Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 7(4): 731-8, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9243395

RESUMO

The purpose of this study was to analyze the effect of several magnetization transfer (MT) pulse and T1-weighted spin-echo (SE) sequence parameters on lesion-to-background contrast, using a simple tissue phantom emulating the T1 relaxation and MT properties of gadolinium-enhanced brain lesions. Eggbeaters (Nabisco Inc., East Hanover, NJ) liquid egg product was doped with gadolinium in six concentrations from .0 to 1.0 mmol and cooked. The gadolinium-doped egg phantom and normal volunteer brains were studied using an SE sequence with TE = 20 msec and high power, pulsed, off-resonance MT saturation. The effects of MT pulse frequency offset (1,000-6,000 Hz), sequence repetition time (TR = 500-1,000 msec, with MT power held constant), and slice-select flip angle (60-120 degrees) on the magnetization transfer ratio (MTR) and the simulated lesion-to-background contrast were determined at the different "intralesion" gadolinium concentrations. The MTR and lesion-to-background contrast of all materials were greatest at narrow MT pulse frequency offsets. There was in inverse relationship between gadolinium concentration and MTR and a positive correlation between the gadolinium concentration and lesion-to-background (L/B) contrast, a weak negative correlation between slice-select flip angle and L/B, and a negative correlation between TR and L/B. The relaxation properties and MT behavior of the egg phantom are close to that expected for enhancing brain lesions, allowing a rigorous analysis of several variables affecting lesion-to-background contrast for high MT power, T1-weighted SE sequences.


Assuntos
Encefalopatias/diagnóstico , Encéfalo/anatomia & histologia , Meios de Contraste , Gadolínio DTPA , Gadolínio , Imageamento por Ressonância Magnética/métodos , Adulto , Encéfalo/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Compostos Organometálicos , Ácido Pentético/análogos & derivados , Imagens de Fantasmas , Fatores de Tempo
2.
Radiology ; 199(1): 219-26, 1996 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8633148

RESUMO

PURPOSE: To evaluate white matter disorders with magnetization transfer (MT) techniques. MATERIALS AND METHODS: In 46 healthy volunteers and 46 clinical patients, MT Z spectra were obtained with various continuous-wave-equivalent MT powers (B1CW) and frequency offsets. RESULTS: With B1CW of 270 Hz and 4,000-Hz frequency offset, the MT ratio of normal callosal white matter was 59.2% +/- 1.5 (standard deviation), with less than 5% contribution from direct saturation and spin locking. A small statistically significant (P < .01) regional variation in normal white matter was seen. Plaques in MS patients had a broad (or wide) range of MT ratios; normal appearing white matter had a slightly reduced MT ratio. Vasogenic edema had a minimal effect on MT ratio, and radiation necrosis showed prominent reductions in MT ratio. CONCLUSION: High MT power techniques can expand the dynamic range of MT ratios, maintain a relatively pure MT effect, and be used effectively in MT imaging to evaluate white matter disorders.


Assuntos
Neoplasias Encefálicas/patologia , Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/patologia , Encéfalo/anatomia & histologia , Estudos de Casos e Controles , Humanos , Imagens de Fantasmas
3.
Radiology ; 190(2): 553-9, 1994 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8284415

RESUMO

PURPOSE: To prove that the contrast of enhancing brain lesions on post-gadolinium T1-weighted spin-echo (SE) images can be statistically significantly improved with magnetization-transfer (MT) indirect saturation. MATERIALS AND METHODS: The contrast-to-noise ratios (C/Ns) of 201 enhancing brain lesions in 110 patients were compared on conventional and MT T1-weighted SE images obtained at 1.5 T after injection of 0.05-0.10 mmol/kg gadopentetate dimeglumine or gadodiamide. RESULTS: The MT T1-weighted SE images showed a 37% reduction in signal intensity of background white matter and thereby provided a 108% improvement in the C/N of enhancing brain lesions over the conventional T1-weighted SE images (P < .001). CONCLUSION: The C/Ns obtained with single-dose gadolinium and the MT T1-weighted SE technique were twice those obtained with the conventional technique and are at least equivalent to reported values obtained with triple-dose gadolinium and conventional T1-weighted SE images.


Assuntos
Encefalopatias/diagnóstico , Meios de Contraste , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Meglumina , Compostos Organometálicos , Ácido Pentético/análogos & derivados , Encéfalo/patologia , Combinação de Medicamentos , Gadolínio DTPA , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA