Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Tidsskr Nor Laegeforen ; 144(4)2024 Mar 19.
Artigo em Norueguês | MEDLINE | ID: mdl-38506014

RESUMO

Background: The knowledge base on new psychoactive substances (NPS) is generally limited. This introduces new challenges and increased unpredictability in substance abuse treatment. Case presentation: A man in his thirties was submitted to detoxification after reportedly using flubromazolam, a high potency designer benzodiazepine, which he had purchased on the dark web. Extensive drug testing of serum, urine and hair, and the remains in a dropper bottle delivered by the patient, did not reveal flubromazolam or possible metabolites, but did reveal several common drugs of abuse, and 8-aminoclonazolam, a metabolite of clonazolam, another designer benzodiazepine sold on the dark web. The detoxification was uncomplicated. An excessive treatment protocol based on the patient's information, involving high preparedness and increased resources, both clinically and analytically, turned out to be unnecessary. Interpretation: The drug use and clinical course in this case proved to be more common than the unit prepared for. The case history illustrates both the challenges with users of NPS and the general unpredictability in substance abuse treatment.


Assuntos
Drogas Desenhadas , Transtornos Relacionados ao Uso de Substâncias , Masculino , Humanos , Benzodiazepinas/efeitos adversos , Detecção do Abuso de Substâncias/métodos , Psicotrópicos
2.
Forensic Sci Int ; 347: 111680, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37062138

RESUMO

Rocuronium is a neuromuscular blocking agent mainly used in anesthetic procedures. Two patients who died 53 and 76 days, respectively, after their last rocuronium exposure had low (0.002-0.007 mg/L) levels of the drug in femoral blood, urine and vitreous humor samples obtained at autopsy. In neither case, the cause of death was related to the exposure to rocuronium. Here, these two cases are presented and the implications of the findings discussed.


Assuntos
Bloqueadores Neuromusculares , Fármacos Neuromusculares não Despolarizantes , Humanos , Rocurônio , Fármacos Neuromusculares não Despolarizantes/efeitos adversos , Androstanóis/efeitos adversos
3.
Basic Clin Pharmacol Toxicol ; 130(3): 415-422, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34964262

RESUMO

BACKGROUND AND OBJECTIVES: Metformin is used to treat gestational diabetes. It is also used to treat women with polycystic ovary syndrome and has been shown to prevent late miscarriage and preterm birth. However, increased renal clearance during pregnancy causes a decline in serum concentrations of metformin. The aim of this study was to explore the time course of the pregnancy-related changes in metformin pharmacokinetics and the return to the non-pregnant state. METHOD: A subgroup of women in the PregMet2 study (n = 73) agreed to provide serum samples at three time-points in pregnancy (gestational weeks 19, 28 and 32) and once in post partum, (either 2, 4 or 8 weeks after delivery). Serum metformin concentrations were compared using a four-parameter logistic model. FINDINGS: The mean steady-state serum concentration of metformin during pregnancy was 9.39 µmoL/L, whereas the post partum concentration was 12.36 µmoL/L, an increase of 32% (p = 0,019). This change took place already during the first 2 weeks post partum. CONCLUSION: Clinicians who treat pregnant women with metformin should be aware of the significant decrease in metformin concentration mediated by pregnancy, and the rapid increase after delivery, as it may impact both the therapeutic efficacy and the risk of adverse drug reactions.


Assuntos
Aborto Espontâneo , Metformina , Síndrome do Ovário Policístico , Nascimento Prematuro , Aborto Espontâneo/induzido quimicamente , Feminino , Humanos , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/farmacocinética , Recém-Nascido , Metformina/efeitos adversos , Síndrome do Ovário Policístico/tratamento farmacológico , Gravidez
4.
Forensic Sci Int ; 311: 110274, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32302877

