Sensors (Basel) ; 21(24)2021 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-34960312

RESUMO

Structural health monitoring (SHM) can be more efficient with the application of a wireless sensor network (WSN). However, the hardware that makes up this system should have sufficient performance to sample the data collected from the sensor in real-time situations. High-performance hardware can be used for this purpose, but is not suitable in this application because of its relatively high power consumption, high cost, large size, and so on. In this paper, an optimal remote monitoring system platform for SHM is proposed based on pulsed eddy current (PEC) that is utilized for measuring the corrosion of a steel-framed construction. A circuit to delay the PEC response based on the resistance-inductance-capacitance (RLC) combination was designed for data sampling to utilize the conventional hardware of WSN for SHM, and this approach was verified by simulations and experiments. Especially, the importance of configuring sensing modules and the WSN for remote monitoring were studied, and the PEC responses caused by the corrosion of a specimen made with steel were able to be sampled remotely using the proposed system. Therefore, we present a remote SHM system platform for diagnosing the corrosion condition of a building with a steel structure, and proving its viability with experiments.