Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Dent Mater ; 40(4): 619-628, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38369403

RESUMO

OBJECTIVES: To evaluate the clinical performance of posterior restorations over wet and dry dentin with an etch-and-rinse adhesive after 36 months of clinical service. METHODS: Forty-five participants were recruited, each one had at least two posterior teeth that needed restoration. Ninety restorations were placed on Class I or Class II cavities. For the restoration protocol, a simplified etch-and-rinse adhesive (Adper Single Bond 2) was applied over wet (WD) or dry dentin (DD) and later restored with a bulk-fill composite (Filtek Bulk Fill) under rubber dam isolation. Each restoration was evaluated using the World Dental Federation (FDI) criteria after 6, 12, and 36 months of clinical service, regarding the following principal restoration characteristics: postoperative sensitivity, marginal discoloration, marginal adaptation, fracture of material and retention, and recurrence of caries. Kruskal Wallis analysis of variance rank (α = 0.05) and Kaplan-Meier survival analysis were used for statistical analysis. RESULTS: After 36 months of clinical evaluation, no significant difference between groups was observed in each FDI criterion (p > 0.05). Twenty restorations (WD=10, DD=10) showed minor marginal staining, and twenty-two restorations (WD=11, DD=11) presented small marginal adaptation defects (p > 0.05). Four restorations were lost (WD = 2, DD = 2) and the fracture rates (95% confidence interval) were 94.9% for each one, without significant difference between wet and dry dentin (p > 0.05). SIGNIFICANCE: The degree of dentin moisture does not seem to affect the clinical performance of a simplified etch-and-rinse adhesive in posterior restorations when the adhesive is applied vigorously over the dentine surface.


Assuntos
Cárie Dentária , Cimentos Dentários , Humanos , Adesivos Dentinários/química , Cimentos de Resina , Restauração Dentária Permanente/métodos , Resinas Compostas/química , Cárie Dentária/terapia , Dentina , Adaptação Marginal Dentária
2.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1528750

RESUMO

Objectives: To evaluate the effect of pressure on the skin of upper lip in decreasing pain perception during a local maxillary anesthetic injection. Material and Methods: A split-mouth crossover randomized clinical trial was designed. Seventy-one volunteer students (23.6±1.9 years old, 53.5% women) were selected. A group chosen at random had their left or right side of upper lip compressed by a wooden clothes peg as the compression instrument and 0.6 ml of lidocaine 2% with epinephrine 1:100,000 was administered at the buccal apex level of the lateral incisors tooth. Two weeks later anesthesia was administered on the opposite side of the lip according to the randomization recorded. The intensity of perceived pain level between the two injections using a 100 mm visual analog scale (VAS) and co-variable effect were compared (Wilcoxon test p < 0.05, RStudio). Results: The average of the perceived pain with and without upper lip compression was 27.6±14.5 mm (range 0-80 mm) and 36.33±17.9 mm (range 10-90 mm) respectively (p= 0.002). No significant differences were recorded according the covariance analysis with the sex (p = 0.55) and age (p = 0.89). Conclusion: The upper lip compression significantly reduces the perception of pain during a local maxillary anesthetic technique.

3.
Cranio ; 40(1): 48-54, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31663426

RESUMO

Objective: To evaluate the activity of mentalis (MN), buccinator (BC), and suprahyoid (SH) muscles among participants with different lip competence..Methods: Sixty-three participants were classified clinically and assigned to the following groups of 21 each: 1) competent lips (competent), 2) incompetent lips (incompetent), or 3) forced lip closure (forced). Activity was recorded at rest, swallowing, speaking, reciprocal compression of the lips, and chewing.Results: MN activity in incompetent was significantly higher than competent at rest, and it was significantly higher in incompetent and forced when compared with competent during swallowing (p< .05). No differences among incompetent and forced were observed (p> .05). During speaking, reciprocal compression of the lips, and chewing, MN activity did not show significant differences among groups. BC and SH activity did not show significant differences (p> .05).Conclusion: MN activity during swallowing can be considered a relevant biomarker to differentiate between forced and competent participants.


Assuntos
Músculos Faciais , Lábio , Deglutição , Eletromiografia , Humanos , Mastigação
4.
Cranio ; 40(5): 401-408, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32362247

RESUMO

Objective: To evaluate the effect of the laterotrusive occlusal scheme on chewing duration, external intercostal (EIC) electromyographic (EMG) activity, heart rate (HR), and oxygen saturation (OS) during different tasks in the upright seated position.Methods: Fifty young participants, 25 with canine guidance and 25 with group function, were included. Chewing duration, bilateral EIC EMG activity, HR, and OS were recorded during the following tasks: 1) chewing until swallowing threshold; 2) laterotrusive teeth grinding.Results: Chewing duration, bilateral EIC EMG activity, HR, and OS showed no significant differences between the two laterotrusive occlusal schemes during the tasks studied.Conclusion: These results suggest that chewing duration, EIC muscle activity, HR, and OS were not significantly influenced by the laterotrusive occlusal scheme. Therefore, when a modification of the laterotrusive occlusal scheme is needed during oral rehabilitation or orthodontic treatment, canine guidance or group function should not significantly change EMG activity of EIC muscles.


