Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Alemão | MEDLINE | ID: mdl-38701804

RESUMO

OBJECTIVE: The objective of this study was to evaluate the signalement, clinical features, and echocardiographic findings of cats diagnosed with patent ductus arteriosus (PDA) as well as short- and medium-term outcome after successful ligation of the PDA. MATERIAL AND METHODS: Over a 10-year period 17 cats were diagnosed with PDA by transthoracic echocardiography. Thirteen cats were surgically treated by thoracotomy and ligation of the PDA. RESULTS: In all cats, a heart murmur was detected. In 88.2% of the cases, this presented as grade 4 out of 6 murmur (15/17 cats). A continuous murmur was more common (10/17 cats; 58.9%) than a systolic murmur (7/17 cats; 41.1%). Echocardiography showed that left ventricular internal diameter end diastole (LVIDd) and left ventricular internal diameter end systole (LVIDs) were significantly above reference values in the majority of cats. Mean diameter of the PDA measured at the widest point of the vessel was 3.4 mm (± 1.08 mm) and mean maximum flow velocity amounted to 5,06 m/sec (2,6m/sec-6,4m/sec). Surgery was successfully performed in all cats treated by surgical ligation and all of these patients were discharged after postoperative inpatient therapy. One cat experienced perioperative bleeding from the PDA, which was stopped efficaciously. This cat exhibited a residual shunt directly postoperatively; this could no longer be visualized in a re-check echocardiography 3 months later. Six cats were followed over a longer period of time. CONCLUSIONS: The surgical prognosis in this case study is very good with a postoperative survival rate of 100%. CLINICAL RELEVANCE: Surgical treatment of PDA is curative in animals not displaying advanced cardiac lesions. The auscultation of a heart murmur can provide initial findings indicative of PDA. Therefore, cardiac auscultation is warranted at every first presentation of a kitten. It must however be taken into consideration that not every cat with PDA necessarily has a continuous murmur but may display a systolic heart murmur. Therefore, it is important give utmost attention to the patients' clinical signs.


Assuntos
Doenças do Gato , Permeabilidade do Canal Arterial , Ecocardiografia , Animais , Gatos , Permeabilidade do Canal Arterial/veterinária , Permeabilidade do Canal Arterial/cirurgia , Permeabilidade do Canal Arterial/diagnóstico , Doenças do Gato/cirurgia , Doenças do Gato/diagnóstico , Estudos Retrospectivos , Ecocardiografia/veterinária , Ligadura/veterinária , Sopros Cardíacos/veterinária , Sopros Cardíacos/diagnóstico , Sopros Cardíacos/cirurgia , Sopros Cardíacos/etiologia , Feminino , Masculino
2.
Artigo em Alemão | MEDLINE | ID: mdl-38701807

RESUMO

A 3-month-old and a 4-year-old cat were presented in the clinic due to regurgitation. The kitten had displayed the symptoms since it had been fed solid foods and was smaller than the litter mates. The 4-year-old cat showed sudden-onset symptoms for 5 days prior to presentation and had a good general condition. Positive contrast thoracic radiographs of both cats in lateral recumbency showed an esophageal dilatation cranial to the heart base and raised a suspicion of foreign material with soft tissue density in this area. In the 4-year-old cat, findings of ventrodorsal thoracic radiographs were compatible with a dextroposition of the aorta and a slightly marked focal left curve of the trachea. The echocardiographic examination of the kitten pictured a right sided aorta, hence a vascular ring anomaly with a dextroposition from the aorta was suspected. Aberrant blood flow as it is seen in a persistent ductus arteriosus was not apparent in the echocardiography. As a result of the sudden development of the clinical signs in the older cat without displaying any former history of regurgitation, an esophagoscopy was performed to exclude an intraluminal esophageal cause for the stricture as well as to extract the foreign material. In this cat, computed tomography imaging also displayed an aberrant left subclavian artery. Both cats recovered well after surgical correction.The diagnosis of a ring anomaly in the kitten via echocardiography is a rare situation. As is the diagnosis of a high-grade esophageal stricture due to a vascular ring anomaly at the age of 4 without a former history of regurgitation.Recovery was excellent in the younger cat. There were no signs of regurgitation 6 months after surgery. The adult cat was in good general condition without clinical symptoms according to the owners when presented for stitch removal. Unfortunately, the adult cat was lost to follow up.


