Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Infect Control Hosp Epidemiol ; 44(1): 106-109, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35705231

RESUMO

At our hospital, universal severe acute respiratory coronavirus virus 2 (SARS-CoV-2) polymerase chain reaction (PCR) testing was performed upon admission and again after 2 inpatient days. As community-wide prevalence, admission, and vaccination rates varied, the number needed to benefit fluctuated between 16 and 769 and the cost per additional detection fluctuated between $800 and $29,400. These 2 metrics were negatively associated with new hospital admissions. No other community indicator was associated with the number needed to benefit and cost per additional detection.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/prevenção & controle , Prevalência , Análise Custo-Benefício , Reação em Cadeia da Polimerase , Hospitalização , Hospitais , Vacinação , Teste para COVID-19
2.
PLoS One ; 17(1): e0261365, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35061676

RESUMO

BACKGROUND: Cleanliness of hospital surfaces helps prevent healthcare-associated infections, but comparative evaluations of various cleaning strategies during COVID-19 pandemic surges and worker shortages are scarce. PURPOSE AND METHODS: To evaluate the effectiveness of daily, enhanced terminal, and contingency-based cleaning strategies in an acute care hospital (ACH) and a long-term care facility (LTCF), using SARS-CoV-2 RT-PCR and adenosine triphosphate (ATP) assays. Daily cleaning involved light dusting and removal of visible debris while a patient is in the room. Enhanced terminal cleaning involved wet moping and surface wiping with disinfectants after a patient is permanently moved out of a room followed by ultraviolet light (UV-C), electrostatic spraying, or room fogging. Contingency-based strategies, performed only at the LTCF, involved cleaning by a commercial environmental remediation company with proprietary chemicals and room fogging. Ambient surface contamination was also assessed randomly, without regard to cleaning times. Near-patient or high-touch stationary and non-stationary environmental surfaces were sampled with pre-moistened swabs in viral transport media. RESULTS: At the ACH, SARS-CoV-2 RNA was detected on 66% of surfaces before cleaning and on 23% of those surfaces immediately after terminal cleaning, for a 65% post-cleaning reduction (p = 0.001). UV-C enhancement resulted in an 83% reduction (p = 0.023), while enhancement with electrostatic bleach application resulted in a 50% reduction (p = 0.010). ATP levels on RNA positive surfaces were not significantly different from those of RNA negative surfaces. LTCF contamination rates differed between the dementia, rehabilitation, and residential units (p = 0.005). 67% of surfaces had RNA after room fogging without terminal-style wiping. Fogging with wiping led to a -11% change in the proportion of positive surfaces. At the LTCF, mean ATP levels were lower after terminal cleaning (p = 0.016). CONCLUSION: Ambient surface contamination varied by type of unit and outbreak conditions, but not facility type. Removal of SARS-CoV-2 RNA varied according to cleaning strategy. IMPLICATIONS: Previous reports have shown time spent cleaning by hospital employed environmental services staff did not correlate with cleaning thoroughness. However, time spent cleaning by a commercial remediation company in this study was associated with cleaning effectiveness. These findings may be useful for optimizing allocation of cleaning resources during staffing shortages.


Assuntos
COVID-19/prevenção & controle , Infecção Hospitalar/prevenção & controle , Desinfecção/métodos , Pessoal de Saúde/organização & administração , Controle de Infecções/organização & administração , Assistência de Longa Duração/organização & administração , Trifosfato de Adenosina/análise , COVID-19/epidemiologia , Infecção Hospitalar/epidemiologia , Desinfetantes , Fômites/virologia , Instalações de Saúde , Humanos , New York/epidemiologia , Quartos de Pacientes , RNA Viral/análise , SARS-CoV-2/genética , SARS-CoV-2/patogenicidade , SARS-CoV-2/efeitos da radiação , Raios Ultravioleta
3.
Infect Control Hosp Epidemiol ; 43(11): 1641-1646, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35034676

RESUMO

OBJECTIVE: To quantitatively evaluate relationships between infection preventionists (IPs) staffing levels, nursing hours, and rates of 10 types of healthcare-associated infections (HAIs). DESIGN AND SETTING: An ambidirectional observation in a 528-bed teaching hospital. PATIENTS: All inpatients from July 1, 2012, to February 1, 2021. METHODS: Standardized US National Health Safety Network (NHSN) definitions were used for HAIs. Staffing levels were measured in full-time equivalents (FTE) for IPs and total monthly hours worked for nurses. A time-trend analysis using control charts, t tests, Poisson tests, and regression analysis was performed using Minitab and R computing programs on rates and standardized infection ratios (SIRs) of 10 types of HAIs. An additional analysis was performed on 3 stratifications: critically low (2-3 FTE), below recommended IP levels (4-6 FTE), and at recommended IP levels (7-8 FTE). RESULTS: The observation covered 1.6 million patient days of surveillance. IP staffing levels fluctuated from ≤2 IP FTE (critically low) to 7-8 IP FTE (recommended levels). Periods of highest catheter-associated urinary tract infection SIRs, hospital-onset Clostridioides difficile and carbapenem-resistant Enterobacteriaceae infection rates, along with 4 of 5 types of surgical site SIRs coincided with the periods of lowest IP staffing levels and the absence of certified IPs and a healthcare epidemiologist. Central-line-associated bloodstream infections increased amid lower nursing levels despite the increased presence of an IP and a hospital epidemiologist. CONCLUSIONS: Of 10 HAIs, 8 had highest incidences during periods of lowest IP staffing and experience. Some HAI rates varied inversely with levels of IP staffing and experience and others appeared to be more influenced by nursing levels or other confounders.