Assuntos
Oclusão Dentária , Frequência Cardíaca , Mastigação , Músculos da Mastigação , Saturação de Oxigênio , Eletromiografia/métodos , Frequência Cardíaca/fisiologia , Humanos , Mastigação/fisiologia , Músculos da Mastigação/fisiologia
5.
J Esthet Restor Dent ; 34(6): 951-958, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34617663

RESUMO

OBJECTIVE: The aims of this study were to evaluate whether the use of a dentifrice containing 5% potassium nitrate (KNO3 ) prior to and during in-office dental bleaching reduces bleaching-induced tooth sensitivity and affects bleaching efficiency. MATERIALS AND METHODS: Thirty-eight individuals were randomly distributed into two groups (n = 19). The experimental group performed toothbrushing using a dentifrice containing 5% KNO3 , one week before treatment and before the first and second bleaching sessions. In the control group, a placebo dentifrice without KNO3 was applied as described for the first group. Tooth sensitivity was recorded on visual analog scales (VAS) and numeric rating scales (NRS) immediately and up to 48 h after bleaching sessions. Color change at different time intervals, was evaluated with shade guide units (∆SGU) and a digital spectrophotometer (∆E CIELab 1976 and CIEDE2000) at baseline and 7, 15, and 30 days post-bleaching. Mann-Whitney test and t-test were used to evaluate TS intensity for NRS and VAS scales, respectively, and T-test was used for color difference evaluation. RESULTS: No significant difference in tooth sensitivity's absolute risk and intensity were observed between tested groups in any evaluated treatment time for NRS (p = 0.91) or VAS scales (p = 0.48). T-test showed no significant difference in both ∆E and ∆SGU tooth color among the experimental and control groups during the different evaluation times (p = 0.27). CONCLUSION: The use of a dentifrice containing 5% KNO3 does not prevent post-operatory tooth sensitivity but allows the same whitening efficiency as a regular dentifrice. CLINICAL SIGNIFICANCE: The use of a dentifrice-containing KNO3 did not prevent bleaching-induced tooth sensitivity when high-concentrated hydrogen peroxide was used for in-office bleaching.


Assuntos
Dentifrícios , Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Dentifrícios/uso terapêutico , Sensibilidade da Dentina/tratamento farmacológico , Sensibilidade da Dentina/prevenção & controle , Humanos , Peróxido de Hidrogênio/efeitos adversos , Nitratos , Compostos de Potássio/uso terapêutico , Clareamento Dental/efeitos adversos , Clareadores Dentários/efeitos adversos , Resultado do Tratamento
6.
Polymers (Basel) ; 13(7)2021 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-33918441

RESUMO

The aim of the present study was to evaluate the influence of several experimental pretreatment crosslinker solutions on the resin polymer-dentine interface created using a representative universal adhesive system, by means of microtensile bond strength testing (µTBS), nanomechanical properties and ultramorphology confocal laser scanning microscopy (CLSM). Five experimental solutions containing different flavonoids were applied as dentine pretreatment after acid etching. A control pretreatment group containing no flavonoid was also employed. A representative modern universal adhesive was then applied, followed by a 3 mm thick composite built up. Specimens were sectioned into sticks and submitted to a µTBS test or nanoindentation analysis along the interface (24 h or 25,000 thermocycles). The ultramorphology of the polymer-resin interface was also evaluated using CLSM. The results were analyzed using two-way ANOVA and Bonferroni's post hoc test (α = 0.05). All flavonoids improved short- and long-term µTBS values (p < 0.01), while only some specific such solutions improved the nanomechanical properties (p < 0.05) and preserved the structural morphology of the interface after aging. Pretreatment of acid-etched dentine using specific flavonoid-containing solutions may be a promising approach to improve both the nanomechanical properties and the durability of modern universal adhesive systems.