Assuntos
Aorta Torácica , Doenças do Gato , Estenose Esofágica , Animais , Gatos , Estenose Esofágica/veterinária , Estenose Esofágica/diagnóstico por imagem , Estenose Esofágica/diagnóstico , Doenças do Gato/diagnóstico , Doenças do Gato/diagnóstico por imagem , Doenças do Gato/cirurgia , Aorta Torácica/anormalidades , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Masculino
3.
Case Rep Vet Med ; 2020: 8848627, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33149956

RESUMO

Intracardiac thrombi are rare in dogs. If they occur, they are mostly seen in the right atrium while only two case reports describing a mural left atrial thrombus in dogs are available. This case report describes a 14-year-old mixed-breed bitch that was presented at the clinic because of dyspnoea. The dog suffered from alopecia for about three years and displayed polyuria and polydipsia for a number of months. Clinical examination revealed intensified inspiratory and expiratory respiratory sounds and various heart sounds. Chest X-ray showed cardiomegaly (VHS 11) and a mixed bronchoalveolar lung pattern of the caudal lung. A transthoracic echocardiography was performed and showed a moderate mitral regurgitation, a highly dilated left atrium, a low-grade pulmonary insufficiency, and a minimal aortic and tricuspid insufficiency. Additionally, a free-floating ball thrombus was found in the left atrium. Hyperadrenocorticism was indicated by an ACTH stimulation test. The previous medical therapy of the referring veterinarian consisted of benazepril and furosemide and was complemented by clopidogrel. The pet owners declined any further clinical diagnostics and therapy. The dog died 19 days later. This is the first reported case of a dog with a free-floating left atrial thrombus. Specific therapeutic strategies for intracardiac thrombi in the dog are currently not available, and therefore, every patient should be treated individually.

4.
J Am Vet Med Assoc ; 240(8): 962-8, 2012 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-22471825

RESUMO

OBJECTIVE: To evaluate the agreement of blood pressure measurements and hypertension scores obtained by use of 3 indirect arterial blood pressure measurement devices in hospitalized dogs. Design-Diagnostic test evaluation. ANIMALS: 29 client-owned dogs. PROCEDURES: 5 to 7 consecutive blood pressure readings were obtained from each dog on each of 3 occasions with a Doppler ultrasonic flow detector, a standard oscillometric device (STO), and a high-definition oscillometric device (HDO). RESULTS: When the individual sets of 5 to 7 readings were evaluated, the coefficient of variation for systolic arterial blood pressure (SAP) exceeded 20% for 0% (Doppler), 11 % (STO), and 28% (HDO) of the sets of readings. After readings that exceeded a 20% coefficient of variation were discarded, repeatability was within 25 (Doppler), 37 (STO), and 39 (HDO) mm Hg for SAP. Correlation of mean values among the devices was between 0.47 and 0.63. Compared with Doppler readings, STO underestimated and HDO overestimated SAP. Limits of agreement between mean readings of any 2 devices were wide. With the hypertension scale used to score SAP, the intraclass correlation of scores was 0.48. Linear-weighted inter-rater reliability between scores was 0.40 (Doppler vs STO), 0.38 (Doppler vs HDO), and 0.29 (STO vs HDO). CONCLUSIONS AND CLINICAL RELEVANCE: Results of this study suggested that no meaningful clinical comparison can be made between blood pressure readings obtained from the same dog with different indirect blood pressure measurement devices.


Assuntos
Determinação da Pressão Arterial/veterinária , Pressão Sanguínea/fisiologia , Doenças do Cão/diagnóstico , Hipertensão/veterinária , Oscilometria/veterinária , Ultrassonografia Doppler/veterinária , Animais , Determinação da Pressão Arterial/instrumentação , Determinação da Pressão Arterial/métodos , Cães , Feminino , Membro Anterior , Hipertensão/diagnóstico , Masculino , Oscilometria/instrumentação , Oscilometria/métodos , Ultrassonografia Doppler/instrumentação , Ultrassonografia Doppler/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...