Assuntos
Infecções Relacionadas a Cateter , Infecção Hospitalar , Infecções Urinárias , Humanos , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/prevenção & controle , Infecções Urinárias/epidemiologia , Infecções Urinárias/prevenção & controle , Hospitais de Ensino , Recursos Humanos , Atenção à Saúde , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/prevenção & controle
4.
Infect Control Hosp Epidemiol ; 42(11): 1333-1339, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33427144

RESUMO

OBJECTIVE: We sought to contain a healthcare-associated coronavirus disease 2019 (COVID-19) outbreak, to evaluate contributory factors, and to prevent future outbreaks. DESIGN: Quasi-experimental cluster-control outbreak evaluation. METHODS: All patients and staff on the outbreak ward (case cluster), and randomly selected patients and staff on COVID-19 wards (positive control cluster) and a non-COVID-19 wards (negative control cluster) underwent reverse-transcriptase polymerase chain reaction (RT-PCR) testing. Hand hygiene and personal protective equipment (PPE) compliance, detection of environmental SARS-COV-2 RNA, patient behavior, and SARS-CoV-2 IgG antibody prevalence were assessed. RESULTS: In total, 145 staff and 26 patients were exposed, resulting in 24 secondary cases. Also, 4 of 14 (29%) staff and 7 of 10 (70%) patients were asymptomatic or presymptomatic. There was no difference in mean cycle threshold between asymptomatic or presymptomatic versus symptomatic individuals. None of 32 randomly selected staff from the control wards tested positive. Environmental RNA detection levels were higher on the COVID-19 ward than on the negative control ward (OR, 19.98; 95% CI, 2.63-906.38; P < .001). RNA levels on the COVID-19 ward (where there were no outbreaks) and the outbreak ward were similar (OR, 2.38; P = .18). Mean monthly hand hygiene compliance, based on 20,146 observations (over preceding year), was lower on the outbreak ward (P < .006). Compared to both control wards, the proportion of staff with detectable antibodies was higher on the outbreak ward (OR, 3.78; 95% CI, 1.01-14.25; P = .008). CONCLUSION: Staff seroconversion was more likely during a short-term outbreak than from sustained duty on a COVID-19 ward. Environmental contamination and PPE use were similar on the outbreak and control wards. Patient noncompliance, decreased hand hygiene, and asymptomatic or presymptomatic transmission were more frequent on the outbreak ward.


Assuntos
COVID-19 , Demência , Acidente Vascular Cerebral , Surtos de Doenças , Humanos , Controle de Infecções , RNA Viral , SARS-CoV-2
5.
Am J Epidemiol ; 183(11): 1063-70, 2016 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-27188939

RESUMO

Diagnosis of pertussis remains a challenge, and consequently research on the risk of disease might be biased because of misclassification. We quantified this misclassification and corrected for it in a case-control study of children in Philadelphia, Pennsylvania, who were 3 months to 6 years of age and diagnosed with pertussis between 2011 and 2013. Vaccine effectiveness (VE; calculated as (1 - odds ratio) × 100) was used to describe the average reduction in reported pertussis incidence resulting from persons being up to date on pertussis-antigen containing vaccines. Bayesian techniques were used to correct for purported nondifferential misclassification by reclassifying the cases per the 2014 Council of State and Territorial Epidemiologists pertussis case definition. Naïve VE was 50% (95% confidence interval: 16%, 69%). After correcting for misclassification, VE ranged from 57% (95% credible interval: 30, 73) to 82% (95% credible interval: 43, 95), depending on the amount of underreporting of pertussis that was assumed to have occurred in the study period. Meaningful misclassification was observed in terms of false negatives detected after the incorporation of infant apnea to the 2014 case definition. Although specificity was nearly perfect, sensitivity of the case definition varied from 90% to 20%, depending on the assumption about missed cases. Knowing the degree of the underreporting is essential to the accurate evaluation of VE.