7.
Dent Mater ; 37(6): 1030-1045, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33846019

RESUMO

OBJECTIVE: The aim of study was to develop and characterize experimental bioactive glasses (45S5 and niobophosphate bioactive glass (NbG)) and evaluate the effects of their addition in self-etching adhesive systems on physicochemical, mechanical, and bioactive properties, microtensile bond strength (µTBS), and nanoleakage (NL). METHODS: Two-step self-etching adhesive systems containing 5, 10, and 20 wt.% of 45S5 and NbG bioactive glasses were developed. An experimental adhesive without microparticles and a commercial adhesive (Clearfil SE Bond) were used as control groups. The materials were evaluated for their degree of conversion (DC%), ultimate tensile strength (UTS), softening in solvent, radiopacity, sorption and solubility, alkalizing activity (pH), ionic release, and bioactivity. µTBS and NL were evaluated after 24 h and 1 year of storage. The data were subjected to analysis of variance and post-Holm-Sidak tests (α = 0.05). RESULTS: The addition of the two bioactive glasses did not change the values of the degree of conversion, ultimate tensile strength, and softening in solvent. The adhesive system containing 20% NbG showed the highest radiopacity. The incorporation of 45S5 increased water sorption and solubility, raised the pH, and allowed the release of large amounts of calcium. After 28 days of immersion in simulated body fluid, the 45S5 adhesive precipitated hydroxyapatite and calcium carbonate (SEM/EDX, ATR/FTIR, and XDR). The addition of 45S5 and NbG to the adhesives improved the stability of the resin-dentin interface after 1 year. SIGNIFICANCE: The incorporation of microparticles from 45S5 bioactive glass in self-etching adhesive systems is considered an excellent alternative for the development of a bioactive adhesive that improves the integrity of the hybrid layer on sound dentin.


Assuntos
Colagem Dentária , Cimentos Dentários , Dentina , Teste de Materiais , Resistência à Tração
8.
J Appl Oral Sci ; 28: e20200121, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33263646

RESUMO

OBJECTIVE: Dual-cured buildup composites and simplified light-cured adhesive systems are mixed with a chemical activator to prevent the incompatibility between them. To evaluate microshear bond strength (µSBS) and nanoleakage (NL) of three universal adhesives used under buildup composites using different curing modes, at baseline and after 6-months (6m). METHODOLOGY: Dentin specimens of 55 molars were assigned to: Clearfil Universal Bond[CFU], Prime&Bond Elect[PBE] and One Coat 7 Universal[OCU]. All-Bond Universal[ABU] and Adper Scotchbond Multi-Purpose[SMP] were used as controls. CFU, PBE, and OCU were: light-cured [LC], dual-cured using a self-curing activator [DC], and self-cured, using a self-curing activator and waiting for 20 min [SC]. Upon the application of the adhesive, transparent matrices were filled with a dual-cured buildup composite and light cured, then tested in mSBS. For NL, the specimens were submersed in ammoniacal silver nitrate and sectioned to observe under the SEM. Three-way ANOVA and Tukey's test were applied (α=0.05). RESULTS: OCU/LC-PBE/LC resulted in higher mean µSBS than ABU/LC. For SMP/DC higher mean µSBS were obtained than for both CFU/DC and OCU/DC (baseline). No universal adhesive was significantly affected by curing mode or storage time. CFU, PBE, and OCU did not undergo significant changes in any curing mode (p>0.05). NL (baseline) PBE/LC resulted in higher %NL compared to ABU/LC. SMP/DC resulted in higher %NL than CFU/DC-OCU/DC. CFU/LC/DC resulted in lower %NL than CFU/SC. PBE/SC resulted in lower %NL than PBE/DC. OCU/LC/SC showed lower %NL than OCU/DC. OCU showed significant lower %NL than CFU and PBE. All CFU groups, as well as OCU/SC, resulted in increased %NL at 6m when compared with baseline. CONCLUSION: For universal adhesives used in etch-and-rinse mode, self-cured activator and different curing modes did not influence µSBS. However, some interactions were observed for NL, but this influence was material-specific.


Assuntos
Colagem Dentária , Resinas Compostas , Cimentos Dentários , Dentina , Adesivos Dentinários , Teste de Materiais , Cimentos de Resina , Resistência à Tração
9.
Dent Mater ; 36(9): 1151-1160, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32620332

