Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev. ABRO ; 6(2): 42-47, jun. -dez. 2005. ilus
Artigo em Inglês | BBO - Odontologia | ID: biblio-855418

RESUMO

The aim of this study was to assess the adequacy of x-rays units for intraoral radiographic techniques in Salvador, Bahia (Brazil). The sample was composed of 150 units randomly selected from a total of 652 units evaluated by a dosimetry kit (IRD/CNEN Institute of Radiation Protection and Dosimetry of the National Commission of Nuclear Energy - Ministry of Health). Three parametrs were considered: (a)maximum skin exposure, 500 mRem; (b)radiation field size, 5.0-6.0 cm; and (c)minimum aluminum filtration, 1.5 mm. If any of the parameters did not comply with IRD/CNEN standards, the x-ray unit was considered to be out of order. Pearson's correlation test, degree of dependence (Pearson's Qui-square test), and the degree of association between the variables (V Cramér coefficient)were used for the statistical analysis. The results showed that 59.33 porcento of the units failed to comply with at least one of the three parameters evaluated. Radiation field size was the criterion that showed the highest level of failure (40.67 porcento). Filtration and skin exposure were responsible for the failure of 30 por cento and 20.7 por cento of the x-ray units, respectively. Perarson's correlation test showed a statistically significant positive correlation between skin exposure and radiation field size, and negative correlation between skin exposure and filtration, indicating that akin exposure tends to increase with the size of the radiation field and/or decreases with filtration. The highest association was detected between skin exposure and filtration. The results show the importance of promoting an educational program about source-skin distance, exposure time, film sensitivity, film processing, film-holding devices; adopting filtration and collimation standards; and the use of rectangular collimator as mandatory. Such a program and update of the rules would stimulate increased use of the ALARA principle (as low as reasonably achievable) for patients undergoing intraoral radiography


Assuntos
Controle da Radiação/efeitos adversos , Exposição à Radiação , Equipamentos e Provisões/efeitos adversos , Medida de Exposição à Radiação , Radiometria/efeitos adversos
2.
Rev. fac. odontol. Univ. Fed. Bahia ; 29: 60-65, jul.-dez. 2004. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-858024

RESUMO

A doença periodontal é uma entidade nosológica multifatorial de caráter infeccioso inflamatório. Os linfomas não Hodgkin caracterizam um grupo de neoplasias malignas de natureza linfática, originadas geralmente de linfócitos B ou linfócitos T; apresentam facilidade em apresentar metástase e seu tratamento deve ser baseado na rádio e quimioterapia. Tais terapias são baseadas na destruição de células malignas, entretanto, atuam de forma inespecífica, podendo desencadear um estado de imunossupressão, agravando a severidade dos processos infecciosos. Portanto, é imprativa a eliminação de qualquer foco infeccioso na cavidade oral, previamente às seções de químio e radioterapia, para não expor estes pacientes à destruição periodontal; uma vez que neles, a defesa imunológica apresenta-se suprimida, alterando o equilibrio e permitindo a disseminação da infecção de forma mais rápida e severa. O objetivo deste estudo é apresentar a conduta a ser tomada para pacientes portadores de Linforma não-Hodgkin, enfatizando a necessidade de terapia periodontal anterior à radio e quimioterapia.


Assuntos
Humanos , Masculino , Idoso , Doenças Periodontais/tratamento farmacológico , Doenças Periodontais/radioterapia , Linfoma não Hodgkin/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...