RESUMO

The introduction of new psychoactive substances (NPS) on the illicit drug market has led to major challenges for the analytical laboratories. Keeping screening methods up to date with all relevant drugs is hard to achieve and the risk of missing important findings in biological samples is a matter of concern. Aiming for an extended retrospective data analysis, diagnostic fragment ions from synthetic cannabinoids (n=251), synthetic opioids (n=88) and designer benzodiazepines (n=26) not included in our original analytical method were obtained from the crowdsourced database HighResNPS.com and converted to a personalized library in a format compatible with the analytical instrumentation. Data files from the analysis of 1314 forensic post mortem samples with an Agilent 6540 ultra high pressure liquid chromatography quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS) performed in our laboratory from January 2014 to December 2018 were retrieved and retrospectively processed with the new personalized library. Potentially positive findings were grouped in two: The most confident findings contained MS/MS data for library match (category 1) whereas the less confident findings lacked such data (category 2). Five new category 1 findings were identified: Flubromazepam in two data files from 2015 and 2016, respectively, phenibut (4-amino-3-phenylbutyric acid) in one data file from 2015, fluorofentanyl in one data file from 2016 and cyclopropylfentanyl in one data file from 2018. Retention time matches with reference standards further strengthened these findings. A list of 35 presumably positive category 2 findings was generated. Of these, only one finding of phenibut was considered plausible after checking retention times and signal-to-noise ratios. This study shows that new compounds can be detected retrospectively in data files from QTOF-MS using an updated library containing diagnostic fragment ions. Automatic screening procedures can be useful, but a manual re-evaluation of positive findings will always be necessary.


Assuntos
Analgésicos Opioides/análise , Benzodiazepinas/análise , Canabinoides/análise , Drogas Desenhadas/análise , Medicamentos Sintéticos/análise , Cromatografia Líquida de Alta Pressão/métodos , Toxicologia Forense , Humanos , Drogas Ilícitas/análise , Espectrometria de Massas , Estudos Retrospectivos , Detecção do Abuso de Substâncias
5.
J Anal Toxicol ; 44(2): 140-148, 2020 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-31788682

RESUMO

New psychoactive substances are emerging on the illegal drug market. Synthetic opioids including fentanyl analogues are of special concern due to their high potency. This indicates the possibility of low drug concentrations in vivo and calls for sensitive analytical methods and identification of the most appropriate analytical targets. In this study the in vitro metabolism of ortho-, meta- and para-fluorofentanyl, three fluorinated derivatives of fentanyl, has been investigated using human hepatocytes and compared to the results from an authentic human urine sample. Based on knowledge on the metabolism of similar fentanyl analogues N-dealkylation and hydroxylation was hypothesized to be the most central pathways. The three fluorofentanyl isomers were incubated with pooled human hepatocytes at 1, 3 and 5 h. Liquid chromatography quadrupole time of flight mass spectrometry operating in data-dependent mode was used to analyse the hepatocyte samples, as well as the hydrolysed and non-hydrolysed authentic urine sample. Data were analysed by a targeted approach with a database of potential metabolites. The major metabolite formed in vitro was the N-dealkylation product norfluorofentanyl. In addition various hydroxylated metabolites, a N-oxide, dihydrodiol metabolites and a hydroxymethoxy metabolite were found. In total, 14 different metabolites were identified for each fluorofentanyl isomer. In the authentic urine sample, three metabolites were detected in addition to the ortho-fluorofentanyl parent compound, with hydroxymethoxy metabolite having the highest abundance followed by norfluorofentanyl and a metabolite hydroxylated on the ethylphenyl ring. This in vitro study showed that the metabolic pattern for ortho-, meta-, and para-fluorofentanyl was close to those previously reported for other fentanyl analogues. We suggest that the hydroxymethoxy metabolite and the metabolite hydroxylated on the ethylphenyl ring should be the metabolites primarily investigated in further studies to determine the most appropriate marker for intake of fluorofentanyl derivatives in urine drug screening for human subjects.


Assuntos
Fentanila/metabolismo , Hepatócitos/metabolismo , Drogas Ilícitas/metabolismo , Detecção do Abuso de Substâncias , Analgésicos Opioides , Cromatografia Líquida , Drogas Desenhadas , Fentanila/análogos & derivados , Fentanila/química , Humanos , Hidrólise , Hidroxilação , Drogas Ilícitas/química , Espectrometria de Massas , Microssomos Hepáticos
6.
Drug Test Anal ; 11(1): 51-67, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29996011