RESUMO

OBJECTIVES: To evaluate the effect of experimental dentin pre-treatment solutions formulated with different flavonoids on microtensile bond strength (µTBS), nanohardness (NH) and ultra-morphological characteristics of artificial caries-affected dentin (CAD) bonded using a universal bonding system. METHODS: A microbiological method was used to create an artificial CAD in 91 human molars. Five experimental pre-treatment solutions were created using the following flavonoids: quercetin (QUE); hesperidin (HES); rutin (RUT); naringin (NAR), or proanthocyanidin (PRO). A placebo solution (PLA) with no flavonoids added was also evaluated. The flavonoids or placebo solutions were applied to the CAD prior to the application and photoactivation of a universal adhesive (Scotchbond Universal, 3M Oral Care). A control group (CON), in which only the bonding agent was applied without any flavonoid solution, was also evaluated. A 3-mm-thick block of resin composite (Opallis, FGM) was built up on the flat bonded CAD surfaces and was light-cured following the manufacturer's instructions. Specimens were sectioned to obtain resin-dentin slices and sticks (cross-sectional area of 0.8 mm2). The µTBS, NH, and confocal ultramorphology analysis of resin-dentin interface was evaluated at 24 h and after thermo-cycling aging (25,000 cycles). The results were analyzed using 2-way ANOVA followed by Bonferroni's post hoc test (pre-set α = 0.05). RESULTS: The specimens from groups QUE, NAR, and RUT presented greater µTBS values than those from CON group (p<0.05). Specimens from some of these experimental groups presented greater nanomechanical properties (p<0.05), and no morphological degradation at the resin-dentin interface after aging. SIGNIFICANCE: The use of exogenous cross-linkers as dentin pre-treatment before bonding procedures may represent a suitable strategy to improve the longevity of universal adhesive systems applied to caries-affected dentin.


Assuntos
Colagem Dentária , Adesivos Dentinários , Resinas Compostas , Cimentos Dentários , Dentina , Flavonoides , Humanos , Teste de Materiais , Cimentos de Resina , Resistência à Tração
10.
J Dent ; 99: 103407, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32526348

RESUMO

OBJECTIVE: A systematic review and a meta-analysis were performed to answer the following research question: Are there differences in the color match and surface texture of nanofilled/nanohybrid and hybrid composite in patients with direct posterior restorations? DATA: Randomized clinical trials that compared nanofilled/nanohybrid and hybrid composite in direct restoration in posterior teeth were included. For the analysis of the bias the risk of bias tool (RoB) was used. Meta-analyses of different pairs (nanofilled vs. hybrid and nanohybrid vs. hybrid composite) were conducted for surface texture and color match and other secondary outcomes at different follow-ups, using a random effects model. Heterogeneity was assessed with the Cochran Q test and I2 statistics. GRADE was used to assess the quality of the evidence. SOURCES: A search was performed in PubMed, Scopus, Web of Science, LILACS, BBO, Cochrane Library and SIGLE, without restrictions. IADR abstracts (2001-2019), unpublished and ongoing trials registries, dissertations and theses were also searched. STUDY SELECTION: 28 studies remained. No study was considered to be at low RoB; four studies were judged to have high RoB, and the remaining were judged to have unclear RoB. RESULTS: For the primary and secondary outcomes variables no significant differences were detected between nanofilled/nanohybrid restorations and hybrid composite restorations in any of the study follow-ups (p > 0.08). The body of evidence for surface texture and color match was classified as moderate or low. CONCLUSION: No evidence of difference was found between nanofilled/nanohybrid and hybrid composite in any of the clinical parameters evaluated.


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Dente , Materiais Dentários , Humanos
11.
J. appl. oral sci ; 28: e20200121, 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1143148

RESUMO

Abstract Dual-cured buildup composites and simplified light-cured adhesive systems are mixed with a chemical activator to prevent the incompatibility between them. Objective: To evaluate microshear bond strength (μSBS) and nanoleakage (NL) of three universal adhesives used under buildup composites using different curing modes, at baseline and after 6-months (6m). Methodology: Dentin specimens of 55 molars were assigned to: Clearfil Universal Bond[CFU], Prime&Bond Elect[PBE] and One Coat 7 Universal[OCU]. All-Bond Universal[ABU] and Adper Scotchbond Multi-Purpose[SMP] were used as controls. CFU, PBE, and OCU were: light-cured [LC], dual-cured using a self-curing activator [DC], and self-cured, using a self-curing activator and waiting for 20 min [SC]. Upon the application of the adhesive, transparent matrices were filled with a dual-cured buildup composite and light cured, then tested in mSBS. For NL, the specimens were submersed in ammoniacal silver nitrate and sectioned to observe under the SEM. Three-way ANOVA and Tukey's test were applied (α=0.05). Results: OCU/LC-PBE/LC resulted in higher mean μSBS than ABU/LC. For SMP/DC higher mean μSBS were obtained than for both CFU/DC and OCU/DC (baseline). No universal adhesive was significantly affected by curing mode or storage time. CFU, PBE, and OCU did not undergo significant changes in any curing mode (p>0.05). NL (baseline) PBE/LC resulted in higher %NL compared to ABU/LC. SMP/DC resulted in higher %NL than CFU/DC-OCU/DC. CFU/LC/DC resulted in lower %NL than CFU/SC. PBE/SC resulted in lower %NL than PBE/DC. OCU/LC/SC showed lower %NL than OCU/DC. OCU showed significant lower %NL than CFU and PBE. All CFU groups, as well as OCU/SC, resulted in increased %NL at 6m when compared with baseline. Conclusion: For universal adhesives used in etch-and-rinse mode, self-cured activator and different curing modes did not influence μSBS. However, some interactions were observed for NL, but this influence was material-specific.


