Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Br J Neurosurg ; 37(5): 1410-1413, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33044094

RESUMO

We describe a novel MRI sequence (T2 SPACE) capable of demonstrating detailed structural anatomy and functional CSF flow information simultaneously. While traditionally, a variety of sequences are utilised for this purpose, we have highlighted the advantages of this technique over traditional approaches, using example of a patient with CSF loculation in prepontine/suprasellar cistern, causing third ventricular compression and hydrocephalus. The sequence depicted the surgical anatomy by showing the web/cyst wall as well as CSF flow entering the cyst potentially causing increased pressure.


Assuntos
Cistos , Hidrocefalia , Terceiro Ventrículo , Humanos , Hidrocefalia/diagnóstico por imagem , Hidrocefalia/cirurgia , Hidrocefalia/etiologia , Terceiro Ventrículo/cirurgia , Imageamento por Ressonância Magnética , Ventriculostomia/métodos , Cistos/complicações
3.
Eur J Hybrid Imaging ; 4(1): 21, 2020 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-34191154

RESUMO

PURPOSE: To quantify incidental thyroid pathology including malignancy on routine 18F-FDG PET-CT scans To compare standardised uptake values (SUVmax) in thyroid malignancy subtypes METHODS AND MATERIALS: This is a retrospective study of all 18F-FDG PET-CT scans (n = 6179) performed in a teaching hospital between June 2010 and May 2019. RIS database search of reports for the word "thyroid" was performed. Studies with evidence of thyroid uptake were included. Patient age and gender, primary indication for PET scan (malignant or non-malignant), thyroid result on PET (diffuse or focal tracer uptake, SUVmax), ultrasound and FNAC results were recorded. RESULTS: Incidental abnormal thyroid tracer uptake as a proportion of all 18F-FDG PET-CT scans was 4.37% (n = 270). Out of region patients (n = 87) whose records could not be obtained were excluded leaving a study group of n = 183. Ninety-four in this group had focal uptake, and 89 had diffuse uptake. Fifty-five patients in the focal group had undergone further investigations. Of these, 30 were thought to be benign on USS alone, and 25 patients underwent USS/FNAC. Thirteen (24%) malignancies were identified (5 papillary, 6 follicular, 1 poorly differentiated thyroid cancer, 1 metastatic malignancy). Mean SUVmax for papillary carcinoma was noted to be 8.2 g/ml, and follicular carcinoma was 12.6 g/ml. CONCLUSION: Incidental abnormal thyroid 18F-FDG PET-CT uptake in PET-CT scans of 4.37% is in keeping with the known limited literature. Rather similar number of patients was noted in the focal and diffuse tracer uptake categories in the final study group. Around quarter of the focal lesions were identified to be malignant, implying focal lesions should always be further investigated.