RESUMO

Synthetic cannabinoids are one of the most significant groups within the category new psychoactive substances (NPS) and in recent years new compounds have continuously been introduced to the market of recreational drugs. A sensitive and quantitative screening method in urine with metabolites of frequently seized compounds in Norway (AB-FUBINACA, AB-PINACA, AB-CHMINACA, AM-2201, AKB48, 5F-AKB48, BB-22, JWH-018, JWH-073, JWH-081, JWH-122, JWH-203, JWH-250, PB-22, 5F-PB-22, RCS-4, THJ-2201, and UR-144) using ultra-high pressure liquid chromatography-quadrupole time of flight-mass spectrometry (UHPLC-QTOF-MS) has been developed. The samples were treated with ß-glucuronidase prior to extraction and solid-phase extraction was used. Liquid handling was automated using a robot. Chromatographic separation was achieved using a C18-column and a gradient of water and acetonitrile, both with 0.1% formic acid. Each sample was initially screened for identification and quantification followed by a second injection for confirmation. The concentrations by which the compounds could be confirmed varied between 0.1 and 12 ng/mL. Overall the validation showed that the method fulfilled the set criteria and requirements for matrix effect, extraction recovery, linearity, precision, accuracy, specificity, and stability. One thousand urine samples from subjects in drug withdrawal programs were analyzed using the presented method. The metabolite AB-FUBINACA M3, hydroxylated metabolite of 5F-AKB48, hydroxylated metabolite of AKB48, AKB48 N-pentanoic acid, 5F-PB-22 3-carboxyindole, BB-22 3-carboxyindole, JWH-018 N-(5-hydroxypentyl), JWH-018 N-pentanoic acid, and JWH-073 N-butanoic acid were quantified and confirmed in 2.3% of the samples. The method was proven to be sensitive, selective and robust for routine use for the investigated metabolites.


Assuntos
Canabinoides/química , Canabinoides/urina , Drogas Ilícitas/química , Drogas Ilícitas/urina , Detecção do Abuso de Substâncias/métodos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Humanos , Estudos Retrospectivos , Detecção do Abuso de Substâncias/normas , Espectrometria de Massas em Tandem/normas
7.
Artigo em Inglês | MEDLINE | ID: mdl-29783197

RESUMO

BACKGROUND: Poor drug adherence in hypertensive patients can lead to treatment failure and increased cardiovascular morbidity, as well as increased costs to society. An analytical method based on ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MSMS) was developed and validated for use in routine therapeutic drug monitoring (TDM). The method includes 21 antihypertensive drugs or active metabolites from the groups beta blockers (n=5), calcium antagonists (n=5), angiotensin II receptor antagonists (n=4), angiotensin converting enzyme (ACE) inhibitors (n=3) and diuretics (n = 3), in addition to one α1-selective alpha blocker. METHOD: A 200 µL serum sample was handled automatically using a pipetting robot. Protein precipitation was performed with 600 µL of 1% formic acid in acetonitrile (v:v) and phospholipid removal was carried out using a Waters OSTRO™ 96-well plate. After evaporation and reconstitution the eluent was injected thrice with different inlet and mass spectrometric methods to cover the different physico-chemical properties of the drugs and the variations in therapeutic concentration ranges between drugs. Acquity UPLC BEH C18 (2.1x50mm, 1.7 µm) column equipped with a corresponding pre-column was used for chromatographic separation. For every analyte an isotopically labelled analogue served as internal standard, except for lisinopril where enalaprilat-d5 was used. RESULTS: Accuracies were in the range of -13.7 to 13.2% and intra-day and inter-day precisions in the range of 1.1 to 10.5%. The linearity within the calibration ranges expressed as coefficient of determination was higher than 0.995 for all compounds. Matrix effects and recovery efficiencies were within acceptable limits. The limits of quantitation varied from 0.02 to 10.7 µg/L. The stability of the drugs in serum at different conditions was tested. Diltiazem was not stable at 4-8 °C with up to 23.5 % loss after six days. Degradation of atenolol, irbesartan, bendroflumethiazide, hydrochlorothiazide and diltiazem was observed when stored at 30 °C. The suitability of the method was demonstrated in a routine TDM setting, analysing samples from 127 patients undergoing antihypertensive drug treatment.


Assuntos
Anti-Hipertensivos/sangue , Monitoramento de Medicamentos/métodos , Espectrometria de Massas em Tandem/métodos , Antagonistas Adrenérgicos alfa/sangue , Antagonistas Adrenérgicos beta/sangue , Antagonistas de Receptores de Angiotensina/sangue , Inibidores da Enzima Conversora de Angiotensina/sangue , Bloqueadores dos Canais de Cálcio/sangue , Calibragem , Cromatografia Líquida de Alta Pressão/métodos , Diuréticos/sangue , Humanos , Limite de Detecção , Metaboloma/fisiologia , Reprodutibilidade dos Testes , Soro
8.
J Anal Toxicol ; 41(8): 708-709, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28985336

RESUMO

Two young males were hospitalized with miosis and respiratory dysfunction after exposure to a white powder obtained from a foreign source by mail. A few days later, one of the males was found dead at his home. A serum sample from one of the hospitalized patients and a blood sample from the deceased contained ortho-fluorofentanyl in concentrations of 2.5 and 2.4 ng/mL, respectively. It was concluded that death was caused by ortho-fluorofentanyl.