Assuntos
Colagem Dentária , Resistência à Tração , Teste de Materiais , Adesivos Dentinários , Resinas Compostas , Cimentos de Resina , Cimentos Dentários , Dentina
12.
J Mech Behav Biomed Mater ; 100: 103366, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31422314

RESUMO

This study evaluated the MMP inhibition of the zinc oxide and copper nanoparticles (ZnO/CuNp), and the effects of their addition into adhesives on antimicrobial activity (AMA), ultimate tensile strength (UTS), in vitro degree of conversion (in vitro-DC), as well as, resin-dentin bond strength (µTBS), nanoleakage (NL) and in situ-DC on caries-affected dentin. Anti-MMP activity was evaluated for several MMPs. ZnO/CuNp (0% [control]; 5/0.1 and 5/0.2 wt%) were added into Prime&Bond Active (PBA) and Ambar Universal (AMB). The AMA was evaluated against Streptococcus mutans. UTS were tested after 24 h and 28d. After induced caries, adhesives and composite were applied to flat dentin surfaces, and specimens were sectioned to obtain resin-dentin sticks. µTBS, NL, in vitro-DC and in situ-DC were evaluated after 24 h. ANOVA and Tukey's test were applied (α = 0.05). ZnO/CuNp demonstrated anti-MMP activity (p < 0.05). The addition of ZnO/CuNp increased AMA and UTS (AMB; p < 0.05). UTS for PBA, in vitro-DC, in situ-DC and µTBS for both adhesives were maintained with ZnO/CuNp (p > 0.05). However, lower NL was observed for ZnO/CuNp groups (p < 0.05). The addition of ZnO/CuNp in adhesives may be an alternative to provide antimicrobial, anti-MMP activities and improves the integrity of the hybrid layer on caries-affected dentin.


Assuntos
Cobre/química , Colagem Dentária/instrumentação , Cárie Dentária , Dentina/química , Nanopartículas Metálicas/química , Óxido de Zinco/química , Condicionamento Ácido do Dente , Adesivos , Adolescente , Adulto , Anti-Infecciosos/farmacologia , Resinas Compostas/química , Colagem Dentária/métodos , Adesivos Dentinários/química , Humanos , Teste de Materiais , Metaloproteinases da Matriz/metabolismo , Nanopartículas , Cimentos de Resina/química , Streptococcus mutans/efeitos dos fármacos , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Adulto Jovem
13.
Cranio ; 37(1): 28-34, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29730974

RESUMO

OBJECTIVE: To compare the effect of breathing type on electromyographic (EMG) activity of respiratory muscles during tooth clenching at different decubitus positions. METHODS: Forty young men participants were included, 11 with upper costal, 9 with mixed, and 20 with costo-diaphragmatic breathing type. EMG recordings of diaphragm (DIA), external intercostal (EIC), sternocleidomastoid (SCM), and latissimus dorsi (LAT) muscles during tooth clenching in the intercuspal position were performed in dorsal, left lateral, and ventral decubitus positions. RESULTS: DIA EMG activity was higher in subjects with upper costal or mixed than with costodiaphragmatic breathing type (p = 0.006; 0.021, respectively), whereas it was similar between upper costal and mixed breathing types. EIC, SCM, and LAT activity was similar among breathing types. CONCLUSION: Higher DIA activity would be a risk factor to exceed the adaptive capability of healthy subjects with upper costal or mixed breathing type.


Assuntos
Bruxismo/fisiopatologia , Eletromiografia , Postura/fisiologia , Respiração , Músculos Respiratórios/fisiologia , Adolescente , Adulto , Diafragma/fisiologia , Feminino , Humanos , Masculino , Fatores de Risco , Adulto Jovem
14.
J Adhes Dent ; 19(3): 203-212, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28580465