4.
Eur Radiol ; 29(5): 2340-2349, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30488106

RESUMO

OBJECTIVES: To compare aortic size and stiffness parameters on MRI between bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV) patients with aortic stenosis (AS). METHODS: MRI was performed in 174 patients with asymptomatic moderate-severe AS (mean AVAI 0.57 ± 0.14 cm2/m2) and 23 controls on 3T scanners. Valve morphology was available/analysable in 169 patients: 63 BAV (41 type-I, 22 type-II) and 106 TAV. Aortic cross-sectional areas were measured at the level of the pulmonary artery bifurcation. The ascending and descending aorta (AA, DA) distensibility, and pulse wave velocity (PWV) around the aortic arch were calculated. RESULTS: The AA and DA areas were lower in the controls, with no difference in DA distensibility or PWV, but slightly lower AA distensibility than in the patient group. With increasing age, there was a decrease in distensibility and an increase in PWV. After correcting for age, the AA maximum cross-sectional area was higher in bicuspid vs. tricuspid patients (12.97 [11.10, 15.59] vs. 10.06 [8.57, 12.04] cm2, p < 0.001), but there were no significant differences in AA distensibility (p = 0.099), DA distensibility (p = 0.498) or PWV (p = 0.235). Patients with BAV type-II valves demonstrated a significantly higher AA distensibility and lower PWV compared to type-I, despite a trend towards higher AA area. CONCLUSIONS: In patients with significant AS, BAV patients do not have increased aortic stiffness compared to those with TAV despite increased ascending aortic dimensions. Those with type-II BAV have less aortic stiffness despite greater dimensions. These results demonstrate a dissociation between aortic dilatation and stiffness and suggest that altered flow patterns may play a role. KEY POINTS: • Both cellular abnormalities secondary to genetic differences and abnormal flow patterns have been implicated in the pathophysiology of aortic dilatation and increased vascular complications associated with bicuspid aortic valves (BAV). • We demonstrate an increased ascending aortic size in patients with BAV and moderate to severe AS compared to TAV and controls, but no difference in aortic stiffness parameters, therefore suggesting a dissociation between dilatation and stiffness. • Sub-group analysis showed greater aortic size but lower stiffness parameters in those with BAV type-II AS compared to BAV type-I.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Valva Tricúspide/diagnóstico por imagem , Rigidez Vascular , Adulto , Idoso , Aorta/fisiopatologia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Aorta Torácica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/patologia , Doença da Válvula Aórtica Bicúspide , Dilatação Patológica , Feminino , Doenças das Valvas Cardíacas/patologia , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Onda de Pulso , Valva Tricúspide/patologia , Valva Tricúspide/fisiopatologia
5.
BJR Open ; 1(1): 20180011, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-33178908

RESUMO

OBJECTIVE: Despite having a detailed MRI-safety questionnaire check at the point of referral, we have encountered a significant number of near-misses with patients being identified with MRI-Unsafe devices at the time of appointments, making this an important safety hazard. METHODS AND MATERIALS: A two-part survey was performed to assess referrer compliance of asking MRI-questionnaires. 120 outpatients across 3 MRI sites were interviewed at the time of appointment to confirm whether their referrers completed the MRI questionnaires with them at the time of referral.Location:Department of Radiology, Ninewells Hospital, Perth Royal Infirmary and Stracathro Hospital in Scotland. RESULTS: Only 50-55 % of patients confirmed that they were asked about presence of a pacemaker at the point of referral. Less than 50 % of patients reported being asked about other potential hazards.Suggested strategies for change: (1) Risk Alert-Sent to all MRI referrers in the organization. ( 2) Changes to MRI Safety Questionnaire. (3) Feedback mechanism to referrers-NHS trust website publications on number of recorded near-misses and wasted appointments due to MRI-safety issues. (4) Compulsory education/training of future referrers (junior doctors/allied health professionals). (5) Education of patients/public on MRI safety-Displaying patient information leaflets/posters in waiting areas of the hospital.Key measures for improvement: (1) Reduction in number of recorded near-misses. (2) System improvements, referrer and patient education, reduction of wasted MRI appointments and improvement of waiting-times for MRI appointments Effects of survey and conclusions: The survey highlights the possibility of inadequate referrer attention, and poor patient communication about MRI safety questionnaire with regards to potential hazards of MRI examination in presence of undeclared implants. It initiated several interventions resulting in improved patient safety, with no events in next 12 months, whilst promoting public and referrer's understanding of potential MRI safety issues. Such actions are recommended for all NHS centres across UK since there are significant similarities in functioning across UK.

6.
Clin Nucl Med ; 41(3): 219-20, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26673236

RESUMO

We report an unusual artifact, which was seen on a routine preoperative chest radiograph performed in a patient with breast cancer, before an elective mastectomy. Subsequently, this was identified to be secondary to a preoperative sentinel node injection. The report discusses the diagnostic dilemma caused by this artifact and raises the awareness of this possibility in patients undergoing these commonly performed procedures and investigations.


Assuntos
Artefatos , Neoplasias da Mama/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Feminino , Humanos , Metástase Linfática , Mastectomia , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...