Assuntos
Analgésicos Opioides/sangue , Overdose de Drogas/diagnóstico , Fentanila/sangue , Adulto , Overdose de Drogas/sangue , Evolução Fatal , Fentanila/análogos & derivados , Hospitalização , Humanos , Masculino , Miose/diagnóstico , Insuficiência Respiratória/diagnóstico
9.
Gynecol Oncol ; 145(1): 148-153, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28202195

RESUMO

OBJECTIVE: Evaluate long-term cisplatin-induced ototoxicity in women treated for malignant ovarian germ cell tumors (MOGCT). METHODS: Seventy-four women treated for MOGCT in Norway (1980-2009) were analyzed: 41 had received cisplatin-based chemotherapy (CBCT) ("Cases") and 33 had no CBCT ("Controls"). Median follow-up was 15years. Hearing was assessed by pure tone audiometry and by the SCIN questionnaire. Air conduction thresholds were reported as absolute hearing thresholds and age-adjusted thresholds. Absolute and age-adjusted hearing loss were defined as thresholds of >20dB at any frequency. Tinnitus was evaluated using the Tinnitus Handicap Inventory. Serum Platinum Concentration (SPC) was determined. RESULTS: Absolute hearing loss was identified in 21 Cases (51%) and 24 Controls (73%). After adjusting for age, only 9 Cases (22%) and 5 Controls (15%) remained. Age-adjusted hearing thresholds at 4, 6 and 8kHz were slightly but significantly higher in Cases compared to Controls. Subjective hearing loss was reported by 27% of Cases and 21% of Controls, who were significantly older. Elevated SPC values were detected up to 20years after CBCT, but SPC did not correlate significantly with age-adjusted hearing loss. The rate of tinnitus was similar in Cases and Controls. CONCLUSION: Long-term MOGCT survivors treated with CBCT have small but significant reductions in age-adjusted hearing thresholds at 4, 6 and 8kHz versus Controls. Approximately one in four women experienced subjective hearing loss. To avoid overestimation of clinically relevant cisplatin-induced ototoxicity, absolute hearing thresholds should be age-adjusted and compared to an age-matched control group.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Cisplatino/efeitos adversos , Perda Auditiva/induzido quimicamente , Neoplasias Embrionárias de Células Germinativas/tratamento farmacológico , Neoplasias Ovarianas/tratamento farmacológico , Ovariectomia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Audiometria de Tons Puros , Bleomicina/administração & dosagem , Estudos de Casos e Controles , Quimioterapia Adjuvante , Criança , Cisplatino/administração & dosagem , Etoposídeo/administração & dosagem , Feminino , Perda Auditiva/sangue , Humanos , Estudos Longitudinais , Pessoa de Meia-Idade , Platina/sangue , Vimblastina/administração & dosagem , Adulto Jovem
11.
J Biomed Mater Res A ; 100(11): 2939-47, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22700168

RESUMO

Microbeads of alginate crosslinked with Ca(2+) and/or Ba(2+) are popular matrices in cell-based therapy. The aim of this study was to quantify the binding of barium in alginate microbeads and its leakage under in vitro and accumulation under in vivo conditions. Low concentrations of barium (1 mM) in combination with calcium (50 mM) and high concentrations of barium (20 mM) in gelling solutions were used for preparation of microbeads made of high-G and high-M alginates. High-G microbeads accumulated barium from gelling solution and contained higher concentrations of divalent ions for both low- and high-Ba exposure compared with high-G microbeads exposed to calcium solely and to high-M microbeads for all gelling conditions. Although most of the unbound divalent ions were removed during the wash and culture steps, leakage of barium was still detected during storage. Barium accumulation in blood and femur bone of mice implanted with high-G beads was found to be dose-dependent. Estimated barium leakage relevant to transplantation to diabetic patients with islets in alginate microbeads showed that the leakage was 2.5 times lower than the tolerable intake value given by WHO for high-G microbeads made using low barium concentration. The similar estimate gave 1.5 times higher than is the tolerable intake value for the high-G microbeads made using high barium concentration. To reduce the risk of barium accumulation that may be of safety concern, the microbeads made of high-G alginate gelled with a combination of calcium and low concentration of barium ions is recommended for islet transplantation.


Assuntos
Alginatos/química , Bário/sangue , Bário/química , Reagentes de Ligações Cruzadas/química , Géis/química , Animais , Bário/metabolismo , Cálcio/química , Reagentes de Ligações Cruzadas/metabolismo , Fêmur/metabolismo , Ácido Glucurônico/química , Ácidos Hexurônicos/química , Laminaria/química , Macrocystis/química , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Microesferas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...