RESUMO

PURPOSE: To evaluate the effect of a silane and an adhesive containing MDP, used alone or combined in the same solution, on the microshear bond strength (µSBS) to lithium disilicate ceramics immediately and after 1-year water storage, and compare the bond strength results with the Raman spectra of the treated lithium disilicate surfaces. MATERIALS AND METHODS: A total of 30 CAD/CAM blocks of lithium disilicate (LD; IPS e.max CAD) were cut into four square sections (6 x 6 x 6 mm; n = 60 per group) and processed as recommended by the manufacturer. The LD specimens were divided into 12 groups according to the following independent variables: silane coupling agent (no silane; silane without 10-MDP [MBS, Monobond S]; silane with 10-MDP [MB+, Monobond Plus]) and adhesive + luting composite (no adhesive + Enforce; no adhesive + RelyX Ultimate; Prime & Bond Elect [PBE], a silane- and MDP-free universal adhesive + Enforce; Scotchbond Universal Adhesive [SBU], a silane- and MDP-containing universal adhesive + RelyX Ultimate). After each treatment, cylindrical, transparent matrices were filled with a luting composite and light cured. Specimens were stored in water (37°C for 24 h or 1 year) and submitted to the microshear bond strength (µSBS) test. The failure pattern and µSBS were statistically evaluated (α = 0.05). In addition, specimens were examined for chemical interaction using Raman spectroscopy. RESULTS: The use of the adhesive PBE alone showed higher mean µSBS compared with both groups with silane (MSB or MB+) without PBE (p < 0.001) at 24 h. The use of the SBU adhesive or MBS silane alone, as well as MB+ associated with SBU, showed higher mean µSBS (p < 0.001) at 24 h. After 1-year water storage, all groups showed a significant decrease in mean µSBS. However, the application of PBE or SBU associated with MB+ silane showed higher 1-year mean µSBS (p < 0.001). In terms of chemical interaction, when silane (MSB or MB+) was applied, only a slight decrease of Si-O peaks occurred. Otherwise, when PBE or SBU adhesives were applied, methacrylate peaks were only observed in the SBU groups. CONCLUSION: The best results in terms of bond strength after water storage were obtained when an MDP-containing silane was associated with a universal adhesive. The use of a simplified bonding protocol that includes either a silane or a universal adhesive is not recommended.


Assuntos
Colagem Dentária , Silanos , Cerâmica , Porcelana Dentária , Teste de Materiais , Resistência ao Cisalhamento
15.
Dent Mater ; 33(7): 775-787, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28487037

RESUMO

OBJECTIVES: To measure microshear bond strength (µSBS) and nanoleakage (NL) of self-etch universal adhesives under core buildup restorations using different curing protocols, at 24h and after 6-month water storage. METHODS: Middle dentin of 55 molars was divided into: Clearfil Universal Bond [CFU], Prime&Bond Elect [PBE], and One Coat 7 Universal [OCU]. All-Bond Universal [ABU] and Clearfil SE Bond [CSE] were used as control. CFU, PBE and OCU were: light-cured [LC], dual-cured [DC] and self-cured [SC]. Data were analyzed separately (two-way ANOVA), Tukey's test (α=0.05). RESULTS: µSBS: At 24h OCU/LC resulted in statistically higher µSBS than ABU. CSE/DC showed statistically higher µSBS than all DC adhesives. PBE/LC resulted in significant lower µSBS than the respective DC/SC modes (p<0.001). At 6-month, both CFU and PBE (LC/SC), resulted in a significant decrease in µSBS. µSBS for OCU/DC decreased significantly (p<0.001) compared to the respective LC/SC modes. NL: At 24h, ABU showed %NL similar to CBU/LC and OCU/LC (p>0.05). CSE/DC resulted in significantly higher %NL than OCU/DC but significantly lower than PBE/DC. CFU/LC/SC resulted in significantly lower %NL than CFU/DC. PBE/SC resulted in significant lower %NL than PBE/LC and PBE/DC. OCU/LC and OCU/DC resulted in significant lower %NL than OCU/SC (p<0.001). At 6-month ABU, CSE, CFU/LC and CFU/SC, resulted in a significant increase in %NL. SIGNIFICANCE: Self-cured activator and different curing protocols influenced µSBS and NL of self-etch universal adhesives, but this influence was material-dependent.


Assuntos
Cimentos Dentários , Dentina , Cimentos de Resina , Resinas Compostas , Colagem Dentária , Adesivos Dentinários , Humanos , Teste de Materiais , Resistência à Tração
16.
Cranio ; 35(2): 110-115, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27077252

RESUMO

AIM: To compare the effect of breathing type on the activity of respiratory muscles at different body positions. METHODOLOGY: Two groups of 20 subjects each, one with upper costal and the other with costodiaphragmatic breathing, were studied. Electromyographic activity of sternocleidomastoid (SCM), diaphragm (DIA), external intercostal (EIC), and latissimus dorsi (LAT) muscles was recorded at standing and lateral decubitus positions during swallowing and maximal voluntary clenching. RESULTS: All muscles showed higher activity during standing in upper costal breathing subjects except the SCM muscle. EIC activity was higher during standing in the costodiaphragmatic breathing group. Subjects with upper costal breathing showed higher DIA activity than subjects with costodiaphragmatic breathing at both body positions and higher SCM activity at lateral decubitus position, whereas, EIC activity was only higher during swallowing. CONCLUSIONS: Subjects with upper costal breathing presented higher respiratory effort than subjects with costodiaphragmatic breathing, being most prominent at the lateral decubitus position.


