Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Thromb Haemost ; 16(10): 2050-2056, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30007048

RESUMO

Essentials ClotChip is a novel microsensor for comprehensive assessment of ex vivo hemostasis. Clinical samples show high sensitivity to detecting the entire hemostatic process. ClotChip readout exhibits distinct information on coagulation factor and platelet abnormalities. ClotChip has potential as a point-of-care platform for comprehensive hemostatic analysis. SUMMARY: Background Rapid point-of-care (POC) assessment of hemostasis is clinically important in patients with a variety of coagulation factor and platelet defects who have bleeding disorders. Objective To evaluate a novel dielectric microsensor, termed ClotChip, which is based on the electrical technique of dielectric spectroscopy for rapid, comprehensive assessment of whole blood coagulation. Methods The ClotChip is a three-dimensional, parallel-plate, capacitive sensor integrated into a single-use microfluidic channel with miniscule sample volume (< 10 µL). The ClotChip readout is defined as the temporal variation in the real part of dielectric permittivity of whole blood at 1 MHz. Results The ClotChip readout exhibits two distinct parameters, namely, the time to reach a permittivity peak (Tpeak ) and the maximum change in permittivity after the peak (Δεr,max ), which are, respectively, sensitive towards detecting non-cellular (i.e. coagulation factor) and cellular (i.e. platelet) abnormalities in the hemostatic process. We evaluated the performance of ClotChip using clinical blood samples from 15 healthy volunteers and 12 patients suffering from coagulation defects. The ClotChip Tpeak parameter exhibited superior sensitivity at distinguishing coagulation disorders as compared with conventional screening coagulation tests. Moreover, the ClotChip Δεr,max parameter detected platelet function inhibition induced by aspirin and exhibited strong positive correlation with light transmission aggregometry. Conclusions This study demonstrates that ClotChip assesses multiple aspects of the hemostatic process in whole blood on a single disposable cartridge, highlighting its potential as a POC platform for rapid, comprehensive hemostatic analysis.


Assuntos
Transtornos da Coagulação Sanguínea/diagnóstico , Coagulação Sanguínea , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , Testes Imediatos , Transdutores , Tempo de Coagulação do Sangue Total/instrumentação , Aspirina/farmacologia , Transtornos da Coagulação Sanguínea/sangue , Fatores de Coagulação Sanguínea/metabolismo , Estudos de Casos e Controles , Espectroscopia Dielétrica , Desenho de Equipamento , Humanos , Agregação Plaquetária/efeitos dos fármacos , Inibidores da Agregação Plaquetária/farmacologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
2.
Technology (Singap World Sci) ; 4(2): 71-79, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27437432

RESUMO

In sickle cell disease (SCD), hemoglobin molecules polymerize intracellularly and lead to a cascade of events resulting in decreased deformability and increased adhesion of red blood cells (RBCs). Decreased deformability and increased adhesion of sickle RBCs lead to blood vessel occlusion (vaso-occlusion) in SCD patients. Here, we present a microfluidic approach integrated with a cell dimensioning algorithm to analyze dynamic deformability of adhered RBC at the single-cell level in controlled microphysiological flow. We measured and compared dynamic deformability and adhesion of healthy hemoglobin A (HbA) and homozygous sickle hemoglobin (HbS) containing RBCs in blood samples obtained from 24 subjects. We introduce a new parameter to assess deformability of RBCs: the dynamic deformability index (DDI), which is defined as the time-dependent change of the cell's aspect ratio in response to fluid flow shear stress. Our results show that DDI of HbS-containing RBCs were significantly lower compared to that of HbA-containing RBCs. Moreover, we observed subpopulations of HbS containing RBCs in terms of their dynamic deformability characteristics: deformable and non-deformable RBCs. Then, we tested blood samples from SCD patients and analyzed RBC adhesion and deformability at physiological and above physiological flow shear stresses. We observed significantly greater number of adhered non-deformable sickle RBCs than deformable sickle RBCs at flow shear stresses well above the physiological range, suggesting an interplay between dynamic deformability and increased adhesion of RBCs in vaso-occlusive events.

3.
Transplant Proc ; 46(6): 2125-32, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25131122

RESUMO

Intestinal transplantation is the most effective treatment for patients with short bowel syndrome and small bowel insufficiencies. We evaluated epithelial chimerism after infusion of autologous bone marrow mesenchymal stromal cells (BMSCs) in patients undergoing cadaveric donor isolated intestinal transplantation (I-ITx). BMSCs were isolated from patients' bone marrow via iliac puncture and expanded in vitro prior to infusion. Two out of the 3 patients were infused with autologous BMSCs, and small intestine tissue biopsies collected post-operatively were analyzed for epithelial chimerism using XY fluorescent in situ hybridization and short tandem repeat polymerase chain reaction. We observed epithelial chimeric effect in conditions both with and without BMSC infusion. Although our results suggest a higher epithelial chimerism effect with autologous BMSC infusion in I-ITx, the measurements in multiple biopsies at different time points that demonstrate the reproducibility of this finding and its stability or changes in the level over time would be beneficial. These approaches may have potential implications for improved graft survival, lower immunosuppressant doses, superior engraftment of the transplanted tissue, and higher success rates in I-ITx.


Assuntos
Transplante de Medula Óssea/métodos , Quimerismo , Intestino Delgado/transplante , Células-Tronco Mesenquimais/citologia , Doadores de Tecidos , Adolescente , Adulto , Criança , Feminino , Sobrevivência de Enxerto , Humanos , Imunossupressores/uso terapêutico , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...