scarred myocardium. CONCLUSIONS: It is possible to use MR tracking to navigate catheters to the left ventricle, to measure electrogram activity, and to render accurate 3-dimensional voltage maps in a porcine model of chronic myocardial infarction, completely in the MR imaging environment. Myocardial delayed enhancement guidance provided dense sampling of the proximity of the infarct and accurate localization of complex infarcts.


Assuntos
Técnicas Eletrofisiológicas Cardíacas/métodos , Ventrículos do Coração/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/patologia , Animais , Ablação por Cateter/métodos , Cateterismo/efeitos adversos , Cateterismo/métodos , Modelos Animais de Doenças , Ventrículos do Coração/patologia , Lidocaína/uso terapêutico , Infarto do Miocárdio/fisiopatologia , Suínos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/prevenção & controle
3.
Radiology ; 234(2): 551-7, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15591433

RESUMO

All procedures and protocols were approved by the institutional animal care and use committee of Columbia University. To determine whether transfemoral catheterization of the carotid arteries can be performed entirely with real-time magnetic resonance (MR) imaging guidance, the authors catheterized the carotid arteries in six domestic pigs by using active-tracking catheters and guidewires and MR tracking software created for neurovascular procedures. The carotid arteries were successfully catheterized 24 times, on average within 5 minutes after insertion of the catheter into the femoral artery. Results demonstrated the feasibility of performing transfemoral catheterization of the carotid arteries with active MR tracking devices in a conventional MR imaging unit.


Assuntos
Artérias Carótidas , Cateterismo/métodos , Angiografia por Ressonância Magnética/instrumentação , Animais , Estudos de Viabilidade , Feminino , Artéria Femoral , Angiografia por Ressonância Magnética/métodos , Suínos