Assuntos
Respiração , Músculos Respiratórios/fisiologia , Deglutição/fisiologia , Diafragma/fisiologia , Eletromiografia , Humanos , Músculos Intercostais/fisiologia , Masculino , Postura/fisiologia , Adulto Jovem
17.
J Adhes Dent ; 18(4): 331-40, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27419246

RESUMO

PURPOSE: To evaluate the microshear bond strength (µSBS) of several universal adhesive systems applied on five different indirect restorative materials. MATERIALS AND METHODS: Five CAD/CAM materials were selected: 1) indirect resin composite (LAV); 2) feldspathic glass ceramic (VTR); 3) leucite-reinforced glass-ceramic (EMP); 4) lithium disilicate ceramic (EMX); 5) yttrium-stabilized zirconium dioxide (CZI). For each material, 15 blocks were cut into 4 rectangular sections (6 × 6 × 6 mm) (n = 60 per group), and processed as recommended by the respective manufacturer. For each indirect material, the following adhesive systems were applied according to the respective manufacturer's instructions: 1) AdheSE Universal [ADU]; 2) All-Bond Universal (ABU); 3) Ambar Universal (AMB); 4) Clearfil Universal (CFU); 5) Futurabond U (FBU); 6) One Coat 7 Universal (OCU); 7) Peak Universal Bond (PUB); 8) Prime&Bond Elect (PBE); 9) Scotchbond Universal Adhesive (SBU); 10) Xeno Select (XEN, negative control). After the application of the adhesive system, cylinder-shaped transparent matrices were filled with a dual-curing resin cement (NX3) and light cured. Specimens were stored in water (37°C for 24 h) and tested in shear mode at 1.0 mm/min (mSBS). The failure pattern and µSBS were statistically evaluated (a = 0.05). RESULTS: LAV, VTR, and EMP showed a greater number of cohesive fractures than EMX and CZI (p < 0.0001). PUB was the only adhesive for which the mean µSBS reached the highest ranking of statistical significance for all five substrates. When each adhesive was compared across the five substrates, 8 out of 10 (ADU, ABU, AMB, CFU, OCU, PUB, PBE, and SBU) reached the statistically highest mean µSBS when applied on CZI. CONCLUSION: The specific chemical composition of universal adhesives was not the decisive factor in the bond strength values measured for different CAD/CAM indirect materials. There was a wide variability in mean µSBS when different universal adhesives were applied to the several CAD/CAM indirect materials. Most universal adhesives bonded well to air-abraded zirconia.


Assuntos
Desenho Assistido por Computador , Colagem Dentária , Materiais Dentários/química , Cimentos de Resina/química , Resinas Acrílicas/química , Silicatos de Alumínio/química , Bis-Fenol A-Glicidil Metacrilato/química , Cerâmica/química , Resinas Compostas/química , Porcelana Dentária/química , Restauração Dentária Permanente , Humanos , Teste de Materiais , Metacrilatos/química , Ácidos Polimetacrílicos/química , Compostos de Potássio/química , Resistência ao Cisalhamento , Estresse Mecânico , Temperatura , Fatores de Tempo , Água/química , Ítrio/química , Zircônio/química
18.
J Dent ; 49: 60-7, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27106766

RESUMO

OBJECTIVES: To evaluate the effect of treatment using collagen cross-linking agents as primer on resin-dentin bond interfaces subjected to cariogenic oral environment (COE). METHODS: Each of forty human teeth had two cavities (4×4×1.5mm) prepared within enamel margins. These cavities were acid-etched and treated by the primers containing one of the following treatment agents (6.5% proanthocyanidins, 0.1% riboflavin-UVA activated light, 5% glutaraldehyde or distilled water as a control group). After that the cavities were bonded and restored with resin composite. One restoration for each tooth was tested immediately (IM) and another was included in an intra-oral palatal device that was placed in each mouth of ten adult volunteers for 14 days in COE. After 14 days, the teeth were removed and each restoration was sectioned to obtain a slice for Knoop microhardness (KHN) and resin-dentin bonded sticks for microtensile bond strength (µTBS) and nanoleakage (NL) evaluation. Data were evaluated by two-way ANOVA and Tukey's tests (α=0.05). RESULTS: After 14days in a COE, the KHN was reduced for all groups, except for the glutaraldehyde group; however, the proanthocyanidins group retained the highest KHN in IM and after COE (p<0.05). The µTBS was not reduced after COE for the proanthocyanidins and glutaraldehyde groups, however only the proanthocyanidins treatment did not increase the NL after COE (p>0.05). CONCLUSION: The in situ study model seems to be a suitable short-term methodology to investigate the degradation of the bonding interfaces under a more realistic condition. Under COE, the proanthocyanidins and glutaraldehyde treatments produced stable interfaces that are worth further clinical investigation.