Assuntos
Teorema de Bayes , Notificação de Doenças/estatística & dados numéricos , Notificação de Doenças/normas , Vacina contra Coqueluche/imunologia , Coqueluche/diagnóstico , Estudos de Casos e Controles , Criança , Pré-Escolar , Feminino , Humanos , Incidência , Lactente , Masculino , Razão de Chances , Philadelphia , Sensibilidade e Especificidade , Fatores Socioeconômicos , Coqueluche/epidemiologia
6.
MMWR Morb Mortal Wkly Rep ; 65(11): 282-5, 2016 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-27010342

RESUMO

In December 2011 and December 2013, the Philadelphia Department of Public Health (PDPH) received separate reports of clusters of photokeratitis linked to gymnasium events. Photokeratitis, a painful eye condition resulting from unprotected exposure to ultraviolet radiation, has previously been linked to metal halide lamps with broken outer envelopes (1,2). To investigate the cause of these clusters and further characterize patients with photokeratitis, PDPH administered questionnaires to potentially exposed persons, established a case definition, and conducted environmental assessments of both gymnasiums. Because event attendee registration information was available, a cohort study was conducted to evaluate the 2011 cluster of 242 persons who met the photokeratitis case definition. A case-series investigation was conducted to evaluate the 2013 cluster of 20 persons who met the photokeratitis case definition for that event. These investigations indicated that Type R metal halide bulbs with broken outer envelopes found in both gymnasiums were the probable cause of the photokeratitis. The Food and Drug Administration has made a number of recommendations regarding the use of metal halide bulbs in facilities where bulbs are at elevated risk for breaking, such as schools and indoor sports facilities (3). Because Type R metal halide lamps do not self-extinguish once the outer envelope is broken, these bulbs should be removed from settings with a high risk for outer envelope rupture, such as gymnasiums, or should be placed within enclosed fixtures. In instances where these bulbs cannot be exchanged for self-extinguishing lamps, Type R lamps with a broken outer envelope should be replaced immediately to limit exposure to ultraviolet radiation. A broken outer envelope can be detected by the presence of glass on the floor, or visual examination of the bulb when the power is turned off. A broken outer envelope is difficult to detect when the lamp is emitting light.


Assuntos
Surtos de Doenças/estatística & dados numéricos , Exposição Ambiental/efeitos adversos , Ceratite/etiologia , Iluminação/efeitos adversos , Transtornos de Fotossensibilidade/etiologia , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Halogênios , Humanos , Lactente , Recém-Nascido , Ceratite/epidemiologia , Masculino , Metais , Pessoa de Meia-Idade , Philadelphia/epidemiologia , Transtornos de Fotossensibilidade/epidemiologia , Adulto Jovem
7.
Infect Control Hosp Epidemiol ; 37(2): 125-33, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26573412

RESUMO

BACKGROUND In November and December 2012, 6 patients at a hemodialysis clinic were given a diagnosis of new hepatitis C virus (HCV) infection. OBJECTIVE To investigate the outbreak to identify risk factors for transmission. METHODS A case patient was defined as a patient who was HCV-antibody negative on clinic admission but subsequently was found to be HCV-antibody positive from January 1, 2008, through April 30, 2013. Patient charts were reviewed to identify and describe case patients. The hypervariable region 1 of HCV from infected patients was tested to assess viral genetic relatedness. Infection control practices were evaluated via observations. A forensic chemiluminescent agent was used to identify blood contamination on environmental surfaces after cleaning. RESULTS Eighteen case patients were identified at the clinic from January 1, 2008, through April 30, 2013, resulting in an estimated 16.7% attack rate. Analysis of HCV quasispecies identified 4 separate clusters of transmission involving 11 case patients. The case patients and previously infected patients in each cluster were treated in neighboring dialysis stations during the same shift, or at the same dialysis station on 2 consecutive shifts. Lapses in infection control were identified. Visible and invisible blood was identified on multiple surfaces at the clinic. CONCLUSIONS Epidemiologic and laboratory data confirmed transmission of HCV among numerous patients at the dialysis clinic over 6 years. Infection control breaches were likely responsible. This outbreak highlights the importance of rigorous adherence to recommended infection control practices in dialysis settings.


Assuntos
Infecção Hospitalar/epidemiologia , Infecção Hospitalar/transmissão , Hepatite C/epidemiologia , Hepatite C/transmissão , Diálise Renal/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Instituições de Assistência Ambulatorial , Infecção Hospitalar/prevenção & controle , Infecção Hospitalar/virologia , Surtos de Doenças/prevenção & controle , Contaminação de Equipamentos , Feminino , Hepacivirus/genética , Hepacivirus/isolamento & purificação , Hepatite C/sangue , Hepatite C/prevenção & controle , Humanos , Controle de Infecções/métodos , Luminescência , Masculino , Prontuários Médicos , Pessoa de Meia-Idade , Philadelphia/epidemiologia , Reação em Cadeia da Polimerase em Tempo Real , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...