Assuntos
Dentina , Condicionamento Ácido do Dente , Colágeno , Resinas Compostas , Colagem Dentária , Infiltração Dentária , Adesivos Dentinários , Humanos , Teste de Materiais , Cimentos de Resina , Resistência à Tração
19.
Dent Mater ; 32(6): 732-41, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27087688

RESUMO

OBJECTIVE: To investigate the effect of collagen cross-links on the stability of adhesive properties, the degree of conversion within the hybrid layer, cytotoxicity and the inhibition potential of the MMPs' activity. METHODS: The dentin surfaces of human molars were acid-etched and treated with primers containing: 6.5wt% proanthocyanidin, UVA-activated 0.1wt% riboflavin, 5wt% glutaraldehyde and distilled water for 60s. Following, dentin was bonded with Adper Single Bond Plus and Tetric N-Bond; and restored with resin composite. The samples were sectioned into resin-dentin "sticks" and tested for microtensile bond strength (µTBS) after immediate (IM) and 18-month (18M) periods. Bonded sticks at each period were used to evaluate nanoleakage and the degree of conversion (DC) under micro-Raman spectroscopy. The enzimatic activity (P1L10 cross-linkers, P1L22 MMPs' activities) in the hybrid layer was evaluated under confocal microscopy. The culture cell (NIH 3T3 fibroblast cell line) and MTT assay were performed to transdentinal cytotoxicity evaluation. Data from all tests were submitted to appropriate statistical analysis (α=0.05). RESULTS: All cross-linking primers reduced the degradation of µTBS compared with the control group after 18M (p>0.05). The DC was not affected (p>0.213). The NL increased after 18M for all experimental groups, except for proanthocyanidin with Single Bond Plus (p>0.05). All of the cross-link agents reduced the MMPs' activity, although this inhibition was more pronounced by PA. The cytotoxicity assay revealed reduced cell viability only for glutaraldehyde (p<0.001). SIGNIFICANCE: Cross-linking primers used in clinically relevant minimized the time degradation of the µTBS without jeopardizing the adhesive polymerization, as well as reduced the collagenolytic activity of MMPs. Glutaraldeyde reduced cell viability significantly and should be avoided for clinical use.


Assuntos
Adesivos Dentinários , Cimentos de Resina , Condicionamento Ácido do Dente , Colágeno , Colagem Dentária , Cimentos Dentários , Infiltração Dentária , Dentina , Humanos , Teste de Materiais , Estresse Mecânico , Resistência à Tração
20.
J Adhes Dent ; 18(1): 35-42, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26814314

RESUMO

PURPOSE: To evaluate the effect of an acid containing 2% chlorhexidine (Ac/CHX) or a 2% CHX aqueous solution (Aq/CHX) on the immediate and 5-year bonding properties of resin/dentin interfaces produced by two adhesives. The presence of CHX in these interfaces was also evaluated under micro-Raman spectroscopy. MATERIALS AND METHODS: Forty-two molars were ground to expose a flat dentin surface. In the control group, the surfaces were etched with conventional phosphoric acid, and Prime&Bond NT (PB) and Adper Single Bond 2 (SB) were applied. In Ac/CHX, an acid containing 2% CHX was applied after adhesive application. In the Aq/CHX group, an aqueous solution of 2% CHX was applied for 60 s after etching. After placing the restoration, specimens were prepared and tested using the microtensile bond strength test (µTBS, 0.5 mm/min) immediately or after 5 years. For nanoleakage (NL), specimens at each period were immersed in silver nitrate solution and examined by EDX-SEM. In addition, specimens at each period underwent examination for CHX using micro-Raman spectroscopy. Data were submitted to appropriate statistical analysis (a=0.05). RESULTS: After 5 years, NL was more pronounced in the control than in the Ac/CHX or Aq/CHX (p<0.001). Significant reductions in the µTBS were observed for all groups; however, they were more pronounced for the control (p<0.001). CHX was still present in the hybrid layers Ac/CHX or Aq/CHX groups after 5 years. CONCLUSION: The use of a 2% chlorhexidine-containing acid or the application of an aqueous CHX primer may increase the long-term stability of resin/dentin interfaces.


Assuntos
Clorexidina/análogos & derivados , Resinas Compostas/química , Colagem Dentária , Materiais Dentários/química , Dentina/ultraestrutura , Inibidores Enzimáticos/química , Cimentos de Resina/química , Condicionamento Ácido do Dente/métodos , Clorexidina/química , Cimentos Dentários/química , Infiltração Dentária/classificação , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Ácidos Fosfóricos/química , Ácidos Polimetacrílicos/química , Distribuição Aleatória , Coloração pela Prata , Espectrometria por Raios X , Análise Espectral Raman , Resistência à Tração , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...